Skip to content

Chapter 14.04 — BUILDING CODE AND RELATED CODES

Pasadena Municipal Code · 2026-09 edition · updated 2026-09-27 · Pasadena

14.04.010 - Adoption and filing.

California Building Codes adopted. California Code of Regulation Title 24 Parts 1 through 12 consisting of the: 2025 California Administrative Code; 2025 California Building Code with Appendix Chapters G, H, I, J, N, P, and Q; 2025 California Residential Code with Appendix Chapters BB, BF, BG, CH, CI, and CJ; 2025 California Electrical Code with Annexes A, C, I; 2025 California Mechanical Code with Appendix Chapters B, C, F, G, H; 2025 California Plumbing Code with Appendix Chapters A, D, G, H, I, J, M, R; 2025 California Energy Code; 2025 California Wildland-Urban Interface Code, 2025 California Historical Building Code; 2025 California Fire Code including Chapters 1,3, Section 503 of Chapter 5, Sections 1101 and 1104 of Chapter 11, Appendix Chapter 4 and Appendices B, C, D, E, F, G, H, I, K, M, N, O, and P; 2025 California Existing Building Code; 2025 California Green Building Standards Code; 2025 California Referenced Standards Code, and amendments from specific State of California State Agencies. One copy of all of the above publications shall be on file for public inspection and is hereby adopted with the same force and effect as though set out herein in full.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.015 - Section 1.1.1 of the California Building Code is amended to read as follows.

1.1.1 Title.

These regulations shall be known as the California Building Code, may be cited as such and will be referred to

herein as "this code." The California Building Code is Part 2 of thirteen parts of the official compilation and publication of the adoption, amendment and repeal of building regulations to the California Code of Regulations, Title 24, also referred to as the California Building Standards Code. This part incorporates by adoption the 2024 International Building Code of the International Code Council with necessary California amendments.

For the City of Pasadena, these regulations shall be known as the Pasadena Building Code. The provisions contained in the California Building Code of the (compiled) California Building Standards Code as defined in section 18910, Health and Safety Code, may be cited as such and are referred to hereafter as "these regulations" or "these building standards" or "this code". These regulations shall also be collectively known as the "California Building Code" as amended by the Pasadena Municipal Code.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.020 - Section 105.1.3 of Chapter 1 Division II of the 2025 California Building…

[A]105.1.3 Zoning Permits

A zoning permit may be required for items exempted from building permit requirements under Chapter 1 Division II Section 105.2. Exempted work shall not violate any provisions of this Code, Federal, State, Local laws, or regulations.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.025 - Section 903.2 of the 2025 California Building Code titled "Where required"…

903.2 Where required.

All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.

Exception: The following types of construction may be exempt from this section when approved by the fire code official.

Detached private garages, utility sheds, and similar structures 500 square feet or less, accessory to a R-3 occupancy, provided no portion of the structure is located more than 150 feet (45,720 mm) from an approved fire department access road.

Detached Carports, detached gazebos, pergolas, and similar shade structures open on all sides constructed of non- combustible material 500 square feet or less, accessory to a R-3 occupancy.

Other similar structures as deemed appropriate by the fire code official.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.030 - Section 903.1 of the 2025 California Building Code is amended by adding Section 903.1.2 titled "Partial automatic fire sprinkler system prohibited" to read as follows.

903.1.2 Partial automatic fire sprinkler system prohibited.

Whenever an automatic fire sprinkler system is installed for any portion of any building or structure, an automatic fire sprinkler system shall be installed for the entire building or structure.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.035 - Section 903.2.18 of the 2025 California Building Code titled "Group U…

Group R-3 occupancies" is amended to read as follows.

903.2.18 Group U detached and attached private garages, carports, and similar structures accessory to Group R-3 occupancies.

Carports with habitable space above and attached garages, accessory to Group R-3 occupancies, shall be protected by residential fire sprinklers in accordance with this section. When an automatic fire sprinkler system is required in accordance with sections 903.1.2 and 903.2, carports without habitable space above, detached garages, and similar attached and detached structures, accessory to R-3 occupancies, shall be protected by residential fire sprinklers in accordance with this section. Residential fire sprinklers shall be connected to, and installed in accordance with, an automatic residential fire sprinkler system that complies with Section R309 of the California Residential Code or with NFPA 13D. Fire sprinklers shall be residential sprinklers or quick-response sprinklers, designed to provide a minimum density of 0.05 gpm/ft2 (2.04 mm/min) over the area of the garage, carport, and/or similar structure, but not to exceed two sprinklers for hydraulic calculation purposes. Garage doors shall not be considered obstructions with respect to sprinkler placement.

(Ord. No. 7461, § 5, 11-10-2025)

14.05.040 - Section 903.3.5 of the 2025 California Building Code titled "Water…

Subsection 903.3.5.1 adopted as published.

903.3.5 Water supplies.

Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section 903.3.1. The potable water supply shall be protected against backflow in accordance with Health and Safety Code 13114.7. For connections to public waterworks systems, the water supply test used for design of fire protection systems shall be adjusted to account for seasonal and daily pressure fluctuations based on information from the water supply authority and as approved by the fire code official. Hydraulic calculations shall include a 10% safety margin.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.045 - Section 903.3.5.2 of the 2025 California Building Code titled "Residential…

read as follows.

903.3.5.2 Residential combination services.

A single combination water supply shall not be allowed for NFPA 13R systems.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.050 - Section 1505.1 of the 2025 California Building Code is amended to read as follows.

[BF] 1505.1 General.

Fire classification of roof assemblies shall be in accordance with Section 1505. The minimum fire classification of roof assemblies installed on buildings shall comply with Table 1505.1 based on type of construction of the building. Class A and B roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E108 or UL 790. In addition, fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with Table 1505.1 based on the type of construction of the building. All roof assemblies and roof coverings shall be of not less than Class B. No wood roof covering material shall be installed on any structure located in the very high, high and moderate fire hazard severity zones as identified by the Pasadena Fire Department.

Exception 1: Skylights and sloped glazing that comply with Chapter 24 or Section 2610. Installation of skylights of plastic material shall meet the requirements of the very high and high fire hazard severity zones.

Exception 2: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structures.

[BF] TABLE 1505.1—MINIMUM ROOF ASSEMBLY CLASSIFICATION FOR TYPES OF CONSTRUCTION a,

IA IB IIA IIB IIIA IIIB IV VA VB

B B B B c B B c B B B c

For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m 2 .

a.

Unless otherwise required in accordance with the California Wildland-Urban Interface Code or due to the location of the building within a fire district in accordance with Appendix D.

c.

Buildings that are not more than two stories above grade plane and having not more than 6,000 square feet of projected roof area and where there is a minimum 10-foot fire-separation distance from the leading edge of the roof to a lot line on all sides of the building, except for street fronts or public ways and is not located in a fire hazard severity zones, shall be permitted to have roofs of No. 1 cedar or redwood shakes and No. 1 shingles constructed in accordance with Section 1505.7.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.055 - Section 1505.6 of the 2025 Edition of the California Building Code is amended to read as follows.

[BF] 1505.6 Fire-retardant-treated wood shingles and shakes.

Fire-retardant-treated wood shingles and wood shakes shall not be installed in the very high, high and moderate fire hazard severity zones. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 for use on Class A, B roofs.

Fire-retardant-treated wood shakes and shingles shall comply with ICC-ES EG107 and with the weathering requirements contained in Health and Safety Code Section 13132.7(j). Each bundle shall bear labels from an ICC accredited quality control agency identifying their roof-covering classification and indicating their compliance with ICC-ES EGI07 and with the weathering requirements contained in Health and Safety Code Section 13132.7(j).

Health and Safety Code Section 13132.7(j). No wood roof covering materials shall be sold or applied in this state unless both of the following conditions are met:

(1)

The materials have been approved and listed by the State Fire Marshal as complying with the requirements of this section.

(2)

The materials have passed at least five years of the 10-year natural weathering test. The 10-year natural weathering test required by this subdivision shall be conducted in accordance with standard 15-2 of the 1994 Edition of the Uniform Building Code at a testing facility recognized by the State Fire Marshal.

Exception: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire-resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structures.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.060 - Section 1507 of the 2025 California Building Code is amended by adding Section 1507.1.3 to read as follows.

1507.1.3 Roof Sheathing.

When finish roofing material is removed to the existing open space sheathing, a minimum of 3/8-inch thick plywood sheathing shall be installed. The new sheathing shall comply with the requirements of the California Building Code. The sheathing shall be installed such that the edges align over rafters and individual spaced sheathing boards. The sheathing shall be attached to the existing spaced sheathing with 6d common nails at 6 inches (147mm) on center at supported edges and 6d common nails at 12 inches (294mm) on center at intermediate supports.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.065 - Sections 1613.8 and 1613.8.1 are added to Chapter 16 of the 2025 Edition of…

14.04.070 - Section 1613.8.2 is added to Chapter 16 of the 2025 Edition of the…

1613.8.2 Wood diaphragms. Modify ASCE 7 Section 12.11.2.2.3 as follows:

14.04.075 - Section 1613.8.3 is added to Chapter 16 of the 2025 Edition of the…

1613.8.3 Structural separation. Modify ASCE 7 Section 12.12.3 Equation 12.12-1 as follows:

Where δDE1 and δDE2 are the Design Earthquake Displacements of the adjacent structures at their adjacent edges. Where a structure adjoins a property line not common to a public way, the structure shall be set back from the property line by at least the displacement δDE of that structure.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.080 - Section 1613.9 is added to Chapter 16 of the 2025 Edition of the California…

14.04.085 - Section 1613.10 is added to Chapter 16 of the 2025 Edition of the…

14.04.090 - Section 1704.6 of the 2025 Edition of the California Building Code is amended to read as follows.

14.04.095 - Section 1704.6.1 of the 2025 Edition of the California Building Code is…

1704.6.1 Structural observations for structures.

Structural observations shall be provided for those structures where one or more of the following conditions exist:

The structure is classified as Risk Category III or IV.

The structure is a high-rise building.

The structure is assigned to Seismic Design Category E, and is greater than two stories above grade plane.

Such observation is required by the registered design professional responsible for the structural design.

Such observation is specifically required by the building official.

A lateral design is required for the structure or portion thereof.

Exception: One-story wood framed Group R-3 and Group U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10% sloped), assigned to Seismic Design Category D.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.100 - Section 1705.3 of the 2025 Edition of the California Building Code is amended to read as follows.

14.04.105 - Section 1807.1.4 of the 2025 Edition of the California Building Code is…

1807.1.4 Permanent wood foundation systems

[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Permanent wood foundation systems shall be designed and installed in accordance with AWC PWF. Lumber and plywood shall be preservative treated in accordance with AWPA U1 (Commodity Specification A, Special Requirement 4.2) and shall be identified in accordance with Section 2303.1.9.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.110 - Section 1807.1.6 of the 2025 Edition of the California Building Code is…

adopted as published.

1807.1.6 Prescriptive design of concrete and masonry foundation walls.

[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.115 - Section 1807.2 of the 2025 Edition of the California Building Code is…

14.04.120 - Section 1807.3.1 of the 2025 Edition of the California Building Code is…

1807.3.1 Limitations. The design procedures outlined in this section are subject to the following limitations:

The frictional resistance for structural walls and slabs on silts and clays shall be limited to one-half of the normal force imposed on the soil by the weight of the footing or slab.

Posts embedded in earth shall not be used to provide lateral support for structural or nonstructural materials such as plaster, masonry or concrete unless bracing is provided that develops the limited deflection required.

Wood poles shall be treated in accordance with AWPA U1 for sawn timber posts (Commodity Specification A, Use Category 4B) and for round timber posts (Commodity Specification B, Use Category 4B). Wood poles and posts embedded in direct contact with soil shall not be used for structures assigned to Seismic Design Category D, E or F.

Exception: Wood poles and posts embedded in direct contact with soil may be used to support nonhabitable, nonoccupiable structures such as fences when approved by the building official.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.125 - Section 1809.3 of the 2025 Edition of the California Building Code is amended to read as follows.

14.04.130 - Section 1809.7 and Table 1809.7 of the 2025 Edition of the California…

14.04.135 - Section 1809.12 of the 2025 Edition of the California Building Code is amended to read as follows.

14.04.140 - Section 1810.3.2.4 of the 2025 Edition of the California Building Code is…

1810.3.2.4 Timber.

[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS-20. Timber deep foundation elements shall not be used in structures assigned to Seismic Design Category D, E or F.

1810.3.2.4.1 Preservative treatment.

Timber deep foundation elements used to support permanent structures shall be treated in accordance with this section unless it is established that the tops of the untreated timber elements will be below the lowest ground-water level assumed

to exist during the life of the structure. Preservative and minimum final retention shall be in accordance with AWPA U1 (Commodity Specification E, Use Category 4C) for round timber elements and AWPA U1 (Commodity Specification A, Use Category 4B) for sawn timber elements. Preservative-treated timber elements shall be subject to a quality control program administered by an approved agency. Element cutoffs shall be treated in accordance with AWPA M4.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.145 - Section 1905.6.2 of the 2025 Edition of the California Building Code is…

1905.6.2 Seismic design categories C, D, E, and F.

Structural plain concrete basement, foundation or other walls below the base as defined in ASCE/SEI 7 are permitted in detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls. In dwellings assigned to Seismic Design Category D or E, the height of the wall shall not exceed 8 feet (2438 mm), the thickness shall be not less than 71/2 inches (190 mm), and the wall shall retain not more than 4 feet (1219 mm) of unbalanced fill. Walls shall have reinforcement in accordance with Section 14.6.1 of ACI 318.

Isolated footings of plain concrete supporting pedestals or columns are permitted, provided that the projection of the footing beyond the face of the supported member does not exceed the footing thickness.

Exception: In detached one-and-two-family dwellings three stories or less in height, the projection of the footing beyond the face of the supported member is permitted to exceed the footing thickness.

Plain concrete footings supporting wall are permitted, provided that the footings have not fewer than two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. For footings that exceed 8 inches (203 mm) in thickness, not fewer than one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.

Exceptions:

a.

Where assigned to Seismic Design Category C, detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls are permitted to have plain concrete footings without longitudinal reinforcement.

b.

For foundation systems consisting of a plain concrete footing and a plain concrete stemwall, not fewer than one bar shall be provided at the top of the stemwall and at the bottom of the footing.,

c.

Footings cast monolithically with a slab-on-grade shall have not fewer than one No. 4 bar at the top and bottom of the footing or one No. 5 bar or two No. 4 bars in the middle third of the footing depth.

Structures assigned to Seismic Design Category C, D, E, or F shall not have elements of structural plain concrete except where concrete used for fill with a minimum cement content of two (2) sacks of Portland cement or cementitious material per cubic yard.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.150 - Subsections 1905.8 through 1905.10 are added to Chapter 19 of the 2025…

follows.

1905.8 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.8 and 18.7.5.9 as follows:

18.10.4.7 Walls and portions of walls with P u > 0.35P o shall not be considered to…

strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318

18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor…

than 3 inches (76 mm) or 6 d b in thickness, where d b is the diameter of the largest reinforcement in the topping slab.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.155 - Section 2304.10.2 of the 2025 Edition of the California Building Code is…

2304.10.2 is adopted as published.

2304.10.2 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.2. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.

Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.160 - Section 2304.10.3.1 of the 2025 Edition of the California Building Code is…

2304.10.3.1 Quality of Nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.165 - Section 2304.12.2.8 of the 2025 Edition of the California Building Code is…

2304.12.2.8 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.170 - Section 2305.4 is added to the 2025 Edition of the California Building Code to read as follows.

14.04.175 - Section 2306.2 is added to the 2025 Edition of the California Building Code to read as follows.

14.04.180 - Section 2306.3 is added to the 2025 Edition of the California Building Code to read as follows.

14.04.185 - Section 2307.2 is added to the 2025 Edition of the California Building Code to read as follows.

14.04.190 - Table 2308.10.1 is added to the 2025 Edition of the California Building Code to read as follows.

(Ord. No. 7461, § 5, 11-10-2025)

4.04.195 - Sections 2308.10.5.1 and 2308.10.5.2 and Figures 2308.10.5.1 and 2308.10.5.2…

California Building Code are amended to read as follows.

2308.10.5.1 Alternate braced wall (ABW). An ABW shall be constructed in accordance with this section and Figure 2308.10.5.1. In one-story buildings, each panel shall have a length of not less than 2 feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with 3/8-inch (3.2 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Table 2304.10.2 and blocked at wood structural panel edges. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports. Two anchor bolts installed in accordance with Section 2308.7.1 shall be provided in each panel. Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall have a hold-down device fastened to the foundation, capable of providing an approved uplift

capacity of not less than 1,800 pounds (8006 N). The hold-down device shall be installed in accordance with the manufacturer's recommendations. The ABW shall be supported directly on a foundation or on floor framing supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.

Where the ABW is installed at the first story of two-story buildings, the wood structural panel sheathing shall be provided on both faces, three anchor bolts shall be placed at one-quarter points and tie-down device uplift capacity shall be not less than 3,000 pounds (13 344 N).

2308.10.5.2 Portal frame with hold-downs (PFH). A PFH shall be constructed in accordance with this section and Figure 2308.10.5.2. The adjacent door or window opening shall have a full-length header.

In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8-inch (9.5 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure 2308.10.5.2. For structures assigned to Seismic Design Category D or E. each panel shall be sheathed on one face with 15/32-inch- minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in accordance with Figure 2308.10.5.2. The wood structural panel sheathing shall extend up over the solid sawn or glued-laminated header and shall be nailed in accordance with Figure 2308.10.5.2. A built-up header consisting of at least two 2-inch by 12-inch (51 mm by 305 mm) boards, fastened in accordance with Item 24 of Table 2304.10.2 shall be permitted to be used. A spacer, if used, shall be placed on the side of the built-up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1,000 pounds (4,400 N) shall fasten the header to the inner studs opposite the sheathing. One anchor bolt not less than ⅝ inch (15.9 mm) diameter and installed in accordance with Section 2308.7.1 shall be provided in the center of each sill plate. The studs at each end of the panel shall have a hold-down device fastened to the foundation with an uplift capacity of not less than 3,500 pounds (15 570 N).

Where a panel is located on one side of the opening, the header shall extend between the inside face of the first full-length stud of the panel and the bearing studs at the other end of the opening. A strap with an uplift capacity of not less than 1,000 pounds (4400 N) shall fasten the header to the bearing studs. The bearing studs shall also have a hold-down device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (4400 N). The hold-down devices shall be an embedded strap type, installed in accordance with the manufacturer's recommendations. The PFH panels shall be

supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.

s (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.

Where a PFH is installed at the first story of two-story buildings, each panel shall have a length of not less than 24 inches (610 mm).

(Ord. No. 7461, § 5, 11-10-2025)

14.04.200 - Section 2308.10.8.1 is added to the 2025 Edition of the California Building…

2308.10.8.1 Foundation requirements. Braced wall lines shall be supported by continuous foundations.

Exception: For structures with a maximum plan dimension not more than 50 feet (15 240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C.

For structures in Seismic Design Categories D and E, exterior braced wall panels shall be in the same plane vertically with the foundation or the portion of the structure containing the offset shall be designed in accordance with accepted engineering practice and Section 2308.3.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.205 - Section 2308.10.9 of the 2025 Edition of the California Building Code is…

2308.10.9 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Tables 2308.10.1 or 2304.10.2. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.

Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.

All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight

8d nails per clip minimum). Braced wall panels shall be laterally braced at each top corner and at intervals not to exceed 24 inches (6096 mm) intervals along the top plate of discontinuous vertical framing.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.210 - Section 3103.1.3 of the 2025 Edition of the California Building Code is…

3103.1.3 Permit required.

Temporary structures that cover an area greater than 120 square feet (11.16 m 2 ), including connecting areas or spaces with a common means of egress or entrance that are used or intended to be used for the gathering together of 10 or more persons, shall not be erected, operated or maintained for any purpose without obtaining a permit from the building official.

Temporary tent and membrane structures for special events. A permit is required to operate an air-supported temporary membrane structure, a temporary special event tent having an area in excess of 400 square feet (37 m 2 ). The aggregate area of multiple tents placed side by side without a fire break clearance of not less than 12 feet (3658 mm) shall not exceed 400 square feet (37 m 2 ) total. A minimum clearance of 12 feet (3658 mm) to structures and other tents shall be provided.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.215 - Section 3109.1.1 to the 2025 Edition of the California Building Code is added to read as follows.

In addition to the requirements of Section 3109 in the California Building Code, a swimming pool, pool, spa or any body of water over 18 inches deep shall have an enclosure consisting of a fence, wall, portions of a building or other approved durable material, that isolates all bodies of water from the private building or structure. The enclosure shall be installed around the perimeter of the bodies of water, or at the perimeter of the property.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.220 - Exception 6 of Section 3114.1 to Chapter 31 of the 2025 Edition of the…

read as follow.

Single-unit stand-alone intermodal shipping containers used as temporary storage or construction trailer on active construction sites. Construction support facilities for uses and activities not directly associated with the actual processes of construction, including but not limited to, offices, meeting rooms, plan rooms, other administrative or support functions shall not be exempt from Section 3114.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.225 - Section J103.2 of the 2025 Edition of the California Building Code is amended to read as follows.

An excavation that does not exceed 50 cubic yards (38.3 m 3 ) and complies with (a) or (b) as follows:

(a)

Is less than 2 feet (0.6 m) in depth.

(b)

Does not create a cut slope greater than 5 feet (1.5 m) measured vertically upward from the cut surface to the surface of the natural grade and is not steeper than 2 units horizontal to 1 unit vertical (50 percent slope).

(Ord. No. 7461, § 5, 11-10-2025)

14.04.300 - Section R101.1 of the California Residential Code is amended to read as follows.

R101.1 Title. For the city of Pasadena, these regulations shall be known as the Pasadena Residential Code. The provisions contained in the California Residential Code of the (compiled) California Building Standards Code as defined in section 18910, Health and Safety Code, may be cited as such and are referred to hereafter as 'these regulations' or 'these building standards' or 'this code.' These regulations shall also be collectively known as the 'California Residential Code' as amended by the Pasadena Municipal Code.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.305 - Section R105.1.1 of Chapter 1 Division II of the 2025 California…

[A]R105.1.1 Zoning Permits

A zoning permit may be required for items exempted from building permit requirements under Chapter 1 Division II Section 105.2. Exempted work shall not violate any provisions of this Code, Federal, State, Local laws, or regulations.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.310 - Section R301.1.3.2 of the 2025 Edition of the California Residential Code…

R301.1.3.2 Woodframe structures. The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than two stories and basement in height located in Seismic Design Category A, B or C. Notwithstanding other sections of law; the law establishing these provisions is found in Business and Professions Code Sections 5537 and 6737.1.

The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than one story in height or with a basement located in Seismic Design Category D 0 , D 1 , or D 2 .

(Ord. No. 7461, § 5, 11-10-2025)

14.04.315 - Section R301.1.5 is added to the 2025 California Residential Code to read as follows.

R301.1.5 Seismic design provisions for buildings constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope). The design and construction of new buildings and additions to existing buildings when constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope) shall comply with Section 1613.6 of the California Building Code.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.320 - Items 1, 3, and 5 of Section R301.2.2.6 of the 2025 Edition of the…

read as follows.

Shear wall or braced wall offsets out of plane. Conditions where exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required.

Shear wall or braced wall offsets in plane. Conditions where the end of a braced wall panel occurs over an opening in the wall below.

Floor level offset. Conditions where portions of a floor level are vertically offset.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.325 - Section R301.2.2.11 is added to the 2025 Edition of the California…

R301.2.2.11 Anchorage of mechanical, electrical, or plumbing components and equipment. Mechanical, electrical, or plumbing components and equipment shall be anchored to the structure. Anchorage of the components and equipment shall be designed to resist loads in accordance with the California Building Code and ASCE 7, except where the component is positively attached to the structure and flexible connections are provided between the component and associated ductwork, piping, and conduit; and either

The component weighs 400 lb (1,780 N) or less and has a center of mass located 4 ft (1.25 m) or less above the supporting structure; or

The component weighs 20 lb (89N) or less or, in the case of a distributed system, 5 lb/ft (73 N/m) or less.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.330 - Section R309.1 of the 2025 Edition of the California Residential Code is…

R309.1 Townhouse automatic sprinkler systems.

An automatic sprinkler system shall be installed in townhouses. All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.

Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed.

R309.1.1 Design and installation.

Automatic sprinkler systems for townhouses shall be designed and installed in accordance with Section R309 or NFPA 13D.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.335 - Section R309.2 of the 2025 Edition of the California Residential Code is…

R309.2 One- and two-family dwellings automatic sprinkler systems.

An automatic sprinkler system shall be installed in one- and two-family dwellings. All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.

Exceptions:

An automatic sprinkler system shall not be required for alterations to existing buildings that are not already provided with a sprinkler system.

Whenever additions result in an additional level above or below grade, or a total increase of more than 1000 square feet (92.9 m 2) or more, or an increase of more than fifty percent (50%) of the existing floor area including mezzanines and additional stories, whichever is less, regardless of ownership. Additions shall be cumulative with each application for a building permit from January 1, 2008 to present day. R-3 occupancies shall not be required to comply with this section solely due to the addition of an additional level, unless the criteria for an increase of existing floor area is also exceeded or if the addition exceeds a combined total floor area of 3,600 square feet and fire flow requirements are not met.

