Chapter 3 — GENERAL REGULATIONS
301.5 Alternative Engineered Design. An alternative
California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
engineered design shall comply with the intent of the provisions of this code and shall provide an equivalent level of quality, strength, effectiveness, fire resistance, durability, and safety. Material, equipment, or components shall be designed and installed in accordance with the manufacturer’s installation instructions.
301.5.1 Permit Application. The registered design professional shall indicate on the design documents that the plumbing system, or parts thereof, is an alternative engineered design so that it is noted on the construction permit application. The permit and permanent permit records shall indicate that an alternative engineered design was part of the approved installation. 301.5.2 Technical Data. The registered design professional shall submit sufficient technical data to substantiate the proposed alternative engineered design and to prove that the performance meets the intent of this code. 301.5.3 Design Documents. The registered design professional shall provide two complete sets of signed and sealed design documents for the alternative engineered design for submittal to the Authority Having Jurisdiction. The design documents shall include floor plans and a riser diagram of the work. Where appropriate, the design documents shall indicate the direction of flow, pipe sizes, grade of horizontal piping, loading, and location of fixtures and appliances. 301.5.4 Design Approval. An approval of an alternative engineered design shall be at the discretion of the Authority Having Jurisdiction. The exercise of this discretionary approval by the Authority Having Jurisdiction shall have no effect beyond the jurisdictional boundaries of said Authority Having Jurisdiction. An alternative engineered design so approved shall not be considered as in accordance with the requirements, intent, or both of this code for a purpose other than that granted by the Authority Having Jurisdiction.
301.5.5 Design Review. The Authority Having Jurisdiction shall have the authority to require testing of the alternative engineered design in accordance with Section 301.3.1, including the authority to require an independent review of the design documents by a registered design professional selected by the Authority Having Jurisdiction and at the expense of the applicant. 301.5.6 Inspection and Testing. The alternative engineered design shall be tested and inspected in accordance with the submitted testing and inspection plan and the requirements of this code.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
- Chapter 1 — GENERAL CODE PROVISIONS
- Chapter 2 — DEFINITIONS
▸Chapter 3 — GENERAL REGULATIONS
Overview- 301.1 Applicability. This chapter shall govern the general
- 301.2 Minimum Standards. Pipe, pipe fittings, traps, fixtures,…
- 301.3 Alternate Materials and Methods of Construc-
- 301.4 Flood Hazard Areas. Plumbing systems shall be
- 301.5 Alternative Engineered Design. An alternative
- 301.6 One- and Two-Family Dwellings. [HCD 1] The
- 301.7 OSHPD 1R [OSHPD 1R]. For OSHPD 1R, refer to
- 302.1 General. Iron, steel, copper, and copper alloy pipe
- 303.1 General. It shall be unlawful for a person to cause,
- 304.1 General. Plumbing fixtures, drains, appurtenances,
- 305.1 Unlawful Practices. It shall be unlawful for a person to…
- 306.1 Detrimental Wastes. Wastes detrimental to the public sew…
- 306.2 Safe Discharge. Sewage or other waste from a
- 307.1 System. Except as otherwise provided in this code,
- 307.2 Ownership. No subdivision, sale, or transfer of ownershi…
- 308.1 General. Piping, fixtures, or equipment shall not be
- 309.1 Engineering Practices. Design, construction, and
- 309.2 Concealing Imperfections. It is unlawful to conceal crac…
- 309.3 Burred Ends. Burred ends of pipe and tubing shall
- 309.4 Installation Practices. Plumbing systems shall be
- 309.5 Sound Transmission. Plumbing piping systems
- 309.6 Dead Legs. Dead legs shall have a method of flushing.
- 310.1 Fittings. No double hub fitting, single or double tee
- 310.2 Drainage and Vent Piping. No drainage or vent
- 310.3 Waste Connection. No waste connection shall be
- 310.4 Use of Vent and Waste Pipes. Except as hereinafter provi…
- 310.5 Obstruction of Flow. No fitting, fixture and piping
- 310.6 Dissimilar Metals. Except for necessary valves,
- 310.7 Direction of Flow. Valves, pipes, and fittings shall
- 310.8 Screwed Fittings. Screwed fittings shall be ABS,
- 310.9 [OSHPD 1, 2, 3, 4 & 5] Drainage piping over oper-
- 310.10 [OSHPD 1, 3, 4 & 5] Floor drains, waste traps, san-
- 310.11 [SFM] For applications listed in Section 1.11.0 regu-
- 310.12 [OSHPD 1, 2, 4 & 5] Services/Systems and Util-
- 310.13 Telephone and Data Equipment Rooms
- 311.1 General. The drainage system of each new building
- 312.1 General. Piping passing under or through walls shall
- 312.2 Installation. Piping in connection with a plumbing
- 312.3 Building Sewer and Drainage Piping. No building sewer or…
- 312.4 Corrosion, Erosion, and Mechanical Damage.
- 312.5 Protectively Coated Pipe. Protectively coated pipe
- 312.6 Freezing Protection. No water, soil, or waste pipe
- 312.7 Fire-Resistant Construction. Piping penetrations
- 312.8 Waterproofing of Openings. Joints at the roof
- 312.9 Steel Nail Plates. Plastic and copper or copper alloy
- 312.10 Sleeves. Sleeves shall be provided to protect piping th…
- 312.11 Structural Members. A structural member weakened or imp…
- 312.12 Rodentproofing. Strainer plates on drain inlets
- 313.1 General. Piping, fixtures, appliances, and appurtenances…
- 313.2 Material. Hangers and anchors shall be of sufficient
- 313.3 Suspended Piping. Suspended piping shall be supported at…
- 313.4 Alignment. Piping shall be supported in such a manner as…
- 313.5 Underground Installation. Piping in the ground
- 313.6 Hanger Rod Sizes. Hanger rod sizes shall be not
- 313.7 Gas Piping. Gas piping shall be supported by metal
- 313.8 [OSHPD 1, 2, 3, 4 & 5] Refer to Title 24, Part 2 of the
- 314.1 Trenches. Trenches deeper than the footing of a
- 314.2 Tunneling and Driving. Tunneling and driving shall
- 314.3 Open Trenches. Excavations required to be made
- 314.4 Excavations. Excavations shall be completely backfilled …
- 315.1 Unions. Approved unions shall be permitted to be
- 315.2 Prohibited Joints and Connections. A fitting or
- 316.1 General. Where different sizes of pipes and fittings
- 317.1 General. Food or drink shall not be stored, prepared,
- 318.1 General. Tests in accordance with this code, which
- 318.2 Pressure Tests (10 psi or less). Required pressure tests…
- 318.3 Pressure Tests (greater than 10 psi to 100 psi).
- 318.4 Pressure Tests (exceeding 100 psi). Required
- 318.5 Pressure Range. Test gauges shall have a pressure
- 319.1 General. Such piping shall be in accordance with the
- 320.1 General. Where pressure piping systems are rehabilitated…
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …