Chapter 1 — GENERAL CODE PROVISIONS
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
Sections in this part
- 301.7 One- and Two-Family Dwellings . .50
- 301.8 OSHPD 1R . . . . . . . . . . . . . . . . . . .50
- 310.14 Services/Systems and Utilities . . . .52
- 310.15 Telephone and Data
- 401.3 Water-Conserving Fixtures
- 422.8 Cosmetology . . . . . . . . . . . . . . . . .69
- 422.9 Cosmetology Establishments . . . . .69
- 422.10 Commissaries Serving Mobile
- 422.11 Employee Lavatories in
- 501.2 California Energy Code
- 601.4 Schools of Cosmetology and
- 601.5 Meat and Poultry Processing
- 601.6 Collection Centers and
- 601.7 Renderers . . . . . . . . . . . . . . . . . . .139
- 601.8 Horse Meat and Pet Food
- 615.1 Uses Not Permitted . . . . . . . . . . . . .162
- 616.0 Emergency Water Supply . . . . . . . .162
- 717.2 Meat and Poultry Processing
- 727.0 Emergency Sanitary Drainage . . .178
- 1010.2 Meat and Poultry Processing
- 1010.3 Collection Centers and
- 1010.4 Horse Meat and Pet Food
- 1010.5 Draining and Plumbing . . . . . . . .197
- 1211.8 Earthquake-Actuated Gas
- 1501.9 Signage . . . . . . . . . . . . . . . . . . . .310
- 1504.5 Irrigation, Disposal Field and
- 1504.6 Reserved . . . . . . . . . . . . . . . . . . .318
- 1504.7 Reserved . . . . . . . . . . . . . . . . . . .318
- 1505.15 Minimum Water Quality
- 1505.16 Maintenance and Inspection . . . .322
- 101.1 Title. This document shall be known as the “Uniform
- 101.2 Scope. The provisions of this code shall apply to the
- 101.3 Purpose.
- 101.4 Unconstitutional.
- 101.5 Validity.
- 102.1 Conflicts Between Codes. Where the requirements
- 102.2 Existing Installations. Plumbing systems lawfully
- 102.3 Maintenance. The plumbing and drainage system,
- 102.4 Additions, Alterations, Renovations, or Repairs.
- 102.5 Health and Safety.
- 102.6 Changes in Building Occupancy.
- 102.7 Moved Structures. Parts of the plumbing system of
- 102.8 Appendices. The provisions in the appendices are
- 103.1 General. The Authority Having Jurisdiction shall be
- 103.2 Liability. The Authority Having Jurisdiction charged
- 103.3 Applications and Permits. The Authority Having
- 103.4 Right of Entry. Where it is necessary to make an
- 104.1 Permits Required. It shall be unlawful for a person,
- 104.2 Exempt Work. A permit shall not be required for the
- 104.3 Application for Permit. To obtain a permit, the
- 104.4 Permit Issuance.
- 104.5 Fees. Fees shall be assessed in accordance with the
- 105.1 General. Plumbing systems for which a permit is
- 105.2 Required Inspections. New plumbing work and
- 105.3 Testing of Systems. Plumbing systems shall be
- 105.4 Connection to Service Utilities. No person shall
- 106.1 General. It shall be unlawful for a person, firm, or
- 106.2 Notices of Correction or Violation. Notices of
- 106.3 Penalties. A person, firm, or corporation violating a
- 106.4 Stop Orders. Where work is being done contrary to
- 106.5 Authority to Disconnect Utilities in Emergen-
- 106.6 Authority to Condemn.
- 107.1 General. In order to hear and decide appeals of orders,
- 107.2 Limitations of Authority. The Board of Appeals
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adopting Agency |
BSC | BSC- CG |
SFM | 1 | 2 | 1-AC | AC | ** SS** | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
Adopt Entire Chapter |
X | |||||||||||||||||||||||
Adopt Entire Chapter as amended (amended sections listed below) |
S | A | M | P | L | E | ||||||||||||||||||
Adopt only those sections that are listed below |
||||||||||||||||||||||||
Chapter/Section |
||||||||||||||||||||||||
| 202 |
Adopt the entire UPC chapter as amended, state-amended sections are listed below: If there is an “X” under a particular state agency’s acronym in this row, it means that a particular state agency has adopted the entire model code chapter, with state amendments.
Each section that a state agency has amended and/or added within a particular chapter is listed. There will be an “X” under an agency’s acronym in the row of the amended and/or added section.
Example:
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adopting Agency |
BSC | BSC- CG |
SFM | 1 | 2 | 1-AC | AC | ** SS** | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
Adopt Entire Chapter |
||||||||||||||||||||||||
Adopt Entire Chapter as amended (amended sections listed below) |
X | X | S | A | M | P | L | E | ||||||||||||||||
Adopt only those sections that are listed below |
||||||||||||||||||||||||
Chapter/Section |
||||||||||||||||||||||||
| 202 | X | X |
Adopt only those sections which are listed below: If there is an “X” under a particular state agency’s acronym in this row, it means that particular state agency is adopting only specific model code or state-amended sections within this chapter. There will be an “X” in the column under the agency’s acronym, as well as an “X” by each section that the agency has adopted.
Example:
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC- CG |
SFM | HCD | DSA | OSHPD | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adopting Agency |
BSC | BSC- CG |
SFM | 1 | 2 | 1-AC | AC | ** SS** | SS/CC | 1 | 1R | 2 | 3 | 4 | 5 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
Adopt Entire Chapter |
||||||||||||||||||||||||
Adopt Entire Chapter as amended (amended sections listed below) |
S | A | M | P | L | E | ||||||||||||||||||
Adopt only those sections that are listed below |
X | |||||||||||||||||||||||
Chapter/Section |
||||||||||||||||||||||||
101 |
X | |||||||||||||||||||||||
202 |
X |
viii 2025 CALIFORNIA PLUMBING CODE
HOW TO DISTINGUISH MODEL CODE LANGUAGE FROM CALIFORNIA AMENDMENTS
[BSC]
To distinguish between model code language and incorporated California Amendments, including exclusive California standards, California amendments will appear in italics font print.
Symbols in the margins indicate the status of code changes as follows:
This symbol identifies which State agency(s) by its “acronym” that has amended a section of the model code. For a complete listing of State agency acronyms, see the Application Section within Chapter 1, Division I.
This symbol indicates that a change has been made to a California amendment.
This symbol indicates that a section, paragraph, or table has been revised or relocated within IAPMO model code language.
This symbol indicates deletion of California language.
This symbol indicates where an entire section, paragraph, or table has been deleted from IAPMO model code language.
Revision Markings A double right angle ( « ) in the margin indicates that the text or a table has been relocated within the code.
TIA TIA indicates that the revision is the result of a Tentative Interim Amendment.
TIA TIA For further information on tentative interim amendments see Section 5 of the IAPMO TIA Regulations Governing Committee Projects available at http://codes.iapmo.org/
A reference in brackets [ ] following a section or paragraph indicates material that has been extracted from another document. This reprinted material is not the complete and official position of the source document on the referenced subject that is represented by the standard in its entirety. Material contained in this document that is taken or extracted from NFPA standards is used with permission of the National Fire Protection Association. This material is not the complete and official position of the NFPA on the reference subject, which is represented solely by the relevant standard in its entirety. NFPA standards can be accessed at www.nfpa.org. In addition, this extracted material may include revisions or modifications developed through IAPMO’s standards development process. Therefore, NFPA disclaims responsibility for the content of this Code.
Text that is extracted pursuant to IAPMO’s Extract Guidelines, but outside of the regular revision process is denoted with the use of the source document in the margin. This text is not fully processed by IAPMO in accordance with ANSI’s public announcement consensus requirements for an American National Standard (ANS) nor approved by ANSI’s Board of Standards Review. The next revision cycle processes such text in accordance with those requirements.
Important Notices and Disclaimers The 2024 edition of the Uniform Plumbing Code is developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on plumbing issues. While the International Association of Plumbing and Mechanical Officials (IAPMO) administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in its codes
and standards.
IAPMO disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this document. IAPMO also makes no guarantee or warranty as to the accuracy or completeness of any information published
herein.
In issuing and making this document available, IAPMO is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is IAPMO undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances.
Updating IAPMO Codes Users of IAPMO codes should be aware that IAPMO codes may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. IAPMO codes consist of the current edition of the document together with any Tentative Interim Amendment and any Errata in effect.
To access information for a specific code or to determine whether an IAPMO code has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, please visit the IAPMO codes information page on the IAPMO’s website (https://www.iapmo.org/codedevelopment). The codes information page provides a list of IAPMO codes with up-to-date, specific information including any issued Tentative Interim Amendments and Errata.
FOREWORD
Origin and Development The advantages of a statewide adopted Uniform Plumbing Code are recognized throughout the industry. Disorder in the industry because of widely divergent plumbing practices and the use of many different, often conflicting, plumbing codes by local jurisdictions influenced the Western Plumbing Officials Association (now the International Association of Plumbing and Mechanical Officials [IAPMO]) to form a committee. This committee of plumbing inspectors, master and journeyman plumbers, and plumbing engineers, backed by public utility companies and the plumbing industry to create a basic plumbing document for general use. The product of this effort, the first edition of the Uniform Plumbing Code [®] (UPC [®] ) was adopted by IAPMO in 1945. The widespread use of this code over the past seven decades by jurisdictions throughout the United States and internationally is testament to its merit.
Publishing of the 2003 Uniform Plumbing Code was a significant milestone because it was the first time in the history of the United States a plumbing code was developed through a true consensus process. The 2024 edition represents the most current approaches in the plumbing field and is the eighth edition developed under the ANSI consensus process. Contributions to the content of this code consists of diverse interests as consumers, enforcing authorities, installers/maintainers, labor, manufacturers, research/standards/ testing laboratories, special experts, and users.
The Uniform Plumbing Code provides consumers with safe and sanitary plumbing systems while, at the same time, allowing latitude for innovation and new technologies. The public at large is invited and encouraged to take part in IAPMO’s open consensus code development process. This code is updated every three years. The Uniform Plumbing Code is dedicated to all those who, in working to achieve “the ultimate plumbing code,” have unselfishly devoted their time, effort, and personal funds to create and maintain this, the finest plumbing code in existence today.
The Uniform Plumbing Code updates every three years in revision cycles that begin twice each year that takes two years to complete.
Each revision cycle advances according to a published schedule that includes final dates for all major events and contains four basic steps as follows:
- Proposal Stage;
- Comment Stage;
- Association Technical Meeting;
- Council Appeals and Issuance of Code.
IAPMO develops “full consensus” codes built on a foundation of maximum participation and agreement by a broad range of interests. This philosophy has led to producing technically sound codes that promote health and safety, yet do not stifle design or development.
It is important to stress that the process remains committed to the principles of consensus code development where consensus Technical Committees and Correlating Committees revise codes. The public and membership are offered multiple opportunities to debate, provide input and raise concerns through Amending Motions at the annual Assembly Consideration Session. Anyone may submit an appeal related to the issuance of a document through the IAPMO Standards Council.
The 2024 Uniform Plumbing Code is supported by the ASSE International (ASSE), Mechanical Contractors Association of America (MCAA), the Plumbing-Heating-Cooling Contractors National Association (PHCC-NA), the United Association (UA), and the World Plumbing Council (WPC). The presence of these logos, while reflecting support, does not imply any ownership of the copyright to the UPC, which is held exclusively by IAPMO. Further, the logos of these associations indicate the support of IAPMO’s open consensus process being used to develop IAPMO’s codes and standards.
FOREWORD
The addresses of the organizations are as follows: ASSE – 18927 Hickory Creek Drive, Suite 220 • Mokena, IL 60448 • (708) 995-3019 MCAA – 1385 Piccard Drive • Rockville, MD 20850 • (301) 869-5800 PCA – 1385 Piccard Drive • Rockville, MD 20850 • (301) 869-5800 PHCC-NA – 180 S Washington Street, Suite 100 • Falls Church, VA 22040-6808 • (800) 533-7694 UA – Three Park Place • Annapolis, MD 21401 • (410) 269-2000 WPC – Auf der Mauer 11 • 8021 Zurich, Switzerland • Secretariat@worldplumbing.org
Adoption The Uniform Plumbing Code is available for adoption and use by jurisdictions in the United States and Internationally. Its use within a governmental jurisdiction is accomplished through adoption by reference in accordance with applicable jurisdictional laws. At adoption, jurisdictions should insert the applicable information in bracketed words in the sample ordinance. The sample legislation for adoption of the Uniform Plumbing Code on page xx provides key components, regulations and resolutions.
Revision Markings
Solid vertical lines in the margins indicate a technical change from the requirements of the
2021 edition. An arrow ( ) in the margin indicates where an entire section, paragraph,
exception, figure, or table has been deleted, or an item in a list of items or a table has been
deleted.
A double right angle ( « ) in the margin indicates that the text, table, or figure has been relocated within the code. The table found on page xxii points out the relocations in the 2024 edition of the Uniform Plumbing Code .