Accessory Dwelling Unit, provided that all of the following are met:

2.1.

The unit meets the definition of an Accessory Dwelling Unit as defined in the Government Code Section 65852.2.

2.2.

The existing primary residence does not have automatic fire sprinklers.

2.3.

The accessory detached dwelling unit does not exceed 1,200 square feet in size.

2.4.

The unit is on the same lot as the primary residence.

2.5.

All portions of exterior walls are within 150 feet from fire access road as measured by an approved route approved by the Fire Official.

2.6.

All portions of exterior walls within 400 feet of a fire hydrant as measured by an approved route approved by the Fire Official.

Detached private garages, utility sheds, and similar structures 500 square feet or less, accessory to a R-3 occupancy, provided no portion of the structure is located more than 150 feet (45,720 mm) from an approved fire department access road.

Detached Carports, detached gazebos, pergolas, and similar shade structures open on all sides constructed of non- combustible material 500 square feet or less, accessory to a R-3 occupancy.

Other similar structures as deemed appropriate by the fire code official.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.340 - Section R309.3.1 of the 2025 Edition of the California Residential Code is…

subsections are to be adopted as published by the State.

R309.3.1 General.

The design and installation of automatic sprinkler systems shall be in accordance with NFPA 13D or Section R309.3, which shall be considered to be equivalent to NFPA 13D. Partial automatic sprinkler systems shall not be permitted to be installed only in buildings not required to be equipped with an automatic sprinkler system. Section R309.3 shall apply to standalone and multipurpose wet-pipe sprinkler systems that do not include the use of antifreeze. A multipurpose automatic sprinkler system shall provide domestic water to both fire sprinklers and plumbing fixtures. A stand-alone automatic sprinkler system shall be separate and independent from the water distribution system.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.345 - Section R309.3.5 of the 2025 Edition of the California Residential Code is…

subsections are to be adopted as published by the State.

R309.3.5 Water supply.

The water supply shall provide not less than the required design flow rate for sprinklers in accordance with Section R309.3.4.2 at a pressure not less than that used to comply with Section R309.3.6. Where a water supply serves both domestic and fire sprinkler systems, 5 gpm (19 L/min) shall be added to the sprinkler system demand at the point where the systems are connected, to determine the size of common piping and the size of the total water supply requirements where no provision is made to prevent flow into the domestic water system upon operation of a sprinkler. For multipurpose piping systems, the 5 gpm (19 L/min) demand shall be added at the domestic connection nearest the design area. This demand may be split between two domestic connections at 2.5 gpm (10 L/min) each. Hydraulic calculations shall include a 10% safety margin.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.350 - Section R401.1 of the 2025 Edition of the California Residential Code is…

R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for buildings. In addition to the provisions of this chapter, the design and construction of foundations in flood hazard areas as established by Table R301.2 shall meet the provisions of Section R306. Wood foundations shall be designed and installed in accordance with AWC PWF.

Exception: The provisions of this chapter shall be permitted to be used for wood foundations only in the following situations:

In buildings that have no more than two floors and a roof.

When interior basement and foundation walls are constructed at intervals not exceeding 50 feet (15 240 mm).

Wood foundations in Seismic Design Category D 0 , D 1 , or D 2 shall not be permitted.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.355 - Sections R403.1.3.6, R403.1.5 of the 2025 Edition of the California…

follows.

R403.1.3.6 Isolated concrete footings. In detached one- and two-family dwellings located in Seismic Design Category A, B, or C, that are three stories or less in height, and constructed with stud bearing walls, isolated plain concrete footings supporting columns or pedestals are permitted.

R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall not have a slope exceeding 1 unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footings or where the slope of the bottom surface of the footings will exceed one unit vertical in 10 units horizontal (10-percent slope).

For structures assigned to Seismic Design Categories D 0 , D 1 , or D 2 , stepped footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure R403.1.5.

FIGURE R403.1.5 STEPPED FOOTING

(Ord. No. 7461, § 5, 11-10-2025)

14.04.360 - Section R404.2 of the 2025 Edition of the California Residential Code is…

R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R403.1(2) and R403.1(3). Wood foundation walls shall not be used for structures located in Seismic Design Category D 0 , D 1 , or D 2 .

(Ord. No. 7461, § 5, 11-10-2025)

14.04.365 - Section R501.2 of the 2025 Edition of the California Residential Code is…

R501.2 Requirements. Floor construction shall be capable of accommodating all loads in accordance with Section R301 and of transmitting the resulting loads to the supporting structural elements. Mechanical or plumbing fixtures and equipment shall be attached or anchored to the structure in accordance with Section R301.2.2.11.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.370 - Lines 20, 21, 24, and 34-37 of Table R602.3(1) of the 2025 Edition of the…

amended to read as follows.

TABLE R602.3(1)—continued FASTENING SCHEDULE

ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER a, b, c SPACING AND LOCATION

                                                   3-8d box (2½" × 0.113"); or

20 k 1" × 6" sheathing to each bearing 2-8d common (2½" × 0.131"); or 2-10d box (3" × 0.128"); or Face nail 2 staples, 1" crown, 16 ga., 1¾" long

                                                   3-8d box (2½" × 0.113"); or
                                                   3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or
                                                3 staples, 1" crown, 16 ga., 1¾" long

21 k 1" × 8" and wider sheathing to each bearing Wider than 1" × 8" Face nail 4-8d box (2½" × 0.113"); or 3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or 4 staples, 1" crown, 16 ga., 1¾" long

Floor

                                                   3-8d box (2½" × 0.113"); or

24 k 1" × 6" subfloor or less to each joist 2-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or Face nail 2 staples, 1" crown, 16 ga., 1¾" long

Other wall sheathing g

                                            1½" x 0.120"galvanized roofing nail, 7/16 " head diameter,
                                                                                                   3               6 34 k       1/2" structural cellulosic fiberboard sheathing
                                                            or 1¼" long 16 ga. staple with 7/16 " or 1" crown

                                            1¾" x 0.120" galvanized roofing nail, 7/16 " head diameter,

35 k 25/32" structural cellulosic fiberboard sheathing 3 6 or 1 ¼"long 16 ga. Staple with 7/16 " or 1" crown

                                            1½" x 0.120" galvanized roofing nail, 7/16 " head diameter,
                                                            or 1¼" long, 16 ga.;
                                                                                                   7               7 36 k       1/2" gypsum sheathing d
                                                            staple galvanized, 1½" long; 7/16 " or 1" crown or 1¼"
                                                       screws, Type W or S

1¾" galvanized roofing nail, 7/16 " head diameter, or 1¼" long, 16 ga.; 37 k ⅝" gypsum sheathing d 7 7 staple galvanized, 1½" long; 7/16 " or 1" crown or 1¼" screws, Type W or S

k. Use of staples in roof, floor, and braced wall panels shall be prohibited in Seismic Design Category D 0 , D 1 , or D 2 .

(Ord. No. 7461, § 5, 11-10-2025)

14.04.375 - Footnote "b" of Table R602.3(2) of the 2025 Edition of the California…

follows.

b.

Staples shall have a minimum crown width of 7/16-inch on diameter except as noted.

Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category D 0 , D 1 , or D 2 .

(Ord. No. 7461, § 5, 11-10-2025)

14.04.380 - Section R602.3.2, Exception and Table R602.3.2 of the 2025 Edition of the…

amended to read as follows.

Exception: In other than Seismic Design Category D 0 , D 1 or D 2 , a single top plate used as an alternative to a double top plate shall comply with the following:

The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2.

The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm).

Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.385 - Section R602.10.2.3 of the 2025 Edition of the California Residential Code…

R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4877 mm) or less shall have not less than two braced wall panels of any length or one braced wall panel equal to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet (4877 mm) shall have not less than two braced wall panels.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.390 - Table R602.10.3(3) of the 2025 Edition of the California Residential Code…

a.

Linear interpolation shall be permitted.

b.

Interpolation of bracing length between the Sds values associated with the seismic design categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.2 of the California Building Code.

c.

Where the braced wall line length is greater than 50 feet, braced wall lines shall be permitted to be divided into shorter segments having lengths of 50 feet or less, and the amount of bracing within each segment shall be in accordance with this table.

d.

Method LIB shall have gypsum board fastened to not less than one side with nails or screws in accordance with Table R602.3(1) for exterior sheathing or Table R702.3.5 for interior gypsum board. Spacing of fasteners at panel edges shall not exceed 8 inches.

e.

Methods PFG and CS-SFB do not apply in Seismic Design Categories D0, D1 and D2.

f.

Methods PFH, PFG and ABW are only permitted on a single story or a first of two stories.

g.

Where more than one bracing method is used, mixing methods shall be in accordance with Section R602.10.4.1.

h.

One- and two-family dwellings in Seismic Design Category D 2 exceeding two stories shall be designed in accordance with accepted engineering practice.

i.

Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D0, D1 and D2. Methods DWB, SFB, PBS, HPS, and CS-SFB are not permitted in D0, D1 and D2.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.395 - Table R602.10.4 of the 2025 Edition of the California Residential Code is…

a.

Adhesive attachment of wall sheathing, including Method GB, shall not be permitted in Seismic Design Categories C, D 0 , D 1 and D 2 .

b.

Applies to panels next to garage door opening where supporting gable end wall or roof load only. Shall only be used on one wall of the garage. In Seismic Design Categories D 0 , D 1 and D 2 , roof covering dead load shall not exceed 3 psf.

c.

Garage openings adjacent to a Method CS-G panel shall be provided with a header in accordance with Table R602.7(1). A full-height clear opening shall not be permitted adjacent to a Method CS-G panel.

d.

Method CS-SFB does not apply in Seismic Design Categories D 0 , D 1 and D 2 .

e.

Method applies to detached one- and two-family dwellings in Seismic Design Categories D 0 through D 2 only.

f.

Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D 0 , D 1 and D 2 . Methods LIB, DWB, SFB, PBS, HPS, and PFG are not permitted in SDC D 0 , D 1 and D 2 .

g.

Use of stapes in braced wall panels shall be prohibited in SDC D 0 , D 1 and D 2 .

(Ord. No. 7461, § 5, 11-10-2025)

14.04.400 - Table R602.10.5 of the 2025 Edition of the California Residential Code is…

TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s.

NP = Not Permitted.

a.

Linear interpolation shall be permitted.

b.

Use the actual length where it is greater than or equal to the minimum length. The actual length of Methods CS-G, CS-WSP, CS-SFB, PFH, PFG and CS-PF is the length of the full-height sheathed section.

c.

Maximum header height for PFH is 10 feet in accordance with Figure R602.10.6.2, but wall height shall be permitted to be increased to 12 feet with pony wall.

d.

Maximum header height for PFG is 10 feet in accordance with Figure R602.10.6.3, but wall height shall be permitted to be increased to 12 feet with pony wall.

e.

Maximum header height for CS-PF is 10 feet in accordance with Figure R602.10.6.4, but wall height shall be permitted to be increased to 12 feet with pony wall.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.405 - Figure R602.10.6.1 of the 2025 Edition of the California Residential Code…

14.04.410 - Figure R602.10.6.2 of the 2025 Edition of the California Residential Code…

(Ord. No. 7461, § 5, 11-10-2025)

14.04.415 - Figure R602.10.6.4 of the 2025 Edition of the California Residential Code…

14.04.420 - Section R606.12.2.2.3 of the 2025 Edition of the California Residential…

R606.12.2.2.3 Reinforcement requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(2) and in accordance with the following:

Horizontal reinforcement. Horizontal joint reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements.

Vertical reinforcement. Vertical reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Vertical reinforcement shall be within 8 inches (406 mm) of the ends of masonry walls.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.425 - Section R803.2.4 is added to Chapter 8 of the 2025 Edition of the…

R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.430 - Section R902.1.1.1 is added to the 2025 Edition of the California…

All roofing material in the very-high and moderate fire hazard severity zone must be Class A. No wood roof covering material shall be installed on any structure located in the very high, high and moderate fire hazard severity zones as identified by the Pasadena Fire Department. All other roof covering materials in other zones shall be Class A or B.

Exception: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire-resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structure.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.435 - Section R1001.3.1 of the 2025 Edition of the California Residential Code is…

R1001.3.1 Vertical reinforcing. For chimneys up to 40 inches (1016 mm) wide, four No. 4 continuous vertical bars adequately anchored into the concrete foundation shall be placed between wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance with Section R606. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches (1016 mm) in width or fraction thereof.

(Ord. No. 7461, § 5, 11-10-2025)

14.04.440 - Section AX100.1 is added to the 2025 Edition of the California Residential…

In addition to the requirements of Appendix AX, the Swimming Pool Safety Act, of the 2025 California Residential Code, a swimming pool, pool, spa or any body of water over 18 inches deep shall have an enclosure consisting of a fence, wall, portions of a building or other approved durable material, that isolates all bodies of water from the public right of way, private single family dwelling, and Accessory Dwelling Unit. The enclosure shall be installed around the perimeter of the bodies of water, or at the perimeter of the property.

(Ord. No. 7461, § 5, 11-10-2025)

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — Pasadena Municipal Code
Pasadena Municipal Code
  1. § 2.04
  2. Article I — NAME AND BOUNDARIES
  3. Article II — SUCCESSION
  4. Article III — POWERS OF THE CITY
  5. Article IV — THE CITY COUNCIL
  6. Article V — LEGISLATION
  7. Article VI — THE CITY MANAGER
  8. Article VII — BOARD OF EDUCATION
  9. Article VIII — THE PERSONNEL SYSTEM
  10. Article IX — FISCAL ADMINISTRATION
  11. Article X — CONTRACTS, PURCHASES AND CLAIMS
  12. Article XI — FRANCHISES
  13. Article XII — ELECTIONS
  14. Article XIII — INITIATIVE, REFERENDUM AND RECALL
  15. Article XIV — WATER AND POWER UTILITY OPERATIONS
  16. Article XV — THE FIRE AND POLICE RETIREMENT SYSTEM
  17. Article XVI — PARK PRESERVATION
  18. Article XVII — TAXPAYER PROTECTION
  19. Article XVIII — THE PASADENA FAIR AND EQUITABLE HOUSING CHARTE…
  20. Title 1 — GENERAL PROVISIONS
  21. Title 1 — FOOTNOTES
  22. Chapter 2.05 — CITY COUNCIL
  23. Chapter 2.10 — CITY COUNCIL VACANCY APPOINTMENT PROCESS
  24. Chapter 2.20 — INDUSTRIAL DEVELOPMENT AUTHORITY
  25. Chapter 2.25 — PARKING AUTHORITY
  26. Chapter 2.28 — SURPLUS PROPERTY AUTHORITY
  27. Chapter 2.30 — CITY ATTORNEY'S DEPARTMENT
  28. Chapter 2.35 — CITY CLERK'S DEPARTMENT
  29. Chapter 2.40 — CITY MANAGER'S DEPARTMENT
  30. Chapter 2.45 — ADVISORY BODIES GENERALLY
  31. Chapter 2.47 — ARTS AND CULTURE COMMISSION
  32. Chapter 2.48 — ACCESSIBILITY AND DISABILITY COMMISSION
  33. Chapter 2.55 — CODE ENFORCEMENT COMMISSION
  34. Chapter 2.60 — COMMUNITY POLICE OVERSIGHT COMMISSION
  35. Chapter 2.65 — COMMISSION ON THE STATUS OF WOMEN
  36. Chapter 2.70 — COMMUNITY DEVELOPMENT COMMITTEE
  37. Chapter 2.75 — HISTORIC PRESERVATION COMMISSION
  38. Chapter 2.80 — DESIGN COMMISSION
  39. Chapter 2.85 — HUMAN RELATIONS COMMISSION
  40. Chapter 2.86 — HUMAN SERVICES COMMISSION
  41. Chapter 2.90 — LIBRARY COMMISSION
  42. Chapter 2.95 — NORTHWEST COMMISSION
  43. Chapter 2.98 — PARKING METER ZONES ADVISORY COMMISSIONS
  44. Chapter 2.100 — RECREATION AND PARKS COMMISSION
  45. Chapter 2.105 — PLANNING COMMISSION
  46. Chapter 2.110 — RELOCATION APPEALS BOARD
  47. Chapter 2.120 — SENIOR COMMISSION
  48. Chapter 2.130 — SOUTH LAKE AVENUE PARKING PLACE COMMISSION
  49. Chapter 2.135 — TRANSPORTATION ADVISORY COMMISSION
  50. Chapter 2.140 — ENVIRONMENTAL ADVISORY COMMISSION
  51. Chapter 2.150 — HAHAMONGNA WATERSHED PARK ADVISORY COMMITTEE
  52. Chapter 2.155 — PASADENA COMMUNITY ACCESS CORPORATION BOARD
  53. Chapter 2.165 — PASADENA CENTER OPERATING COMPANY BOARD
  54. Chapter 2.175 — THE ROSE BOWL OPERATING COMPANY
  55. Chapter 2.250 — RETIREMENT SYSTEM
  56. Chapter 2.255 — AGENCIES AND DEPARTMENTS GENERALLY
  57. Chapter 2.265 — PARKS, RECREATION, AND COMMUNITY SERVICES DEPA…
  58. Chapter 2.266 — PUBLIC HEALTH DEPARTMENT
  59. Chapter 2.267 — LIBRARIES AND INFORMATION SERVICES DEPARTMENT
  60. Chapter 2.268 — HOUSING DEPARTMENT
  61. Chapter 2.270 — PLANNING AND COMMUNITY DEVELOPMENT DEPARTMENT
  62. Chapter 2.275 — FINANCE DEPARTMENT
  63. Chapter 2.280 — FIRE DEPARTMENT
  64. Chapter 2.285 — HUMAN RESOURCES
  65. Chapter 2.290 — INFORMATION TECHNOLOGY DEPARTMENT
  66. Chapter 2.295 — POLICE DEPARTMENT
  67. Chapter 2.300 — PUBLIC WORKS DEPARTMENT
  68. Chapter 2.302 — RENT STABILIZATION DEPARTMENT
  69. Chapter 2.303 — TRANSPORTATION DEPARTMENT
  70. Chapter 2.305 — WATER AND POWER DEPARTMENT
  71. Chapter 2.350 — ACCEPTANCE OF SURETIES
  72. Chapter 2.355 — ADMINISTRATIVE RESOLUTION OF CODE VIOLATIONS
  73. Chapter 2.360 — EQUAL OPPORTUNITY IN CITY EMPLOYMENT
  74. Chapter 2.365 — CLAIMS BY AND AGAINST THE CITY
  75. Chapter 2.370 — DISASTER EMERGENCY SERVICES COUNCIL
  76. Chapter 2.375 — EMERGENCY AUXILIARY FORCES
  77. Chapter 2.380 — HOUSING MEDIATION CONTRACTOR
  78. Chapter 2.385 — PERSONS AUTHORIZED TO ARREST PURSUANT TO PENAL…
  79. Chapter 2.390 — RECORD AND DOCUMENT FEES
  80. Chapter 2.395 — UNCLAIMED PERSONAL PROPERTY
  81. Chapter 2.400 — USE AND ACCESS OF CRIMINAL HISTORY INFORMATION
  82. Chapter 3.04 — PASADENA CENTER
  83. Chapter 3.12 — TOURNAMENT OF ROSES—GRANDSTANDS
  84. Chapter 3.16 — TOURNAMENT OF ROSES—PROGRAMS
  85. Chapter 3.20 — PARADE PERMITS
  86. Chapter 3.22 — INTERFERENCE WITH SPECIAL EVENT
  87. Chapter 3.23 — PARK PRESERVATION AND USES
  88. Chapter 3.24 — PARKS AND PUBLIC GROUNDS
  89. Article I — General Provisions
  90. Article II — Permits
  91. Article III — Use Restrictions
  92. Article IV — Uses Requiring Permission
  93. Article V — Refunds—Penalties
  94. Chapter 3.28 — CIVIL DEFENSE TRAINING CENTER
  95. Chapter 3.32 — ARROYO SECO PUBLIC LANDS
  96. Article I — General Provisions
  97. Article II — Natural Preservation Area
  98. Article III — Brookside Park Area
  99. Article IV — Rose Bowl Area
  100. Article V — Brookside Golf Course Area
  101. Title 3 — FOOTNOTES
  102. Chapter 4.02 — SALE OF SURPLUS REAL PROPERTY
  103. Chapter 4.04 — DISPOSITION OF SALVAGE AND SCRAP PROPERTY
  104. Chapter 4.08 — PURCHASING
  105. Chapter 4.10 — CREDIT AND COLLECTION
  106. Chapter 4.11 — PASADENA LIVING WAGE ORDINANCE
  107. Chapter 4.12 — CIGARETTE TAX
  108. Chapter 4.16 — PARK PURCHASE AND DEVELOPMENT FUND
  109. Chapter 4.17 — RESIDENTIAL IMPACT FEE
  110. Chapter 4.18 — CAPITAL PROJECTS FUND
  111. Chapter 4.19 — TRAFFIC REDUCTION AND TRANSPORTATION IMPROVEMEN…
  112. Chapter 4.20 — GAS TAX STREET IMPROVEMENT FUND
  113. Chapter 4.24 — UNDERGROUND UTILITIES SPECIAL ACTIVITY FUND
  114. Chapter 4.28 — PROPERTY TAXES
  115. Chapter 4.29 — TRANSFER OF PROPERTY TAX FUNCTIONS
  116. Chapter 4.32 — CONSTRUCTION TAX
  117. Chapter 4.36 — REAL PROPERTY TRANSFER TAX8
  118. Chapter 4.40 — SALES AND USE TAX
  119. Chapter 4.42 — TRANSACTIONS AND USE TAX
  120. Chapter 4.44 — TRANSIENT OCCUPANCY TAX
  121. Chapter 4.48 — ROSE BOWL ADMISSIONS TAX
  122. Chapter 4.52 — SEWER USE FEE AND STORM DRAIN CHARGE
  123. Chapter 4.53 — SEWER FACILITY CHARGE
  124. Chapter 4.54 — STREET LIGHT AND TRAFFIC SIGNAL TAX
  125. Chapter 4.56 — UTILITY USERS TAX
  126. Chapter 4.60 — VEHICLE OFF-STREET PARKING DISTRICTS
  127. Chapter 4.65 — VEHICLE OFF-STREET PARKING DISTRICTS
  128. Chapter 4.70 — URBAN IMPROVEMENT DISTRICTS
  129. Article 1 — General Provisions and Definitions
  130. Chapter 4.90 — CITY OF PASADENA ECONOMIC DEVELOPMENT REVENUE B…
  131. Chapter 4.95 — PUBLIC WORKS BENEFIT ASSESSMENT DISTRICTS
  132. Chapter 4.100 — POWER DIVISION GENERAL FUND TRANSFER
  133. Chapter 4.101 — PASADENA TOURISM BUSINESS IMPROVEMENT DISTRICT
  134. Chapter 4.105 — SALES TAX INCENTIVES
  135. Chapter 4.106 — MOBILE SOURCE AIR POLLUTION REDUCTION ORDINANCE
  136. Chapter 4.107 — CITY OF PASADENA SPECIAL TAX FINANCING IMPROVE…
  137. Chapter 4.108 — SEISMIC AND FIRE SAFETY IMPROVEMENT ASSESSMENT…
  138. Chapter 4.109 — LIBRARY SPECIAL TAX
  139. Title 4 — FOOTNOTES
  140. Chapter 5.02 — PAYMENT OF A CITY-WIDE MINIMUM WAGE
  141. Chapter 5.04 — GENERAL PROVISIONS
  142. Chapter 5.08 — DEFINITIONS
  143. Chapter 5.10 — LICENSE REGULATIONS
  144. Chapter 5.12 — EXEMPTIONS TO TAX
  145. Chapter 5.16 — FEES FOR MISCELLANEOUS BUSINESSES
  146. Chapter 5.20 — ADVERTISEMENTS
  147. Chapter 5.24 — ALARM SYSTEMS
  148. Chapter 5.28 — CANNABIS BUSINESS TAX
  149. Chapter 5.32 — BILLIARD AND POOL ROOMS
  150. Chapter 5.33 — BINGO GAMES
  151. Chapter 5.34 — CHARITABLE SOLICITATIONS
  152. Chapter 5.35 — CONCEALABLE FIREARMS—RETAIL SALES
  153. Chapter 5.40 — ESCORT BUREAUS
  154. Chapter 5.44 — FRANCHISE GRANTS FOR USE OF PUBLIC WAYS
  155. Chapter 5.45 — SEXUALLY ORIENTED BUSINESSES
  156. Chapter 5.48 — MASSAGE ESTABLISHMENTS
  157. Chapter 5.56 — PAWNBROKERS, JUNK AND SECONDHAND DEALERS
  158. Chapter 5.60 — SALES AND CLOSE-OUTS
  159. Chapter 5.68 — UNDERGROUND FACILITIES USE
  160. Chapter 5.72 — VEHICLES FOR HIRE
  161. Chapter 5.74 — LICENSURE OF TOBACCO RETAILERS
  162. Chapter 5.78 — COMMERCIAL CANNABIS ACTIVITY
  163. Chapter 5.80 — COVID-19 RIGHT OF RECALL
  164. Chapter 5.82 — COVID-19 WORKER RETENTION ORDINANCE
  165. Title 5 — FOOTNOTES
  166. Chapter 6.04 — GENERAL PROVISIONS
  167. Chapter 6.08 — CITY POUND AND POUNDMASTER
  168. Chapter 6.09 — DOGS AND CATS TO BE SPAYED OR NEUTERED
  169. Chapter 6.12 — RUNNING AT LARGE
  170. Chapter 6.16 — DOG LICENSE REGULATIONS
  171. Chapter 6.18 — REGULATION OF VICIOUS, POTENTIALLY DANGEROUS, A…
  172. Chapter 6.20 — FOWL AND LIVESTOCK RESTRICTIONS
  173. Chapter 6.24 — KENNELS AND VETERINARIES
  174. Chapter 6.28 — PIGEONS
  175. Chapter 6.32 — HEALTH AND SANITATION
  176. Chapter 6.36 — RABIES CONTROL
  177. Chapter 6.40 — RESTRICTION ON DISPLAY OF ANIMALS ON CITY PROPE…
  178. Title 6 — FOOTNOTES
  179. Title 8 — HEALTH AND SAFETY
  180. Chapter 8.04 — GENERAL PROVISIONS
  181. Chapter 8.08 — COSMETOLOGICAL ESTABLISHMENTS
  182. Chapter 8.10 — COMMERCIAL CANNABIS PUBLIC HEALTH PERMIT
  183. Chapter 8.11 — COMMERCIAL CANNABIS FACILITIES
  184. Chapter 8.12 — FOOD ESTABLISHMENTS
  185. Chapter 8.13 — HEALTH INSPECTION REPORT POSTING ORDINANCE
  186. Chapter 8.14 — GREASE AND OIL DISPOSAL ORDINANCE
  187. Chapter 8.16 — MOBILE FOOD FACILITIES AND FOOD TRANSPORTATION …
  188. Chapter 8.18 — DEEMED APPROVED ALCOHOLIC BEVERAGE RETAIL SALE …
  189. Chapter 8.19 — GROUP HOMES FOR THE DISABLED WHICH ARE NOT LICE…
  190. Chapter 8.20 — BUILDING DEMOLITION
  191. Chapter 8.24 — BUILDING SANITATION
  192. Chapter 8.28 — RAT AND INSECT CONTROL
  193. Chapter 8.32 — FUMIGATION
  194. Chapter 8.36 — PUBLIC SWIMMING POOLS
  195. Chapter 8.40 — USED CLOTHING
  196. Chapter 8.44 — HAZARDOUS WEEDS AND PLANTS
  197. Chapter 8.48 — WEEDS AND RUBBISH
  198. Chapter 8.52 — CITY TREES AND TREE PROTECTION ORDINANCE
  199. Chapter 8.56 — HEDGES AND FENCES
  200. Chapter 8.60 — SOLID WASTE
  201. Chapter 8.61 — SOLID WASTE COLLECTION FRANCHISE SYSTEM
  202. Chapter 8.62 — WASTE MANAGEMENT PLAN FOR CERTAIN CONSTRUCTION …
  203. Chapter 8.63 — DISPOSABLE ACCESSORY FOODWARE ITEM OPT-IN REQUI…
  204. Chapter 8.64 — LITTER CONTROL
  205. Chapter 8.65 — PLASTIC CARRYOUT BAGS
  206. Chapter 8.66 — ORGANICS RECYCLING REQUIREMENTS FOR RESIDENTIAL…
  207. Chapter 8.67 — PROHIBITION OF THE DISTRIBUTION OR SALE OF PREP…
  208. Chapter 8.68 — WATER POLLUTION
  209. Chapter 8.70 — STORMWATER MANAGEMENT AND DISCHARGE CONTROL
  210. Chapter 8.76 — ELECTRICAL MATERIALS SAFETY STANDARDS
  211. Chapter 8.77 — RESERVED
  212. Chapter 8.78 — TOBACCO USE PREVENTION ORDINANCE
  213. Chapter 8.79 — CHILDHOOD LEAD HAZARDS REDUCTION ORDINANCE
  214. Chapter 8.80 — HANDLING AND DISCLOSURE OF HAZARDOUS MATERIALS
  215. Chapter 8.82 — DISCRIMINATION AGAINST VICTIMS OF AIDS
  216. Chapter 8.85 — WEAPONS—SALES PROHIBITED ON CITY PROPERTY AND I…
  217. Chapter 8.92 — BUILDING ELECTRIFICATION
  218. Title 8 — FOOTNOTES
  219. Title 9 — PUBLIC PEACE, MORALS AND WELFARE
  220. Chapter 9.20 — GAMING AND GAMBLING
  221. Chapter 9.24 — ALCOHOLIC BEVERAGES IN PUBLIC
  222. Chapter 9.26 — DEFECATION AND URINATION IN PUBLIC
  223. Chapter 9.28 — INDECENT EXPOSURE
  224. Chapter 9.36 — NOISE RESTRICTIONS
  225. Chapter 9.37 — LEAF-BLOWING MACHINES
  226. Chapter 9.40 — BALL GAME BACKSTOPS
  227. Chapter 9.41 — COMBUSTIBLE BALLOONS
  228. Chapter 9.42 — FORMATION FLYING
  229. Chapter 9.43 — FEES FOR SECOND OR SUBSEQUENT RESPONSE TO PROVI…
  230. Chapter 9.44 — DISTRIBUTION OF UNSOLICITED WRITTEN MATERIAL (R…
  231. Chapter 9.45 — UNMANNED AIRCRAFT SYSTEMS
  232. Chapter 9.48 — FIRE HYDRANTS
  233. Chapter 9.52 — TRESPASSING
  234. Chapter 9.56 — OBSTRUCTING PUBLIC PLACE OR BUSINESS
  235. Chapter 9.58 — ABANDONED VEHICLE ABATEMENT
  236. Chapter 9.60 — GRAFFITI ABATEMENT ORDINANCE
  237. Chapter 9.62 — ABANDONED SHOPPING CARTS
  238. Article VI — Consumer Protection
  239. Chapter 9.68 — CURFEW
  240. Chapter 9.69 — SEALING OF SEXUALLY EXPLICIT MATERIAL
  241. Chapter 9.70 — SALE AND DISPLAY OF NARCOTIC PARAPHERNALIA
  242. Chapter 9.75 — TENANT PROTECTION
  243. Chapter 9.76 — PROHIBITED EQUIPMENT
  244. Chapter 9.78 — UNSERIALIZED FIREARMS
  245. Chapter 9.80 — DISCHARGING
  246. Chapter 9.84 — HAZARDOUS WEAPONS
  247. Chapter 9.88 — FAIR CAMPAIGN PRACTICES AND DISCLOSURE ORDINANCE
  248. Chapter 9.89 — ELECTRONIC FILING OF CAMPAIGN DISCLOSURE INFORM…
  249. Chapter 9.90 — REPORTING SALES OF UNREGULATED CHEMICALS
  250. Chapter 9.95 — EVICTION DUE TO ILLEGAL DRUG DEALING ACTIVITIES
  251. Chapter 9.97 — ELLIS ACT TENANT PROTECTIONS
  252. Title 9 — FOOTNOTES
  253. Chapter 10.04 — GENERAL PROVISIONS
  254. Chapter 10.08 — DEFINITIONS
  255. Chapter 10.12 — ADMINISTRATION, ENFORCEMENT AND PENALTY
  256. Chapter 10.16 — TRAFFIC-CONTROL DEVICES
  257. Chapter 10.20 — TURNING MOVEMENTS
  258. Chapter 10.24 — ONE-WAY STREETS AND ALLEYS
  259. Chapter 10.28 — STOPS AND YIELDS
  260. Chapter 10.32 — PEDESTRIANS
  261. Chapter 10.36 — DRIVING RULES
  262. Chapter 10.38 — VEHICULAR CRUISING
  263. Chapter 10.39 — VEHICLE SOLICITATION IN THE STREETS
  264. Chapter 10.40 — STOPPING, STANDING AND PARKING
  265. Chapter 10.41 — PREFERENTIAL PARKING
  266. Chapter 10.42 — DAYTIME PARKING
  267. Chapter 10.44 — PARKING AT NIGHT
  268. Chapter 10.45 — PARKING METERS
  269. Chapter 10.46 — POLICE TOWING FRANCHISE SYSTEM
  270. Chapter 10.48 — SPEED LIMITS
  271. Chapter 10.52 — TRUCK ROUTES
  272. Chapter 10.53 — LOCAL INTERSTATE TRUCK ROUTES
  273. Chapter 10.56 — TRAINS AND CROSSINGS
  274. Chapter 10.60 — BICYCLES
  275. Chapter 10.61 — SKATEBOARDS, ROLLER SKATES, SCOOTERS AND EPAMD
  276. Chapter 10.64 — TRANSPORTATION MANAGEMENT PROGRAM
  277. Chapter 10.65 — PARKING PROHIBITIONS ON CERTAIN STREETS ON RED…
  278. Title 10 — FOOTNOTES
  279. Title 12 — STREETS AND SIDEWALKS
  280. Chapter 12.04 — SIDEWALK REPAIR AND RECONSTRUCTION
  281. Chapter 12.08 — NEWSRACKS
  282. Chapter 12.10 — SIDEWALK VENDORS
  283. Chapter 12.12 — OBSTRUCTING STREETS AND SIDEWALKS
  284. Chapter 12.13 — OUTDOOR DINING WITHIN PUBLIC RIGHTS-OF-WAY
  285. Chapter 12.14 — VALET PARKING
  286. Chapter 12.15 — POSTING ON PUBLIC PROPERTY
  287. Chapter 12.16 — MOVING BUILDINGS ALONG STREETS
  288. Chapter 12.20 — BUILDING NUMBERING
  289. Chapter 12.22 — TELECOMMUNICATIONS FACILITIES
  290. Chapter 12.24 — EXCAVATIONS
  291. Chapter 12.25 — CLOSING OF STREETS WITHOUT VACATION
  292. Chapter 12.28 — IMPROVEMENT ASSESSMENTS
  293. Title 12 — FOOTNOTES
  294. Chapter 13.04 — POWER RATES AND REGULATIONS
  295. Chapter 13.08 — ENERGY USE CONSERVATION
  296. Chapter 13.10 — WATER WASTE PROHIBITIONS AND WATER SUPPLY SHOR…
  297. Chapter 13.11 — NON-POTABLE WATER
  298. Chapter 13.12 — UTILITY LOCATION MAPS
  299. Chapter 13.14 — UNDERGROUND UTILITY DISTRICTS
  300. Chapter 13.16 — UTILITY LATERALS CONNECTION2
  301. Chapter 13.18 — POLES AND WIRES
  302. Chapter 13.20 — WATER SERVICE AND RATES
  303. Chapter 13.22 — RESERVED
  304. Article I — Definitions and General Provisions
  305. Article II — Design and Construction
  306. Article III — Maintenance and Operation
  307. Chapter 13.28 — WATER MAIN ASSESSMENTS5
  308. Chapter 13.32 — GOVERNMENT CONTROLLED WATERCOURSES
  309. Title 13 — FOOTNOTES
  310. Chapter 14.03 — ADMINISTRATIVE CODE
  311. ▸Chapter 14.04 — BUILDING CODE AND RELATED CODES
  312. Chapter 14.05 — EXCAVATION AND GRADING IN HILLSIDE AREAS
  313. Chapter 14.06 — EARTHQUAKE HAZARD REDUCTION IN EXISTING UNREIN…
  314. Chapter 14.07 — SAFETY ASSESSMENT PLACARDS
  315. Chapter 14.08 — MANDATORY SEISMIC STRENGTHENING PROVISIONS FOR…
  316. Chapter 14.12 — HOUSING CODE
  317. Chapter 14.16 — QUADRENNIAL CERTIFICATE OF INSPECTION
  318. Chapter 14.17 — PRESALE SELF-CERTIFICATION PROGRAM
  319. Chapter 14.20 — CROSS-CONNECTION CONTROL BOARD
  320. Chapter 14.26 — FIRE AND EMERGENCY PLANNING REQUIREMENTS FOR H…
  321. Chapter 14.27 — FLOODPLAIN MANAGEMENT REGULATIONS
  322. Chapter 14.28 — FIRE PREVENTION CODE
  323. Chapter 14.29 — FLAMMABLE VEGETATION
  324. Chapter 14.30 — FIREWORKS, PYROTECHNICS AND PRODUCTION EFFECTS
  325. Chapter 14.37 — FEES AND SCHEDULES
  326. Chapter 14.50 — PROPERTY MAINTENANCE AND NUISANCE ABATEMENT
  327. Chapter 14.60 — ABATEMENT OF BUILDINGS EXHIBITING SLUMLIKE CON…
  328. Chapter 14.70 — VACANT BUILDING AND VACANT LOT MAINTENANCE AND…
  329. Chapter 14.80 — FIRST SOURCE HIRING
  330. Chapter 14.90 — EXPEDITED PERMITTING PROCEDURES FOR SMALL RESI…
  331. Title 14 — FOOTNOTES
  332. Title 16 — SUBDIVISIONS
  333. Chapter 16.04 — GENERAL PROVISIONS AND ENFORCEMENT
  334. Chapter 16.08 — DEFINITIONS
  335. Chapter 16.12 — DESIGN STANDARDS
  336. Chapter 16.16 — IMPROVEMENTS
  337. Chapter 16.18 — GENERAL PROCEDURES
  338. Chapter 16.20 — TENTATIVE MAPS
  339. Chapter 16.22 — VESTING TENTATIVE MAPS
  340. Chapter 16.24 — SURVEY REQUIREMENTS4
  341. Chapter 16.28 — FINAL MAPS AND PARCEL MAPS
  342. Chapter 16.32 — DEDICATIONS
  343. Chapter 16.36 — BONDS AND DEPOSITS
  344. Chapter 16.40 — MINOR LAND DIVISIONS
  345. Chapter 16.44 — MODIFICATIONS
  346. Chapter 16.46 — STANDARDS FOR CONVERSION PROJECTS
  347. Title 16 — FOOTNOTES
  348. Title 17 — Zoning Code
  349. Chapter 17.10 — Enactment and Applicability of Zoning Code
  350. Chapter 17.12 — Interpretation of Zoning Code Provisions
  351. Chapter 17.20 — Zoning Map
  352. Chapter 17.21 — Development and Land Use Approval Requirements
  353. Chapter 17.22 — Residential Zoning Districts
  354. Chapter 17.24 — Commercial and Industrial Zoning Districts
  355. Chapter 17.26 — Special Purpose Zoning Districts
  356. Chapter 17.28 — Overlay Zoning Districts
  357. Chapter 17.29 — Hillside Overlay Districts
  358. Chapter 17.30 — Central District Specific Plan
  359. Chapter 17.31 — East Colorado Specific Plan 2022
  360. Chapter 17.32 — East Pasadena Specific Plan
  361. Chapter 17.33 — Fair Oaks-Orange Grove Specific Plan
  362. Chapter 17.34 — North Lake Specific Plan
  363. Chapter 17.35 — South Fair Oaks Specific Plan
  364. Chapter 17.36 — West Gateway Specific Plan
  365. Chapter 17.37 — Lincoln Avenue Specific Plan
  366. Chapter 17.38 — Lamanda Park Specific Plan
  367. Chapter 17.39 — East Colorado Specific Plan 2003
  368. Chapter 17.40 — General Property Development and Use Standards
  369. Chapter 17.42 — Inclusionary Housing Requirements
  370. Chapter 17.43 — Density Bonus, Waivers and Incentives
  371. Chapter 17.44 — Landscaping
  372. Chapter 17.46 — Parking and Loading
  373. Chapter 17.48 — Signs
  374. Chapter 17.50 — Standards for Specific Land Uses
  375. Chapter 17.60 — Application Filing and Processing
  376. Chapter 17.61 — Permit Approval or Disapproval
  377. Article 2 — Zoning Districts, Allowable Land Uses, and Zone-Sp…
  378. Chapter 17.62 — Historic Preservation
  379. Chapter 17.64 — Permit Implementation, Time Limits, and Extens…
  380. Chapter 17.66 — Development Agreements
  381. Chapter 17.68 — Specific Plans
  382. Chapter 17.70 — Administrative Responsibility
  383. Chapter 17.71 — Nonconforming Uses, Structures, and Lots
  384. Chapter 17.72 — Appeals
  385. Chapter 17.74 — Amendments
  386. Chapter 17.76 — Public Hearings
  387. Chapter 17.78 — Enforcement
  388. Chapter 17.80 — Glossary of Specialized Terms and Land Use Types
  389. Title 18 — CABLE, VIDEO AND TELECOMMUNICATIONS SERVICE PROVIDERS
  390. Chapter 18.02 — GENERAL PROVISIONS
  391. Chapter 18.04 — CABLE TELEVISION SYSTEMS
  392. Chapter 18.06 — OPEN VIDEO SYSTEMS
  393. Chapter 18.08 — OTHER VIDEO AND TELECOMMUNICATIONS SERVICES AN…
  394. Chapter 18.10 — DEFINITIONS
  395. Chapter 18.12 — VIOLATIONS; SEVERABILITY
  396. Part 40 — A(2) (12.16)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.