Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
1603.5 Rainwater Storage Tanks. Rainwater storage tanks
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
shall comply with IAPMO/ANSI Z1002 and be installed in accordance with Section 1603.6 through Section 1603.12.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
▸Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
Overview- 1601.1 Applicability. The provisions of this chapter shall
- 1601.2 System Design. Rainwater catchment systems shall
- 1601.3 Permit. It shall be unlawful for a person to construct,
- 1601.4 Component Identification. System components
- 1601.5 Maintenance and Inspection. Rainwater catchment systems…
- 1601.6 Operation and Maintenance Manual. An operation and main…
- 1601.7 Minimum Water Quality Requirements. The
- 1601.8 Material Compatibility. Rainwater catchment systems sha…
- 1601.9 System Controls. Controls for pumps, valves, and
- 1601.10 Separation Requirements. Underground rainwater catchme…
- 1601.11 Abandonment. Rainwater catchment systems that
- 1601.12 Sizing. Unless otherwise provided for in this chapter,…
- 1602.1 General. The installation, construction, alteration,
- 1602.2 Plumbing Plan Submission. No permit for a
- 1602.3 System Changes. No changes or connections shall
- 1602.4 Connections to Potable or Reclaimed (Recy-
- 1602.5 Initial Cross-Connection Test. Where a portion
- 1602.6 Sizing. The design and size of rainwater drains, gutter…
- 1602.7 Rainwater Catchment System Materials. Rain- 1603.3 Rain…
- 1602.8 Rainwater Catchment System Color and
- 1603.4 Minimum Water Quality. The minimum water
- 1602.9 Deactivation and Drainage for Cross-Connec- shall be in…
- 1603.1 Rainwater Catchment Systems. The design and
- 1603.2 Outside Hose Bibbs. Outside hose bibbs shall be infecti…
- 1603.5 Rainwater Storage Tanks. Rainwater storage tanks
- 1603.6 Location. Rainwater storage tanks shall be permitted to…
- 1603.7 Above Grade. Above grade, storage tanks shall be
- 1603.9 Drainage and Overflow. Rainwater storage tanks
- 1603.10 Opening and Access Protection. Rainwater
- 1603.11 Marking. Rainwater tanks shall be permanently
- 1603.12 Storage Tank Venting. Where venting using
- 1603.13 Pumps. Pumps serving rainwater catchment systems shall…
- 1605.1 General. Rainwater catchment systems shall be
- 1605.2 Supply System Inspection and Test. Rainwater
- 1605.3 Cross-Connection Inspection and Testing. An
- 1603.14 Roof Drains. Primary and secondary roof drains,
- 1603.15 Water Quality Devices and Equipment.
- 1603.16 Freeze Protection. Tanks and piping installed in
- 1603.17 Debris Removal. The rainwater catchment conveyance sys…
- 1603.18 Required Filters. A filter permitting the passage
- 1603.19 Roof Gutters. Gutters shall maintain a minimum
- 1603.20 Rainwater Diversion Valves. Rainwater diversion valves…
- 1604.1 General. Signs in buildings using rainwater shall be
- 1604.2 Commercial, Industrial, Institutional and Res-
- 1604.3 Equipment Room Signs. Each equipment room
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
- Appendix O — NON-SEWERED SANITATION SYSTEMS
- Appendix P — PROFESSIONAL QUALIFICATIONS
- Appendix Q — INDOOR HORTICULTURAL FACILITIES
- Appendix R — TINY HOUSES
- Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS