MEAT AND POULTRY PROCESSING PLANTS

1240.1 General construction.

The buildings shall be of sound construction and kept in good repair.

1240.1.1 The doors, windows, skylights and other outside openings of the plant, shall be protected by fitted screens or other devices, such as air screens, against the entrance of flies and other insects.

1240.1.2 Outside doors shall be hung so as to be close fit- ting when closed.

1240.1.3 Rooms or compartments used for edible products shall be separated and distinct from inedible products departments and from rooms where live poultry are held or slaughtered. Separate rooms shall be provided when required for conducting processing operations in a sani- tary manner; and all rooms shall be able to accommodate equipment for processing operations.

Note: In the event of specific conflict, in federally inspected plants, between the provisions of Title 24 and federal regulations, the federal regulations shall take precedence.

1240.1.4 The rooms and compartments in which any prod- uct is prepared or handled shall be free from objection- able odors.

1240.1.5 The outer premises of every official establish- ment, including docks and areas where cars and vehicles

12-106 2022 CALIFORNIA BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

are loaded, and the driveways, approaches, yards, pens and alleys shall be paved.

1240.2 Refuse rooms.

A separate refuse room shall be required in official establishments where accumulations of refuse occur. Refuse rooms shall be entirely separate from other rooms in the establishment, and shall provide for the following:

1. Tight fitting doors.

2. Ventilation.

3. Drainage.

4. Cleanup facilities.

5. Floors and walls to a height of 6 feet (1829 mm) above the floor shall be impervious to moisture.

6. Wall above 6 feet (1829 mm), and ceilings shall be moisture resistant.

1240.3 Rooms for holding carcasses for further inspection.

Room or other acceptable facilities in which carcasses or parts thereof are held for further inspection shall be in such numbers and such locations as needs of the inspection in the establishment may require. These rooms or facilities shall be equipped with hasps for locking.

1240.4 Coolers and freezers.

Coolers and freezers shall be of adequate size and capacity and have cooling capability to fully enable compliance with the regulations governing the inspection of meat and poultry and meat and poultry prod- ucts.

1240.5 Boiler room.

The boiler room shall be a separate room where necessary to prevent dirt and objectionable odors entering from it into any room where dressed poultry or poultry products are prepared, handled or stored.

1240.6 Inspector’s office.

Office space for the use of govern- ment personnel shall be provided. The room or space must meet the approval of the inspection service and provide for the following:

1. Light 2. Heat

3. Ventilation

4. Desk space

5. File cabinets

1240.7 Facilities for program employees.

Establishments shall have facilities for program employees.

1240.8 Lunch rooms.

Lunch rooms or lunch areas separate from the processing, packing or supply rooms shall be pro- vided in establishments where employees eat their lunches.

1240.9 Floors.

All floors in rooms where exposed products are prepared or handled shall be constructed of, or finished with, materials impervious to moisture. The floors in killing, ice cooling, ice packing, eviscerating, cooking, boning and cannery rooms shall be graded for complete runoff with no standing water.

1240.10 Walls, posts, partitions and doors.

All walls, posts, partitions and doors in rooms where exposed products are

INTERIOR ENVIRONMENT

prepared or handled shall be smooth and constructed of materials impervious to moisture to a height of at least 8 feet (2438 mm) above the floor. All surfaces above this height must be smooth and finished with moisture-resistant material.

1240.11 Ceilings.

Ceilings must be moisture resistant in rooms where exposed products are prepared or handled, fin- ished and sealed.

1240.12 Rails.

Rails should be located and passageway space provided so that exposed product does not come in contact with posts, walls and other fixed parts of the building or with barrels, boxes or other containers trafficked through holding and operation areas.

1240.13 Lighting.

There shall be either natural or artificial light or both for all rooms and compartments.

1240.13.1 All rooms in which poultry or livestock are killed, eviscerated or otherwise processed shall have at least 30 foot-candles (323 lux) of light intensity on all working surfaces.

Exceptions:

1. At the inspection stations such light intensity shall be at least 50 footcandles (538 lux).

2. In all other rooms in which poultry or livestock are not killed, eviscerated or otherwise pro- cessed, there shall be provided at least 5 footcan- dles (54 lux) of light intensity when measured at a distance of 30 inches (762 mm) from the floor.

1240.14 Ventilation.

There shall be either natural or artifi- cial ventilation, adequate to control odors, vapors and con- densation to the extent necessary to prevent adulteration of product and the creation of insanitary conditions, in all rooms and compartments.

1240.14.1 Freezing rooms, other than those for plate freezers or liquid freezing, shall have forced-air circula- tion, and freezers and coolers shall be equipped with floor racks or pallets unless other means are used which will assure that products will be maintained in a wholesome condition. 1240.14.2 Toilet rooms shall be ventilated to the outside of the building.

1240.15 Lavatories, toilets and other sanitary facilities.

1240.15.1 Lavatory and toilet accommodations, including but not limited to, running hot and cold water, shall be provided as follows in Table 1240.15.1.

TABLE 1240.15.1

PERSONS OF SAME SEX TOILET BOWLS
REQUIRED
1 to 15, inclusive 1
1 to 15, inclusive 2
1 to 15, inclusive 3*
1 to 15, inclusive 4∗
For each additional 30 persons in excess of 80 1∗

* Urinals may be substituted for toilet bowls, but only to the extent of one- third of the total number of bowls stated.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

INTERIOR ENVIRONMENT

1240.15.2 Lavatories shall be in or adjacent to toilet and locker rooms and at other places in the plant to provide for the cleanliness of all personnel handling products.

1240.15.3 Toilet rooms opening directly into rooms where products are exposed shall have self-closing doors.

1240.15.4 Dressing rooms and toilet rooms shall be pro- vided in each establishment and shall be ample in size and readily accessible. They shall be separated from the rooms and compartments in which products are prepared, stored or handled. Where both sexes are employed, separate facilities shall be provided.

1240.15.5 Lockers or other facilities shall be provided for employees’ wearing apparel and for the storing and changing of clothing. Lockers shall not be located in rooms where processing operations are conducted.

1240.15.6 Handwashing facilities serving areas where dressed livestock and poultry carcasses and parts and meat and poultry products are prepared shall be operated by other than hand-operated controls, or shall be continu- ous flow type that provides flow of water for washing hands.

1240.15.7 Catch basins. All catch basins on the premises shall accommodate the provisions of Section 1243.5.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Building Code (Title 24, Part 2)
California Building Code (Title 24, Part 2)
  1. Chapter 2 — DEFINITIONS AND ABBREVIATIONS
  2. Appendix G — FLOOD-RESISTANT
  3. Appendix L — EARTHQUAKE RECORDING
  4. Appendix M — TSUNAMI-GENERATED
  5. Appendix N — REPLICABLE
  6. Appendix O — PERFORMANCE-BASED
  7. Chapter 1 — SCOPE AND ADMINISTRATION
  8. Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
  9. Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
  10. Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
  11. Chapter 6 — TYPES OF CONSTRUCTION
  12. Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
  13. Chapter 7A — MATERIALS AND CONSTRUCTION
  14. Chapter 8 — INTERIOR FINISHES
  15. Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
  16. Chapter 10 — MEANS OF EGRESS
  17. Chapter 11A — HOUSING ACCESSIBILITY
  18. Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
  19. Chapter 12 — INTERIOR ENVIRONMENT
  20. Chapter 14 — EXTERIOR WALLS
  21. Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
  22. Chapter 16 — STRUCTURAL DESIGN
  23. Chapter 16A — STRUCTURAL DESIGN
  24. Chapter 17 — SPECIAL INSPECTIONS AND TESTS
  25. Chapter 18 — SOILS AND FOUNDATIONS
  26. Chapter 19 — CONCRETE
  27. Chapter 20 — ALUMINUM
  28. Chapter 21 — MASONRY
  29. Chapter 22 — STEEL
  30. Chapter 23 — WOOD
  31. Chapter 24 — GLASS AND GLAZING
  32. Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
  33. Chapter 26 — PLASTIC
  34. Chapter 27 — ELECTRICAL
  35. Chapter 28 — MECHANICAL SYSTEMS
  36. Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
  37. Chapter 31 — SPECIAL CONSTRUCTION
  38. Chapter 31B — PUBLIC POOLS
  39. Chapter 31C — RADIATION
  40. Chapter 31D — FOOD ESTABLISHMENTS
  41. Chapter 31F — MARINE OIL TERMINALS
  42. Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
  43. Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
  44. Chapter 35 — REFERENCED STANDARDS
  45. Appendix A — EMPLOYEE QUALIFICATIONS
  46. Appendix B — BOARD OF APPEALS
  47. Appendix C — GROUP U – AGRICULTURAL BUILDINGS
  48. Appendix D — FIRE DISTRICTS
  49. Appendix F — RODENTPROOFING
  50. Appendix H — SIGNS
  51. Appendix I — PATIO COVERS
  52. Appendix J — GRADING
  53. Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
  54. Appendix P — EMERGENCY HOUSING

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.