Framing openings, headers, cold-formed steel and masonry wall rules

This hub orients readers to the CRC rules for headers and openings, cold‑formed steel framing limits and detailing, and masonry wall and seismic requirements.

Last reviewed: July 6, 2026

Overview

This hub covers the CRC provisions that govern the framing of openings and headers in walls, the prescriptive and material rules for cold‑formed steel (CFS) wall framing, and the masonry wall requirements (including seismic detailing). Key chapters are Chapter 6 (Wall Construction) with the CFS rules in Section R603 and masonry provisions in Section R606; header spans for CFS are set out in § R603.6 and related tables, and roof/ceiling header requirements are in § R804.3.4 .

These rules matter because they control load transfer, bracing continuity and seismic performance: allowable header spans and construction details are prescribed (see Tables R603.6(1)–(6)), fastener, splice and web‑hole rules limit how CFS members may be cut or joined, and masonry seismic detailing and minimum solid‑wall lengths are provided in § R606.12 for higher seismic design categories. See the fastening, web‑hole and anchorage requirements in § R603.2 and § R603.3 for CFS framing and the seismic/masonry provisions in § R606.12 for masonry walls .

In this section

Code references

Grounded in the retrieved California Residential Code — click a citation to read the verbatim passage:

  • CRC § 3.3 High relevance — show source text

    R804.3.3 Cutting and notching. Flanges and lips of load-bearing, cold-formed steel roof framing members shall not be cut or notched.

    R804.3.4 Headers. Roof-ceiling framing above wall openings shall be supported on headers. The allowable spans for headers in load-bearing walls shall not exceed the values set forth in Section R603.6 and Tables R603.6(1) through R603.6(6).

    R804.3.5 Framing of openings in roofs and ceilings. Openings in roofs and ceilings shall be framed with header and trimmer joists. Header joist spans shall not exceed 4 feet (1219 mm) in length. Header and trimmer joists shall be fabricated from joist and track members having a minimum size and thickness equivalent to the adjacent ceiling joists or roof rafters and shall be installed in accordance with Figures R804.3.5(1) and R804.3.5(2). Each header joist shall be connected to trimmer joists with not less than four 2-inch by 2-inch (51 by 51 mm) clip angles. Each clip angle shall be fastened to both the header and trimmer joists with four No. 8 screws, evenly spaced, through each leg of the clip angle. The steel thickness of the clip angles shall be not less than that of the ceiling joist or roof rafter. Each track section for a built-up header or trimmer joist shall extend the full length of the joist (continuous).

    FIGURE R804.3.5(1)—ROOF OR CEILING OPENING

    For SI: 1 foot = 304.8 mm.

    8-40 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    ROOF-CEILING CONSTRUCTION

    FIGURE R804.3.5(2)—HEADER TO TRIMMER CONNECTION

    MINIMUM 2 IN. × 2 IN. CLIP ANGLE WITH 4 NO. 8 SCREWS THROUGH EACH LEG, BOTH SIDES OF CONNECTION

    For SI: 1 inch = 25.4 mm.

    R804.3.6 Roof trusses. Cold-formed steel trusses shall be designed and installed in accordance with AISI S230, Section F6. In the absence of specific bracing requirements, trusses shall be braced in accordance with accepted industry practices, such as the SBCA Cold-Formed Steel Building Component Safety Information (CFSBCSI) Guide to Good Practice for Handling, Installing & Bracing of Cold-Formed Steel Trusses. Trusses shall be connected to the top track of the load-bearing wall in accordance with Table R804.3, either with the required number of No. 10 screws applied through the flange of the truss or by using a 54-mil (1.37 mm) clip angle with the required number of No. 10 screws in each leg.

    R804.3.7 Ceiling and roof diaphragms. Ceiling and roof diaphragms shall be in accordance with this section. **R804.3.7.1 Ceiling diaphragms.

  • CRC § 3.3 High relevance — show source text

    FIGURE R603.3.3(2)—STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL

    STUD/TRACK BLOCKING

    WALL FRAMING

    1½ ″ x 33 MIL FLAT STRAP

    BEND SECTION OR CLIP FLANGE TO FORM VERTICAL

    2 NO. 8 SCREWS @ STRAP TO BLOCKING

    NO. 8 SCREW

    @ EACH STRAP TO STUD

    For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm, 1 foot = 304.8 mm.

    R603.3.4 Cutting and notching. Flanges and lips of cold-formed steel studs and headers shall not be cut or notched.

    R603.3.5 Splicing. Steel studs and other structural members shall not be spliced without an approved design. Tracks shall be spliced in accordance with Figure R603.3.5.

    6-76 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    FIGURE R603.3.5—TRACK SPLICE

    For SI: 1 inch = 25.4 mm.

    R603.4 Corner framing. In exterior walls, corner studs and the top tracks shall be installed in accordance with Figure R603.4.

    FIGURE R603.4—CORNER FRAMING

    4 NO. 8 SCREWS AT LAPPED TRACK

    TRACK

    PLAN

    ALTERNATE PLAN

    For SI: 1 inch = 25.4 mm.

    R603.5 Exterior wall covering. The method of attachment of exterior wall covering materials to cold-formed steel stud wall framing shall conform to the manufacturer’s installation instructions.

    R603.6 Headers. Headers shall be installed above all wall openings in exterior walls and interior load-bearing walls. Box beam headers and back-to-back headers each shall be formed from two equal sized C-shaped members in accordance with Figures R603.6(1) and R603.6(2), respectively, and Tables R603.6(1) through R603.6(6). L-shaped headers shall be permitted to be constructed in accordance with AISI S230. Alternately, headers shall be permitted to be designed and constructed in accordance with AISI S240.

    2025 CALIFORNIA RESIDENTIAL CODE 6-77

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    TABLE R603.6(1)—BOX-BEAM AND BACK-TO-BACK HEADER SPANS
    (HEADERS SUPPORTING ROOF AND CEILING ONLY)a, b, d
    Col2 Col3 Col4 Col5 Col6 Col7 Col8 Col9 Col10 Col11
    MEMBER
    DESIGNATION
    GROUND SNOW LOAD
    (20 psf)
    GROUND SNOW LOAD
    (20 psf)
    GROUND SNOW LOAD
    (20 psf)
    GROUND SNOW LOAD
    (20 psf)
    GROUND SNOW LOAD
    (20 psf)
    GROUND SNOW LOAD
    (30 psf)
    GROUND SNOW LOAD
    (30 psf)
    GROUND SNOW LOAD
    **(30
  • CRC § 1.1.1 High relevance — show source text

    R603.1.1.1 Alternate applications. Cold-formed steel wall framing for buildings exceeding the applicability limits of Section R603.1.1 are permitted to be designed and constructed in accordance with AISI S230, subject to the limits therein.

    R603.1.2 In-line framing. Load-bearing cold-formed steel studs constructed in accordance with Section R603 shall be located inline with joists, trusses and rafters in accordance with the tolerances specified in AISI S240, Section B1.2.3.

    R603.2 Structural framing. Load-bearing cold-formed steel wall framing members shall be in accordance with this section.

    2025 CALIFORNIA RESIDENTIAL CODE 6-53

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    R603.2.1 Material. Load-bearing cold-formed steel framing members shall be cold formed to shape from structural-quality sheet steel complying with the requirements of AISI S240, Section A3.

    R603.2.2 Corrosion protection. Load-bearing cold-formed steel framing shall have a protective coating complying with AISI S240, Section A4.

    R603.2.3 Dimension, thickness and material grade. Load-bearing cold-formed steel wall framing members shall comply with the dimensional and thickness requirements specified in AISI S230, Section A4.3 and material grade requirements as specified in AISI S230, Section A4.4.

    R603.2.4 Identification. Load-bearing cold-formed steel framing members shall meet the product identification requirements of AISI S240, Section A5.5.

    R603.2.5 Fastening. Screws for steel-to-steel connections shall be installed with a minimum edge distance and center-to-center spacing of [1] / 2 inch (12.7 mm), shall be self-drilling tapping and shall conform to ASTM C1513. Structural sheathing shall be attached to cold-formed steel studs with minimum No. 8 self-drilling tapping screws that conform to ASTM C1513. Screws for attaching structural sheathing to cold-formed steel wall framing shall have a minimum head diameter of 0.292 inch (7.4 mm) with countersunk heads and shall be installed with a minimum edge distance of [3] / 8 inch (9.5 mm). Gypsum board shall be attached to cold-formed steel wall framing with minimum No. 6 screws conforming to ASTM C954 or ASTM C1513 with a bugle-head style and shall be installed in accordance with Section R702. For connections, screws shall extend through the steel not fewer than three exposed threads. Fasteners shall have rust-inhibitive coating suitable for the installation in which they are being used, or be manufactured from material not susceptible to corrosion.

    R603.2.6 Web holes, web hole reinforcing and web hole patching. Web holes in wall studs shall comply with the conditions as prescribed in AISI S230, Section A4.5. Web holes not in conformance to the conditions as prescribed in AISI S230, Section A4.5 shall be reinforced in accordance with the provisions of AISI S230, Section A4.6 or patched in accordance with the provisions of AISI S230, Section A4.7.

    R603.3 Wall construction. Exterior cold-formed steel framed walls and interior load-bearing cold-formed steel framed walls shall be constructed in accordance with the provisions of this section.

  • California Residential Code High relevance — show source text

    Chapter 1 Scope and Administration.

    Chapter 1 establishes the limits of applicability of the code and describes how the code is to be applied and enforced. The provisions of Chapter 1 establish the authority and duties of the code official appointed by the authority having jurisdiction and also establish the rights and privileges of the design professional, contractor and property owner.

    Chapter 2 Definitions.

    Chapter 2 is the repository of the definitions of terms used in the body of the code. The user of the code should be familiar with and consult this chapter because the definitions are essential to the correct interpretation of the code and because the user may not be aware that a term is defined.

    Chapter 3 Building Planning.

    Chapter 3 provides guidelines for a minimum level of structural integrity, life safety, fire safety and livability for inhabitants of dwelling units regulated by this code. Chapter 3 is a compilation of the code requirements specific to the building planning sector of the design and construction process. This chapter sets forth code requirements dealing with light, ventilation, sanitation, minimum room size, ceiling height and environmental comfort. Chapter 3 establishes life-safety provisions including limitations on glazing used in hazardous areas, specifications on stairways, use of guards at elevated surfaces, window and fall protection, and rules for means of egress. Snow, wind and seismic design live and dead loads and flood-resistant construction, as well as solar energy systems are addressed in this chapter.

    Chapter 4 Foundations.

    Chapter 4 provides the requirements for the design and construction of foundation systems for buildings regulated by this code. Provisions for seismic load, flood load and frost protection are contained in this chapter. A foundation system consists of two interdependent components: the foundation structure itself and the supporting soil.

    The prescriptive provisions of this chapter provide requirements for constructing footings and walls for foundations of wood, masonry, concrete and precast concrete. In addition to a foundation’s ability to support the required design loads, this chapter addresses several other factors that can affect foundation performance. These include controlling surface water and subsurface drainage, requiring soil tests where conditions warrant and evaluating proximity to slopes and minimum depth requirements. The chapter also provides requirements to minimize adverse effects of moisture, decay and pests in basements and crawl spaces.

    Chapter 5 Floors.

    Chapter 5 provides the requirements for the design and construction of floor systems that will be capable of supporting minimum required design loads. This chapter covers four different types: wood floor framing, wood floors on the ground, cold-formed steel floor framing and concrete slabs on the ground. Allowable span tables are provided that greatly simplify the determination of joist, girder and sheathing sizes for raised floor systems of wood framing and cold-formed steel framing. This chapter also contains prescriptive requirements for wood-framed exterior decks and their attachment to the main building.

    Chapter 6 Wall Construction.

    Chapter 6 contains provisions that regulate the design and construction of walls. The wall construction covered in Chapter 6 consists of five different types: wood framed, cold-formed steel framed, masonry, concrete and structural insulated panel (SIP). The primary concern of this chapter is the structural integrity of wall construction and transfer of all imposed loads to the supporting structure. This chapter provides the requirements for the design and construction of wall systems that are capable of supporting the minimum design vertical loads (dead, live and snow loads) and lateral loads (wind or seismic loads). This chapter contains the prescriptive requirements for wall bracing and/or shear walls to resist t

  • CRC § 12.8 Medium relevance — show source text

    R602.12.8 Stem walls. Masonry stem walls with a height and length of 48 inches (1219 mm) or less supporting a bracing unit or a Method CS-G, CS-PF or PFG braced wall panel shall be constructed in accordance with Figure R602.10.9. Concrete stem walls with a length of 48 inches (1219 mm) or less, greater than 12 inches (305 mm) tall and less than 6 inches (152 mm) thick shall be reinforced sized and located in accordance with Figure R602.10.9.

    SECTION R603—COLD-FORMED STEEL WALL FRAMING

    R603.1 General. Elements shall be straight and free of any defects that would significantly affect structural performance. Coldformed steel wall framing members shall be in accordance with the requirements of this section.

    R603.1.1 Applicability limits. The provisions of this section shall control the construction of exterior cold-formed steel wall framing and interior load-bearing cold-formed steel wall framing for buildings not more than 60 feet (18 288 mm) long perpendicular to the joist or truss span, not more than 40 feet (12 192 mm) wide parallel to the joist or truss span, and less than or equal to three stories above grade plane. Exterior walls installed in accordance with the provisions of this section shall be considered as loadbearing walls. Cold-formed steel walls constructed in accordance with the provisions of this section shall be limited to sites where the ultimate design wind speed is less than 140 miles per hour (63 m/s), Exposure Category B or C, and the ground snow load is less than or equal to 70 pounds per square foot (3.35 kPa).

    R603.1.1.1 Alternate applications. Cold-formed steel wall framing for buildings exceeding the applicability limits of Section R603.1.1 are permitted to be designed and constructed in accordance with AISI S230, subject to the limits therein.

    R603.1.2 In-line framing. Load-bearing cold-formed steel studs constructed in accordance with Section R603 shall be located inline with joists, trusses and rafters in accordance with the tolerances specified in AISI S240, Section B1.2.3.

    R603.2 Structural framing. Load-bearing cold-formed steel wall framing members shall be in accordance with this section.

    2025 CALIFORNIA RESIDENTIAL CODE 6-53

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    R603.2.1 Material. Load-bearing cold-formed steel framing members shall be cold formed to shape from structural-quality sheet steel complying with the requirements of AISI S240, Section A3.

    R603.2.2 Corrosion protection. Load-bearing cold-formed steel framing shall have a protective coating complying with AISI S240, Section A4.

    R603.2.3 Dimension, thickness and material grade. Load-bearing cold-formed steel wall framing members shall comply with the dimensional and thickness requirements specified in AISI S230, Section A4.3 and material grade requirements as specified in AISI S230, Section A4.4.

    R603.2.4 Identification. Load-bearing cold-formed steel framing members shall meet the product identification requirements of AISI S240, Section A5.5.

    **R603.2.5 Fastening.

  • CRC § 2.1. Medium relevance — show source text

    Exception: Portions of floors that do not support shear walls, braced wall panels above, or roofs shall be permitted to extend not more than 6 feet (1829 mm) beyond a shear wall or braced wall line. 3. Shear wall or braced wall offsets in plane. Conditions where the end of a braced wall panel occurs over an opening in the wall below and extends more than 1 foot (305 mm) horizontally past the edge of the opening. This provision is applicable to shear walls and braced wall panels offset in plane and to braced wall panels offset out of plane in accordance with the exception to Item 1.

    Exception: For wood light-frame wall construction, one end of a braced wall panel shall be permitted to extend more than 1 foot (305 mm) over an opening not more than 8 feet (2438 mm) in width in the wall below provided that the opening includes a header in accordance with all of the following:

    1. The building width, loading condition and framing member species limitations of Table R602.7(1) shall apply.
    2. The header is composed of: 2.1. Not less than one 2 × 12 or two 2 × 10 for an opening not more than 4 feet (1219 mm) wide. 2.2. Not less than two 2 × 12 or three 2 × 10 for an opening not more than 6 feet (1829 mm) in width. 2.3. Not less than three 2 × 12 or four 2 × 10 for an opening not more than 8 feet (2438 mm) in width.
    3. The entire length of the braced wall panel does not occur over an opening in the wall below.
    4. Floor and roof opening. Conditions where an opening in a floor or roof exceeds the lesser of 12 feet (3658 mm) or 50 percent of the least floor or roof dimension.
    5. Floor level offset. Conditions where portions of a floor level are vertically offset.

    Exceptions:

    1. Framing supported directly by continuous foundations at the perimeter of the building.
    2. For wood light-frame construction, floors shall be permitted to be vertically offset where the floor framing is lapped or tied together as required by Section R502.6.1.
    3. Perpendicular shear wall and wall bracing. Conditions where shear walls and braced wall lines do not occur in two perpendicular directions.
    4. Wall bracing in stories containing masonry or concrete construction. Conditions where stories above grade plane are partially or completely braced by wood wall framing in accordance with Section R602 or cold-formed steel wall framing in accordance with Section R603 include masonry or concrete construction. Where this irregularity applies, the entire story shall be designed in accordance with accepted engineering practice.

    Exception: Fireplaces, chimneys and masonry veneer in accordance with this code. 8. Hillside light-frame construction. Conditions in which all of the following apply: 8.1. The grade slope exceeds 1 unit vertical in 5 units horizontal where averaged across the full length of any side of the building.

    3-20 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    BUILDING PLANNING

  • CRC § 6-101 Medium relevance — show source text
    Col1 Col2 Col3

    2025 CALIFORNIA RESIDENTIAL CODE 6-101

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    FIGURE R606.11(3)—REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D 0 , D 1 OR D 2

    ROOF CONNECTORS AT 48 IN. MAX. O.C.

    #4 BARS AROUND OPENINGS

    DETAIL B

    #4 BARS WITHIN 8 IN. OF ENDS OF WALLS AND AT CORNERS

    #4 BARS AT 48 IN. O.C.

    #4 BARS (MIN.) AT DIAPHRAGMS CONT. THRU C.J.

    #4 BARS (MIN.) WITHIN 8 IN. OF ALL C.J.’S

    CONTROL JOINT (C.J.)

    24 IN. OR #4 BARS at 48 IN. O.C.

    Col1 Col2 Col3 Col4 Col5 Col6 Col7

    40 db

    MINIMUM REINFORCEMENT FOR MASONRY WALLS

    5 IN. MAX

    #3 COLUMN TIES AT 8 IN. MAX.

    Col1 Col2

    Note: A full bed joint must be provided. Cells containing vertical bars are to be filled to the top of wall and provide inspection opening as shown on detail “A.” Horizontal bars are to be laid as shown on detail “B.” Lintel bars are to be laid as shown on Section C.

    R606.12 Seismic requirements. The seismic requirements of this section shall apply to the design of masonry and the construction of masonry building elements located in Seismic Design Category D 0, D 1 or D 2 . Townhouses in Seismic Design Category C shall comply with the requirements of Section R606.12.2. These requirements shall not apply to glass unit masonry conforming to Section R607, anchored masonry veneer conforming to Section R703.8 or adhered masonry veneer conforming to Section R703.12.

    R606.12.1 General. Masonry structures and masonry elements shall comply with the requirements of Sections R606.12.2 through R606.12.4 based on the seismic design category established in Table R301.2.1(1). Masonry structures and masonry elements shall comply with the requirements of Section R606.12 and Figures R606.11(1), R606.11(2) and R606.11(3) or shall be designed in accordance with TMS 402 or TMS 403.

    R606.12.1.1 Floor and roof diaphragm construction. Floor and roof diaphragms shall be constructed of wood structural panels attached to wood framing in accordance with Table R602.3(1) or to cold-formed steel floor framing in accordance with Table R505.3.1(2) or to cold-formed steel roof framing in accordance with Table R804.3. Additionally, sheathing panel edges

  • CRC § 12.2. Medium relevance — show source text

    Note: A full bed joint must be provided. Cells containing vertical bars are to be filled to the top of wall and provide inspection opening as shown on detail “A.” Horizontal bars are to be laid as shown on detail “B.” Lintel bars are to be laid as shown on Section C.

    R606.12 Seismic requirements. The seismic requirements of this section shall apply to the design of masonry and the construction of masonry building elements located in Seismic Design Category D 0, D 1 or D 2 . Townhouses in Seismic Design Category C shall comply with the requirements of Section R606.12.2. These requirements shall not apply to glass unit masonry conforming to Section R607, anchored masonry veneer conforming to Section R703.8 or adhered masonry veneer conforming to Section R703.12.

    R606.12.1 General. Masonry structures and masonry elements shall comply with the requirements of Sections R606.12.2 through R606.12.4 based on the seismic design category established in Table R301.2.1(1). Masonry structures and masonry elements shall comply with the requirements of Section R606.12 and Figures R606.11(1), R606.11(2) and R606.11(3) or shall be designed in accordance with TMS 402 or TMS 403.

    R606.12.1.1 Floor and roof diaphragm construction. Floor and roof diaphragms shall be constructed of wood structural panels attached to wood framing in accordance with Table R602.3(1) or to cold-formed steel floor framing in accordance with Table R505.3.1(2) or to cold-formed steel roof framing in accordance with Table R804.3. Additionally, sheathing panel edges

    6-102 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    WALL CONSTRUCTION

    perpendicular to framing members shall be backed by blocking, and sheathing shall be connected to the blocking with fasteners at the edge spacing. For Seismic Design Categories C, D 0, D 1 and D 2, where the width-to-thickness dimension of the diaphragm exceeds 2-to-1, edge spacing of fasteners shall be 4 inches (102 mm) on center.

    R606.12.2 Seismic Design Category C. Townhouses located in Seismic Design Category C shall comply with the requirements of this section.

    R606.12.2.1 Minimum length of wall without openings. Table R606.12.2.1 shall be used to determine the minimum required solid wall length without openings at each masonry exterior wall. The provided percentage of solid wall length shall include only those wall segments that are 3 feet (914 mm) or longer. The maximum clear distance between wall segments included in determining the solid wall length shall not exceed 18 feet (5486 mm). Shear wall segments required to meet the minimum wall length shall be in accordance with Section R606.12.2.2.3.

  • CRC § 6.1. Medium relevance — show source text
    1. The entire length of the braced wall panel does not occur over an opening in the wall below.
    2. Floor and roof opening. Conditions where an opening in a floor or roof exceeds the lesser of 12 feet (3658 mm) or 50 percent of the least floor or roof dimension.
    3. Floor level offset. Conditions where portions of a floor level are vertically offset.

    Exceptions:

    1. Framing supported directly by continuous foundations at the perimeter of the building.
    2. For wood light-frame construction, floors shall be permitted to be vertically offset where the floor framing is lapped or tied together as required by Section R502.6.1.
    3. Perpendicular shear wall and wall bracing. Conditions where shear walls and braced wall lines do not occur in two perpendicular directions.
    4. Wall bracing in stories containing masonry or concrete construction. Conditions where stories above grade plane are partially or completely braced by wood wall framing in accordance with Section R602 or cold-formed steel wall framing in accordance with Section R603 include masonry or concrete construction. Where this irregularity applies, the entire story shall be designed in accordance with accepted engineering practice.

    Exception: Fireplaces, chimneys and masonry veneer in accordance with this code. 8. Hillside light-frame construction. Conditions in which all of the following apply: 8.1. The grade slope exceeds 1 unit vertical in 5 units horizontal where averaged across the full length of any side of the building.

    3-20 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    BUILDING PLANNING

    8.2. The tallest cripple wall clear height exceeds 7 feet (2134 mm), or where a post and beam system occurs at the building perimeter, the post and beam system tallest post clear height exceeds 7 feet (2134 mm). 8.3. Of the total plan area below the lowest framed floor, whether open or enclosed, less than 50 percent is living space having interior wall finishes conforming to Section R702.

    Where Item 8 is applicable, design in accordance with accepted engineering practice shall be provided for the floor immediately above the cripple walls or post and beam system and all structural elements and connections from this diaphragm down to and including connections to the foundation and design of the foundation to transfer lateral loads from the framing above.

    Exception: Light-frame construction in which the lowest framed floor is supported directly on concrete or masonry walls over the full length of all sides except the downhill side of the building need not be considered an irregular building under Item 8.

    R301.2.2.7 Height limitations. Wood-framed buildings shall be limited to three stories above grade plane or the limits given in Table R602.10.3(3). Wood-framed buildings in Seismic Design Category D 2 exceeding two stories shall be designed for wind and seismic loads in accordance with accepted engineering practice. Cold-formed steel-framed buildings shall be limited to less than or equal to three stories above grade plane in accordance with AISI S230. Mezzanines as defined in Section R202 that comply with Section R314 shall not be considered as stories. Structural insulated panel buildings shall be limited to two stories above grade plane.

  • CRC § 304.8 Medium relevance — show source text

    Screws shall be No. 10 minimum.|For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
    a. Screws shall be No. 10 minimum.|For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
    a. Screws shall be No. 10 minimum.|For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
    a. Screws shall be No. 10 minimum.|For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
    a. Screws shall be No. 10 minimum.|

    2025 CALIFORNIA RESIDENTIAL CODE 8-39

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    ROOF-CEILING CONSTRUCTION

    R804.3.2.5 Roof rafter bottom flange bracing. The bottom flanges of roof rafters shall be continuously braced, at a maximum spacing of 4 feet (1219 mm) as measured parallel to the roof rafters, with one of the following members:

    1. Minimum 33-mil (0.84 mm) C-shaped member.
    2. Minimum 33-mil (0.84 mm) track section.
    3. Minimum 1 [1] / 2 -inch by 33-mil (38 mm by 0.84 mm) steel strap.

    The bracing element shall be fastened to the bottom flange of each roof rafter with one No. 8 screw and shall be fastened to blocking with two No. 8 screws. Blocking shall be installed between roof rafters in-line with the continuous bracing at a maximum spacing of 12 feet (3658 mm) measured perpendicular to the roof rafters. The ends of continuous bracing shall be fastened to blocking or anchored to a stable building component with two No. 8 screws.

    R804.3.3 Cutting and notching. Flanges and lips of load-bearing, cold-formed steel roof framing members shall not be cut or notched.

    R804.3.4 Headers. Roof-ceiling framing above wall openings shall be supported on headers. The allowable spans for headers in load-bearing walls shall not exceed the values set forth in Section R603.6 and Tables R603.6(1) through R603.6(6).

    R804.3.5 Framing of openings in roofs and ceilings. Openings in roofs and ceilings shall be framed with header and trimmer joists. Header joist spans shall not exceed 4 feet (1219 mm) in length. Header and trimmer joists shall be fabricated from joist and track members having a minimum size and thickness equivalent to the adjacent ceiling joists or roof rafters and shall be installed in accordance with Figures R804.3.5(1) and R804.3.5(2). Each header joist shall be connected to trimmer joists with not less than four 2-inch by 2-inch (51 by 51 mm) clip angles. Each clip angle shall be fastened to both the header and trimmer joists with four No. 8 screws, evenly spaced, through each leg of the clip angle. The steel thickness of the clip angles shall be not less than that of the ceiling joist or roof rafter.

  • CRC § 25.4 Medium relevance — show source text

    8 screws| |For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s, 1 foot = 304.8 mm.
    a. Anchor bolts are to be located not more than 12 inches from corners or the termination of bottom tracks such as at door openings or corners. Bolts extend not less than 15
    inches into masonry or 7 inches into concrete. Anchor bolts connecting cold-formed steel framing to the foundation structure are to be installed so that the distance from the
    center of the bolt hole to the edge of the connected member is not less than one and one-half bolt diameters.
    b. All screw sizes shown are minimum.|For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s, 1 foot = 304.8 mm.
    a. Anchor bolts are to be located not more than 12 inches from corners or the termination of bottom tracks such as at door openings or corners. Bolts extend not less than 15
    inches into masonry or 7 inches into concrete. Anchor bolts connecting cold-formed steel framing to the foundation structure are to be installed so that the distance from the
    center of the bolt hole to the edge of the connected member is not less than one and one-half bolt diameters.
    b. All screw sizes shown are minimum.|For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s, 1 foot = 304.8 mm.
    a. Anchor bolts are to be located not more than 12 inches from corners or the termination of bottom tracks such as at door openings or corners. Bolts extend not less than 15
    inches into masonry or 7 inches into concrete. Anchor bolts connecting cold-formed steel framing to the foundation structure are to be installed so that the distance from the
    center of the bolt hole to the edge of the connected member is not less than one and one-half bolt diameters.
    b. All screw sizes shown are minimum.|

    2025 CALIFORNIA RESIDENTIAL CODE 5-15

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FLOORS

    TABLE R505.3.1(2)—FLOOR FASTENING SCHEDULEa Col2 Col3
    ** DESCRIPTION OF BUILDING ELEMENTS**
    ** NUMBER AND SIZE OF FASTENERS** ** SPACING OF FASTENERS**
    Floor joist to track of an interior load-bearing wall in
    accordance with Figures R505.3.1(7) and R505.3.1(8)
    2-No. 8 screws Each joist
    Floor joist to track at end of joist 2-No. 8 screws One per flange or two per bearing stiffener
    Subfloor to floor joists No. 8 screws 6 in. o.c. on edges and 12 in. o.c. at intermediate
    supports
    For SI: 1 inch = 25.4 mm.
    a. All screw sizes shown are minimum.
    For SI: 1 inch = 25.4 mm.
    a. All screw sizes shown are minimum.
    For SI: 1 inch = 25.4 mm.
    a. All screw sizes shown are minimum.

    FIGURE R505.3.1(1)—FLOOR-TO-EXTERIOR LOAD-BEARING WALL STUD CONNECTION

    RIM TRACK

    WEB STIFFENER

    SHEATHING

    TRACK

  • CRC § 4-6 Medium relevance — show source text

    R403 Footings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6

    R404 Foundation and Retaining Walls . . . . . . . . . . . . . . . . 4-24

    R405 Foundation Drainage . . . . . . . . . . . . . . . . . . . . . . . . . . 4-42

    R406 Foundation Waterproofing and Dampproofing . . . 4-43

    R407 Columns. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44

    R408 Under-Floor Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-44

    CHAPTER 5 FLOORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    R501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    R502 Wood Floor Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    R503 Floor Sheathing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12

    R504 Pressure Preservative-Treated Wood

    Floors (On Ground) . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14

    R505 Cold-Formed Steel Floor Framing . . . . . . . . . . . . . . . 5-14

    R506 Concrete Floors (On Ground) . . . . . . . . . . . . . . . . . . . 5-26

    R507 Exterior Decks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26

    CHAPTER 6 WALL CONSTRUCTION. . . . . . . . . . . . . . . . . . . 6-3

    R601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

    R602 Wood Wall Framing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

    R603 Cold-Formed Steel Wall Framing. . . . . . . . . . . . . . . . 6-53

    R604 Wood Structural Panels . . . . . . . . . . . . . . . . . . . . . . . . 6-93

    R605 Particleboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-93

    R606 General Masonry Construction. . . . . . . . . . . . . . . . . . 6-93

Frequently asked questions

Where are the prescriptive header spans for cold‑formed steel headers?

The CRC prescribes allowable header configurations and spans in § R603.6 and accompanying Tables R603.6(1)–(6); consult that section and its figures for box, back‑to‑back and L‑shaped header details .

Can I notch CFS stud flanges or cut web holes freely?

No. Flanges and lips of cold‑formed steel studs and headers shall not be cut or notched, and web holes must comply with AISI requirements or be reinforced/ patched per the provisions in § R603.2.6 and related AISI references .

When do the masonry seismic rules apply to openings and wall lengths?

Seismic detailing and minimum solid‑wall length rules for masonry walls are required in Seismic Design Categories D0, D1 and D2 (with specific townhouse requirements in C) under § R606.12; use Table R606.12.2.1 and the figures in that section to determine minimum uninterrupted wall lengths and reinforcement around openings .

More in California Residential Code