1204.6 Flow Directions. Flow directions shall be indicated
California Mechanical Code (Title 24, Part 4) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
on the system.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Mechanical Code (Title 24, Part 4)
California Mechanical Code (Title 24, Part 4)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — VENTILATION AIR
- Chapter 5 — EXHAUST SYSTEMS
- Chapter 6 — DUCT SYSTEMS
- Chapter 7 — COMBUSTION AIR
- Chapter 8 — CHIMNEYS AND VENTS
- Chapter 9 — INSTALLATION OF SPECIFIC APPLIANCES
- Chapter 10 — BOILERS AND PRESSURE VESSELS
- Chapter 11 — REFRIGERATION
▸Chapter 12 — HYDRONICS
Overview- 1201.1 Applicability. This chapter shall apply to hydronic
- 1201.2 Insulation. Surfaces within reach of building occupants…
- 1201.3 Water Hammer. The piping system shall be
- 1201.4 Terminal Units. Terminal units, valves, and flow
- 1201.5 Return-Water Low-Temperature Protection.
- 1202.1 Prohibited Sources. Hydronic systems or parts
- 1202.2 Chemical Injection. Where systems include an
- 1202.3 Compatibility. Fluids used in hydronic systems
- 1203.1 Heat Source. The heat source shall be sized to the
- 1203.2 Dual Purpose Water Heater. Water heaters utilized for c…
- 1203.3 Tankless Water Heaters. Tankless water heaters
- 1204.1 General. In buildings where potable water and nonpotabl…
- 1204.2 Color and Information. Each system shall be identified …
- 1204.3 Potable Water. Potable water systems shall be identifie…
- 1204.4 Nonpotable Water. Nonpotable water systems
- 1204.5 Location of Piping Identification. The background
- 1204.6 Flow Directions. Flow directions shall be indicated
- 1205.1 Operating Instructions. Operating and maintenance
- 1205.2 Pressure Testing. System piping and components
- 1205.3 Flushing. Heating and cooling sources, system piping an…
- 1206.1 General. Each closed hydronic system shall be protected…
- 1206.2 Discharge Piping. The discharge piping serving a
- 1207.1 General. Heating appliances, equipment, safety and
- 1207.2 Boilers. Boilers and their control systems shall comply…
- 1207.3 Dual-Purpose Water Heaters. Water heaters used
- 1207.4 Solar Heat Collector Systems. Solar water heating syste…
- 1208.1 General. Circulators and pumps shall be selected
- 1208.2 Mounting. The circulator or pump shall be installed
- 1208.3 Sizing. The selection and sizing of a circulator or
- 1209.1 General. An expansion tank shall be installed in each
- 1209.2 Installation. Expansion tanks shall be accessible for
- 1209.3 Open-Type Expansion Tanks. Open type expansion tanks sh…
- 1209.4 Closed-Type Tanks. Closed-type expansion tanks
- 1209.5 Sizing. Expansion tanks shall be sized to accept the
- 1210.1 Piping, Tubing, and Fittings. Hydronic pipe and
- 1210.2 Expansion and Contraction. Pipe and tubing shall
- 1210.3 Hangers and Supports. Pipe and tubing shall be
- 1210.4 Oxygen Diffusion Corrosion. PEX and PE-RT tubing in clo…
- 1211.1 General. Joints and connections shall be of an
- 1211.2 Chlorinated Polyvinyl Chloride (CPVC) Pipe.
- 1211.3 CPVC/AL/CPVC Plastic Pipe and Joints. Joints
- 1211.4 Copper or Copper Alloy Pipe and Tubing.
- 1211.5 Cross-Linked Polyethylene (PEX) Pipe. Joints
- 1211.6 Cross-Linked Polyethylene/Aluminum/Cross-
- 1211.7 Ductile Iron Pipe. Joints between ductile iron pipe
- 1211.8 Polyethylene (PE) Plastic Pipe/Tubing. Joints
- 1211.9 Polyethylene/Aluminum/Polyethylene (PE-AL-
- 1211.10 Polyethylene of Raised Temperature (PE-RT).
- 1211.11 Polypropylene (PP) Pipe. Joints between
- 1211.12 Polyvinyl Chloride (PVC) Pipe. Joints between
- 1211.13 Steel Pipe and Tubing. Joints between steel pipe
- 1211.14 Joints Between Various Materials. Joints
- 1212.1 General. Valves shall be rated for the operating temper…
- 1212.2 Where Required. Valves shall be installed in
- 1212.3 Heat Exchanger. Isolation valves shall be installed
- 1212.4 Pressure Vessels. Isolation valves shall be installed
- 1212.5 Pressure Reducing Valves. Isolation valves shall
- 1212.6 Equipment, Components, and Appliances. Serviceable equi…
- 1212.7 Expansion Tank. Isolation valves shall be installed
- 1212.8 Flow Balancing Valves. Where flow balancing
- 1212.9 Mixing or Temperature Control Valves. Where
- 1212.10 Thermosiphoning. An approved type check valve
- 1212.11 Air Removal Device or Air Vents. Isolation valves
- 1213.1 Water Temperature Controls. A heat source or system of …
- 1213.2 Operating Steam Controls. A steam heat source or
- 1213.3 Occupied Spaces. A temperature-sensing device
- 1213.4 Simultaneous Operation. Radiant heating and cooling sys…
- 1213.5 Temperature Reading. A temperature gauge or
- 1214.1 Balancing. A means for balancing distribution
- 1214.2 Low-Water Control. Direct-fired heat sources
- 1214.3 Flow-Sensing Devices. A direct-fired heat source,
- 1214.4 Automatic Makeup Fluid. Where an automatic
- 1214.5 Differential Pressure Regulation. Provisions
- 1214.6 Air-Removal Device. Provision shall be made for
- 1214.7 Air-Separation Device. To assist with the removal
- 1214.8 Secondary Loops. Secondary loops that are isolated from…
- 1215.1 General. Based on the system design, the heat-distribut…
- 1215.2 Installation. Heat-distribution units shall be
- 1215.3 Freeze Protection. Hydronic systems and components shal…
- 1215.4 Balancing. System loops shall be installed so that
- 1215.5 Heat Transfer Fluid. The ignitable flash point of
- 1216.1 Steam Traps. For other than one-pipe steam systems, eac…
- 1216.2 Sloping for Two-Pipe System. Two-pipe steam
- 1216.3 Sloping for One-Pipe System. One-pipe steam
- 1216.4 Automatic Air Vents. Steam automatic air vents
- 1216.5 Condensate Flow. System piping shall be installed
- 1216.6 Steam-Distribution Piping. Where multi-row elements are…
- 1217.1 Installation. Radiant heating and cooling systems
- 1217.2 Radiant Under-Floor Heating. Floor finished surface tem…
- 1217.3 Radiant Cooling Systems. Radiant cooling systems shall …
- 1217.4 Tube Placement. Hydronic radiant system tubing
- 1217.6 Joist Systems and Subfloors. Where tubing is
- 1217.7 Wall and Ceiling Panels. Where piping is installed
- 1217.5 Poured Floor Structural Concrete Slab Sys-
- 1219.1 General. Domestic hot-water heat exchangers,
- 1220.1 Use of Chemical Additives and Corrosive Flu-
- 1220.2 Types of Tube Fasteners. Tubing that is embedded within…
- 1220.3 Spacing of Tube Fasteners. The maximum spacing between …
- 1217.8 Radiant Heating and Cooling Panels. Radiant
- 1218.1 General. Systems utilizing heat exchangers shall
- 1220.4 Snow and Ice Melt Controls. An automatic thermostatical…
- 1220.5 Hydronic Makeup Air Units. Hydronic makeup
- 1221.1 General. Piping, fittings, and connections shall be
- 1221.2 Embedded Piping Materials and Joints. Piping embedded i…
- 1221.3 Pressure Testing. Piping to be embedded in concrete sha…
- 1221.4 System Drainage. Hydronic piping systems shall
- 1221.5 Condensate Drainage. Condensate drains from
- 1221.6 Clearance to Combustibles. Hydronic piping
- Chapter 13 — FUEL GAS PIPING
- Chapter 14 — PROCESS PIPING
- Chapter 15 — SOLAR ENERGY SYSTEMS
- Chapter 16 — STATIONARY POWER PLANTS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RESIDENTIAL PLAN EXAMINER REVIEW FORM FOR HVAC SY…
- Appendix B — PROCEDURES TO BE FOLLOWED TO PLACE GAS EQUIPMENT …
- Appendix C — INSTALLATION AND TESTING OF OIL (LIQUID) FUEL-FIR…
- Appendix D — FUEL SUPPLY: MANUFACTURED/MOBILE HOME PARKS AND R…
- Appendix E — SUSTAINABLE PRACTICES
- Appendix F — GEOTHERMAL ENERGY SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS AND OUTDOOR COMBUSTION …
- Appendix H — EXAMPLE CALCULATION OF OUTDOOR AIR RATE