1235.1 Culling plants.¶
Culling plants shall be located in areas free from unsanitary conditions and faulty sewage dis- posal. They shall be provided with an ample supply of water under adequate pressure from a source approved by the Department of Health Services for the purpose of hosing down floor and benches and cleaning the shellfish. Floors and premises shall be kept in a clean and sanitary condition.
1235.2 Plant arrangement.¶
Unless shellfish are shucked directly into packing containers with no further processing, the shucking and packing processes shall be done in separate rooms. There shall be installed in the partition between the two rooms a delivery window through which the shucked stock is passed to the packing room. Provision shall be made for storing the employees’ outer garments, aprons, gloves, etc., in a separate room.
Note: In special instances where shucking is done on a small scale for local retail sales, shucking and packing may be permitted in a single room if approved by the Department of Health Services. This single room and all operations shall conform to all requirements of these reg- ulations except that of separate shucking and packing rooms. “Limited” certificates shall be issued in these instances and all containers of shucked shellfish shall be
INTERIOR ENVIRONMENT
clearly labeled or marked with words “Limited Certifi- cate” and the appropriate certificate number.
1235.3 Floors.¶
The floors of all rooms in which shellfish are stored, shucked, washed, packed or otherwise processed shall be constructed of concrete or other equally impervious mate- rial, graded to drain quickly, free from cracks or uneven sur- faces that might interfere with proper cleaning or drainage, and maintained in clean and satisfactory condition.
1235.4 Walls and ceilings.¶
Walls and ceilings shall be main- tained in a smooth, clean, washable, light-colored conditions. They shall be impervious to moisture and shall be kept in good repair. Walls contiguous to benches shall, to a height of 2 feet (610 mm) above the bench top, be of smooth concrete, metal or equally nonabsorbent material.
1235.5 Screening.¶
The plant shall have all openings effec- tively screened, unless other effective means are provided to prevent the entrance of flies and other insects.
1235.6 Light.¶
Ample light to work by shall be provided in all working rooms. A light intensity of not less than 10 footcan- dles (108 lux) shall be maintained on all working surfaces when workers are at their working positions.
1235.7 Ventilation.¶
Adequate ventilation shall be provided to prevent condensation on ceilings or other surfaces.
1235.8 Toilet facilities.¶
Every shellfish culling, shucking, packing or repacking plant shall be provided with clean and adequate toilet facilities conveniently located. No toilet room shall be used for the storage of garments, food products, con- tainers or equipment. Construction and maintenance of toi- lets shall comply with all local and state regulations.
1235.9 Handwashing facilities.¶
An adequate number of lava- tories shall be provided at locations convenient to toilet rooms and shellfish handling operations, including running hot and cold water, soap and individual disposal towels. The use of a common towel is prohibited. All employees shall wash their hands thoroughly with running water and soap on beginning work and after each visit to the toilet. Signs to this effect shall be posted in conspicuous places in the plant and in the toilet rooms.
1235.10 Sewers and drains.¶
Sewage and other liquid wastes shall be discharged into public sewers wherever possible. Where private sewage or waste disposal systems must be uti- lized, they shall be constructed in accordance with state and local regulations pertaining thereto. Plant waste systems shall be properly trapped and vented. Waste liquids shall be disposed of in a manner that will not adversely affect the quality of the water in which shellfish are grown or stored. Waste lines from washing machines shall have suitable pro- tection against the possibility of sewage or wastes entering these machines.
1235.11 Water supply.¶
Shucking, packing or repacking plants shall be provided with an ample supply of water under adequate pressure from a source approved by the Depart- ment of Health Services. The supply shall be accessible to all parts of the plant, adequate in quantity, and of a safe sanitary quality. No cross connections with unapproved supplies or other possible sources of contamination shall be permitted.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INTERIOR ENVIRONMENT
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Building Code (Title 24, Part 2)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix G — FLOOD-RESISTANT
- Appendix L — EARTHQUAKE RECORDING
- Appendix M — TSUNAMI-GENERATED
- Appendix N — REPLICABLE
- Appendix O — PERFORMANCE-BASED
- Chapter 1 — SCOPE AND ADMINISTRATION
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11A — HOUSING ACCESSIBILITY
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
▸Chapter 12 — INTERIOR ENVIRONMENT
Overview- Section 1201
- Section 1202
- Section 1203
- Section 1204
- Section 1205
- Section 1206
- Section 1207
- Section 1208
- Section 1209
- Section 1210
- Section 1211 — [HCD 1 & HCD 2]
- Section 1212 — [HCD 1]
- Section 1213
- Section 1214
- Section 1215
- Section 1216
- Section 1217
- Section 1218
- Section 1219
- Section 1220
- Section 1221
- Section 1222
- Section 1223
- Section 1224 — [OSHPD 1]
- Section 1225 — [OSHPD 2]
- Section 1226 — [OSHPD 3]
- Section 1227 — [OSHPD 4]
- Section 1228 — [OSHPD 5]
- Section 1229
- Section 1230 — [BSCC]
- Section 1231 — [BSCC]
- Section 1232
- Section 1233
- Section 1234
- Section 1235 — [DPH]
- Section 1236 — [DPH]
- Section 1237 — [DPH]
- Section 1238
- Section 1239
- Section 1240 — [AGR]
- Section 1241 — [AGR]
- Section 1242 — [AGR]
- Section 1243 — [AGR]
- Section 1244
- Section 1245
- Section 1246
- Section 1247
- Section 1248
- Section 1249
- Section 1250 — [CA]
- Section 1251 — [CA]
- Section 1252 — [CA]
- Section 1253 — [CA]
- Section 1254 — [CA]
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 22 — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U – AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix F — RODENTPROOFING
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
- Appendix P — EMERGENCY HOUSING