1705.3 Concrete Construction.
Sunnyvale Municipal Code · 2026-09 edition · updated 2026-09-27 · Sunnyvale
Special inspections and tests of concrete constructions shall be
performed in accordance with this section and Table 1705.3.
Exceptions: Special inspections and tests shall not be required for: [OSHPD 1R, 2 & 5]Exceptions 1 through 4 are not permitted by OSHPD.
- Isolated spread concrete footings of buildings three stories or less above grade plane that
are fully supported on earth or rock where the structural design of the footing is based on specified compressive strength f'c, not more than 2,500 pounds per square inch (psi) (17.2 MPa), regardless of the compressive strength of the construction documents or used in the footing construction.
- Continuous concrete footing supporting walls of buildings three stories or less above grade plane that are fully supported on earth or rock where:
Get a plain-English answer with a citation back to this text.