Chapter 1 — GENERAL CODE PROVISIONS
104.3 Application for Permit. To obtain a permit, the
California Plumbing Code (Title 24, Part 5) · 2022 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
applicant shall first file an application therefore in writing on a form furnished by the Authority Having Jurisdiction for that purpose. Such application shall: (1) Identify and describe the work to be covered by the per mit for which application is made. (2) Describe the land upon which the proposed work is to be
done by legal description, street address, or similar description that will readily identify and locate the proposed building or work. (3) Indicate the use or occupancy for which the proposed
work is intended.
22 2022 CALIFORNIA PLUMBING CODE
(4) Be accompanied by construction documents in accor dance with Section 104.3.1. (5) Be signed by the permittee or the permittee’s authorized
agent. The Authority Having Jurisdiction shall be permitted to require evidence to indicate such authority. (6) Give such other data and information in accordance with
the Authority Having Jurisdiction. 104.3.1 Construction Documents. Construction documents, engineering calculations, diagrams, and other data shall be submitted in two or more sets with each application for a permit. The construction documents, computations, and specifications shall be prepared by, and the plumbing designed by, a registered design professional. Construction documents shall be drawn to scale with clarity to identify that the intended work to be performed is in accordance with the code. Exception: The Authority Having Jurisdiction shall be permitted to waive the submission of construction documents, calculations, or other data where the Authority Having Jurisdiction finds that the nature of the work applied for is such that reviewing of construction documents is not necessary to obtain compliance with the code. 104.3.2 Plan Review Fees. Where a plan or other data is required to be submitted in accordance with Section 104.3.1, a plan review fee shall be paid at the time of submitting construction documents for review.
The plan review fees for plumbing work shall be determined and adopted by this jurisdiction.
The plan review fees specified in this subsection are separate fees from the permit fees specified in Section 104.5. Where plans are incomplete or changed so as to require additional review, a fee shall be charged at the rate shown in Table 104.5. 104.3.3 Time Limitation of Application. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, plans and other data submitted for review thereafter, shall be returned to the applicant or destroyed by the Authority Having Jurisdiction. The Authority Having Jurisdiction shall be permitted to exceed the time for action by the applicant for a period not to exceed 180 days upon request by the applicant showing that circumstances beyond the control of the applicant have prevented the action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
▸Chapter 1 — GENERAL CODE PROVISIONS
Overview- 1504.5 Irrigation, Disposal Field
- 1504.6 Reserved . . . . . . . . . . . . . . . . . . .312
- 1504.7 Reserved . . . . . . . . . . . . . . . . . . .312
- 101.1 Title. This document shall be known as the “Uniform
- 101.2 Scope. The provisions of this code shall apply to the
- 101.3 Purpose. This code is an ordinance providing minimum req…
- 101.4 Unconstitutional. Where a section, subsection, sentence,…
- 101.5 Validity. Where a provision of this code, or the applica…
- 102.1 Conflicts Between Codes. Where the requirements
- 102.2 Existing Installations. Plumbing systems lawfully
- 102.3 Maintenance. The plumbing and drainage system,
- 102.4 Additions, Alterations, Renovations, or Repairs.
- 102.5 Health and Safety. Where compliance with the provisions …
- 102.6 Changes in Building Occupancy. Plumbing systems that are…
- 102.7 Moved Structures. Parts of the plumbing system of
- 102.8 Appendices. The provisions in the appendices are
- 103.1 General. The Authority Having Jurisdiction shall be
- 103.2 Liability. The Authority Having Jurisdiction charged
- 103.3 Applications and Permits. The Authority Having
- 103.4 Right of Entry. Where it is necessary to make an
- 104.1 Permits Required. It shall be unlawful for a person,
- 104.2 Exempt Work. A permit shall not be required for the
- 104.3 Application for Permit. To obtain a permit, the
- 104.4 Permit Issuance. The application, construction documents…
- 104.5 Fees. Fees shall be assessed in accordance with the
- 105.1 General. Plumbing systems for which a permit is
- 105.2 Required Inspections. New plumbing work and
- 105.3 Testing of Systems. Plumbing systems shall be
- 105.4 Connection to Service Utilities. No person shall
- 106.1 General. It shall be unlawful for a person, firm, or
- 106.2 Notices of Correction or Violation. Notices of
- 106.3 Penalties. A person, firm, or corporation violating a
- 106.4 Stop Orders. Where work is being done contrary to
- 106.5 Authority to Disconnect Utilities in Emergen-
- 106.6 Authority to Condemn. Where the Authority Having Jurisdi…
- 107.1 General. In order to hear and decide appeals of orders,
- 107.2 Limitations of Authority. The Board of Appeals
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …