Chapter 23 — WOOD

Section 2306

California Building Code (Title 24, Part 2) · 2022 edition · updated 2026-09-12 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

2306.1 Allowable stress design.

The design and construction of wood elements in structures using allowable stress design shall be in accordance with the applicable standards listed in Table 2306.1.

2306.1.1 Joists and rafters. The design of rafter spans is permitted to be in accordance with the AWC STJR.

2306.1.2 Plank and beam flooring. The design of plank and beam flooring is permitted to be in accordance with the AWC Wood Construction Data No. 4.

2306.1.3 Treated wood stress adjustments. The allowable unit stresses for preservative-treated wood need not be adjusted for treatment, but are subject to other adjustments.

The allowable unit stresses for fire-retardant-treated wood, including fastener values, shall be developed from an approved method of investigation that considers the effects of anticipated temperature and humidity to which

the fire-retardant-treated wood will be subjected, the type of treatment and the redrying process. Other adjustments are applicable except that the impact load duration shall not apply.

2306.1.4 Lumber decking. The capacity of lumber decking arranged according to the patterns described in Section 2304.9.2 shall be the lesser of the capacities determined for moment and deflection according to the formulas in Table 2306.1.4.

2306.2 Wood-frame diaphragms.

Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall be permitted. The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design.

2306.2.1 Gypsum board diaphragm ceilings. Gypsum board diaphragm ceilings shall be in accordance with Section 2508.6.

23-28 2022 CALIFORNIA BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

TABLE 2306.1 STANDARDS FOR DESIGN AND CONSTRUCTION OF WOOD ELEMENTS IN STRUCTURES USING ALLOWABLE STRESS DESIGN

WOOD

TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING

PATTERN ALLOWABLE AREA LOADa
PATTERN Moment Deflection
Simple span wb
8_Fb_
′_d_2
_l_26
--------------
=
w_Δ
384Δ_E

5_l_4
------------------_d_3
12
-----
=
Two-span continuous wb
8_Fb_
′_d_2
_l_26
----------------
=
w_Δ
185Δ_E

_l_4
------------------_d_3
12
-----
=
Combination simple-
and two-span continu-
ous
wb
8_Fb_
′_d_2
_l_26
----------------
=
w_Δ
131Δ_E

_l_4
------------------_d_3
12
-----
=
Cantilevered pieces
intermixed

wb
20_Fb_
′_d_2
3_l_26
-------------------
=
w_Δ
105Δ_E

_l_4
------------------_d_3
12
-----
=
Controlled random layup Controlled random layup Controlled random layup
Mechanically lami-
nated decking
wb
20_Fb_
′_d_2
3_l_26
-----------------
=
w_Δ
100Δ_E

_l_4
------------------ _d_3
12
-----
=
2-inch decking wb
20_Fb_
′_d_2
3_l_26
-----------------
=
w_Δ
100Δ_E

_l_4
------------------ _d_3
12
-----
=
3-inch and 4-inch
decking
wb
8_Fb_
′_d_2
_l_26
--------------
=
w_Δ
116Δ_E

_l_4
------------------ _d_3
12
-----
=

For SI: 1 inch = 25.4 mm. a. wb = Allowable total uniform load limited by moment.

w Δ = Allowable total uniform load limited by deflection . d = Actual decking thickness. l = Span of decking. Fb ′ = Allowable bending stress adjusted by applicable factors. E ′ = Modulus of elasticity adjusted by applicable factors.

2306.3 Wood-frame shear walls.

Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall be permitted. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.

STANDARDS
PROMULGATOR
STANDARD TITLE
American Wood Council American Wood Council American Wood Council
ANSI/AWC NDS National Design Specification for
Wood Construction
SDPWS Special Design Provisions for Wind
and Seismic
American Society of Agricultural and Biological Engineers
ASABE EP 484.3 Diaphragm Design of Metal-clad,
Wood-Frame Rectangular Buildings
ASABE EP 486.3 Shallow Post and Pier Foundation
Design
ASABE EP 559.1 Design Requirements and Bending
Properties for Mechanically
Laminated Wood Assemblies
APA—The Engineered Wood Association APA—The Engineered Wood Association APA—The Engineered Wood Association
ANSI 117 Standard Specifications for Structural
Glued Laminated Timber of
Softwood Species
ANSI A190.1 Structural Glued Laminated Timber
Panel Design Specification
Plywood Design Specification
Supplement 1—Design &
Fabrication of Plywood Curved Panel
Plywood Design Specification
Supplement 2—Design &
Fabrication of Glued Plywood-lumber
Beams
Plywood Design Specification
Supplement 3—Design & Fabrication
of Plywood Stressed-skin Panels
Plywood Design Specification
Supplement 4—Design & Fabrication
of Plywood Sandwich Panels
Plywood Design Specification
Supplement 5—Design & Fabrication
of All-plywood Beams
APA T300 Glulam Connection Details
APA S560 Field Notching and Drilling of Glued
Laminated Timber Beams
APA S475 Glued Laminated Beam Design Tables
APA X450 Glulam in Residential Construction
APA X440 Product and Application Guide:
Glulam
APA R540 Builders Tips: Proper Storage and
Handling of Glulam Beams
Truss Plate Institute, Inc. Truss Plate Institute, Inc. Truss Plate Institute, Inc.
TPI 1 National Design Standard for Metal
Plate Connected Wood Truss
Construction
West Coast Lumber Inspection Bureau West Coast Lumber Inspection Bureau West Coast Lumber Inspection Bureau
AITC 104 Typical Construction Details
AITC 110 Standard Appearance Grades for
Structural Glued Laminated Timber
AITC 113 Standard for Dimensions of Structural
Glued Laminated Timber
AITC 119 Standard Specifications for Structural
Glued Laminated Timber of Hard-
wood Species
AITC 200 Inspection Manual

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINE a FOR WIND OR SEISMIC LOADING f

PANEL
GRADE
STAPLE
LENGTH
AND GAGEd
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBERS AT
ADJOINING PANEL
EDGES AND
BOUNDARIESe
(inches)
BLOCKED DIAPHRAGMS UNBLOCKED DIAPHRAGMS
PANEL
GRADE
STAPLE
LENGTH
AND GAGEd
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBERS AT
ADJOINING PANEL
EDGES AND
BOUNDARIESe
(inches)
Fastener spacing (inches) at
diaphragm boundaries (all cases) at
continuous panel edges parallel to
load (Cases 3, 4), and at all panel
edges (Cases 5, 6)b
Fastener spacing (inches) at
diaphragm boundaries (all cases) at
continuous panel edges parallel to
load (Cases 3, 4), and at all panel
edges (Cases 5, 6)b
Fastener spacing (inches) at
diaphragm boundaries (all cases) at
continuous panel edges parallel to
load (Cases 3, 4), and at all panel
edges (Cases 5, 6)b
Fastener spacing (inches) at
diaphragm boundaries (all cases) at
continuous panel edges parallel to
load (Cases 3, 4), and at all panel
edges (Cases 5, 6)b
Fasteners spaced 6 inches
max. at supported edgesb
Fasteners spaced 6 inches
max. at supported edgesb
PANEL
GRADE
STAPLE
LENGTH
AND GAGEd
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBERS AT
ADJOINING PANEL
EDGES AND
BOUNDARIESe
(inches)
6 4 21/2
c
2c Case 1 (No
unblocked
edges or
continuous
joints parallel
to load)
All other
configurations
(Cases 2, 3, 4, 5
and 6)g
PANEL
GRADE
STAPLE
LENGTH
AND GAGEd
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBERS AT
ADJOINING PANEL
EDGES AND
BOUNDARIESe
(inches)
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
Fastener spacing (inches) at other
panel edges (Cases 1, 2, 3 and 4)b
PANEL
GRADE
STAPLE
LENGTH
AND GAGEd
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBERS AT
ADJOINING PANEL
EDGES AND
BOUNDARIESe
(inches)
6 6 4 3 3 3
Structural I
grades
11/2 16 gage 1 3/8 2 175 235 350 400 155 115
Structural I
grades
11/2 16 gage 1 3/8 3 200 265 395 450 175 130
Structural I
grades
11/2 16 gage 1 15/32 2 175 235 350 400 155 120
Structural I
grades
11/2 16 gage 1 15/32 3 200 265 395 450 175 130
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 3/8 2 160 210 315 360 140 105
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 3/8 3 180 235 355 400 160 120
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 7/16 2 165 225 335 380 150 110
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 7/16 3 190 250 375 425 165 125
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 15/32 2 160 210 315 360 140 105
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 15/32 3 180 235 355 405 160 120
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 19/32 2 175 235 350 400 155 115
Sheathing,
single floor
and other
grades cov-
ered in DOC
PS 1 and PS
2
11/2 16 gage 1 19/32 3 200 265 395 450 175 130

For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of lumber in ANSI/AWC NDS. (2) For staples find shear value from table for Structural I

panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Space fasteners maximum 12 inches on center along intermediate framing members (6 inches on center where supports are spaced 48 inches on center). c. Framing at adjoining panel edges shall be 3 inches nominal or wider. d. Staples shall have a minimum crown width of 7 /16 inch and shall be installed with their crowns parallel to the long dimension of the framing members. e. The minimum nominal width of framing members not located at boundaries or adjoining panel edges shall be 2 inches. f. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table shall be multiplied by 0.63 or 0.56,

respectively. g. For Case 1 through 6 descriptions see Figure 2306.2(1).

FIGURE 2306.2(1) CASES 1 THROUGH 6 FOR USE WITH TABLE 2306.2(1)

23-30 2022 CALIFORNIA BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS

UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF

DOUGLAS FIR-LARCH OR SOUTHERN PINE a FOR WIND OR SEISMIC LOADING b, g, h

PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
BLOCKED DIAPHRAGMS
PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
Cases 1 and 2d Cases 1 and 2d Cases 1 and 2d Cases 1 and 2d Cases 1 and 2d Cases 1 and 2d
PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
Fastener Spacing Per Line at Boundaries
(inches)i
Fastener Spacing Per Line at Boundaries
(inches)i
Fastener Spacing Per Line at Boundaries
(inches)i
Fastener Spacing Per Line at Boundaries
(inches)i
Fastener Spacing Per Line at Boundaries
(inches)i
Fastener Spacing Per Line at Boundaries
(inches)i
PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
4 4 21/2 21/2 2 2
PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
Fastener Spacing Per Line at Other Panel Edges
(inches)i
Fastener Spacing Per Line at Other Panel Edges
(inches)i
Fastener Spacing Per Line at Other Panel Edges
(inches)i
Fastener Spacing Per Line at Other Panel Edges
(inches)i
Fastener Spacing Per Line at Other Panel Edges
(inches)i
Fastener Spacing Per Line at Other Panel Edges
(inches)i
PANEL
GRADEc
STAPLE
GAGEf
MINIMUM
FASTENER
PENETRATION
IN FRAMING
(inches)
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM NOMINAL
WIDTH OF FRAMING
MEMBER AT ADJOINING
PANEL EDGES AND
BOUNDARIESe
LINES OF
FASTENERS
6 4 4 3 3 2
Structural I
grades
14 gage
staples
2 15/32 3 2 600 600 860 960 1,060 1,200
Structural I
grades
14 gage
staples
2 15/32 4 3 860 900 1,160 1,295 1,295 1,400
Structural I
grades
14 gage
staples
2 19/32 3 2 600 600 875 960 1,075 1,200
Structural I
grades
14 gage
staples
2 19/32 4 3 875 900 1,175 1,440 1,475 1,795
Sheathing
single floor
and other
grades cov-
ered in DOC
PS 1 and PS 2
14 gage
staples
2 15/32 3 2 540 540 735 865 915 1,080
Sheathing
single floor
and other
grades cov-
ered in DOC
PS 1 and PS 2
14 gage
staples
2 15/32 4 3 735 810 1,005 1,105 1,105 1,195
Sheathing
single floor
and other
grades cov-
ered in DOC
PS 1 and PS 2
14 gage
staples
2 19/32 3 2 600 600 865 960 1,065 1,200
Sheathing
single floor
and other
grades cov-
ered in DOC
PS 1 and PS 2
14 gage
staples
2 19/32 4 3 865 900 1,130 1,430 1,370 1,485
Sheathing
single floor
and other
grades cov-
ered in DOC
PS 1 and PS 2
14 gage
staples
2 23/32 4 3 865 900 1,130 1,490 1,430 1,545

For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of framing lumber in ANSI/AWC NDS. (2) For staples, find shear value from table for

Structural I panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Fastening along intermediate framing members: Space fasteners not greater than 12 inches on center, except 6 inches on center for spans greater than 32

inches. c. Panels conforming to DOC PS 1 or PS 2. d. This table gives shear values for Cases 1 and 2 as shown in Table 2306.2(1). The values shown are applicable to Cases 3, 4, 5 and 6 as shown in Table

2306.2(1), providing fasteners at all continuous panel edges are spaced in accordance with the boundary fastener spacing. e. The minimum nominal depth of framing members shall be 3 inches nominal. The minimum nominal width of framing members not located at boundaries or

adjoining panel edges shall be 2 inches. f. Staples shall have a minimum crown width of 7 /16 inch, and shall be installed with their crowns parallel to the long dimension of the framing members. g. High-load diaphragms shall be subject to special inspection in accordance with Section 1705.5.1. h. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table shall be multiplied by 0.63 or 0.56,

respectively. i. For fastener spacing diagrams see Figure 2306.2(2).

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

For SI: 1 inch = 25.4 mm.

FIGURE 2306.2(2) FASTENER SPACING DIAGRAMS FOR USE WITH TABLE 2306.2(2)

23-32 2022 CALIFORNIA BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH

FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE a FOR WIND OR SEISMIC LOADING b, f, g, i

PANEL GRADE MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM
FASTENER
PENETRATION IN
FRAMING
(inches)
PANELS
APPLIED
DIRECT TO
FRAMING
PANELS APPLIED OVER 1/" OR 5/"
2 8
GYPSUM SHEATHING
PANEL GRADE MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM
FASTENER
PENETRATION IN
FRAMING
(inches)
Staple
length
and gageh
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
Staple
length and
gageh
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
Fastener spacing at panel edges
(inches)
PANEL GRADE MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
MINIMUM
FASTENER
PENETRATION IN
FRAMING
(inches)
Staple
length
and gageh
(inches)
6 4 3 2d 2d 6 4 3 2d
Structural I
sheathing
3/8 1 11/2 16
Gage
155 235 315 400 2 16 Gage 155 235 310 400
Structural I
sheathing
7/16 7/16 7/16 170 260 345 440 440 155 235 310 400
Structural I
sheathing
15/32 15/32 15/32 185 280 375 475 475 155 235 300 400
Sheathing, ply-
wood sidinge
except Group 5
Species,
ANSI/APA PRP
210sidinge
5/16
c or1/4
c
1 11/2 16
Gage
145 220 295 375 2 16 Gage 110 165 220 285
Sheathing, ply-
wood sidinge
except Group 5
Species,
ANSI/APA PRP
210sidinge
3/8 3/8 3/8 140 210 280 360 360 140 210 280 360
Sheathing, ply-
wood sidinge
except Group 5
Species,
ANSI/APA PRP
210sidinge
7/16 7/16 7/16 155 230 310 395 395 140 210 280 360
Sheathing, ply-
wood sidinge
except Group 5
Species,
ANSI/APA PRP
210sidinge
15/32 15/32 15/32 170 255 335 430 430 140 210 280 360
Sheathing, ply-
wood sidinge
except Group 5
Species,
ANSI/APA PRP
210sidinge
19/32 19/32 13/4 16
Gage
185 280 375 475

For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of lumber in ANSI/AWC NDS. (2) For staples find shear value from table for Structural I

panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Panel edges backed with 2-inch nominal or wider framing. Install panels either horizontally or vertically. Space fasteners maximum 6 inches on center along

intermediate framing members for 3 /8-inch and 7 /16-inch panels installed on studs spaced 24 inches on center. For other conditions and panel thickness, space fasteners maximum 12 inches on center on intermediate supports. c. 3 /8-inch panel thickness or siding with a span rating of 16 inches on center is the minimum recommended where applied directly to framing as exterior siding.

For grooved panel siding, the nominal panel thickness is the thickness of the panel measured at the point of fastening. d. Framing at adjoining panel edges shall be 3 inches nominal or wider. e. Values apply to all-veneer plywood. Thickness at point of fastening on panel edges governs shear values. f. Where panels are applied on both faces of a wall and fastener spacing is less than 6 inches on center on either side, panel joints shall be offset to fall on

different framing members, or framing shall be 3 inches nominal or thicker at adjoining panel edges. g. In Seismic Design Category D, E or F, where shear design values exceed 350 pounds per linear foot, all framing members receiving edge fastening from

abutting panels shall be not less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See AWC SDPWS for sill plate size and anchorage requirements. h. Staples shall have a minimum crown width of 7 /16 inch and shall be installed with their crowns parallel to the long dimension of the framing members. i. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table shall be multiplied by 0.63 or 0.56,

respectively.

TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD

CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY a, b, c, d, e

THICKNESS AND GRADE
(inches)
STAPLE GAGE AND
DIMENSIONS
ALLOWABLE SHEAR VALUE (pounds per linear foot)
STAPLE SPACING AT PANEL EDGES (inches)a
THICKNESS AND GRADE
(inches)
STAPLE GAGE AND
DIMENSIONS
4 3 2
1/2 or25/32 Structural No. 16 gage galvanized
staple,7/16″ crown 13/4
inches long
150 200 225
1/2 or25/32 Structural No. 16 gage galvanized
staple, 1″ crown 13/4
inches long
220 290 325

For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. Fiberboard sheathing shall not be used to brace concrete or masonry walls. b. Panel edges shall be backed with 2-inch or wider framing of Douglas Fir-larch or Southern pine. For framing of other species: (1) Find specific gravity for

species of framing lumber in ANSI/AWC NDS. (2) For staples, multiply the shear value from the table by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. c. Values shown are for fiberboard sheathing on one side only with long panel dimension either parallel or perpendicular to studs. d. Fastener shall be spaced 6 inches on center along intermediate framing members. e. Values are not permitted in Seismic Design Category D, E or F.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND

PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES

TYPE OF MATERIAL THICKNESS OF
MATERIAL
WALL
CONSTRUCTION
STAPLE SPACINGb
MAXIMUM
(inches)
SHEAR
VALUEa, c
(plf)
MINIMUM
STAPLE SIZE f, g
1.
Expanded metal or
woven wire lath and
Portland cement plaster
7/8″ Unblocked 6 180 No. 16 gage galv. staple,7/8″ legs
2.
Gypsum lath, plain or
perforated
3/8″ lath and1/2″
plaster
Unblocked 5 100 No. 16 gage galv. staple, 11/8″ long
3.
Gypsum sheathing
1/2″ × 2′ × 8′ Unblocked 4 75 No. 16 gage galv. staple, 13/4″ long
3.
Gypsum sheathing
1/2″ ×4′ Blockedd
Unblocked
4
7
175
100
175
100
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Unblockedd 7 75 No. 16 gage galv. staple, 11/2″ long
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Unblockedd 4 110 110
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Unblocked 7 100 100
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Unblocked 4 125 125
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Blockede 7 125 125
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
1/2″ Blockede 4 150 150
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
5/8″ Unblockedd 7 115 No. 16 gage galv. staple, 15/8″ long
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
5/8″ Unblockedd 4 145 145
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
5/8″ Blockede 7 145 145
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
5/8″ Blockede 4 175 175
4.
Gypsum board, gypsum
veneer base or water-
resistant gypsum
backing board
5/8″ Blockede
Two-ply
Base ply: 9
Face ply: 7
250 No. 16 gage galv. staple 15/8″ long
No. 15 gage galv. staple, 21/4″ long

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per foot = 14.5939 N/m. a. These shear walls shall not be used to resist loads imposed by masonry or concrete walls (see AWC SDPWS). Values shown are for short-term loading due to

wind or seismic loading. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. Values shown shall be reduced 25 percent for normal loading. b. Applies to fastening at studs, top and bottom plates and blocking. c. Except as noted, shear values are based on a maximum framing spacing of 16 inches on center. d. Maximum framing spacing of 24 inches on center. e. All edges are blocked, and edge fastening is provided at all supports and all panel edges. f. Staples shall have a minimum crown width of 7 /16 inch, measured outside the legs, and shall be installed with their crowns parallel to the long dimension of the

framing members. g. Staples for the attachment of gypsum lath and woven-wire lath shall have a minimum crown width of 3 /4 inch, measured outside the legs.

23-34 2022 CALIFORNIA BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

WOOD

2308.2.3 Allowable loads. Loads shall be in accordance with Chapter 16 and shall not exceed the following:

  1. Average dead loads shall not exceed 15 psf (718 N/m 2 ) for combined roof and ceiling, exterior walls, floors and partitions.

Exceptions:

  1. Subject to the limitations of Section 2308.6.10, stone or masonry veneer up to the less of 5 inches (127 mm) thick or 50 pounds per square foot (2395 N/m 2 ) and installed in accordance with Chapter 14 is permitted to a height of 30 feet (9144 mm) above a noncombustible foundation, with an additional 8 feet (2439) permitted for gable ends.

  2. Concrete or masonry fireplaces, heaters and chimneys shall be permitted in accordance with the provisions of this code.

  3. Live loads shall not exceed 40 psf (1916 N/m 2 ) for floors.

Exception: Live loads for concrete slab-onground floors in Risk Categories I and II shall be not more than 125 psf.

  1. Ground snow loads shall not exceed 50 psf (2395 N/m 2 ).

2308.2.4 Basic wind speed. V shall not exceed 130 miles per hour (57 m/s) (3-second gust).

Exceptions:

  1. V shall not exceed 140 mph (63 m/s) (3-second gust) for buildings in Exposure Category B that are not located in a hurricane-prone region.

  2. Where V exceeds 130 mph (3-second gust), the provisions of either AWC WFCM or ICC 600 are permitted to be used.

2308.2.5 Allowable roof span. Ceiling joist and rafter framing constructed in accordance with Section 2308.7 and trusses shall not span more than 40 feet (12 192 mm) between points of vertical support. A ridge board in accordance with Section 2308.7 or 2308.7.3.1 shall not be considered a vertical support.

2308.2.6 Risk category limitation. The use of the provisions for conventional light-frame construction in this section shall not be permitted for Risk Category IV buildings assigned to Seismic Design Category B, C, D or F.

2308.2.7 Additional requirements [DSA-SS & DSA- SS/CC and OSHPD 1R, 2 & 5] The use of conventional light-frame construction provisions in this section is per- mitted, subject to the following conditions:

1. The design and construction shall also comply with Section 2304 and Section 2305.

2. In conjunction with the use of provisions in Section

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Building Code (Title 24, Part 2)
California Building Code (Title 24, Part 2)
  1. Chapter 2 — DEFINITIONS AND ABBREVIATIONS
  2. Appendix G — FLOOD-RESISTANT
  3. Appendix L — EARTHQUAKE RECORDING
  4. Appendix M — TSUNAMI-GENERATED
  5. Appendix N — REPLICABLE
  6. Appendix O — PERFORMANCE-BASED
  7. Chapter 1 — SCOPE AND ADMINISTRATION
  8. Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
  9. Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
  10. Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
  11. Chapter 6 — TYPES OF CONSTRUCTION
  12. Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
  13. Chapter 7A — MATERIALS AND CONSTRUCTION
  14. Chapter 8 — INTERIOR FINISHES
  15. Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
  16. Chapter 10 — MEANS OF EGRESS
  17. Chapter 11A — HOUSING ACCESSIBILITY
  18. Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
  19. Chapter 12 — INTERIOR ENVIRONMENT
  20. Chapter 14 — EXTERIOR WALLS
  21. Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
  22. Chapter 16 — STRUCTURAL DESIGN
  23. Chapter 16A — STRUCTURAL DESIGN
  24. Chapter 17 — SPECIAL INSPECTIONS AND TESTS
  25. Chapter 18 — SOILS AND FOUNDATIONS
  26. Chapter 19 — CONCRETE
  27. Chapter 20 — ALUMINUM
  28. Chapter 21 — MASONRY
  29. Chapter 22 — STEEL
  30. Chapter 23 — WOOD
  31. Chapter 24 — GLASS AND GLAZING
  32. Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
  33. Chapter 26 — PLASTIC
  34. Chapter 27 — ELECTRICAL
  35. Chapter 28 — MECHANICAL SYSTEMS
  36. Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
  37. Chapter 31 — SPECIAL CONSTRUCTION
  38. Chapter 31B — PUBLIC POOLS
  39. Chapter 31C — RADIATION
  40. Chapter 31D — FOOD ESTABLISHMENTS
  41. Chapter 31F — MARINE OIL TERMINALS
  42. Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
  43. Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
  44. Chapter 35 — REFERENCED STANDARDS
  45. Appendix A — EMPLOYEE QUALIFICATIONS
  46. Appendix B — BOARD OF APPEALS
  47. Appendix C — GROUP U – AGRICULTURAL BUILDINGS
  48. Appendix D — FIRE DISTRICTS
  49. Appendix F — RODENTPROOFING
  50. Appendix H — SIGNS
  51. Appendix I — PATIO COVERS
  52. Appendix J — GRADING
  53. Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
  54. Appendix P — EMERGENCY HOUSING

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.