Los Angeles County Municipal Code § 2007.10 Ground-based helicopter facilities
Los Angeles County Municipal Code · 2026-09 edition · updated 2026-10-04 · Los Angeles County
Cite as: Los Angeles County Municipal Code § 2007.10 · Text as of 2026-10-04
A ground-based helicopter landing facility subject to this code, that is required for use to some degree by public emergency services, shall be constructed in accordance with Sections 2007.10.1 through 2007.10.3. These requirements may also be applied to such facilities that are elevated.
2007.10.1 - Surface.¶
When required by the fire code official, a graded pad, measuring a minimum of 100 feet (30 480 mm) by 100 feet (30 480 mm), shall be covered with reinforced concrete, with a minimum depth of 6 inches (152.4 mm), capable of supporting 42,000 pounds (19 050.88 kg).
2007.10.2 - Hydrant.¶
When required by the fire code official, a fire hydrant shall be installed adjacent to the pad as approved by the fire code official.
2007.10.3 - Access.¶
When required by the fire code official, a fire apparatus access road leading to the helistop or heliport shall be provided in accordance with Section 503.