Chapter 3 — GENERAL REGULATIONS
312.12 Rodentproofing.
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Strainer plates on drain inlets shall be designed and installed so that no opening exceeds [1] ⁄ 2 of an inch (12.7 mm) in the least dimension.
312.12.1 Meter Boxes. Meter boxes shall be con structed in such a manner as to restrict rodents or vermin from entering a building by following the service pipes from the box into the building. 312.12.2 Metal Collars. In or on buildings where openings have been made in walls, floors, or ceilings for the passage of pipes, such openings shall be closed and protected by the installation of approved metal collars securely fastened to the adjoining structure. 312.12.3 Tub Waste Openings. Tub waste openings in framed construction to crawl spaces at or below the first floor shall be protected by the installation of approved metal collars or metal screen securely fastened to the adjoining structure with no opening exceeding [1] ⁄ 2 of an inch (12.7 mm) in the least dimension.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
▸Chapter 3 — GENERAL REGULATIONS
Overview- 301.1 Applicability.
- 301.2 Minimum Standards.
- 301.3 Alternate Materials and Methods of Construction Equivale…
- 301.4 Flood Hazard Areas.
- 301.5 Alternative Engineered Design.
- 301.6 Tall Wood (Mass Timber) Buildings.
- 301.7 One- and Two-Family Dwellings. [HCD 1]
- 301.8 OSHPD 1R. [OSHPD 1R]
- 302.1 General.
- 303.1 General.
- 304.1 General.
- 305.1 Unlawful Practices.
- 306.1 Detrimental Wastes.
- 306.2 Safe Discharge.
- 307.1 System.
- 307.2 Ownership.
- 308.1 General.
- 309.1 Engineering Practices.
- 309.2 Concealing Imperfections.
- 309.3 Burred Ends.
- 309.4 Installation Practices.
- 309.5 Sound Transmission.
- 309.6 Dead Legs.
- 310.1 Fittings.
- 310.2 Drainage and Vent Piping.
- 310.3 Waste Connection.
- 310.4 Use of Vent and Waste Pipes.
- 310.5 Obstruction of Flow.
- 310.6 Dissimilar Metals.
- 310.7 Direction of Flow.
- 310.8 Screwed Fittings.
- 310.9 Female Plastic Connections.
- 310.10 ABS and PVC Transition Joints.
- 310.11 [OSHPD 1, 2, 3, 4 & 5]
- 310.12 [OSHPD 1, 3, 4 & 5]
- 310.13 [SFM]
- 310.14 Services/Systems and Utilities. [OSHPD 1, 2, 4
- 310.15 Telephone and Data Equipment Rooms.
- 311.1 General.
- 312.1 General.
- 312.2 Installation.
- 312.3 Building Sewer and Drainage Piping.
- 312.4 Corrosion, Erosion, and Mechanical Damage.
- 312.5 Protectively Coated Pipe.
- 312.6 Freezing Protection.
- 312.7 Fire-Resistant Construction.
- 312.8 Waterproofing of Openings.
- 312.9 Steel Nail Plates.
- 312.10 Sleeves.
- 312.11 Structural Members.
- 312.12 Rodentproofing.
- 313.1 General.
- 313.2 Material.
- 313.3 Suspended Piping.
- 313.4 Alignment.
- 313.5 Underground Installation.
- 313.6 Hanger Rod Sizes.
- 313.7 Gas Piping.
- 313.8 [OSHPD 1, 2, 3, 4 & 5]
- 314.1 Trenches.
- 314.2 Tunneling and Driving.
- 314.3 Open Trenches.
- 314.4 Excavations.
- 315.1 Unions.
- 315.2 Prohibited Joints and Connections.
- 316.1 General.
- 317.1 General.
- 318.1 General.
- 318.2 Pressure Tests (10 psi or less).
- 318.3 Pressure Tests (greater than 10 psi to 100 psi).
- 318.4 Pressure Tests (exceeding 100 psi).
- 318.5 Pressure Range.
- 319.1 General.
- 320.1 General.
- 323.0 Plumbing Equipment Schedules. [OSHPD 1, 2,
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
- Appendix O — NON-SEWERED SANITATION SYSTEMS
- Appendix P — PROFESSIONAL QUALIFICATIONS
- Appendix Q — INDOOR HORTICULTURAL FACILITIES
- Appendix R — TINY HOUSES
- Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS