Chapter 35 — REFERENCED STANDARDS
California Building Code (Title 24, Part 2) · 2022 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user.
See Chapter 1 for state agency authority and building applications.)
| Adopting agency | BSC | BSC -CG |
SFM | HCD | DSA | OSHPD | BSCC | DHS | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | BSC | BSC -CG |
SFM | 1 | 2 | 1/AC | AC | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | X | X | |||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | X | X | X | X | X | X | X | X | X | X | ||||||||||||
| Adopt only those sections that are listed below |
X | X | |||||||||||||||||||||
| Chapter/Section | |||||||||||||||||||||||
| AAMA 501.4-18 | X | X | X | X | X | X | X | ||||||||||||||||
| AAMA 501.6-18 | X | X | X | X | X | X | X | ||||||||||||||||
| AAMA TIR A8-16 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 355.2-19 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 355.4-19 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 440.2R-08 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 503.7-07 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 506R-16 | X | X | X | X | X | X | X | ||||||||||||||||
| ACI 506.2-13 | X | X | † | † | † | † | † | ||||||||||||||||
| ACI 506.4R-94 | † | † | X | X | X | X | X | ||||||||||||||||
| ACI 506.6T-17 | † | † | X | X | X | X | X | ||||||||||||||||
| AISC 358-16/s1-18/s2-20 | X | X | |||||||||||||||||||||
| ANSI/DASMA 103-2017 | X | X | |||||||||||||||||||||
| ANSI S3.41 | X | ||||||||||||||||||||||
| ASCE/SEI 7-16 | X | X | X | X | X | X | X | ||||||||||||||||
| ASCE/SEI 19-10 | X | X | X | X | X | ||||||||||||||||||
| ASCE/SEI 41-13 | † | † | X | X | X | X | X | ||||||||||||||||
| ASCE/SEI 41-17 | X | X | † | † | † | † | † | ||||||||||||||||
| ASME A17.1/CSA B44 | X | X | |||||||||||||||||||||
| ASME A18.1-2014 | X | ||||||||||||||||||||||
| ASME BPE-2009 | X | ||||||||||||||||||||||
| ASTM A227/A227M-17 | X | X | |||||||||||||||||||||
| ASTM A229/A229M-17 | X | X | |||||||||||||||||||||
| ASTM A722/A722M-15 | X | X | X | X | X | ||||||||||||||||||
| ASTM A1064-17 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM C618-15 | † | † | X | X | X | X | X | ||||||||||||||||
| ASTM C618-19 | X | X | † | † | † | † | † | ||||||||||||||||
| ASTM C635/C635M-13a | † | † | X | X | X | X | X | ||||||||||||||||
| ASTM C636/C636M-17 | X | X | |||||||||||||||||||||
| ASTM C989-16e1 | † | † | X | X | X | X | X | ||||||||||||||||
| ASTM C989-18a | X | X | † | † | † | † | † | ||||||||||||||||
| ASTM C1019-16 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM C1249-18 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM C1392-20 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM C1394-20 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM C1401-14 | X | X | X | X | X | X | X |
(continued)
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 35 – REFERENCED STANDARDS—continued
| Adopting agency | BSC | BSC -CG |
SFM | HCD | DSA | OSHPD | BSCC | DHS | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | **BSC ** | BSC -CG |
SFM | 1 | 2 | 1/AC | AC | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | X | X | |||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | X | X | X | X | X | X | X | X | X | X | ||||||||||||
| Adopt only those sections that are listed below |
X | X | |||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
| ASTM C1586-05 (2011) | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM D1586-20 |
X | X | X | X | X | X | X | ||||||||||||||||
| ASTM D3966-07 (2013) | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM D5778-20 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM E580/E580M-17 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM E662-17a | X | X | X | ||||||||||||||||||||
| ASTM E2632/E2632M-13 | X | ||||||||||||||||||||||
| ASTM E2707-15 | X | ||||||||||||||||||||||
| ASTM E2726/E2726-12a | X | ||||||||||||||||||||||
| ASTM E3121-17 | † | † | X | X | X | X | X | ||||||||||||||||
| ASTM F606/F606M-16 | X | X | X | X | X | X | X | ||||||||||||||||
| ASTM F1292-99 | X | ||||||||||||||||||||||
| ASTM F1292-04 | X | ||||||||||||||||||||||
| ASTM F1487-01 | X | ||||||||||||||||||||||
| ASTM F1951-99 | X | ||||||||||||||||||||||
| ASTM F2374 | X | ||||||||||||||||||||||
| AWS D1.1/D1.1M-15 | X | X | X | X | X | X | X | ||||||||||||||||
| AWS D1.2/D1.2M-14 | X | X | X | X | X | X | X | ||||||||||||||||
| AWS D1.3/D1.3M-08 | X | X | X | X | X | X | X | ||||||||||||||||
| AWS D1.8/D1.8M-16 | X | X | X | X | X | X | X | ||||||||||||||||
| AWS QCI-16 | X | X | X | X | X | X | X | ||||||||||||||||
| BHMA A156.10-2011 | X | ||||||||||||||||||||||
| BHMA A156.19-2013 | X | ||||||||||||||||||||||
| FEMA P-2082-1 | † | † | X | X | X | X | X | ||||||||||||||||
| FM 1950-16 | X | X | X | X | X | X | X | ||||||||||||||||
| FM 3011-99 | X | ||||||||||||||||||||||
| FM 3260-00 | X | ||||||||||||||||||||||
| FM 4430-80 | X | ||||||||||||||||||||||
| ICC-ES AC01-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC58-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC70-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC77 | X | ||||||||||||||||||||||
| ICC-ES AC106-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC125-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC156-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC178-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC193-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC232-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC308-21* | X | X | X | X | X | X | X |
(continued)
35-2 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 35 – REFERENCED STANDARDS—continued
| Adopting agency | BSC | BSC -CG |
SFM | HCD | DSA | OSHPD | BSCC | DHS | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | BSC | BSC -CG |
SFM | 1 | 2 | 1/AC | AC | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | X | X | |||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | X | X | X | X | X | X | X | X | X | X | ||||||||||||
| Adopt only those sections that are listed below |
X | X | |||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
| ICC ES AC331 | X | ||||||||||||||||||||||
| ICC-ES AC358-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ICC-ES AC446-21* | X | X | X | X | X | X | X | ||||||||||||||||
| ISO 9001-15 | X | X | X | X | X | X | X | ||||||||||||||||
| NFPA 10_-21_ | X | ||||||||||||||||||||||
| NFPA 11-16 | X | ||||||||||||||||||||||
| NFPA 13-22 | X | ||||||||||||||||||||||
| NFPA 13D-22 | X | ||||||||||||||||||||||
| NFPA 13R-22 | X | ||||||||||||||||||||||
| NFPA 14-19 | X | ||||||||||||||||||||||
| NFPA 24-19 | X | X | |||||||||||||||||||||
| NFPA 25-13CA | X | X | |||||||||||||||||||||
| NFPA 32-16 | X | ||||||||||||||||||||||
| NFPA 37-18 | X | ||||||||||||||||||||||
| NFPA 54-18 | X | ||||||||||||||||||||||
| NFPA 72-22 | X | X | X | ||||||||||||||||||||
| NFPA 110-16 | X | ||||||||||||||||||||||
| NFPA 111-13 | X | ||||||||||||||||||||||
| NFPA 130-20 | X | ||||||||||||||||||||||
| NFPA 502-20 | X | ||||||||||||||||||||||
| NFPA 1124-17 | X | ||||||||||||||||||||||
| NFPA 2001-18 | X | ||||||||||||||||||||||
| PCI MNL 120-17 | X | X | X | X | X | X | X | ||||||||||||||||
| PTI DC35.1-14 | X | X | X | X | X | X | X | ||||||||||||||||
| SFM 12-3 | X | ||||||||||||||||||||||
| SFM 12-7-3 | X | ||||||||||||||||||||||
| SFM 12-7A-1 | X | ||||||||||||||||||||||
| SFM 12-7A-2 | X | ||||||||||||||||||||||
| SFM 12-7A-3 | X | ||||||||||||||||||||||
| SFM 12-7A-4 | X | ||||||||||||||||||||||
| SFM 12-7A-4A | X | ||||||||||||||||||||||
| SFM 12-7A-5 | X | ||||||||||||||||||||||
| SFM 12-8-100 | X | ||||||||||||||||||||||
| SFM 12-10-1 | X | ||||||||||||||||||||||
| SFM 12-10-2 | X | ||||||||||||||||||||||
| SFM 12-10-3 | X | ||||||||||||||||||||||
| UBC 15-2 | X | ||||||||||||||||||||||
| UBC 15-3 | X | ||||||||||||||||||||||
| UBC 15-4 | X | ||||||||||||||||||||||
| UL 13-96 | X | ||||||||||||||||||||||
| UL 38-99 | X |
(continued)
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 35 – REFERENCED STANDARDS—continued
| Adopting agency | BSC | BSC -CG |
SFM | HCD | DSA | OSHPD | BSCC | DHS | AGR | DWR | CEC | CA | SL | SLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopting agency | **BSC ** | BSC -CG |
SFM | 1 | 2 | 1/AC | AC | SS | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Adopt entire chapter | X | X | |||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) |
X | X | X | X | X | X | X | X | X | X | X | ||||||||||||
| Adopt only those sections that are listed below |
X | X | |||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
| UL 193-04 | X | ||||||||||||||||||||||
| UL 199-95 | X | ||||||||||||||||||||||
| UL 228-97 | X | ||||||||||||||||||||||
| UL 260-04 | X | ||||||||||||||||||||||
| UL 262-04 | X | ||||||||||||||||||||||
| UL 268A-09 | X | ||||||||||||||||||||||
| UL 312-04 | X | ||||||||||||||||||||||
| UL 346-05 | X | ||||||||||||||||||||||
| UL 464-03 | X | ||||||||||||||||||||||
| UL 497B-04 | X | ||||||||||||||||||||||
| UL 521-99 | X | ||||||||||||||||||||||
| UL 539-00 | X | ||||||||||||||||||||||
| UL 632-00 | X | ||||||||||||||||||||||
| UL 753-04 | X | ||||||||||||||||||||||
| UL 813-96 | X | ||||||||||||||||||||||
| UL 857-13 | † | † | X | X | X | X | X | ||||||||||||||||
| UL 864-2014 | X |
The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
35-4 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CHAPTER 35
REFERENCED STANDARDS
User note:
About this chapter: The California Building Code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials and methods of construction. This chapter contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Chapter 1, Scope and Administration, Division 1, Sections 1.1.5 and 1.1.7, and in Chapter 1, Scope and Administration, Division II, Section 102.4, as applicable.
g_ agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Chapter 1, Scope and Administration, Division 1, Sections 1.1.5 and 1.1.7, and in Chapter 1, Scope and Administration, Division II, Section 102.4, as applicable.
[DSA-SS, DSA-SS/CC & OSHPD 1 & 4] Reference to other chapters. In addition to the code sections referenced, the standards listed in this chapter are applicable to the respective code sections in Chapters 16A, 17A, 18A, 19A, 21A and 22A.
AA Aluminum Association 1400 Crystal Drive, Suite 430 Arlington, VA 22202 ADM—2020: Aluminum Design Manual
1604.3.5, 2002.1
ASM 35—00: Aluminum Sheet Metal Work in Building Construction (Fourth Edition)
2002.1
AAMA American Architectural Manufacturers Association
1900 E Golf Road, Suite 1250 Schaumburg, IL 60173 711—20: Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products 1404.4
714—19: Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings
1404.4
1402—09: Standard Specifications for Aluminum Siding, Soffit and Fascia 1403.5.1
2502—19: Comparative Analysis Procedure for Window and Door Products 1709.5
AAMA/WDMA/CSA 101/I.S.2/A440—17: North American Fenestration Standard/Specifications for Windows, Doors and Skylights
1709.5.1, 2405.5
501.4-18: Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drifts
2410.1 501.6-18: Recommended Dynamic Test Method for Determining the Seismic Drift…¶
501.6-18: Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System
2410.1 TIR A8-16: Structural Performance of Composite Thermal Barrier Framing Systems¶
TIR A8-16: Structural Performance of Composite Thermal Barrier Framing Systems
2411.1¶
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ACI American Concrete Institute
38800 Country Club Drive Farmington Hills, MI 48331-3439 117—10: Specification for Tolerances for Concrete Construction and Materials 1901.7.1
216.1—14: Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 721.1(2), 722.1
318—19: Building Code Requirements for Structural Concrete 722.2.4.3, 1604.3.2, 1616.2.1, 1616.3.1, 1704.5, Table 1705.3, 1705.3.2, Table 1705A.2.1, Table 1705A.3, 1808.8.2, Table 1808.8.2, 1808.8.5, 1808.8.6, 1810.1.3, 1810.2.4.1, 1810.3.2.1.1, 1810.3.2.1.2, 1810.3.8, 1810.3.9.4.2.1, 1810.3.9.4.2.2, 1810.3.10.1, 1810.3.11, 1810.3.11.1, 1810.3.12, 1810.3.13, 1810A.3.10.4, 1901.2, 1901.3, 1901.3.4.4, 1902.1, 1903A, 1903.1, 1904A, 1904.1, 1904.2, 1905A, 1905.1, 1905.1.1, 1905.1.2, 1905.1.3, 1905.1.4, 1905.1.5, 1905.1.6, 1905.1.7, 1905.1.8, 1908.1, 1909.2, 1909.3, 1910A.5.4, 2108.3, 2206.1
355.2—19: Qualification of Post-Installed Mechanical Anchors in Concrete and Commentary 1617A.1.19, 1901.3.2 355.4—19: Qualification of Post-Installed Adhesive Anchors in Concrete and Commentary 1617A.1.19, 1901.3.3 440.2R-08: Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures 1911.3, 1911A.3 503.7—07: Specification for Crack Repair by Epoxy Injection 1911.2, 1911A.2 506R—16: Guide to Shotcrete 1908.1, 1908A.1 506.2—13: [DSA-SS, DSA-SS/CC] Guide to Shotcrete 1908A.1, 1908A.9
506.4R—94: [OSHPD] Guide for the Evaluation of Shotcrete 1908.1, 1908A.1
506.6T—17: [OSHPD] Visual Shotcrete Core Quality Evaluation 1908.1, 1908A.1
550.5—18: Code Requirements for the Design of Precast Concrete Diaphragms for Earthquake Motions Table 1705.3
ITG—7-09: Specification for Tolerances for Precast Concrete
1901.7.2
AISC American Institute of Steel 130 East Randolph Street, Suite 2000 Chicago, IL 60601-6219 ANSI/AISC 341—16: Seismic Provisions for Structural Steel Buildings
1705.13.1.1, 1705.13.1.2, 1705.14.1.1, 1705.14.1.2, 1705A.2.1, 1705A.2.5, 1810.3.5.3.1, 2205A, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2205.3, 2206A, 2206.2.1, 2212.2
ANSI/AISC 358—16/s1—18: Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications,
Including Supplement No. 1
1705 A .2.1, 2205A, 2205.2.1.1, 2205.2.1.2, 2205.4, 2206A.2, 2206.2.1
ANSI/AISC 358—16/s1—18/ s2—20 : [DSA-SS, DSA-SS/CC] Prequalified Connections for Special and Intermediate Steel Moment
Frames for Seismic Applications, Including Supplement No. 1 and No. 2
1705A.2.1, 2205A, 2205.2.1.1, 2205.2.1.2 , 2206A.2, 2212.3
ANSI/AISC 360—16: Specification for Structural Steel Buildings
722.5.2.2.1, 1604.3.3, 1705.2.1, 1705A.2.1, Table 1705A.2.1, 1705A.2.5, 2202.1, 2203.1, 2204.4, 2204A.4, 2205.1, 2205.2.1.1, 2206.1, 2212.1.1, 2212A.1.2. 2212A.2.1
35-6 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
AISI American Iron and Steel Institute 25 Massachusetts Avenue, NW Suite 800 Washington, DC 20001 AISI S100—16(2020) w/S2—20: North American Specification for the Design of Cold-Formed Steel Structural Members, 2016
Edition (Reaffirmed 2020), with Supplement 2, 2020 Edition
1604.3.3, 1905.1.8, 2202.1, 2203.1, 2210.1, 2210.2, 2211A.2
AISI S202—20: Code of Standard Practice for Cold-formed Steel Framing, 2020
2211.1.3.1
AISI S220—20: North American Standard for Cold-Formed Steel Nonstructural Framing
2202.1, 2203.1, 2211.2, Table 2506.2, Table 2507.2
AISI S230—2019: Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, 2019
1609.1.1, 1609.1.1.1, 2211.1.2
AISI S240—20: North American Standard for Cold-Formed Steel Structuring Framing, 2020
2202.1, 2203.1, 2211.1, 2211.1.1.1, 2211.1.3.3, Table 2506.2, Table 2507.2, Table 2603.12.1, Table 2603.12.2
AISI S400—20: North American Standard for Seismic Design of Cold-formed Steel Structural Systems, 2020
2210.2, 2211.1.1.1, 2211.1.1.2
ALI Automotive Lift Institute, Inc.
P.O. Box 85 Cortland, NY 13045 ALI ALCTV—2017: Standard for Automotive Lifts—Safety Requirements for Construction, Testing and Validation (ANSI)
Table 3001.3
AMCA Air Movement and Control Association International
30 West University Drive Arlington Heights, IL 60004 540—13: Test Method for Louvers Impacted by Wind Borne Debris 1609.2.1
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor New York, NY 10036 A13.1—2020: Scheme for the Identification of Piping Systems
415.11.7.5
A108.1A—17: Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar
2103.2.3
A108.1B—17: Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-
Portland Mortar
2103.2.3
A108.4—09: Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive
2103.2.3.6
A108.5—19: Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar
2103.2.3.1, 2103.2.3.2
A108.6—99 (reaffirmed 2019): Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy
2103.2.3.3
A108.8—99 (reaffirmed 2019): Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout
2103.2.3.4
A108.9—19: Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout
2103.2.3.5
A108.10—17: Installation of Grout in Tilework
2103.2.3.7
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ANSI—continued A118.1—18: American National Standard Specifications for Dry-set Portland Cement Mortar
2103.2.3.1
A118.3—13: American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy
and Water Cleanable Tile-setting Epoxy Adhesive
2103.2.3.3
A118.4—18: American National Standard Specifications for Modified Dry-set Cement Mortar
2103.2.3.2, 2103.2.4
A118.5—99: American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation
2103.2.3.4
A118.6—19: American National Standard Specifications for Cement Grouts for Tile Installation
2103.2.3.7
A118.8—99: American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout
2103.2.3.5
A136.1—20: American National Standard Specifications for the Installation of Ceramic Tile
2103.2.3.6
A137.1—19: American National Standard Specifications for Ceramic Tile
202
A137.3—17: American National Standard Specifications for Gauged Porcelain Tiles and Gauged Porcelain Tile Panel/Slabs
202
S3.41: American National Standard Specifications for Audible Emergency Evacuation Signal
907.5.2.1.3
Z 97.1—14: Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test
2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4, 2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1
APA APA - Engineered Wood Association
7011 South 19th Street Tacoma, WA 98466-7400 ANSI 117—2020: Standard Specification for Structural Glued Laminated Timber of Softwood Species
2306.1
ANSI/APA A190.1—2017: Structural Glued Laminated Timber
1705.5.5, 2303.1.3, 2306.1
ANSI/APA PRG 320—2019: Standard for Performance-rated Cross-laminated Timber
602.4, 2303.1.4
ANSI/APA PRP 210—2019: Standard for Performance-Rated Engineered Wood Siding
2303.1.5, 2304.7, 2306.3, Table 2306.3(1)
ANSI/APA PRR 410—16: Standard for Performance-Rated Engineered Wood Rim Boards
2303.1.13
APA PDS Supplement 1—12: Design and Fabrication of Plywood Curved Panels (revised 2013)
2306.1
APA PDS Supplement 2—12: Design and Fabrication of Plywood-lumber Beams (revised 2013)
2306.1
APA PDS Supplement 3—12: Design and Fabrication of Plywood Stressed-skin Panels (revised 2013)
2306.1
APA PDS Supplement 4—12: Design and Fabrication of Plywood Sandwich Panels (revised 2013)
2306.1
APA PDS Supplement 5—16: Design and Fabrication of All-plywood Beams (revised 2013)
2306.1
APA PDS—20: Panel Design Specification
2306.1
APA R540—19: Builder Tips: Proper Storage and Handling of Glulam Beams
2306.1
APA S475—20: Glued Laminated Beam Design Tables
2306.1
35-8 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
APA—continued APA S560—20: Field Notching and Drilling of Glued Laminated Timber Beams
2306.1
APA T300—16: Glulam Connection Details
2306.1
APA X440—17: Product Guide: Glulam
2306.1
APA X450—18: Glulam in Residential Construction—Building—Construction Guide
2306.1
ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road St. Joseph, MI 49085
EP 484.3 DEC2017: Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings
2306.1
EP 486.3 SEP2017: Shallow-post and Pier Foundation Design
2306.1
EP 559.1 AUG2010(R2019): Design Requirements and Bending Properties for Mechanically Laminated Wood Assemblies
2306.1
ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive Reston, VA 20191
7—16 with Supplement s 1, 2 and 3 : Minimum Design Loads and Associated Criteria for Buildings and Other Structures 104.11, 202, Table 1504.2, Table 1504.8, 1510.7.1, 1602.1, 1603A.1.5, 1603A.2, Table 1604.3, 1604.4, 1604A.4, 1604.5, Table 1604.5, 1604.8.2, 1604.9, 1605.1, 1605.1.1, 1605.2, 1606.3, 1607.9.1, 1607.9.1.1, 1607.9.1.2, 1607.10, 1607.14.1, 1607.17, 1608.1, 1608.2, Figure 1608.2(1), 1608.3, 1609.1.1, 1609.2, 1609.3, Figure 1609.3(5), Figure 1609.3(6), Figure 1609.3(7), Figure 1609.3(8), Figure 1609.3(9), Figure 1609.3(10), Figure 1609.3(11), Figure 1609.3(12), 1609.5.1, 1609.5.3, 1611.1, 1611.2, 1612.2, 1613.1, 1613.2.2, 1613.2.3, Table 1613.2.3(1), Table 1613.2.3(2), 1613.2.5, 1613.2.5.1, 1613.2.5.2, 1613.3, 1614.1, 1615.1, 1617, 1617A, 1705.13, 1705.13.1.1, 1705.13.1.2, 1705.13.4, 1705.14.1.1, 1705.14.1.2, 1705.14.2, 1705.14.3, 1705.14.4, 1709.5, 1709.5.3.1, 1802.1, 1803.5.12, 1803A.6, 1806.1, 1807A.2.5, 1811A.4, 1808.3, 1808.3.1, 1809.13, 1810.3.1.1, 1810.3.6.1, 1810.3.8, 1810.3.9.2, 1810.3.9.4, 1810.3.9.4.1, 1810.3.9.4.2, 1810.3.11.2, 1810.3.12, 1811 A .4, 1902.1, 1905.1.2, 1905.1.7, 1905.1.8, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2206.2.1, 2209.1, 2209.2, 2210.2, 2210A.2, 2211.1.1.1, 2212A.1.1, 2212A.2.4, Table 2304.6.1, Table 2306.3(3), Table 2308.7.5, 2404.1, 2410.1.1, 2410.1.2, 2505.1, 2505.2, 2506.2.1, 3115.8.4.2
8—02: Standard Specification for the Design of Cold-formed Stainless Steel Structural Members 1604.3.3, 2210.1, 2210.2
19—16: Structural Applications of Steel Cables for Buildings 2208.1
24—14: Flood Resistant Design and Construction 1202.4.2, 1202.4.4, 1612.2, 1612.4, 2702.1.8, 3001.3
29—17: Standard Calculation Methods for Structural Fire Protection 722.1
32—01: Design and Construction of Frost Protected Shallow Foundations 1809.5
41—13: [OSHPD] Seismic Evaluation and Retrofit of Existing Buildings
1603A.2 41—17: [DSA-SS, DSA-SS/CC] Seismic Evaluation and Retrofit of Existing Buildings¶
41—17: [DSA-SS, DSA-SS/CC] Seismic Evaluation and Retrofit of Existing Buildings
1603A.2 49—12: Wind Tunnel Testing for Buildings and Other Structures¶
49—12: Wind Tunnel Testing for Buildings and Other Structures 1609.1.1
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASCE/SEI—continued 55—16: Tensile Membrane Structures 3102.2
ASHRAE ASHRAE 1791 Tullie Circle NE Atlanta, GA 30329USA 170—2017: Ventilation of Health Care Facilities 1020.6
ASME American Society of Mechanical Engineers
Two Park Avenue New York, NY 10016 A17.1—2019/CSA B44: the edition as referenced in : California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator
Safety Orders Safety Code for Elevators and Escalators
907.3.3, 911.1.6, 1009.4.1, 11B-407.1, 11B-407.1.1, 11B-407.4.9, 11B-408.1, 11B-409.1, 11B-411.1, 11B-810.9, 1607.11.1, 3001.2, Table 3001.3, 3001.4, 3001.5, 3002.5, 3003.2, 3007.1, 3008.1.4, 3008.7.1
A17.7—2007/CSA B44—07(R2017): Performance-based Safety Code for Elevators and Escalators
Table 3001.3, 3001.5, 3002.5
A18.1—2020: Safety Standard for Platform Lifts and Stairway Chairlifts
1110.9, Table 3001.3
A90.1—2015: Safety Standard for Belt Manlifts
Table 3001.3
B16.18—2018: Cast Copper Alloy Solder Joint Pressure Fittings
909.13.1
B16.22—2018: Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
909.13.1
B20.1—2021: Safety Standard for Conveyors and Related Equipment
Table 3001.3, 3004.3
BPE—2009: Bio-processing Equipment Standard B31.3—2014: [SLC] Process Piping
415.11.6
B31.3—2020: Process Piping
415.11.7
ASSP American Society of Safety Professionals
520 N. Northwest Highway Park Ridge, IL 60068 ANSI/ASSE Z359.1—2020: The Fall Protection Code
1015.6, 1015.7
ASTM ASTM International 100 Barr Harbor Drive, P.O. Box C700 West Conshohocken, PA 19428 A6/A6M—2017A: Standard Specification for General Requirements for Rolled Structural Steel Bars, Plates, Shapes and Sheet Piling
1810.3.2.3, 1810.3.5.3.1, 1810.3.5.3.3
A36/A36M—14: Specification for Carbon Structural Steel
1810.3.2.3
A153/A153M—2016A: Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware
2304.10.2.1, 2304.10.6
A227/A227M — 17: Standard Specification for Steel Wire, Cold-Drawn for Mechanical Springs
1211.1.1
35-10 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
A229/A229M — 17: Standard Specification for Steel Wire, Quenched and Tempered for Mechanical Springs
1211.1.1
A240/A240M—17: Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure
Vessels and for General Applications
Table 1507.4.3(1)
A252—2010(2018): Specification for Welded and Seamless Steel Pipe Piles
1810.3.2.3
A283/A283M—2018: Specification for Low and Intermediate Tensile Strength Carbon Steel Plates
1810.3.2.3
A416/A416M—2017A: Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete
1810.3.2.2
A463/A463M—15: Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process
Table 1507.4.3(2)
A572/A572M—2018: Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel
1810.3.2.3
A588/A588M—15: Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with
Atmospheric Corrosion Resistance
1810.3.2.3
A615/A615M—15ae1: Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement
1704.5, 1810.3.10.2
A653/A653M—2017: Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip
Process
Table 1507.4.3(1), Table 1507.4.3(2), 2304.10.6.1
A690/A690M—13a(2018): Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet
Piling with Atmospheric Corrosion Resistance for Use in Marine Environments
1810.3.2.3
A706/A706M—2016: Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement
1704.5, Table 1705.3, 2107.3, 2108.3
A722/A722M—20 15: [OSHPD] : Specification for High-strength Steel Bars for Prestressed Concrete
1810.3.10.2, 1811.4, 1811A.4, 1812.4.2, 1812A.4.2
A722/A722M—2018: Specification for High-strength Steel Bars for Prestressed Concrete
1810.3.10.2
A755/A755M—2016E1: Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating
Process for Exterior Exposed Building Products
Table 1507.4.3(1), Table 1507.4.3(2)
A792/A792M—10(2015): Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process
Table 1507.4.3(1), Table 1507.4.3(2)
A875/A875M—13: Standard Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process
Table 1507.4.3(2)
A924/A924M—2017A: Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process
Table 1507.4.3(1)
A1064—17: Standard Specification for Carbon-steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
1903.8, 1903A.8
B42—2015A: Specification for Seamless Copper Pipe, Standard Sizes
909.13.1
B43—15: Specification for Seamless Red Brass Pipe, Standard Sizes
909.13.1
B68/B68M—11: Specification for Seamless Copper Tube, Bright Annealed (Metric)
909.13.1
B88—2016: Specification for Seamless Copper Water Tube
909.13.1
B101—12: Specification for Lead-coated Copper Sheet and Strip for Building Construction
1403.5.3, Table 1507.2.8.2, Table 1507.4.3(1)
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
B209—14: Specification for Aluminum and Aluminum Alloy Steel and Plate
Table 1507.4.3(1)
B251—2017: Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
909.13.1
B280—2018: Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
909.13.1
B370—12: Specification for Copper Sheet and Strip for Building Construction
1403.5.2, Table 1507.2.8.2, Table 1507.4.3(1)
B695—2004(2016): Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building
Construction
2304.10.2.1, 2304.10.6.1, 2304.10.6.3
C5—2018: Specification for Quicklime for Structural Purposes
2109.2.4.8.7, Table 2507.2
C22/C22M—2015: Specification for Gypsum
Table 2506.2
C27—1998(2018): Specification for Classification of Fireclay and High-alumina Refractory Brick
2111.6
C28/C28M—10(2015): Specification for Gypsum Plasters
Table 2507.2
C31/C31M—2018B: Practice for Making and Curing Concrete Test Specimens in the Field
Table 1705.3
C33/C33M—2018: Specification for Concrete Aggregates
722.3.1.4, 722.4.1.1.3
C35/C35—01(2014): Specification for Inorganic Aggregates for Use in Gypsum Plaster
Table 2507.2
C55—2017: Specification for Concrete Building Brick
Table 722.3.2
C59/C59M—00(2015): Specification for Gypsum Casting Plaster and Molding Plaster
Table 2507.2
C61/C61M—00(2015): Specification for Gypsum Keene’s Cement
Table 2507.2
C62—2017: Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)
1807.1.6.3
C67/C67M—2018: Test Methods of Sampling and Testing Brick and Structural Clay Tile
722.4.1.1.1, 2109.2.1.1
C73—2017: Specification for Calcium Silicate Brick (Sand-lime Brick)
Table 722.3.2
C90—2016A: Specification for Loadbearing Concrete Masonry Units
Table 722.3.2, 1807.1.6.3, 2114.3
C91/C91M—2018: Specification for Masonry Cement
Table 2507.2
C94/C94M—2017: Specification for Ready-mixed Concrete
110.3.1, 1705A.3.3.1
C140/C140M—2018: Test Method Sampling and Testing Concrete Masonry Units and Related Units
722.3.1.2
C141/C141M —14: Standard Specification for Hydrated Hydraulic Lime for Structural Purposes
2109.2.4.8.7
C150/C150M—2018: Specification for Portland Cement
1909.2.3, 1910A.1, 1910.2.1, Table 2507.2
C172/C172M—2017: Practice for Sampling Freshly Mixed Concrete
Table 1705.3
35-12 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
C199—1984(2016): Test Method for Pier Test for Refractory Mortars
2111.6, 2111.9, 2113.12
C206—14: Specification for Finishing Hydrated Lime
2109.2.4.8.7, Table 2507.2
C208—2012(2017)E1: Specification for Cellulosic Fiber Insulating Board
Table 1508.2, 2303.1.6
C216—2017A: Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)
Table 721.1(2), 1807.1.6.3
C270—14a: Specification for Mortar for Unit Masonry
2105.3, 2105A.3
C315—2007(2016): Specification for Clay Flue Liners and Chimney Pots
2111.9, 2113.11.1, Table 2113.16(1)
C317/C317M—2000(2015): Specification for Gypsum Concrete
2514.1
C330/C330M—2017A: Specification for Lightweight Aggregates for Structural Concrete
202
C331/C331M—2017: Specification for Lightweight Aggregates for Concrete Masonry Units
722.3.1.4, 722.4.1.1.3
C406/C406M—15: Specification for Roofing Slate
1507.7.5
C472—99(2014): Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete
Table 2506.2
C473—2017: Test Methods for Physical Testing of Gypsum Panel Products
Table 2506.2
C474—15: Test Methods for Joint Treatment Materials for Gypsum Board Construction
Table 2506.2
C475/C475M—2017: Specification for Joint Compound and Joint Tape for Finishing Gypsum Board
Table 2506.2
C514—04(2014): Specification for Nails for the Application of Gypsum Board
Table 721.1(2), Table 721.1(3), Table 2506.2
C516—2008(2014)E1: Specifications for Vermiculite Loose Fill Thermal Insulation
722.3.1.4, 722.4.1.1.3
C547—2017: Specification for Mineral Fiber Pipe Insulation
Table 721.1(2), Table 721.1(3)
C549—06(2012): Specification for Perlite Loose Fill Insulation
722.3.1.4, 722.4.1.1.3
C552—2017E1: Standard Specification for Cellular Glass Thermal Insulation
Table 1508.2
C557—2003(2017): Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing
Table 2506.2, 2508.4
C578—2018: Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
Table 1508.2, 2603.10, Table 2603.12.1, Table 2603.12.2, Table 2603.13.1, Table 2603.13.2
C587—2004(2018): Specification for Gypsum Veneer Plaster
Table 2507.2
C595/C595M—2018: Specification for Blended Hydraulic Cements
1909.2.3, 1910A.1
C618—15: [OSHPD] Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
1910A.1 C618—19: [DSA-SS, DSA-SS/CC] Standard Specification for Coal Fly Ash and Raw or…¶
C618—19: [DSA-SS, DSA-SS/CC] Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
1909.2.3, 1910A.1
C631—09(2014): Specification for Bonding Compounds for Interior Gypsum Plastering
Table 2507.2
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
C635/C635M— 13a : [OSHPD] Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
1617A.1.21 C635/C635M—2017: Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
2506.2.1, 1617A.1.21
C636/C636M—13: Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels
808.1.1.1, 1617A.1.21
C636/C636M— 17 : [DSA-SS, DSA-SS/CC] Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels
808.1.1.1, 1617.10.16, 1617A.1.21
C652—2017A: Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)
1807.1.6.3
C726—2017: Standard Specification for Mineral Wool Roof Insulation Board
Table 1508.2
C728—2017A: Standard Specification for Perlite Thermal Insulation Board
Table 1508.2
C744—2016: Specification for Prefaced Concrete and Calcium Silicate Masonry Units
Table 722.3.2
C754—2018: Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products
Table 2508.1, Table 2511.1.1
C836/C836M—2018: Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with
Separate Wearing Course
1507.14.2
C840—2018A: Specification for Application and Finishing of Gypsum Board
Table 2508.1, 2509.2
C841—2003(2018): Specification for Installation of Interior Lathing and Furring
Table 2508.1, Table 2511.1.1
C842—05(2015): Specification for Application of Interior Gypsum Plaster
Table 2511.1.1, 2511.3, 2511.4
C843—2017: Specification for Application of Gypsum Veneer Plaster
Table 2511.1.1
C844—2015: Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster
Table 2508.1
C847—14a: Specification for Metal Lath
Table 2507.2
C887—13: Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar
1805.2.2, 2103.2.2
C897—15: Specification for Aggregate for Job-mixed Portland Cement-based Plaster
Table 2507.2
C920—2018: Standard for Specification for Elastomeric Joint Sealants
703.7, Table 2506.2
C926—2018B: Specification for Application of Portland Cement-based Plaster
2109.2.4.8.6, 2109.2.4.8.8, 2510.3, Table 2511.1.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7
C932—06(2013): Specification for Surface-applied Bonding Compounds for Exterior Plastering
Table 2507.2
C933—2018: Specification for Welded Wire Lath
Table 2507.2
C946—2018: Specification for Construction of Dry-stacked, Surface-bonded Walls
2103.2.2, 2114.5
35-14 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
C954—2018: Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs
from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness
Table 2506.2, Table 2507.2
C956—04(2015): Specification for Installation of Cast-in-place Reinforced Gypsum Concrete
2514.1
C957/C957M—2017: Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral
Wearing Surface
1507.14.2
C989—16e1: [OSHPD] Standard Specification for Slag Cement for Use in Concrete and Mortars
1910.2.1, 1910A.1 C989—18a: [DSA-SS, DSA-SS/CC] Standard Specification for Slag Cement for Use in Concrete and Mortars
1909.2.3, 1910A.1 C1002—2018: Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster
Bases to Wood Studs or Steel Studs
722.7.2.2, Table 2506.2, Table 2507.2
C1007—11a(2015): Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories
Table 2508.1, Table 2511.1.1
C1019—16: Test Method for Sampling and Testing Grout
2105A.3, 2105.3, 2115.8.1 C1029—15: Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation
1507.13.2
C1032—2018: Specification for Woven Wire Plaster Base
Table 2507.2
C1047—2014a: Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
Table 2506.2, Table 2507.2
C1063—2018B: Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster
2109.2.4.8.5, 2510.3, Table 2511.1.1, 2512.1.1
C1088—2018: Specification for Thin Veneer Brick Units Made from Clay or Shale
Table 721.1(2)
C1157/C1157M—2017: Standard Performance Specification for Hydraulic Cement
1909.2.3, 1910.2.1, 1910A.1, Table 2507.2
C1167—2011(2017): Specification for Clay Roof Tiles
1507.3.4
C1177/C1177M—2017: Specification for Glass Mat Gypsum Substrate for Use as Sheathing
Table 1508.2, Table 2506.2
C1178/C1178M—2018: Specification for Coated Mat Water-resistant Gypsum Backing Panel
Table 2506.2, Table 2509.2
C1186—2008(2016): Specification for Flat Fiber Cement Sheets
1403.10, 1404.16.1, 1404.16.2
C1249—18: Standard Guide for Secondary Seal for Sealed Insulated Glass Units for Structural Sealant Glazing Applications
2410.1.1 C1261—2013(2017)E1: Specification for Firebox Brick for Residential Fireplaces
2111.6, 2111.9
C1278/C1278M—2017: Specification for Fiber-reinforced Gypsum Panel
Table 1508.2, Table 2506.2
C1280—13a: Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing
Table 2508.1, 2508.2
C1283—2015: Practice for Installing Clay Flue Lining
2113.9.1, 2113.12
C1288—2017: Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets
Table 2509.2
C1289—2018: Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
Table 1508.2, 2603.10, Table 2603.12.1, Table 2603.12.2
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
C1313/C1313M—13: Standard Specification for Sheet Radiant Barriers for Building Construction Applications
1510.4
C1325—2018: Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units
Table 2509.2
C1328/C1328M—12: Specification for Plastic (Stucco Cement)
Table 2507.2
C1364—2017: Standard Specification for Architectural Cast Stone
2103.1
C1372—17: Standard Specification for Dry-Cast Segmental Retaining Wall Units
1807.2.4
C1392—20: Standard Guide for Evaluating Failure of Structural Sealant Glazing
2410.1.2, 2410.1.3 C1394—20: Standard Guide for In-Situ Structural Silicone Glazing Evaluation
2410.1.3
C1396/C1396M—2017: Specification for Gypsum Board
Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2
C1401—14: Standard Guide for Structural Sealant Glazing
2410.1 C1492—2003(2016): Standard Specification for Concrete Roof Tile¶
C1492—2003(2016): Standard Specification for Concrete Roof Tile
1507.3.5
C1568—08(2013): Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Mechanical Uplift Resistance Method)
1504.3.1.1
C1569—03(2016): Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Wind Tunnel Method)
1504.3.1.2
C1570—03(2016): Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Air Permeability Method)
1504.3.1.3
C1586—05(2011): Standard Guide for Quality Assurance of Mortars
2105.3 C1600/C1600M—2017: Standard Specification for Rapid Hardening Hydraulic Cement¶
C1600/C1600M—2017: Standard Specification for Rapid Hardening Hydraulic Cement
Table 2507.2
C1629/C1629M—2018A: Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-
reinforced Cement Panels
403.2.2.1, 403.2.2.2, 403.2.2.4
C1658/C1658M—2018: Standard Specification for Glass Mat Gypsum Panels
Table 2506.2
C1670/C1670M—2018: Standard Specification for Adhered Manufactured Stone Masonry Veneer Units
2103.1
C1707—18: Standard Specification for Pozzolanic Hydraulic Lime for Structural Purposes
2109.2.4.8.7
C1766—2015: Standard Specification for Factory-laminated Gypsum Panel Products
Table 2506.2
C1788—14: Standard Specification for Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall
Applications
2109.2.4.8.5
D25—2012(2017): Specification for Round Timber Piles
1810.3.2.4, 2303.1.12
D41/D41M—2011(2016): Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D43/D43M—2000(2018): Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D56—2016A: Test Method for Flash Point by Tag Closed Cup Tester
202
35-16 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
D86—2017: Test Method for Distillation of Petroleum Products and Liquid Fuels at Atmospheric Pressure
202
D92—2018: Test Method for Flash and Fire Points by Cleveland Open Cup Tester
202
D93—2018: Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
202
D226/D226M—2017: Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing
1403.2, 1505.2, 1507.1.1, Table 1507.1.1(1), 1507.3.3, Table 1507.8, 1507.9.5, Table 1507.10.2, 1507.17.3, 1507.17.4.1
D227/D227M—2003(2018): Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing
Table 1507.10.2
D312/D312M—2016M: Specification for Asphalt Used in Roofing
Table 1507.10.2
D422—63(2007)e2: Test Method for Particle-size Analysis of Soils
1803.5.3
D448—2012(2017): Standard Classification for Sizes of Aggregate for Road and Bridge Construction
1507.12.3
D450/D450M—2017(2018): Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D635—14: Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
2606.4
D1143/D1143M—2007(2013)E1: Test Methods for Deep Foundations Under Static Axial Compressive Load
1810.3.3.1.2
D1227—13: Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
Table 1507.10.2
D1557—12e1: Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft 3 (2,700 kN m/m 3 )]
1705.6, 1804.6
D1586—20: Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils
1813, 1813A.2
D1863/D1863M—2005(2018): Specification for Mineral Aggregate Used on Built-up Roofs
Table 1504.9, Table 1507.10.2
D1929—16: Standard Test Method for Determining Ignition Temperature of Plastics
402.6.4.4, 406.7.2, 2606.4
D1970/D1970M—2017A: Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof
Underlayment for Ice Dam Protection
1507.1.1, 1507.3.9, 1507.5.7, 1507.8.8, 1507.9.9, 1507.11.2.1, 1507.17.4.1
D2178/D2178M—15A: Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
Table 1507.10.2
D2487—2017: Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
Table 1610.1, 1803.5.1
D2626/D2626M—04(2012)e1: Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing
Table 1507.1.1(1), 1507.3.3, Table 1507.10.2
D2822/D2822M—2005(2011): Specification for Asphalt Roof Cement, Asbestos Containing
Table 1507.10.2
D2823/D2823M—05(2011)e1: Specification for Asphalt Roof Coatings, Asbestos Containing
Table 1507.10.2
D2824/D2824M—2018: Standard Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered and Fibered without Asbestos
Table 1507.10.2
D2843—16: Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics
2606.4
D2859—2016: Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials
804.4.1, 804.4.2
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
D2898—2010(2017): Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing
1505.1, 2303.2.4, 2303.2.6
D3019/D3019M—2017: Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos
Fibered
Table 1507.10.2
D3161/D3161M—2016A: Test Method for Wind Resistance of Steep Slope Roofing Products (Fan Induced Method)
1504.2, Table 1504.2, 1504.4.3
D3200—1974(2017): Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber
Construction Poles
2303.1.12
D3201/D3201M—13: Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products
2303.2.7
D3278—96(2011): Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus
202
D3462/D3462M—2016: Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules
1507.2.4
D3468/D3468M—99(2013)e1: Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and
Waterproofing
1507.14.2
D3498—03(2011): Standard Specification for Adhesives for Field-Gluing Plywood to Lumber Framing for Floor Systems
703.7
D3679—2017: Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding
1403.9, 1404.14
D3689/D3698M—07(2013)e1: Test Methods for Deep Foundations under Static Axial Tensile Load
1810.3.3.1.5
D3737—2018E1: Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)
2303.1.3
D3746/D3746M—1985(2015)E1: Test Method for Impact Resistance of Bituminous Roofing Systems
1504.8
D3747—79(2007): Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation
Table 1507.10.2
D3909/D3909M—14: Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules
1507.2.8.2, 1507.6.5, Table 1507.10.2
D3957—2009(2015): Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings
2303.1.11
D3966—07(2013): Standard Test Method for Deep Foundations Under Lateral Loads
1810A.3.3.2
D4022/D4022M—07(2012)e1: Specification for Coal Tar Roof Cement, Asbestos Containing
Table 1507.10.2
D4272—15: Test Method for Total Energy Impact of Plastic Films by Dart Drop
1504.8
D4318—2017E1: Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils
1803.5.3
D4434/D4434M—2015: Specification for Poly (Vinyl Chloride) Sheet Roofing
Table 1507.12.2
D4479/D4479M—2007(2018): Specification for Asphalt Roof Coatings—Asbestos-free
Table 1507.10.2
D4586/D4586M—2007(2018): Specification for Asphalt Roof Cement—Asbestos-free
Table 1507.10.2
D4601/D4601M—04(2012)e1: Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
Table 1507.10.2, 1507.11.2.1
35-18 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
D4637/D4637M—2015: Specification for EPDM Sheet Used in Single-ply Roof Membrane
Table 1507.12.2
D4829—11: Test Method for Expansion Index of Soils
1803.5.3
D4869/D4869M—2016A: Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing
1507.1.1, Table 1507.1.1(1), 1507.17.3, 1507.17.4.1
D4897/D4897M—2016: Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing
Table 1507.10.2
D4945—2017: Test Method for High-strain Dynamic Testing of Deep Foundations
1705.10, 1810.3.3.1.2
D4990—97a(2013): Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
Table 1507.10.2
D5019—07a: Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane
Table 1507.12.2
D5055—2016: Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists
2303.1.2
D5456—2018: Specification for Evaluation of Structural Composite Lumber Products
2303.1.10
D5516—2018: Test Method of Evaluating the Flexural Properties of Fire-retardant Treated Softwood Plywood Exposed to Elevated
Temperatures
2303.2.5.1
D5643/D5643M—2006(2018): Specification for Coal Tar Roof Cement, Asbestos-free
Table 1507.10.2
D5664—2017: Standard Test Method for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength
Properties of Fire-retardant Treated Lumber
2303.2.5.2
D5665/D5665M—99a(2014)e1: Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing
Table 1507.10.2
D5726—98(2013): Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing
Table 1507.10.2
D5778—20: Standard Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils
1813, 1813A.2 D5882—16: Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations
1705.10
D6083/D6083M—2018: Specification for Liquid Applied Acrylic Coating Used in Roofing
Table 1507.10.2, Table 1507.13.3
D6162/D6162M—2016: Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination
of Polyester and Glass Fiber Reinforcements
1507.11.2
D6163/D6163M—2016: Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber
Reinforcements
1507.11.2
D6164/D6164M—2016: Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using
Polyester Reinforcements
1507.11.2
D6222/D6222M—2016: Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester
Reinforcements
1507.11.2
D6223/D6223M—2016: Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of
Polyester and Glass Fiber Reinforcements
1507.11.2
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
D6298—2016: Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory
Applied Metal Surface
1507.11.2
D6305—08(2015)e1: Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof
Sheathing
2303.2.5.1
D6380/D6380M—2003(2018): Standard Specification for Asphalt Roll Roofing (Organic) Felt
Table 1507.1.1(1), 1507.2.8.2, 1507.3.3, 1507.6.5
D6464—2003A(2017): Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing
Table 2506.2, 2508.4
D6509/D6509M—2016: Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet Materials Using
Glass Fiber Reinforcements
1507.11.2
D6694/D6694M—08(2013)e1: Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing
Systems
Table 1507.13.3
D6754/D6754M—2015: Standard Specification for Ketone Ethylene Ester Based Sheet Roofing
Table 1507.12.2
D6757—2018: Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep Slope Roofing
1507.1.1, Table 1507.1.1(1), 1507.17.3, 1507.17.4.1
D6760—16: Standard Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing
1705.10
D6841—2016: Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant Treated Lumber
2303.2.5.2
D6878/D6878M—2017: Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing
Table 1507.12.2
D6947/D6947M—2016: Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane
Foam Roofing System
Table 1507.13.3
D7032—2017: Standard Specification for Establishing Performance Ratings for Wood, Plastic Composite Deck Boards and Guardrail
Systems (Guards or Rails)
705.2.3.1, 2612.2, 2612.4, 2612.5.1
D7147—2011(2018): Specification for Testing and Establishing Allowable Loads of Joist Hangers
2303.5, 2304.10.4
D7158/D7158M—2019: Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
1504.2, Table 1504.2
D7254—2017: Standard Specification for Polypropylene (PP) Siding
1403.12
D7425/D7425M—13: Standard Specification for Spray Polyurethane Foam Used for Roofing Applications
1507.13.2
D7655/D7655M—2012(2017): Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane Systems
1507.12.3
D7672—14E1: Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies
2303.1.13
D7949—14: Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations
1705.10
E84—2018B: Standard Test Methods for Surface Burning Characteristics of Building Materials
202, 402.6.4.4, 406.7.2, 424.2, 602.4.1.1, 602.4.2.1, 602.4.3.1, 720.1, 720.4, 803.1.2, 803.5.2, 803.10, 803.11, 803.12, 803.13, 806.7, 1402.5, 1403.12.1, 1406.9, 1406.10.1, 1408.9, 1408.10.1, 1511.6.2, 1511.6.3, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2603.5.5, 2603.7, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.3
35-20 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
E90—2009(2016): Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
1206.2, 1206.2.1
E96/E96M—2016: Standard Test Methods for Water Vapor Transmission of Materials
202, 1202.3, 1404.3.1
E108—2017: Standard Test Methods for Fire Tests of Roof Coverings
1505.1, 2603.6, 2610.2, 2610.3
E119—2018B: Standard Test Methods for Fire Tests of Building Construction and Materials
703.2.1.1, 703.2.1.3, 703.2.1.4, 703.2.1.5, 703.2.2, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.6, 712.1.13.2, 714.4.1, 714.5.1, 715.3, 715.4, 715.4.1, Table 716.1(1), Table 716.1(2), Table 716.1(3), 716.1.2.3, 716.2.5.1.1, 716.2.5.4, 716.3.2.1.1, 717.3.1, 717.5.2, 717.5.3, 717.6.1, 717.6.2, Table 721.1(1), 2103.1, 2603.5.1
E136—2019: Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
703.3.1
E283—04(2012): Standard Test Method for Determining Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors
Under Specified Pressure Differences across the Specimen
202
E330/E330M—14: Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by
Uniform Static Air Pressure Difference
1709.5.2, 1709.5.2.1, 1709.5.3.1
E331—2000(2016): Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by
Uniform Static Air Pressure Difference
1402.2, 1403.2
E336—19a: Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
1206.2
E492—2009(2016)E1: Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies
Using the Tapping Machine
1206.3
E580/E580M—17: Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions
1617.11.16, 1617A.1.21
E605/E605M—93(2015)e1: Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural
Members
1705.15
E648—2017A: Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source
406.2.4, 424.2, 804.2, 804.3, 804.4.1, 804.4.2
E662—17a: Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials
804.4.1, 804.4.2
E681—09(2015): Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases
202
E736/E736M—2017: Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members
704.13.3.2, 1705.15.6
E814—2013A(2017): Test Method for Fire Tests of Penetration Firestop Systems
202, 714.4.1.2, 714.4.2, 714.5.1.2
E970—2017: Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
720.3.1
E1007—16: Test Method f or Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies
and Associated Support Structures
1206.3
E1300—2016: Practice for Determining Load Resistance of Glass in Buildings
2404.1, 2404.2, 2404.3.1, 2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
E1354—2017: Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen
Consumption Calorimeter
424.2, 602.4.1.1, 602.4.2.1, 602.4.3.1, 1402.5
E1592—2005(2017): Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure
Difference
1504.4.2
E1602—2003(2017): Guide for Construction of Solid Fuel-burning Masonry Heaters
2112.2
E1886—2013A: Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems
Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
1609.2, 1709.5.3.1
E1966—2015: Standard Test Method for Fire-resistive Joint Systems
202, 715.3.1, 1709.5.3.1
E1996—2017: Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by
Windborne Debris in Hurricanes
1609.2, 1609.2.2, 1709.5.3.1
E2072—14: Standard Specification for Photoluminescent (Phosphorescent) Safety Markings
1025.4
E2174—2018: Standard Practice for On-site Inspection of Installed Fire Stops
1705.18.1
E2178—13: Standard Test Method for Air Permeance of Building Materials
202
E2273—2018: Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad
Wall Assemblies
1407.4.1, 2510.6.2
E2307—15BE1: Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using the Intermediate-scale,
Multistory Test Apparatus
715.4
E2353—2016: Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards and Balustrades
2407.1.2
E2392 / E2392M—10(2016): Standard Guide for Design of Earthen Wall Building Systems
2109.2.4.8.9.2
E2393—10a(2015): Standard Practice for On-site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers
1705.18.2
E2404—2017: Practice for Specimen Preparation and Mounting of Textile, Paper or Polymeric (Including Vinyl) and Wood Wall or
Ceiling Coverings, Facing and Veneers to Assess Surface Burning Characteristics
803.5.2, 803.12, 1402.5
E2556/E2556M—2010(2016): Standard Specification for Vapor Permeable Flexible Sheet Water-resistive Barriers Intended for
Mechanical Attachment
1403.2, 2510.6.1
E2568—2017A: Standard Specification for PB Exterior Insulation and Finish Systems
1407.2
E2570/E2570M—07(2014)e1: Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used under Exterior
Insulation and Finish Systems (EIFS) for EIFS with Drainage
1407.4.1.1, 1705.17.1
E2573—2017: Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface
Burning Characteristics
803.10
E2579—2015: Standard Practice for Specimen Preparation and Mounting of Wood Products to Assess Surface Burning
Characteristics
803.11
35-22 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ASTM—continued
E2599—2018: Standard Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier and Vinyl Stretch
Ceiling Materials for Building Applications to Assess Surface Burning Characteristics
2614.3
E2632/E2632M—13: Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials
709A.3, 709A.4, 709A.4.1, 709A.5
E2634—2018: Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems
1903.4
E2652—16: Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-shaped Airflow Stabilizer at 750 o C
703.3.1
E2707—15: Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure
707A.3, 707A.3.1, 708A.3
E2726/E2726—12a: Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands
709A.3, 709A.4, 709A.4.2
E2751/E2751M—2017A: Practice for Design and Performance of Supported Laminated Glass Walkways
2409.1
E2925—17: Standard Specification for Manufactured Polymeric Drainage and Ventilation Materials Used to Provide a Rainscreen
Function
2510.6.2
E3121 — 17: [OSHPD] Standard Test Methods for Field Testing of Anchors in Concrete or Masonry
1901.3.4.2, 1910A.5.2
F547—2017: Terminology of Nails for Use with Wood and Wood-base Materials
Table 2506.2
F606/F606M—16: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets
2213.1, 2213A.1
F1292—99: Standard Specification for Impact Attenuation of Surface Systems Under and Around Playground Equipment
11B-1008.2.6.2
F1292—04: Standard Specification for Impact Attenuation of Surface Systems Under and Around Playground Equipment
11B-1008.2.6.2
F1487—01: Standard Consumer Safety Performance Specification for Playground Equipment for Public Use
202-USE ZONE
F1667—2018: Specification for Driven Fasteners: Nails, Spikes and Staples
Table 721.1(2), Table 721.1(3), 1507.2.5, 1507.16.5, 2303.6, Table 2304.10.2, 2304.10.6, Table 2506.2, Table 2603.13.1, Table 2603.13.2
F1951—99: Standard Specification for Determination of Accessibility of Surface Systems Under and Around Playground Equipment
11B-1008.2.6.1
F2006—17: Standard/Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue
(Ingress) Windows
1015.8
F2090—17: Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
1015.8, 1015.8.1
F2200—2017: Standard Specification for Automated Vehicular Gate Construction
3110.2
F2374—2021: Standard Practice for Design, Manufacture, Opertion, and Maintenance of Inflatable Amusement Devices
3102
G152—13: Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials
1504.7
G154—2016A: Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials
1504.7
G155—13: Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials
1504.7
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
AWC American Wood Council 222 Catoctin Circle SE, Suite 201 Leesburg, VA 20175
ANSI/AWC NDS—2018: National Design Specification (NDS) for Wood Construction—with 2018 NDS Supplement
202, 722.1, Table 1604.3, 1809.12, 1810.3.2.4, Table 1810.3.2.6, 1905.1.8, 2304.13, 2306.1, Table 2306.2(1), Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1, Table 2603.13.2
ANSI/AWC PWF—2021: Permanent Wood Foundation Design Specification
1805.2, 1807.1.4, 2304.10.6.2
ANSI/AWC SDPWS—2021: Special Design Provisions for Wind and Seismic
202, 2305.1, 2305.2, 2305.3, 2306.1, 2306.2, 2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1
ANSI/AWC WFCM—2018: Wood Frame Construction Manual for One- and Two-Family Dwellings
1609.1.1, 1609.1.1.1, 2302.1, 2308.2.4, 2308.6.7.2, 2309.1
AWC STJR—2021: Span Tables for Joists and Rafters
2306.1.1, 2308.4.2.1, 2308.7.1, 2308.7.2
AWC WCD No. 4—2003: Wood Construction Data—Plank and Beam Framing for Residential Buildings
2306.1.2
AWCI Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210 Falls Church, VA 22046
12-B—14: Technical Manual 12B, Third Edition; Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide
1705.16
AWPA American Wood Protection Association
P.O. Box 361784 Birmingham, AL 35236-1784
C1—03: All Timber Products—Preservative Treatment by Pressure Processes
1505.6
M4—15: Standard for the Care of Preservative-treated Wood Products
1810.3.2.4.1, 2303.1.9
U1—20: USE CATEGORY SYSTEM: User Specification for Treated Wood Except Commodity Specification H
Table 1507.9.6, 1807.1.4, 1807.3.1, 1809.12, 1810.3.2.4.1, 1812.2, 1812A.2, 2303.1.9, 2304.12.1, 2304.12.2, 2304.12.2.6, 2304.12.2.7, 2304.12.2.8
AWS American Welding Society
8669 NW 36 Street, #130 Miami, FL 33166-6672
D1.1/D1.1M—15: Structural Welding Code—Steel
Table 1705A.2.1, 1705A.2.5, 2204.1.1, 2204A.1.1, 2212.6.2, 2213.2, 2213A.2
D1.2/D1.2M—14: Structural Welding Code—Aluminum
2003.1 D1.3/D1.3M—08: Structural Welding Code—Sheet Steel¶
D1.3/D1.3M—08: Structural Welding Code—Sheet Steel
Table 1705A.2.1, 1705A.2.5
D1.4/D1.4M—2018: Structural Welding Code—Steel Reinforcing Bars
1704.5, 1704A.5, Table 1705A.2.1, 1705A.2.5, Table 1705.3, 1705.3.1, 1705A.3.1, 1903.8, 1903A.8, 2107.3
D1.8/D1.8M—2016: Structural Welding Code—Seismic Supplement
Table 1705A.2.1, 1705.2.5, 1705A.2.5
QC1—2016: Specification for AWS Certification of Welding Inspectors
1705.2.5, 1705A.2.5
35-24 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
BHMA Builders Hardware Manufacturers’ Association
355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10—2017: Power Operated Pedestrian Doors
1010.3.2, 11B-404.2.9, 11B-404.3
A 156.19—2019: Standard for Power Assist and Low Energy Power Operated Doors
1010.3.2, 11B-404.2.9, 11B-404.3, 11B-408.3.2.1, 11B-409.3.1
A 156.27—2019: Power and Manual Operated Revolving Pedestrian Doors
1010.3.1.1
A 156.38—2019: Low Energy Power Operated Sliding and Folding Doors
1010.3.2
CEN European Committee for Standardization (CEN)
Rue de la Science 23 Brussels, Belgium 1000 BS EN 15250—2007: Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods
2112.2, 2112.5
EN 1081—98: Resilient Floor Coverings—Determination of the Electrical Resistance
406.7.1
CPA Composite Panel Association 19465 Deerfield Avenue, Suite 306 Leesburg, VA 20176 ANSI A135.4—2012: Basic Hardboard
1403.3.1, 2303.1.7
ANSI A135.5—2012: Prefinished Hardboard Paneling
2303.1.7, 2304.7
ANSI A135.6—2012: Engineered Wood Siding
1403.3.2, 2303.1.7
ANSI A208.1—2016: Particleboard
2303.1.8, 2303.1.8.1
CPSC Consumer Product Safety Commission
4330 East/West Highway Bethesda, MD 20814 16 CFR Part 1201 (2002): Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4, 2408.2.1, 2408.3, 2409.2, 2409.4.1
16 CFR Part 1209 (2002): Interim Safety Standard for Cellulose Insulation 720.6
16 CFR Part 1404 (2002): Cellulose Insulation 720.6
16 CFR Part 1500 (2009): Hazardous Substances and Articles; Administration and Enforcement Regulations 202
16 CFR Part 1500.44 (2009): Method for Determining Extremely Flammable and Flammable Solids 202
16 CFR Part 1507 (2002): Fireworks Devices 202
16 CFR Part 1630 (2007): Standard for the Surface Flammability of Carpets and Rugs 804.4.1
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
CSA Canadian Standards Association
8501 East Pleasant Valley Road Cleveland, OH 44131
AAMA/WDMA/CSA 101/I.S.2/A440—17: North American Fenestration Standard/Specifications for Windows, Doors and Unit
Skylights
1709.5.1, 2405.5
ASME A17.1—2019/CSA B44-—2019 the edition as referenced in : Safety Code for Elevators and Escalators , California Code of
Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders
907.3.3, 911.1.6, 1009.4.1, 1607.11.1, 3001.2, Table 3001.3, 3001.5, 3002.5, 3003.2, 3007.1, 3008.1.4, 3008.7.1
ASME A17.7—2007/CSA B44.7—07(R2017): Performance-based Safety Code for Elevators and Escalators
Table 3001.3, 3001.5, 3002.5
CSSB Cedar Shake & Shingle Bureau
P. O. Box 1178 Sumas, WA 98295-1178
CSSB—97: Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle
Bureau
Table 1507.8.5, Table 1507.9.6
DASMA Door & Access Systems Manufacturers Association International
1300 Sumner Avenue Cleveland, OH 44115
ANSI/DASMA 103—2017: Standard for Counterbalance Systems on Residential Sectional Garage Doors
1210.4 ANSI/DASMA 107—2017: Room Fire Test Standard for Garage Doors Using Foam Plastic…¶
ANSI/DASMA 107—2017: Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation
2603.4.1.9
ANSI/DASMA 108—2017: Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of
Structural Performance Under Uniform Static Air Pressure Difference
1709.5.2.1
ANSI/DASMA 115—2017: Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of
Structural Performance Under Missile Impact and Cyclic Wind Pressure
1609.2.3
DHA Decorative Hardwoods Association
42777 Trade West Dr Sterling, VA 20166
ANSI/HPVA HP-1—2016: American National Standard for Hardwood and Decorative Plywood
2303.3, 2304.7
DOC U.S. Department of Commerce National Institute of Standards and Technology
100 Bureau Drive Gaithersburg, MD 20899
PS 1—19: Structural Plywood
2303.1.5, 2304.7, Table 2304.8(4), Table 2304.8(5), Table 2306.2(1), Table 2306.2(2)
PS 2—18: Performance Standard for Wood-based Structural-use Panels
2303.1.5, 2304.7, Table 2304.8(5), Table 2306.2(1), Table 2306.2(2)
PS 20—05: American Softwood Lumber Standard
202, 1810.3.2.4, 2303.1.1
35-26 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
DOL U.S. Department of Labor Occupational Safety and Health Administration
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20210 29 CFR Part 1910.1000 (2015): Air Contaminants 202
DOTn U.S. Department of Transportation Office of Hazardous Material Safety
1200 New Jersey Avenue, SE East Building, 2nd Floor
Washington, DC 20590 49 CFR 173.192—2011: Packaging for Certain Toxic Gases in Hazard Zone A Table 415.6.5
49 CFR Parts 100–185—2015: Hazardous Materials Regulations 202
49 CFR Parts 173–178—2015: Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers
202
49 CFR Parts 173.137—(2009): Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group 202
EN European Committee for Standardization
Rue de la Science 23 B Brussels, Belgium 1040 Belgium EN 459-1—15: Building Lime. Definitions, Specifications and Conformity Criteria
2109.2.4.8.7
FEMA Federal Emergency Management Agency
500 C Street S.W. Washington, DC 20472 FEMA-TB-11—01: Crawlspace Construction for Buildings Located in Special Flood Hazard Areas
1805.1.2.1
FM FM Approvals Headquarters Office 1151 Boston-Providence Turnpike P.O. Box 9102 Norwood, MA 02062 FM 1950—2016: American National Standard for Seismic Sway Braces for Pipe, Tubing and Conduit
1705.14.2, 1705A.14.2 3260—00: Radiant Energy-Sensing Fire Detectors for Automatic Fire Alarm Signaling 3011—99: Approval Standard for Central Station Service for Fire Alarm and Protective Equipment Supervision 907.6.6.3
FM 4430—12: Approved Standard for Smoke and Heat Vents
910.3.2 4430—80: Acceptance Criteria for Smoke and Heat Vents 910.3.1
4430—2012: Approval Standard for Heat and Smoke Vents 910.3.1
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
FM—continued
4450—(1989): Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992 1510.2
4470—2016: Approval Standard for Single-ply Polymer-modified Bitumen Sheet, Built-up Roof (BUR) and Liquid Applied Roof Assemblies for Use in Class 1 and Noncombustible Roof Deck Construction
1504.8
4474—2011: American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures
1504.4.1, 1504.4.2, 1504.4.3
4880—2017: American National Standard for Evaluating the Fire Performance Insulated Building Panel Assemblies and Interior Finish Materials
2603.4, 2603.9
GA Gypsum Association 962 Wayne Avenue, Suite 620 Silver Spring, MD 20910
GA 216—2018: Application and Finishing of Gypsum Panel Products
Table 2508.1, 2509.2
GA 600—2018: Fire-resistance and Sound Control Design Manual, 22nd Edition
Table 721.1(1), Table 721.1(2), Table 721.1(3)
ICC International Code Council, Inc. 500 New Jersey Ave NW 6th Floor Washington, DC 20001
ICC 300—17: ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands
1030.1.1, 1030.7, 1607.19
ICC 400—17: Standard on Design and Construction of Log Structures
2302.1
ICC 500—2020: ICC/NSSA Standard for the Design and Construction of Storm Shelters
202, 423.1, 423.2, 423.3.1, 423.3.2, 423.4, 423.5, 1031.2, 1604.5.1, 1604.10
ICC 600—2020: Standard for Residential Construction in High-wind Regions
1609.1.1, 1609.1.1.1, 2308.2.4
ICC 900/SRCC 300—2020: Solar Thermal System Standard
3111.2.1
ICC 901/SRCC 100—2020: Solar Thermal Collector Standard
3111.2.1
_ICC-ES AC 01—21: Acceptance Criteria for Expansion Anchors in Masonry Elements_*
1617A.1.19
_ICC-ES AC 58—21: Acceptance Criteria for Adhesive Anchors in Masonry Elements_*
1617A.1.19
_ICC-ES AC 70—21: Acceptance Criteria for Fasteners Power-Driven into Concrete, Steel and Masonry Elements_*
1617A.1.20
ICC-ES AC 77: Acceptance Criteria for Smoke Containment Systems Used with Fire-resistance-rated
Elevator Hoistway Doors and Frames
707.14.1
_ICC-ES AC 106—21: Acceptance Criteria for Predrilled Fasteners (Screw Anchors) in Masonry_*
1617A.1.19
_ICC-ES AC 125—21: Acceptance Criteria for Concrete and Reinforced and Unreinforced Masonry Strengthening_*
Using Externally Bonded Fiber-Reinforced Polymer (FRP) Composite Systems
1911A.3, 1911.3
_ICC-ES AC 156—21: Acceptance Criteria for Seismic Certification by Shake-Table Testing of Nonstructural Components_*
1705A.14.3
35-28 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ICC—continued
_ICC-ES AC 178—21: Acceptance Criteria for Inspection and Verification of Concrete, and Reinforced and Unreinforced Masonry_*
Strengthening Using Fiber-Reinforced Polymer (FRP) Composite Systems
1911A.3, 1911.3 _ICC-ES AC 193—21: Acceptance Criteria for Mechanical Anchors in Concrete Elements_*
1617A.1.19, 1901.3.2 _ICC-ES AC 232—21: Acceptance Criteria for Anchor Channels in Concrete Elements_*
1617A.1.19, 1901.3.2 _ICC-ES AC 308—21: Acceptance Criteria for Post-Installed Adhesive Anchors in Concrete Elements_*
1617A.1.19, 1901.3.3 ICC-ES AC 331: Acceptance Criteria for Smoke and Heat Vents
910.3.1 _ICC-ES AC 358—21: Acceptance Criteria for Helical Foundation Systems and Devices_*
1810A.3.1.5.1, 1810.3.1.5.1 _ICC-ES AC 446—21: Acceptance Criteria for Headed Cast-in Specialty Inserts in Concrete_*
1617A.1.19, 1901.3.2 ICC 1100—18: Standard for Spray-applied Foam Plastic Insulation
2603.1.1
ICC A117.1—17: Accessible and Usable Buildings and Facilities
202, 907.5.2.3.3, 1009.8.2, 1009.9, 1009.11, 1010.2.13.1, 1012.1, 1012.6.5, 1012.10, 1013.4, 1023.9, 1102.1, 1108.2, 1110.1, 1110.2, 1110.5.1, 1110.5.2, 1112.3, 1112.4, 1112.5, 1112.5.2, 1207.1
SBCCI SSTD 11—97: Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles
1504.3.1.1, 1504.3.1.2, 1504.3.1.3
* Refers to International Building Code, 2021 as a reference standard.
ISO International Organization for Standardization
Chemin de Blandonnet 8
CP 401 1214 Vernier
Geneva, Switzerland ISO 668—2013: Series 1 Freight Containers—Classifications, Dimensions and Ratings
Table 3115.8.5.3
ISO 1496-1—2013: Series 1 Freight Containers—Specification and Testing - Part 1: General Cargo Containers for General Purposes
3115.8, Table 3115.8.5.3
ISO 6346—1995: Freight Containers—Code, Identification and Marking with Amendment 3 - 2012
3115.3
ISO 8115—86: Cotton Bales—Dimensions and Density
Table 307.1(1), Table 415.11.1.1.1
ISO 8336—09: Fiber-cement Flat Sheets—Product Specification and Test Methods
1403.10, 1404.16.1, 1404.16.2, Table 2509.2
ISO 9001—15: Quality Management Systems - Requirements
1705A.14.3
MHI Material Handling Institute 8720 Red Oak Blvd. Suite 201 Charlotte, NC 28217 ANSI MH29.1—08: Safety Requirements for Industrial Scissors Lifts
Table 3001.3
ANSI/MH16.1—12: Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks
Table 1705.13.7
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NAAMM National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312 Glen Ellyn, IL 60137 FP 1001—07: Guide Specifications for Design of Metal Flag Poles
1609.1.1
NCMA National Concrete Masonry Association
13750 Sunrise Valley Herndon, VA 20171 TEK 5—8B(2005): Details for Concrete Masonry Fire Walls
Table 721.1(2)
NEHRP Building Seismic Safety Council National Institute of Building Sciences
1090 Vermont Avenue NW Suite 700 Washington, DC 20005 FEMA P-2082—1: Recommended Seismic Provisions for New Building and Other Structures, Volume 1, September 2020
1617A.1.3
NFPA National Fire Protection Association
1 Batterymarch Park Quincy, MA 02169-7471 04—21: Standard for Integrated Fire Protection and Life Safety System Testing 901.6.2.1, 901.6.2.2
10— 21 : Standard for Portable Fire Extinguishers 906.2, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4
11—16: Standard for Low-, Medium, and High Expansion Foam 904.7, 3109F
12—15: Standard on Carbon Dioxide Extinguishing Systems 904.8, 904.13
12A—18: Standard on Halon 1301 Fire Extinguishing Systems 904.9
13— 22 : Standard for Installation of Sprinkler Systems _as amended_* 403.3.3, 712.1.3.1, 903.3.1.1, 903.3.2, 903.3.8.2, 903.3.8.5, 904.13, 905.3.4, 907.6.4, 1019.3
*NFPA 13, Amended Sections as follows:
Revise Section 2.2 and add publications as follows: 2.2 NFPA Publications. NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2013 California edition.
_Revise Section 6.4.3.1.1 as follows:_* _6.4.3.1.1_* Pipe joints shall not be located under foundation footings. The pipe under the building or building foundation shall not contain mechanical joints.
Exceptions: 2. Where allowed in accordance with Section 6.4.3.1. 3. Alternate designs may be utilized where designed by a registered professional engineer and approved by the enforcing agency.
Delete Sections 8.15.5.1 and 8.15.5.2
_8.15.5.1 Reserved._*
8.15.5.2 Reserved.
35-30 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Revise Section 9.2.1.16 as follows:
9.2.1.16 Exterior columns under 10 ft 2 (0.93m 2 ) in total area, formed by studs or wood joist, with no sources of ignition within the column, supporting exterior canopies that are fully protected with a sprinkler system, shall not require sprinkler protection.
_Revise Section 9.2.3.1 as follows:_* _9.2.3.1_* Sprinklers shall be permitted to be omitted where the exterior canopies, roofs, portecocheres, balconies, decks or similar projections are constructed with materials that are noncombustible, limited-combustible or fire retardant treated wood as defined in NFPA 703, Standard for Fire Retardant–Treated Wood and Fire-Retardant Coatings for Building Materials.
Delete Section A.9.2.3.1 of Annex
Revise Section 9.2.3.2 9.2.3.2 Sprinklers shall be permitted to be omitted from below the canopies, roofs, balconies, decks or similar projections are combustible construction, provided the exposed finish material on the roof, or canopy is noncombustible, limited-combustible or fire retardant treated wood as defined in NFPA 703, Standard for Fire Retardant–Treated Wood and Fire-Retardant Coatings for Building Materials, and the roofs or canopies contains only sprinklered concealed spaces or any of the following unsprinklered combustible concealed spaces:
(1) Combustible concealed spaces filled entirely with noncombustible insulation. (2) Light or ordinary hazard occupancies where noncombustible or limited-combustible ceilings are directly attached to the bottom of solid wood joists so as to create enclosed joist spaces 160 ft 3 (4.5 m 3 ) or less in volume, including space below insulation that is laid directly on top or within the ceiling joists in an otherwise sprinklered attic [See 11.2.3.1.5.2(9) ]. (3) Concealed spaces over isolated small roofs or canopies not exceeding 55 ft 2 (5.1 m 2 ).
Delete language to section 9.2.3.3 and reserve section number. 9.2.3.3 Reserved. Revise Section 9.3.6.1 as follows:
9.3.6.1 Automatic fire sprinklers shall not be required in elevator machine rooms, elevator machinery spaces, control spaces or hoistways of traction elevators installed in accordance with the applicable provisions in the California Building Code, where all of the following conditions are met:
(1) The elevator machine room, machinery space, control room, control space or hoistway of traction elevator is dedicated to elevator equipment only. (2) The elevator machinery space, control room, control space or hoistway of traction elevators is separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire resistance rating of not less than that specified by the applicable building code. (3) No materials unrelated to elevator equipment are permitted to be stored in elevator machine rooms, machinery spaces, control rooms, control spaces or hoistways of traction elevators. (4) The elevator machinery is not of the hydraulic type.
Add new Section 9.3.6.1.1 as follows:
9.3.6.1.1 The sprinkler required at the top and bottom of the elevator hoistway by 8.15.5.6 shall not be required where permitted by Chapter 30 of the California Building Code.
_Revise Section 9.3.19.1 as follows:_*
_9.3.19.1_* Unless the requirements of 9.2.3.1 or 9.2.3.2 are met, sprinklers shall be installed under exterior roofs, canopies, porte- cochere, balconies, decks or similar projections exceeding 4 ft (1.2 m) in width.
Revise Annex Section A9.3.19.2 as follows: A9.3.19.2 The presence of planters, newspaper machines and similar items, should not be considered storage.
Add Section 9.3.19.3 as follows: 9.3.19.3 Sprinklers may be omitted for following structures:
(1) Solar photovoltaic panel structures with no use underneath. Signs may be provided, as determined by the enforcing agency prohibiting any use underneath including storage. (2) Solar photovoltaic (PV) panels supported by framing that have sufficient uniformly distributed and unobstructed openings throughout the top of the array (horizontal plane) to allow heat and gases to escape, as determined by the enforcing agency.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Add new Sections 16.9.3.1.3.4 and 16.9.3.1.3.5 as follows: 16.9.3.1.3.4 Where a system includes floor control valves, a hydraulic design information sign containing information for the floor shall be provided at each floor control valve. A hydraulic design information sign shall be provided for each area calculated. The installing contractor shall identify a hydraulically designed sprinkler system with a permanently marked weatherproof metal or rigid plastic sign secured with corrosion resistant wire, chain or other approved means. Such signs shall be placed at the alarm valve, dry pipe valve, preaction valve or deluge valve supplying the corresponding hydraulically designed area.
each area calculated. The_ installing contractor shall identify a hydraulically designed sprinkler system with a permanently marked weatherproof metal or rigid plastic sign secured with corrosion resistant wire, chain or other approved means. Such signs shall be placed at the alarm valve, dry pipe valve, preaction valve or deluge valve supplying the corresponding hydraulically designed area.
16.9.3.1.3.5 Control valves, check valves, drain valves, antifreeze valves shall be readily accessible for inspection, testing and maintenance. Valves located more than 7 feet above the finished floor shall be provided with a means of opening and closing the valve from the floor level.
Add new Sections 16.9.10.5, 16.9.10.5.1, 16.9.10.5.1.1, 16.9.10.5.1.2, 16.9.10.5.1.3, 16.9.10.5.1.4, 16.9.10.5.2 as follows: 16.9.10.5 Sectional Valves.
16.9.10.5.1 Private fire service main systems shall have sectional control valves at appropriate points in order to permit sectionalizing the system in the event of a break or for the making of repairs or extensions.
16.9.10.5.1.1 Sectional control valves are not required when the fire service main system serves less than six fire appurtenances.
16.9.10.5.1.2 Sectional control valves shall be indicating valves in accordance with Section 16.9.3.2.
16.9.10.5.1.3 Sectional control valves shall be located so that no more than five fire appurtenances are affected by shut-down of any single portion of the fire service main. Each fire hydrant, fire sprinkler system riser, and standpipe riser shall be considered a separate fire appurtenance. In-rack sprinkler systems shall not be considered as a separate appurtenance.
16.9.10.5.1.4 The number of fire appurtenances between sectional control valves is allowed to be modified by the authority having jurisdiction.
16.9.10.5.2 A valve shall be provided on each bank where a main crosses a body of water or outside the building foundation(s) where the main or section of main runs under a building.
Add new Section 17.2.2.9.1 as follows: 17.2.2.9.1 Powder-driven studs used for attaching hangers to the building structure are prohibited in Seismic design Categories C, D, E and F.
Revise Section 18.5.11.4 as follows: 18.5.11.4 Where threaded pipe is used for sway bracing, it shall have a wall thickness of not less than Schedule 40.
Replace Section 18.5.12.5 as follows: 18.5.12.5 Lag screws or power-driven fasteners shall not be used to attach braces to the building structure.
Replace Section 18.5.12.6.1 as follows: 18.5.12.6.1 Fastening methods other than those identified in 9.3.5.12 shall not apply to other fastening methods, which shall be acceptable for use if certified by a registered professional engineer to support the loads determined in accordance with the criteria in 18.5.9. Calculations shall be submitted to the authority having jurisdiction.
Replace Section 18.5.12.6.1 as follows:* 18.5.12.6.1 Fastening methods other than those identified in 9.3.5.12 shall not apply to other fastening methods, which shall be acceptable for use if certified by a registered professional engineer to support the loads determined in accordance with the criteria in 18.5.9. Calculations shall be submitted to the authority having jurisdiction.
Revise Section 18.5.12.7.4 as follows: 18.5.12.7.4 Concrete anchors when identified in 18.5.11.11 shall be acceptable for use where designed in accordance with the requirements of the building code and certified by a registered professional engineer.
Revise Section 18.6.1(3) as follows: _18.6.1(3)_* No. 12, 440 lb (200 Kg) wire installed at least 45 degrees from the vertical plane and anchored on both sides of the pipe. Powder-driven fasteners for attaching restraint is allowed to be used provided that the restraint component does not support the dead load.
Revise Section 19.2.3.1.5.2(9) as follows: 19.2.3.1.5.2(9) Exterior columns under 10 ft 2 (0.93m 2 ) in total area, formed by studs or wood joist, with no sources of ignition within the column, supporting exterior canopies that are fully protected with a sprinkler system.
Revise Section 19.2.3.2.3.1 as follows: 19.2.3.2.3.1 Where listed quick-response sprinklers, excluding extended coverage quick-response sprinklers, are used throughout a system or portion of a system having the same hydraulic design basis, the system area of operation shall be permitted to be reduced without revising the density as indicated in Figure 19.2.3.2.3.1 when all of the following conditions are satisfied:
(1) Wet pipe system (2) Light hazard occupancy
35-32 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
(3) 20 ft (6.1 m) maximum ceiling height (4) There are no unprotected ceiling pockets as allowed by 10.2.9 and 11.2.7 exceeding 32 ft 2 (3 m 2 )
FIGURE 19.2.3.2.3.1 DESIGN AREA REDUCTION FOR QUICK-RESPONSE SPRINKLERS
Note:
–3 x y = ------- - + 55
2
For ceiling height ≥ 10 ft and ≤ 20 ft, For ceiling height < 10 ft, y = 40 For ceiling height > 20 ft, y = 0 For SI units, 1 ft = 0.31 m.
Revise Section 19.2.3.2.3.2 as follows:
–3 x y = ------- - + 55
2
19.2.3.2.3.2 The number of sprinklers in the design area shall never be less than seven.
Revise Section 20.9.5.2 as follows:
20.9.5.2 Early suppression fast-response (ESFR) sprinklers shall not be used in buildings with automatic heat or smoke vents unless the vents use a standard-response operating mechanism with a minimum temperature rating of 360ºF (182ºC) or 100ºF (56ºC) above the operating temperature of the sprinklers, whichever is higher.
23.8.1.2 Positive Alarm Sequence
23.8.1.2.1 Systems that have positive alarm features complying with 23.8.1.2 shall be permitted if approved by the authority having jurisdiction. Operation of a patient room smoke detector in Group I-2 and R-2.1 occupancies shall not include a positive alarm sequence feature.
Add Section 28.1.3(18)(e) as follows:
28.1.3(18)(e) Where a waterflow test is used for the purposes of system design, the test shall be conducted no more than 6 months prior to working plan submittal unless otherwise approved by the authority having jurisdiction.
Revise Section 29.1 as follows:
29.1 Approval of Sprinkler Systems and Private Fire Service Mains.¶
The installing contractor shall do the following:
(1) Notify the authority having jurisdiction and the property owner or property owner’s authorized representative of the time and date testing will be performed.
(2) Perform all required testing ( see Section 29.2 ). (3) Complete and sign the appropriate contractor’s material and test certificate(s) ( see Figure A.29.1 ). (4) Remove all caps and straps prior to placing the sprinkler system in service. (5) Upon system acceptance by the authority having jurisdiction a label prescribed by Title 19 California Code of Regulations, Chapter 5 shall be affixed to each system riser.
Revise Section 29.3 as follows:
29.3 Instructions.¶
The installing contractor shall provide the property owner or the property owner’s authorized representative with the following:
(1) All literature and instructions provided by the manufacturer describing proper operation and maintenance of any equipment and devices installed. (2) NFPA 25, Standard for the Inspection, testing, and maintenance of Water-Based Fire Protection Systems, 2013 California Edition. (3) Title 19, California Code of Regulations, Chapter 5, “Fire Extinguishing Systems.”
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Revise Section 29.4.1 as follows: 29.4.1 The installing contractor shall identify a hydraulically designed sprinkler system with a permanently marked weatherproof metal or rigid plastic sign secured with corrosion resistant wire, chain or other approved means. Such signs shall be placed at the alarm valve, dry pipe valve, preaction valve or deluge valve supplying the corresponding hydraulically designed area. Pipe schedule systems shall be provided with a sign indicating that the system was designed and installed as a pipe schedule system and the hazard classification(s) included in the design.
Revise Section 29.4.3 as follows: 29.4.3 The sign shall include the following information:
(1) Location of the design area or areas (2) Discharge densities over the design area or areas (3) Required flow and pressure of the system at the base of the riser. (4) Occupancy classification or commodity classification and maximum permitted storage height and configuration (5) Hose stream allowance included in addition to the sprinkler demand (6) The name of the installing contractor (7) Required flow and pressure of the system at the water supply source. (8) Required flow and pressure of the system at the discharge side of the fire pump where a fire pump is installed. (9) Type or types and number of sprinklers or nozzles installed including the orifice size, temperature rating, orientation, K-Factor, sprinkler identification number (SIN) for sprinkler heads when applicable, and response type. (10) The minimum discharge flow rate and pressure required from the hydraulically most demanding sprinkler. (11) The required pressure settings for pressure reducing valves. (12) For deluge sprinkler systems, the required flow and pressure at the hydraulically most demanding sprinkler or nozzle. (13) The protection area per sprinkler based on the hydraulic calculations. (14) The edition of NFPA 13 to which the system was designed and installed.
e required from the hydraulically most demanding sprinkler. (11) The required pressure settings for pressure reducing valves. (12) For deluge sprinkler systems, the required flow and pressure at the hydraulically most demanding sprinkler or nozzle. (13) The protection area per sprinkler based on the hydraulic calculations. (14) The edition of NFPA 13 to which the system was designed and installed.
Revise Section 29.6.1 as follows: 29.6.1 The installing contractor shall provide a general information sign used to determine system design basis and information relevant to the inspection, testing and maintenance requirements required by NFPA 25, Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems, 2013 California Edition.
13D— 22 : Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes, as amended* 903.3.1.3
**_NFPA 13D, Amended Sections as follows:_*
Revise Section 6.2.2 to read as follows: 6.2.2 Where a well, pump, tank or combination thereof is the source of supply for a fire sprinkler system, the configuration for the system shall be one of the following:
(1) The water supply shall serve both domestic and fire sprinkler systems.
(a) A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection shall return water to the tank. (b) Any disconnecting means for the pump shall be approved. (c) A method for refilling the tank shall be piped to the tank. (d) A method of seeing the water level in the tank shall be provided without having to open the tank. (e) The pump shall not be permitted to sit directly on the floor. (2) A stand-alone tank is permitted if the following conditions are met:
(a) The pump shall be connected to a 220-volt circuit breaker shared with a common household appliance (e.g., range, oven, dryer), (b) The pump shall be a stainless steel 240-volt pump, (c) A valve shall be provided to exercise the pump. The discharge of the exercise valve shall drain to the tank, and (d) A sign shall be provided stating: “Valve must be opened monthly for 5 minutes.” (e) A means for automatically refilling the tank level, so that the tank capacity will meet the required water supply duration in minutes, shall be provided. (f) A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection shall return water to the tank. (g) Any disconnecting means for the pump shall be approved. (h) A method for refilling the tank shall be piped to the tank. (i) A method of seeing the water level in the tank shall be provided without having to open the tank. (j) The pump shall not be permitted to sit directly on the floor.
35-34 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Add new Section 6.2.2.1 as follows: 6.2.2.1 Where a fire sprinkler system is supplied by a stored water source with an automatically operated means of pressurizing the system other than an electric pump, the water supply may serve the sprinkler system only.
Add new Section 6.2.4 as follows: 6.2.4 Where a water supply serves both domestic and fire sprinkler systems, 5 gpm (19 L/min) shall be added to the sprinkler system demand at the point where the systems are connected, to determine the size of common piping and the size of the total water supply requirements where no provision is made to prevent flow into the domestic water system upon operation of a sprinkler. For multipurpose piping systems, the 5 gpm (19 L/min) demand shall be added at the domestic connection nearest the design area. This demand may be split between two domestic connections at 2.5 gpm (10 L/min) each.
Revise Section 8.3.4 as follows: 8.3.4* Sprinklers shall not be required in detached garages, open attached porches, carports with no habitable space above, and similar structures.
Add new Sections 8.3.11 and 8.3.11.1 as follows:
8.3.11 Solar photovoltaic panel structures 8.3.11.1 Sprinklers shall be permitted to be omitted from the following structures:
(1) Solar photovoltaic panel structures with no use underneath. Signs may be provided, as determined by the enforcing agency prohibiting any use underneath including storage. (2) Solar photovoltaic (PV) panels supported by framing that have sufficient uniformly distributed and unobstructed openings throughout the top of the array (horizontal plane) to allow heat and gases to escape, as determined by the enforcing agency. 13R— 22 : Standard for the Installation of Sprinkler Systems in Low-rise Residential Occupancies, as amended* 903.3.1.2, 903.3.5.2, 903.4
**_NFPA 13R, Amended Sections as follows:_*
Revise Section 2.2 and add publications as follows:
2.2 NFPA Publications. NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2013 California edition.
Add new Sections 6.6.10 and 6.10.1 as follows:
6.6.10 Solar photovoltaic panel structures 6.6.10.1 Sprinklers shall be permitted to be omitted from the following structures:
(1) Solar photovoltaic panel structures with no use underneath. Signs may be provided, as determined by the enforcing agency prohibiting any use underneath including storage. (2) Solar photovoltaic (PV) panels supported by framing that have sufficient uniformly distributed and unobstructed openings throughout the top of the array (horizontal plane) to allow heat and gases to escape, as determined by the enforcing agency.
Revise Section 11.4 as follows:
11.4 Instructions.¶
The installing contractor shall provide the property owner or the property owner's authorized representative with the following:
(1) All literature and instructions provided by the manufacturer describing proper operation and maintenance of any equipment and devices installed. (2) NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems 2013 California Edition and Title 19, California Code of Regulations, Chapter 5. (3) Once the system is accepted by the authority having jurisdiction a label as prescribed by Title 19, California Code of Regulations, Chapter 5, shall be affixed to each system riser. 14—19: Standard for the Installation of Standpipe and Hose System, as amended* 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
**_NFPA 14, Amended Sections as follows:_*
Replace Section 6.3.7.1 6.3.7.1 System water supply valves, isolation control valves and other valves in fire mains shall be supervised in an approved manner in the open position by one of the following methods:
(1) Where a building has a fire alarm system or a sprinkler monitoring system installed, the valve shall be supervised by:
(a) a central station, proprietary or remote supervising station, or
(b) a local signaling service that initiates an audible signal at a constantly attended location.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
(2) Where a building does not have a fire alarm system or a sprinkler monitoring system installed, the valve shall be supervised by:
(a) Locking the valves in the open position, or
(b) Sealing of valves and an approved weekly recorded inspection where valves are located within fenced enclosures under the control of the owner.
16—19: Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems 904.7, 904.13
17—21: Standard for Dry Chemical Extinguishing Systems 904.6, 904.13
17A—21: Standard for Wet Chemical Extinguishing Systems 904.5, 904.13
20—19: Standard for the Installation of Stationary Pumps for Fire Protection 412.2.4.1, 913.1, 913.2, 913.2.1, 913.5
_24—19: Standard for Installation of Private Fire Service Mains and Their Appurtenances, as amended_* 3109F
**_NFPA 24, Amended Sections as follows:_*
Amend Section 4.2.1 as follows: Section 4.2.1. Installation work shall be done by fully experienced and responsible contractors. Contractors shall be appropriately licensed in the State of California to install private fire service mains and their appurtenances.
Revise Section 4.2.2 as follows: 4.2.2 Installation or modification of private fire service mains shall not begin until plans are approved and appropriate permits secured from the authority having jurisdiction.
Add Section 4.2.2.1 as follows: 4.2.2.1 As approved by the authority having jurisdiction, emergency repair of existing system may start immediately, with plans being submitted to the authority having jurisdiction within 96 hours from the start of the repair work.
Revise Section 5.9.5.1 as follows: 5.9.5.1 Fire department connections shall be on the street side of buildings and as approved by the authority having jurisdiction.
Add Sections 6.6.1.1, 6.6.1.2, 6.6.1.3 and 6.6.1.4 as follows: 6.6.1.1 Sectional control valves are not required when the fire service main system serves less than six fire appurtenances.
6.6.1.2 Sectional control valves shall be indicating valves in accordance with NFPA 13, Section 6.7.1.3.
6.6.1.3 Sectional control valves shall be located so that no more than five fire appurtenances are affected by shut-down of any single portion of the fire service main. Each fire hydrant, fire sprinkler system riser and standpipe riser shall be considered a separate fire appurtenance. In-rack sprinkler systems shall not be considered as a separate appurtenance.
6.6.1.4 The number of fire appurtenances between sectional control valves is allowed to be modified by the authority having jurisdiction.
Revise Section 10.4.3.1.1 as follows: 10.4.3.1.1 Pipe joints shall not be located under foundation footings. The pipe under the building or building foundation shall not contain mechanical joints.
Exceptions:
1. Where allowed in accordance with 10.4.3.2. 2. Alternate designs may be utilized where designed by a registered professional engineer and approved by the enforcing agency.
Revise Section 10.9.1 as follows: 10.9.1 Backfill shall be well tamped in layers or puddle under and around pipes to prevent settlement or lateral movement. Backfill shall consist of clean fill sand or pea gravel to a minimum 6″ below and to a minimum of 12″ above the pipe and shall contain no ashes, cinders, refuse, organic matter or other corrosive materials. Other backfill materials and methods are permitted where designed by a registered professional engineer and approved by the enforcing agency.
25—13CA: California NFPA 25 Edition (Based on the 2011 Edition) Inspection, Testing and Maintenance of Water-based Fire Protection Systems Chapter 31F, 3108F
30—21: Flammable and Combustible Liquids Code 415.6.1, 415.6.2, 507.8.1.1.1, 507.8.1.1.2
30A—21: Code for Motor Fuel Dispensing Facilities and Repair Garages 406.2.9.2
35-36 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
31—20: Standard for the Installation of Oil-burning Equipment 2113.15
32—16: Standard for Dry Cleaning Facilities, as amended* 415.9.3, 2101.1.1
**_NFPA 32, Amended Sections as follows:_*
Delete the following publications from Section 2.2:
2.2 NFPA Publications.
NFPA 10, Standard for Portable Fire Extinguishers, 2010 edition. NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2011 edition. NFPA 70, National Electrical Code ® , 2011 edition. NFPA 101 ®, Life Safety Code ® , 2009 edition. NFPA 5000 ®, Building Construction and Safety Code ®, 2009 edition.
Revise Section 4.4.1.1 as follows:
4.4.1.1 General building and structure design and construction shall be in accordance with California Building Code.
Delete language to Sections 4.4.1.2 and 4.4.1.3 and reserve section numbers.
4.4.1.2 Reserved
4.4.1.3 Reserved
Revise Section 4.4.4 as follows:
4.4.4 Means of Egress. Means of egress shall conform with the provisions of the California Building Code.
Revise Section 4.6.2 as follows:
4.6.2 Automatic Sprinkler Systems. Where required by this standard, automatic sprinkler systems shall be installed in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, and periodically inspected, tested and maintained in accordance with California Code of Regulations, Title 19, Division 1, Chapter 5.
Revise Section 4.6.4 as follows:
4.6.4 Portable Fire Extinguishers. Suitable numbers and types of portable fire extinguishers shall be installed and maintained throughout the drycleaning plant in accordance with California Code of Regulations, Title 19, Division 1, Chapter 3.
Revise Section 7.3.2 as follows:
7.3.2 Electrical Installations. Electrical equipment and wiring in a Type II drycleaning room shall comply with the provisions of California Electrical Code, for use in Class I, Division 2 hazardous locations.
37—18: Installation and Use of Stationary Combustion Engines and Gas Turbines 40—19: Standard for the Storage and Handling of Cellulose Nitrate Film 409.1
54—18: National Fuel Gas Code 58—20: Liquefied Petroleum Gas Code 415.9.2
61—20: Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities 426.1
68—13: Standard on Explosion Protection by Deflagration Venting Table 414.5.1
70—20: National Electrical Code 108.3, 406.2.7, 406.2.9, 412.5.7, 415.11.1.8, Table 509.1, 904.3.1, 907.6.1, 909.12.2, 909.16.3, 910.4.6, 1204.4.1, 2701.1, 2702.1.3, 3111.3
72—22: National Fire Alarm and Signaling Code, as amended* 407.4.4.5, 407.4.4.5.1, 901.6, 903.4.1, 904.3.5, 907.1.2, 907.2, 907.2.6, 907.2.9.3, 907.2.11, 907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.5.2.2.5, 907.6, 907.6.1, 907.6.2, 907.6.6, 907.7, 907.7.1, 907.7.2, 911.1.6, 915.4.1, 915.5.2, 915.7, 917.1, 2702.2.4, 3005.5, 3007.7, 3108F
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
**_NFPA 72, Amended Sections as follows:_*
NFPA—continued
Revise Section 10.3.1 as follows: 10.3.1 Equipment constructed and installed in conformity with this Code shall be listed for the purpose for which it is used. Fire alarm systems and components shall be California State Fire Marshal approved and listed in accordance with California Code of Regulations, Title 19, Division 1.
Revise Section 10.3.3 as follows: 10.3.3 All devices and appliances that receive their power from the initiating device circuit or signaling line circuit of a control unit shall be California State Fire Marshal listed for use with the control unit.
Revise Section 12.3.8.1 as follows: 12.3.8.1 The outgoing and return (redundant) circuit conductors shall be permitted in the same cable assembly (i.e., multiconductor cable), enclosure or raceway only under the following conditions:
(1) For a distance not to exceed 10 ft (3.0 m) where the outgoing and return conductors enter or exit the initiating device, notification appliance or control unit enclosures. (2) Single drops installed in the raceway to individual devices or appliances. (3)*In a single room not exceeding 1000 ft 2 (93 m 2 ) in area, a drop installed in the raceway to multiple devices or appliances that does not include any emergency control function devices. (4) Where the vertically run conductors are contained in a 2-hour rated cable assembly, or enclosed (installed) in a 2-hour rated enclosure or a listed circuit integrity (C.I.) cable, which meets or exceeds a 2-hour fire-resistive rating.
Revise Section 14.4.6.1 as follows: 14.4.6.1 Testing. Household fire alarm systems shall be tested in accordance with the manufacturer’s published instructions according to the methods of Table 14.4.3.2.
Revise Section 17.16 as follows: 17. 16 Fire Extinguisher Electronic Monitoring Device . A fire extinguisher electronic monitoring device shall indicate those conditions for a specific fire extinguisher required by California Code of Regulations, Title 19, Division 1, Chapter 1, Section 574.2 (c) and California Fire Code to a fire alarm control unit.
Delete the amendments to Section 21.3.6 and adopt the model text.
Revise Section 12.3.8 as follows:
12.3.8 (5) Where the vertically run conductors are contained in a 2-hour rated cable assembly, or enclosed (installed) in a 2-hour rated enclosure or a listed circuit integrity (C.I.) cable, which meets or exceeds a 2-hour fire resistive rating.
23.8.1.2 Positive Alarm Sequence 23.8.1.2.1 Systems that have positive alarm features complying with 23.8.1.2 shall be permitted if approved by the authority having jurisdiction. Operation of a patient room smoke detector in Group I-2 and R-2.1 occupancies shall not include a positive alarm sequence feature.
Revise Section 23.8.5.1.2 as follows: _23.8.5.1.2_* Where connected to a supervising station, fire alarm systems employing automatic fire detectors or waterflow detection devices shall include a manual fire alarm box to initiate a signal to the supervising station.
Exception: Fire alarm systems dedicated to elevator recall control, supervisory service and fire sprinkler monitoring as permitted in Section 17.15 of NFPA 72.
Revise Section 23.8.5.4.1 as follows: 23.8.5.4.1 Systems equipped with alarm verification features shall be permitted under the following conditions:
(1) The alarm verification feature is not initially enabled unless conditions or occupant activities that are expected to cause nuisance alarms are anticipated in the area that is protected by the smoke detectors. Enabling of the alarm verification feature shall be protected by password or limited access. (2) A smoke detector that is continuously subjected to a smoke concentration above alarm threshold does not delay the system functions of Sections 10.7 through 10.16, 23.8.1.1 or 21.2.1 by more than 30 seconds. (3) Actuation of an alarm-initiating device other than a smoke detector causes the system functions of Sections 10.7 through 10.16, 23.8.1.1 or 21.2.1 without additional delay. (4) The current status of the alarm verification feature is shown on the record of completion (see Figure 7.8.2(a), Item 4.3). (5) Operation of a patient room smoke detector in I-2 and R-2.1 occupancies shall not include an alarm verification feature.
Revise Section 29.3.1 as follows: 29.3.1 All devices, combinations of devices and equipment to be installed in conformity with this chapter shall be approved and listed by the California State Fire Marshal for the purposes for which they are intended.
35-38 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Revise Section 29.8.2.1.1 as follows: _29.8.2.1.1_* Smoke and Heat Alarms. Where connected to a supervising station unless exempted by applicable laws, codes or standards, smoke or heat alarms used to provide a fire-warning function, and when two or more alarms are installed within a dwelling unit, suite of rooms or similar area, shall be arranged so that the operation of any smoke or heat alarm causes all alarms within these locations to sound.
Note: Exception to 29.8.2.1.1 not adopted by the SFM.
Add Section 29.10.2.1 as follows: 29.10.2.1 The alarm verification feature shall not be used for household fire warning equipment.
Add Section 29.10.6.8.1 as follows: 29.10.6.8.1 The alarm verification feature shall not be used for household fire warning equipment.
80—19: Standard for Fire Doors and Other Opening Protectives 410.2.5, 509.4.2, 716.1, 716.2.5.1, 716.2.6.4, 716.2.9, 716.3.4.1, 716.3.5, 716.4.3, 1010.3.3
82—19: Standard on Incinerators and Waste and Linen Handling Systems and Equipment 713.13
85—19: Boiler and Combustion System Hazards Code 426.1
92—18: Standard for Smoke Control Systems 909.7, 909.8
99—21: Health Care Facilities Code 407.11, 422.6, 425.1
101—21: Life Safety Code 1030.6.2
105—19: Standard for Smoke Door Assemblies and Other Opening Protectives 405.4.2, 710.5.2.2, 716.2.10, 909.20.4.1
110—19: Standard for Emergency and Standby Power Systems 2702.1.3, 3111F
111—19: Standard on Stored Electrical Energy Emergency and Standby Power Systems 2702.1.3, 3111F
120—20: Standard for Fire Prevention and Control in Coal Mines 426.1
130—20: Standard for Fixed Guideway Transit and Passenger Rail Systems: 443
**_NFPA 130, Amended Sections as follows:_*
Amend Section 2.2 and amend publications to read as follows:
2.2 NFPA Publications. NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2013 California edition.
Amend Section 3.3.44.2 and amend publications to read as follows:
3.3.44.2 Open Station.* A station that is constructed such that it is directly open to the atmosphere and smoke and heat are allowed to disperse directly into the atmosphere.
The following enclosed areas in open stations are permitted:
1. Ticket/pass booths not exceeding 150 square feet (13.9 m 2 ) in area. 2. Mechanical and electrical spaces typically not used for human occupancy and necessary for the operation of a fixed guideway transit system. Such spaces shall be limited to two per level. 3. Restrooms not exceeding 150 square feet (13.9 m 2 ) in area. A maximum of four restrooms are permitted per level.
Add a new definition as 3.3.44.3 to read as follows: 3.3.44.1.1 Underground Station. A station or portion thereof that is located beneath the surface of the earth or of the water.
Amend Section 5.2.2.1 to read as follows: 5.2.2.1 Building construction for all new enclosed stations shall be not less than Type IA, Type IB or Type IIA construction and shall not exceed in area or height the limits specified in the California Building Code Table 503, for the station configuration or as determined by fire hazard analysis of potential fire exposure hazards to the structure.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Add Section 5.2.2.1.1 –5.2.2.1.3 to read as follows: 5.2.2.1.1 Underground stations shall be a minimum Type IA or Type IB constructions.
5.2.2.1.2 Open stations may be of Type IIB construction and shall not exceed in area or height as required by Table 503 for Type IIA.
5.2.2.1.3 Open at grade stations may be of any construction type allowed by the California Building Code.
Delete Section 5.2.2.2.
Amend Section 5.2.4.3 to read as follows: 5.2.4.3 Ancillary Spaces. Fire resistance ratings of separations between ancillary occupancies shall be established as required by the California Building Code .
Amend Section 5.2.4.3.1 to read as follows: 5.2.4.3.1 The following areas shall be separated by a two-hour fire barrier:
1. Electrical control rooms, auxiliary electrical rooms and associated battery rooms 2. Trash rooms 3. Train control rooms and associated battery rooms 4. Fan rooms 5. Emergency generator rooms
Amend Section 5.2.4.5 to read as follows: 5.2.4.5 Separation Between System and Nonsystem Occupancies.* All station public areas shall be fire separated from adjacent nonsystem occupancies by a one hour fire barrier, unless otherwise required by other provisions of the California Building Code.
Amend Section 5.3.1.1 to read as follows: 5.3.1.1 The provisions for means of egress for a station shall comply with Chapter 10 of the California Building Code, except as herein modified.
Amend Section 5.3.2.1 to read as follows: 5.3.2.1* The occupant load for a station shall be based on the train load of trains simultaneously entering the station on all tracks in normal traffic direction plus the simultaneous entraining load awaiting trains.
(1) The train load shall consider only one train at any one track. (2) The basis for calculating train and entraining loads shall be the peak period ridership figures as projected for design of a new system or as updated for an operating system. (3) Exiting shall be provided for occupant loads recalculated upon increase in service and/ or every five years.
Amend Section 5.3.3.5 to read as follows: 5.3.3.5 Travel Distance. The maximum travel distance on the platform to a point at which a means of egress route leaves the platform shall not exceed 91 440 mm (300 feet).
Amend Section 5.3.3.7 to read as follows:
5.3.3.7 Alternate Egress . At least two means of egress remote from each other shall be provided from each station platform as follows:
(1)*A means of egress used as a public circulation route shall be permitted to provide more than 50 percent of the required egress capacity from a station platform or other location. (2) Means of egress from separate platforms shall be permitted to converge. (3) Where means of egress routes from separate platforms converge, the subsequent capacity of the egress route shall be sufficient to maintain the required evacuation time from the incident platform. (4) Enclosed station platforms shall have a minimum of one exit within 2.5 times the least width of the enclosed station platform up to a maximum of 50 feet (insert mm) from each end. (5) Routes from platform ends into the underground guideway shall not be considered as exits for calculating exiting requirements.
Amend Section 5.3.11.1 to read as follows: 5.3.11.1 Illumination of the means of egress in stations, including escalators that are considered a means of egress, shall be in accordance with Chapter 10 of the California Building Code .
Amend Section 5.3.11.2 to read as follows: 5.3.11.2 Means of egress, including escalators considered as means of egress, shall be provided with a system of emergency lighting in accordance with Chapter 10 of the California Building Code.
35-40 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
Amend Section 5.4.1.1 to read as follows:
5.4.1.1 Enclosed stations shall be provided with a fire command center in accordance with Section 911.1.1 through 911.5 of the California Building Code.
Amend Section 5.4.4.1 to read as follows:
5.4.4.1* An automatic sprinkler protection system shall be provided where required by Section 903 of the California Building Code.
Delete Section 5.4.4.2.
Amend Section 5.4.5.1 to read as follows:
5.4.5.1* Class I standpipes shall be installed where required by Chapter 9 of the California Building Code in accordance with NFPA 14 except as modified herein.
Amend Section 7.3.2.1 to read as follows:
7.3.2.1 The fan inlet airflow hot temperature shall be determined by an engineering analysis, however, this temperature shall not be less than 482 °C ( 250 °F). Ventilation fans and related components shall be capable of withstanding the maximum anticipated plus/minus pressure transients induced by train operations.
Add Section 7.6.1.1 to read as follows:
7.6.1.1 Ventilation of stations shall not terminate at grade on any vehicle roadway.
Amend Section 7.7.1 to read as follows:
7.7.1 Operation of the emergency ventilation system components shall be capable of automatic and manual initiation in accordance with 909.12.3 of the California Building Code.
Amend Section 7.8.1 to read as follows:
7.8.1 The design of the power for the emergency ventilation system shall comply with the requirements of Article 700 of the California Electrical Code and Section 909 of the California Building Code.
170—18: Standard for Fire Safety and Emergency Symbols 1025.2.6.1
211—19: Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
221—21: Standard for High Challenge Fire Walls, Fire Walls and Fire Barrier Walls 706.2, Table 716.1(2)
252—17: Standard Methods of Fire Tests of Door Assemblies Table 716.1(1), 716.1.1, 716.1.2.2.1, 716.2.1.1, 716.2.1.2, 716.2.2.1, 716.2.2.2, 716.2.2.3.1, 716.2.5.1.1
253—19: Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source 406.2.4, 424.2, 804.2, 804.3
257—17: Standard for Fire Test for Window and Glass Block Assemblies Table 716.1(1), 716.1.1, 716.1.2.2.2, 716.3.1.1, 716.3.1.2, 716.3.2.1.3, 716.3.4
NFPA—continued 259—18: Standard Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
265—19: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls
803.5.1, 803.5.1.1
268—19: Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source 1405.1.1.1, 1405.1.1.1.1, 1405.1.1.1.2, 2603.5.7
275—17: Standard Method of Fire Tests for the Evaluation of Thermal Barriers 508.4.4.1, 509.4.1.1, 1406.10.2, 1408.10.2, 2603.4
276—19: Standard Method of Fire Tests for Determining the Heat Release Rate of Roofing Assemblies with Combustible Above-deck Roofing Components
1508.1, 2603.3, 2603.4.1.5
285—19: Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components
718.2.6, 1402.5, 1406.10.3, 1408.10.4, 1511.6.2, 2603.5.5
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
NFPA—continued
286—15: Standard Methods of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth 402.6.4.4, 424.2, 803.1.1, 803.1.1.1, 803.11, 803.12, 803.13, 1406.10.2, 1408.10.3, 2603.7, 2603.9, 2604.2.4, 2614.4, 3105.3
288—17: Standard Methods of Fire Tests of Horizontal Fire Door Assemblies Installed in Horizontal in Fire-resistance-rated Floor Systems
712.1.13.1
289—19: Standard Method of Fire Test for Individual Fuel Packages 402.6.2, 402.6.4.5, 424.2, 806.4
409—16: Standard for Aircraft Hangars 412.3.6, Table 412.3.6, 412.3.6.1, 412.5.5
418—16: Standard for Heliports 412.7.4
484—19: Standard for Combustible Metals 426.1
502—20 : Standard for Road Tunnels, Bridges, and Other Limited Access Highways 429
652—19: Standard on the Fundamentals of Combustible Dust 426.1
654—20: Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids
426.1
655—17: Standard for the Prevention of Sulfur Fires and Explosions 426.1
664—20: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities 426.1
701—19: Standard Methods of Fire Tests for Flame Propagation of Textiles and Films 410.2.6, 424.2, 806.4, 3102.3, 3102.3.1, 3102.6.1.1, 3105.3
704—17: Standard System for the Identification of the Hazards of Materials for Emergency Response 202, 415.5.2
750—19: Standard on Water Mist Fire Protection Systems 202, 904.11.1.1, 904.13
1124—17: Code for the Manufacture, Transportation and Storage and Retail Sales of Fireworks and Pyrotechnic Articles 415.6.4.1
2001—18: Standard on Clean Agent Fire Extinguishing Systems, _as amended_* 904.10
**_NFPA 2001, Amended Sections as follows:_*
Add Sections 4.3.5.1.1 and 4.3.5.2.1 to read as follows: 4.3.5.1.1 Alarms signals from the fire extinguishing system shall not interfere with the building fire alarm signal.
4.3.5.2.1 The lens on visual appliances shall be “red” in color.
Exception: Other lens colors are permitted where approved by the enforcing agency. 2010—20: Standard for Fixed Aerosol Fire-extinguishing Systems 904.12
PCI Precast Prestressed Concrete Institute
8770 West Bryn Mawr, Suite 1150 Chicago, IL 60631-3517 PCI 124—18: Specification for Fire Resistance of Precast Prestressed Concrete
722.1, 722.2.3.1
PCI 128—19: Specification for Glass Fiber Reinforced Concrete Panels
1903.3
MNL 120—17: PCI Design Handbook 8th Edition
1905A.1.1, 1905A.1.2
35-42 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
PTI Post-Tensioning Institute 38800 Country Club Drive Farmington Hills, MI 48331 PTI DC35.1—14: Recommendations for Prestressed Rock and Soil Anchors
1810A.3.10.4, 1811A.2, 1812A.4, 1812A.5, 1810.3.10.4.1, 1811.2, 1812.4, 1812.5,1813.2
PTI DC—10.5-19: Standard Requirements for Design and Analysis of Shallow Post-Tensioned Concrete Foundations on Expansive
and Stable Soils
1808.6.2
RMI Rack Manufacturers Institute 8720 Red Oak Boulevard, Suite 201 Charlotte, NC 28217 ANSI/MH16.1—12: Specification for Design, Testing and Utilization of Industrial Steel Storage Racks
2209.1
ANSI/MH16.3—16: Specification for the Design, Testing and Utilization of Industrial Steel Cantilevered Storage Racks
2209.2
SBCA Structural Building Components Association
6300 Enterprise Lane Madison, WI 53719 ANSI/FS 100—12(R2018): Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in
Exterior Wall Covering Assemblies
2603.10
SDI Steel Deck Institute 2661 Clearview Road #3 Allison Park, PA 15101 SDI NC—2017: Standard for Noncomposite Steel Floor Deck
2210.1.1.1
SDI—continued SDI RD—2017: Standard for Steel Roof Deck
2210.1.1.2
SDI-C—2017: Standard for Composite Steel Floor Deck—Slabs
2210.1.1.3
SDI-QA/QC—2017: Standard for Quality Control and Quality Assurance for Installation of Steel Deck
1705.2.2
SFM State of California Department of Forestry and Fire Protection
Office of the State Fire Marshal
P.O. Box 944246 Sacramento, CA 94246-2460 12-3: Releasing Systems for Security Bars in Dwellings
1029.4 12-7-3: Fire-testing Furnaces¶
12-7-3: Fire-testing Furnaces NA 12-7A-1: Exterior Wall Siding and Sheathing 703A.7, 707A.2 12-7A-2: Exterior Window 703A.7, 708A.2.1 12-7A-3: Under Eave 703A.7, 707A.8
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
SFM—continued
12-7A-4: Decking 703A.7, 709A.3 12-7A-4A: Decking Alternate Method A 703A.7, 709A.3 12-7A-5: Ignition Resistant Building Material 703A.7, 709A.3 12-8-100: Room Fire Tests for Wall and Ceiling Materials NA 12-10-1: Power Operated Exit Doors NA 12-10-2: Single Point Latching or Locking Devices NA 12-10-3: Emergency Exit and Panic Hardware NA (The Office of the State Fire Marshal standards referred to above are found in the California Code of Regulations, Title 24, Part 12.)
SJI Steel Joist Institute 140 Evans Street, Suite 203 Florence, SC 29501 SJI 100—20: 45th Edition Standard Specifications, Load Tables and Weight Tables for K-Series, LH-Series, DLH-Series and Joist
Girders
1604.3.3, 2203.1, 2207.1
SJI 200—15: 2nd Edition Standard Specifications, Weight Tables and Bridging Tables for CJ-Series Composite Steel Joists
1604.3.3, 2203.1, 2207.1
SPRI Single-Ply Roofing Institute 465 Waverly Oaks Road, Suite 421 Waltham, MA 02452 ANSI/SPRI RP-4—19: Wind Design Guide for Ballasted Single-ply Roofing Systems
1504.5
ANSI/SPRI VF-1—17: External Fire Design Standard for Vegetative Roofs
1505.10
ANSI/SPRI/FM 4435-ES-1—17: Wind Test Design Standard for Edge Systems Used with Low Slope Roofing Systems
1504.6
ANSI/SPRI GT-1—2016: Test Standard for Gutter Systems
1504.6.1
SRCC Solar Rating & Certification Corporation
400 High Point Drive, Suite 400 Cocoa, FL 32926 ICC 900/SRCC 300—2020: Solar Thermal System Standard
3111.2.1
ICC 901/SRCC 100—2020: Solar Thermal Collector Standard
3111.2.1
TIA Telecommunications Industry Association
1320 N. Courthouse Road #200 Arlington, VA 22201 ANSI/TIA 222-H—2017: Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support
Structures
1609.1.1, 3108.1, 3108.2
35-44 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
TMS The Masonry Society 105 South Sunset Street, Suite Q Longmont, CO 80501-6172 216—2014: Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 721.1(2), 722.1
302—2018: Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls 1208.2.1
402—2016: Building Code for Masonry Structures 1404.6, 1404.6.2, 1404.10, 1410.2.1, 1604.3.4, 1705.4, 1807.1.6.3.2, 1808.9, 2101.2, 2101.2.2, 2101A.1.3, 2104A.1.3, 2106.1, 2106A.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107A.4, 2107.5, 2107A.5, 2107.6, 2108.1, 2108.2, 2108.3, 2108.4, 2108A.4, 2109.1, 2109.1.1, 2109.2, 2110.1, 2114.1, 2114.4, 2115.1.1
403—2017: Direct Design Handbook for Masonry Structures 2101.2
404—2016: Standard for the Design of Architectural Cast Stone 2101.2
504—2016: Standard for the Fabrication of Architectural Cast Stone 2103.1
602—2016: Specification for Masonry Structures 1404.6.1, 1705.4, 1705A.4, 1705.4.1, 1807.1.6.3, 2101.2.2, 2101A.1.3, 2103.1, 2103.2.1, 2103.3, 2103A.3.1, 2103.4, 2104.1, 2104.2, 2104A.1, 2105.1, 2105A.1, 2105.2, 2105A.2, 2105.3, 2105A.3, 2106.6, 2115.1.1, 2115.8
604—2016: Standard for the Installation of Architectural Cast Stone 2104.1
TPI Truss Plate Institute 2670 Crain Highway, Suite 203 Waldorf, MD 20601 TPI 1—2014: National Design Standard for Metal-plate-connected Wood Truss Construction
2303.4.6, 2306.1
UBC International Code Council, Inc. 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 UBC Standard 15-2: Test Standard for Determining the Fire Retardancy of Roof-Covering Materials
1505.6 UBC Standard 15-3: Wood Shakes¶
UBC Standard 15-3: Wood Shakes
1505.6 UBC Standard 15-4: Wood Shingles¶
UBC Standard 15-4: Wood Shingles
1505.6 <u>UL</u>¶
UL UL LLC 333 Pfingsten Road Northbrook, IL 60062 9—2009: Fire Tests of Window Assemblies—with Revisions through February 2015 Table 716.1(1), 716.1.1, 716.1.2.2.2, 716.2.1.3, 716.3.1.1, 716.3.1.2, 716.3.2.1.3, 716.3.4, 1013.5
10A—2009: Tin Clad Fire Doors—with Revisions through July 2018 716.2.1
10B—2008: Fire Tests of Door Assemblies—with Revisions through February 2015 Table 716.1(1), 716.1.1, 716.1.2.2.1, 716.2.1.2, 716.2.2.2, 716.2.2.3.1, 716.2.5.1.1
10C—2016: Positive Pressure Fire Tests of Door Assemblies Table 716.1(1), 716.1.1, 716.1.2.2.1, 716.2.1.1, 716.2.2.1, 716.2.2.2, 716.2.2.3.1, 716.2.5.1.1, 1010.2.9.3
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
UL—continued
10D—2017: Standard for Fire Tests of Fire Protective Curtain Assemblies 716.4
13—96: Power-limited Circuit Cables 14B—2008: Sliding Hardware for Standard Horizontally Mounted Tin Clad Fire Doors—with Revisions through July 2017 716.2.1
14C—2006: Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with Revisions through July 2017 716.2.1
38—99: Manually Actuated Signaling Boxes—with Revisions through February 2, 2005, as amended .*
**_Amend Section 14.1.5 as follows:_* 14.1.5 A signaling box having a glass panel, disc, rod or similar part that must be broken to operate it for a signal or for access to its actuating means shall satisfactorily complete five part-breaking operations using the means provided with the box, without jamming of the mechanism or other interference by broken particles. It shall be practicable to remove and replace the broken parts. A signaling box shall not have a glass panel, disc, rod or similar part requiring a striking action by grasping a tool to operate it for a signal. The force required to activate controls shall be no greater than 5 pounds (22 N) of force.
**_Add Appendix B chapter to UL 38 (1999) as follows:_*
Appendix B, 14.1.5 Operation. Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist.
55A—2004: Materials for Built-up Roof Coverings 1507.10.2
103—2010: Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through March 2017 718.2.5.1
127—2011: Factory-built Fireplaces—with Revisions through July 2016 718.2.5.1, 2111.12
193 — 04: Alarm Valves for Fire-Protection Service 199—95: Automatic Sprinklers for Fire Protection Service—with Revisions through August 19, 2005 199E—2004: Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers 904.13.4.1
217—2015: Single and Multiple Station Smoke Alarms—with Revisions through November 2016 907.2.11
228—97: Door Closers/Holders, with or without Integral Smoke Detectors—with Revisions through January 26, 2006 260—04: Dry Pipe and Deluge Valves for Fire Protection Service 262—04: Gate Valves for Fire Protection Service 263—11: Fire Tests of Building Construction and Materials—with Revisions through March 2018 703.2, 703.2.1.3, 703.2.1.5, 703.2.2, 703.4, 703.4, 704.12, 705.7, 705.8.5, 707.6, 712.1.13.2, 714.4.1, 714.5.1, 715.3, Table 716.1(1), Table 716.1(3), 716.1.2.3, 716.2.5.1.1, 716.2.5.4, 716.3.2.1.1, 717.3.1, 717.5.2, 717.5.3, 717.6.1, 717.6.2, Table 721.1(1), 2103.1, 2603.5.1
268—2016: Smoke Detectors for Fire Alarm Systems-with revisions through July 2016 407.9, 907.2.6.2, 907.2.11.7
268A—09: Smoke Detectors for Duct Application—with Revisions through October 22, 2003 294—2018: Access Control System Units—with Revisions through October 2018 1010.2.11, 1010.2.12, 1010.2.13.1, 1010.2.14
300—2005(R2010): Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with Revisions through December 2014
904.13
300A—2006: Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces 904.14.1.1
305—2012: Panic Hardware—with Revisions through March 2017 1010.2.9.3
312—04: Check Valves for Fire-Protection Service 325—2017: Door, Drapery, Gate, Louver and Window Operations and Systems 406.2.1, 3110.3
35-46 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
UL—continued
346—05: Waterflow Indicators for Fire Protective Signaling Systems 464—03: Audible Signal Appliances—with Revisions through October 10, 2003 497B—04: Protectors for Data Communication and Fire Alarm Circuits 521—99: Heat Detectors for Fire Protective Signaling Systems—with Revisions through July 20, 2005 539—00: Single- and Multiple-Station Heat Detectors—with Revisions through August 15, 2005 555—2006: Fire Dampers—with Revisions through October 2016 717.3.1
555C—2014: Ceiling Dampers—with Revisions through May 2017 717.3.1
555S—2014: Smoke Dampers—with Revisions through October 2016 717.3.1
580—2006: Test for Uplift Resistance of Roof Assemblies—with Revisions through October 2018 1504.4.1, 1504.4.2
632—00: Electrically Actuated Transmitters 641—2010: Type L Low-temperature Venting Systems—with Revisions through April 2018 2113.11.1.4
710B—2011: Recirculating Systems—with Revisions through August 2014 904.13
723—2018: Test for Surface Burning Characteristics of Building Materials 202, 402.6.4.4, 406.7.2, 720.1, 720.4, 803.1.2, 803.5.2, 803.10, 803.11, 803.12, 803.13, 806.7, 1402.5, 1403.12.1, 1406.9, 1406.10.1, 1408.9, 1408.10.1, 1511.6.2, 1511.6.3, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2603.5.5, 2603.7, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.3
723S—2006: Drop-Out Ceilings Installed Beneath Automatic Sprinklers 2606.7.4
753—04: Alarm Accessories for Automatic Water Supply Valves for Fire Protection Service 790—2004: Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2018 1505.1, 2603.6, 2610.2, 2610.3
793—2008: Automatically Operated Roof Vents for Smoke and Heat—with Revisions through March 2017 910.3.1
813—96: Commercial Audio Equipment—with Revisions through December 7, 1999 857—13: Busways 1705A.14.3.1 864—2014: Control Units and Accessories for Fire Alarm Systems as amended* —with Revisions through March 2018 909.12
**_Amend No. 55.1 as follows:_*
RETARD-RESET-RESTART PERIOD – MAXIMUM 30 SECONDS — No alarm obtained from control unit. Maximum permissible time is 30 seconds.
**_Amend Section 55.2.2 as follows:_* Where an alarm verification feature is provided, the maximum retard-reset-restart period before an alarm signal can be confirmed and indicated at the control unit, including any control unit reset time and the power-up time for the detector to become operational for alarm, shall not exceed 30 seconds. (The balance of the section text is to remain unchanged).
**_Add Section 55.2.9 as follows:_* Smoke detectors connected to an alarm verification feature shall not be used as releasing devices.
Exception: Smoke detectors which operate their releasing function immediately upon alarm actuation independent of alarm verification feature.
**_Amend Section 89.1.10 as follows:_* The existing text of this section is to remain as printed with one editorial amendment as follows:
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 30 SECONDS. (The balance of the section text is to remain unchanged).
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
UL—continued
924—2016: Safety Emergency Lighting and Power Equipment—with Revisions through May 2018 1013.5
1040—1996: Fire Test of Insulated Wall Construction—with Revisions through April 2017 1406.10.2, 2603.9
1256—02: Fire Test of Roof Deck Construction—with Revisions through August 2018 1508.1, 2603.3, 2603.4.1.5
1479—2015: Fire Tests of Penetration Firestops 202, 714.4.1.2, 714.4.2, 714.5.1.2, 714.5.4
1482—2011: Solid-fuel Type Room Heaters—with Revisions through August 2015 2112.2, 2112.5
1489—2016: Fire Resistant Pipe Protection Systems Carrying Combustible Liquids 403.4.8.2
1703—2002: Flat-plate Photovoltaic Modules and Panels—with Revisions through September 2018 1507.17.5, 3111.3.1
1715—97: Fire Test of Interior Finish Material—with Revisions through April 2017 1406.10.2, 2603.9, 2614.4
1741—2010: Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources— with Revisions through February 2018
3111.3.1
1777—2007: Chimney Liners—with Revisions through April 2014 2113.11.1, 2113.19
1784—2015: Air Leakage Tests of Door Assemblies 405.4.3, 710.5.2.2, 710.5.2.2.1, 716.2.1.4, 716.2.9.1, 716.2.9.3, 3006.3, 3007.6.3, 3008.6.3
1897—2015: Uplift Tests for Roof Covering Systems 1504.4.1, 1504.4.3
1975—06: Fire Tests for Foamed Plastics Used for Decorative Purposes 402.6.2, 402.6.4.5, 424.2
1994—2015: Luminous Egress Path Marking Systems 411.6, 1008.2.1, 1025.2.1, 1025.2.3, 1025.2.4, 1025.2.5, 1025.4
2034—2017: Single- and Multiple-station Carbon Monoxide Alarms—with Revisions through September 2018 915.4.2, 915.4.4
2075—2013: Standard for Gas and Vapor Detectors and Sensors—with Revisions through December 2017 915.5.1, 915.5.3
2079—2015: Tests for Fire Resistance of Building Joint Systems 202, 715.3.1, 715.8
2196—2017: Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables 909.20.7.1, 913.2.2, 2702.3, 3007.8.1, 3008.8.2
2200—2012: Stationary Engine Generator Assemblies—with Revisions through October 2015 2702.1.1
2202—2009: Electric Vehicle (EV) Charging System Equipment—with Revisions through February 2018 406.2.7
2594—2016: Electric Vehicle Supply Equipment 406.2.7
2703—2014: Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-plate Photovoltaic Modules and Panels—with Revisions through December 2019
1505.9
7103—19: Outline of Investigation for Building-Integrated Photovoltaic Roof Coverings Table 1504.2, 1507.16.6
61730-1—2017: Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction 1507.16.6, 1507.17.5, 1511.9, 3111.3.1
61730-2—2017: Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing 1507.16.6, 1507.17.5, 1511.9, 3111.3.1
35-48 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
REFERENCED STANDARDS
ULC Underwriters Laboratories of Canada
13775 Commerce Parkway Richmond, BC V6V 2V4 CAN/ULC S 102.2—2018: Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and
Miscellaneous Materials and Assemblies
720.2, 720.3, 720.4
USC United States Code 732 North Capitol Street NW Washington, DC 20401-0003 18 USC Part 1, Ch. 40: Importation, Manufacture, Distribution and Storage of Explosive Materials 202
WCLIB West Coast Lumber Inspection Bureau
P.O. Box 23145 Portland, OR 97223 AITC 104—03: Typical Construction Details
2306.1
AITC 110—01: Standard Appearance Grades for Structural Glued Laminated Timber
2306.1
AITC 111—05: Recommended Practice for Protection of Structural Glued Laminated Timber During Transit, Storage and Erection
2303.1.3.1
AITC 113—10: Standard for Dimensions of Structural Glued Laminated Timber
2306.1
WCLIB—continued
AITC 119—96: Standard Specifications for Structural Glued Laminated Timber of Hardwood Species
2306.1
AITC 200—09: Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber
2306.1
AITC 404—05: Standard for Radially Reinforcing Curved Glued Laminated Timber Members to Resist Radial Tension
2303.1.3.1
WDMA Window and Door Manufacturers Association
2025 M Street NW, Suite 800 Washington, DC 20006 AAMA/WDMA/CSA 101/I.S.2/A440—17: Specifications for Windows, Doors and Unit Skylights
1709.5.1, 2405.5
WRI Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300 Hartford, CT 06103 WRI/CRSI—81: Design of Slab-on-ground Foundations—with 1996 Update
1808.6.2
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
35-50 2022 CALIFORNIA BUILDING CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Building Code (Title 24, Part 2)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix G — FLOOD-RESISTANT
- Appendix L — EARTHQUAKE RECORDING
- Appendix M — TSUNAMI-GENERATED
- Appendix N — REPLICABLE
- Appendix O — PERFORMANCE-BASED
- Chapter 1 — SCOPE AND ADMINISTRATION
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11A — HOUSING ACCESSIBILITY
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
- Chapter 12 — INTERIOR ENVIRONMENT
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 22 — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U – AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix F — RODENTPROOFING
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
- Appendix P — EMERGENCY HOUSING