Skip to content

Chapter 10 — TRAPS AND INTERCEPTORS

1014.3 Gravity Grease Interceptors. Required gravity

California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-10 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

grease interceptors shall comply with the provisions of Section 1014.3.1 through Section 1014.3.7.

1014.3.1 General. The provisions of this section shall apply to the design, construction, installation, and testing of commercial kitchen gravity grease interceptors. 1014.3.2 Waste Discharge Requirements. Waste discharge in establishments from fixtures and equipment which contain grease, including but not limited to, scullery sinks, pot and pan sinks, dishwashers, soup kettles, and floor drains located in areas where grease-containing materials exist, shall be permitted to be drained into the sanitary waste through the interceptor where approved by the Authority Having Jurisdiction.

1014.3.2.1 Toilets and Urinals. Toilets, urinals, and other similar fixtures shall not drain through the interceptor. 1014.3.2.2 Inlet Pipe. Waste shall enter the interceptor through the inlet pipe. 1014.3.3 Design. Gravity interceptors shall be constructed in accordance with the applicable standard in Chapter 17 or the design approved by the Authority Having Jurisdiction. 1014.3.4 Location. Each grease interceptor shall be so installed and connected that it shall be easily accessible for inspection, cleaning, and removal of the intercepted grease. A gravity grease interceptor that complies with IAPMO Z1001 shall not be installed in a building where food is handled. Location of the grease interceptor shall meet the approval of the Authority Having Jurisdiction.

1014.3.4.1 Interceptors. Interceptors shall be placed as close as practical to the fixtures they serve. 1014.3.4.2 Business Establishment. Each business establishment for which a gravity grease interceptor is required shall have an interceptor

196 2022 CALIFORNIA PLUMBING CODE

which shall serve that establishment unless otherwise approved by the Authority Having Jurisdiction. 1014.3.4.3 Access. Each gravity grease interceptor shall be located to be readily accessible to the equipment required for maintenance. 1014.3.5 Construction Requirements. Gravity grease interceptors shall be designed to remove grease from effluent and shall be sized in accordance with this section. Gravity grease interceptors shall also be designed to retain grease until accumulations can be removed by pumping the interceptor. It is recommended that a sample box is located at the outlet end of gravity grease interceptors so that the Authority Having Jurisdiction can periodically sample effluent quality. 1014.3.6 Sizing Criteria. The volume of the interceptor shall be determined by using Table 1014.3.6. Where drainage fixture units (DFUs) are not known, the interceptor shall be sized based on the maximum DFUs allowed for the pipe size connected to the inlet of the interceptor. Refer to Table 703.2, Drainage Piping, Horizontal.

TABLE 1014.3.6 GRAVITY GREASE INTERCEPTOR SIZING

TRAPS AND INTERCEPTORS

EXAMPLE 1014.3.6 GRAVITY GREASE INTERCEPTOR SIZING EXAMPLE Given: A restaurant with the following fixtures and equipment. One food preparation sink; three-floor drains - one in the food prep area, one in the grill area, and one receiving the indirect waste from the ice machine and a mop sink.

Kitchen Drain Line DFU Count (from Table 702.1): 3 floor drains at 2 DFUs each = 6 DFUs Mop sink at 3 DFUs each = 3 DFUs Food prep sink at 3 DFUs each = 3 DFUs Total = 12 DFUs

Using Table 1014.3.6, the grease interceptor will be sized at 750 gallons (2389 L).

1014.3.7 Abandoned Gravity Grease Intercep- tors. Abandoned grease interceptors shall be pumped and filled as required for abandoned sewers and sewage disposal facilities in Section 722.0.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Plumbing Code (Title 24, Part 5)
California Plumbing Code (Title 24, Part 5)
  1. Chapter 1 — GENERAL CODE PROVISIONS
  2. Chapter 2 — DEFINITIONS
  3. Chapter 3 — GENERAL REGULATIONS
  4. Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
  5. Chapter 5 — WATER HEATERS
  6. Chapter 6 — WATER SUPPLY AND DISTRIBUTION
  7. Chapter 7 — SANITARY DRAINAGE
  8. Chapter 8 — INDIRECT WASTES
  9. Chapter 9 — VENTS
  10. Chapter 10 — TRAPS AND INTERCEPTORS
    Overview
    1. 1001.1 Applicability. This chapter shall govern the materials,…
    2. 1001.2 Where Required. Each plumbing fixture shall be
    3. 1002.1 Vent Pipes. Each plumbing fixture trap, except as
    4. 1002.2 Fixture Traps. Each fixture trap shall have a protectin…
    5. 1002.3 Change of Direction. A trap arm shall be permitted to c…
    6. 1002.4 Vent Pipe Opening. The vent pipe opening from
    7. 1003.1 General Requirements. Each trap, except for
    8. 1003.2 Slip Joint Fittings. A maximum of one approved
    9. 1003.3 Size. The size (nominal diameter) of a trap for a
    10. 1004.1 Prohibited. No form of trap that depends for its seal
    11. 1004.2 Movable Parts. Bladders, check valves or another
    12. 1005.1 General. Each fixture trap shall have a liquid seal of
    13. 1006.1 General. Floor drains shall connect into a trap so
    14. 1007.1 General. Floor drain or similar traps directly connecte…
    15. 1007.2 Trap Seal Primers. Potable water supply trap seal
    16. 1008.1 General. Building traps shall not be installed except
    17. 1009.1 Where Required. Interceptors (clarifiers) (including gr…
    18. 1009.2 Approval. The size, type, and location of each intercep…
    19. 1009.3 Design. Interceptors (clarifiers) for sand and similar
    20. 1009.4 Relief Vent. Interceptors (clarifiers) shall be so
    21. 1009.5 Location. Each interceptor (clarifier) cover shall be
    22. 1009.6 Maintenance of Interceptors. Interceptors shall be
    23. 1009.7 Discharge. The waste pipe from oil and sand interceptor…
    24. 1010.1 General. A fish, fowl, and animal slaughterhouse or
    25. 1010.2 [AGR] Meat and Poultry Processing Plants.
    26. 1010.3 [AGR] Collection Centers and Facilities. All
    27. 1010.4 [AGR] Horse Meat and Pet Food Establish-
    28. 1010.5 [AGR] Draining and Plumbing. There shall be
    29. 1011.1 General. A private or public wash rack or floor or slab
    30. 1012.1 General. Laundry equipment in commercial and industrial…
    31. 1013.1 General. Bottling plants shall discharge their process
    32. 1014.1 General. Where it is determined by the Authority Having…
    33. 1014.2 Hydromechanical Grease Interceptors. Plumbing fixtures …
    34. 1014.3 Gravity Grease Interceptors. Required gravity
    35. 1015.1 Purpose. The purpose of this section is to provide
    36. 1015.2 Components, Materials, and Equipment. FOG
    37. 1015.3 Sizing and Installation. FOG disposal systems
    38. 1015.4 Performance. FOG disposal systems shall produce
    39. 1015.5 [OSHPD 1, 1R, 2, 3, 4 & 5] Grease interceptors
    40. 1015.6 [OSHPD 1, 1R, 2, 3, 4 & 5] Grease interceptors
    41. 1016.1 Discharge. Where the discharge of a fixture or drain
    42. 1016.2 Authority Having Jurisdiction. Sand interceptors
    43. 1016.3 Construction and Size. Sand interceptors shall be
    44. 1016.4 Separate Use. Sand and similar interceptors for
    45. 1017.1 Interceptors Required. Repair garages and gasoline stat…
    46. 1017.2 Design of Interceptors. Each manufactured interceptor t…
  11. Chapter 11 — STORM DRAINAGE
  12. Chapter 12 — FUEL GAS PIPING
  13. Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
  14. Chapter 14 — FIRESTOP PROTECTION
  15. Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
  16. Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
  17. Chapter 17 — REFERENCED STANDARDS
  18. Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
  19. Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
  20. Appendix C — ALTERNATE PLUMBING SYSTEMS
  21. Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
  22. Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
  23. Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
  24. Appendix G — SIZING OF VENTING SYSTEMS
  25. Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
  26. Appendix I — INSTALLATION STANDARDS
  27. Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
  28. Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
  29. Appendix L — SUSTAINABLE PRACTICES
  30. Appendix M — PEAK WATER DEMAND CALCULATOR
  31. Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.