TIA TIA indicates that the revision is the result of a Tentative Interim Amendment. TIA For further information on tentative interim amendments see Section 5 of the IAPMO TIA TIA Regulations Governing Committee Projects available at https://www.iapmo.org/code**TIA** development
A reference in brackets [ ] following a section or paragraph indicates material that has been extracted from another document. A reference in brackets { } following a section or paragraph indicates material that has been extracted from another document and has been modified further by the Technical Committee. This reprinted material is not the complete and official position of the source document on the referenced subject that is represented by the standard in its entirety. Material contained in this document that is taken or extracted from NFPA standards is used with permission of the National Fire Protection Association. This material is not the complete and official position of the NFPA on the reference subject, which is represented solely by the relevant standard in its entirety. NFPA standards can be accessed at www.nfpa.org. In addition, this extracted material may include revisions or modifications developed through IAPMO’s standards development process. Therefore, NFPA disclaims responsibility for the content of this code.
Text that is extracted pursuant to IAPMO’s Extract Guidelines, but outside of the regular revision process is denoted with the use of the source document in the margin. This text is not fully processed by IAPMO in accordance with ANSI’s public announcement consensus requirements for an American National Standard (ANS) nor approved by ANSI’s Board of Standards Review. The next revision cycle processes such text in accordance with those requirements.
xii 2025 CALIFORNIA PLUMBING CODE
FORMAT OF THE UNIFORM PLUMBING CODE
The format of the Uniform Plumbing Code (UPC) arranges each chapter in accordance with a specific subject matter. However, Chapter 3 is dedicated to general requirements that are applicable to every chapter. The subject matters are divided as follows:
| CHAPTERS | SUBJECTS |
|---|---|
| 1 | Administration |
| 2 | Definitions |
| 3 | General Regulations |
| 4 | Plumbing Fixtures and Fixture Fittings |
| 5 | Water Heaters |
| 6 | Water Supply and Distribution |
| 7 | Sanitary Drainage |
| 8 | Indirect Wastes |
| 9 | Vents |
| 10 | Traps and Interceptors |
| 11 | Storm Drainage |
| 12 | Fuel Gas Piping |
| 13 | Health Care Facilities and Medical Gas and Medical Vacuum Systems |
| 14 | Firestop Protection |
| 15 | Alternate Water Sources for Nonpotable Applications |
| 16 | Nonpotable Rainwater Catchment Systems |
| 17 | Referenced Standards |
| Appendix A | Recommended Rules for Sizing the Water Supply System |
| Appendix B | Explanatory Notes on Combination Waste and Vent Systems |
| Appendix C | Alternate Plumbing Systems |
| Appendix D | Sizing Storm Water Drainage Systems |
| Appendix E | Manufactured/Mobile Home Parks and Recreational Vehicle Parks |
| Appendix F | Firefighter Breathing Air Replenishment Systems |
| Appendix G | Sizing of Venting Systems |
| Appendix H | Private Sewage Disposal Systems |
| Appendix I | Installation Standards |
| Appendix J | Combination of Indoor and Outdoor Combustion and Ventilation Opening Design |
| Appendix K | Potable Rainwater Catchment Systems |
| Appendix L | Sustainable Practices |
| Appendix M | Peak Water Demand Calculator |
| Appendix N | Impact of Water Temperature on the Potential for Scalding and Legionella Growth |
| Appendix O | Non-Sewered Sanitation Systems |
| Appendix P | Professional Qualifications |
| Appendix Q | Indoor Horticultural Facilities |
| Appendix R | Tiny Houses |
| Appendix S | Onsite Stormwater Treatment Systems |
FORMAT OF THE UNIFORM PLUMBING CODE
The following is a summary of the scope and intent of the provisions addressed within the chapters and appendices of the Uniform Plumbing Code :
Chapter 1 Administration.
Chapter 1 regulates the application, enforcement, and administration of subsequent requirements of the code. As well as establishing the scope of the code, this chapter is concerned with enforcing the requirements contained in the body of the code. A plumbing code, as with any other code, is intended to be adopted as a legally enforceable document to safeguard health, safety, property, and public welfare. The code cannot be effective without satisfactory provisions for its administration and enforcement. The Authority Having Jurisdiction is to review the proposed and completed work and to decide whether a plumbing system conforms to the code requirements. As a public servant, the Authority Having Jurisdiction enforces the code in an unbiased, proper manner. The design professional is responsible for the design of a safe plumbing system. The contractor is responsible for installing the system in accordance with the plans.
Chapter 2 Definitions.
To maintain consistency and encourage the use of common terminology, Chapter 2 establishes definitions to provide clarity of terms and promote the use of a common language throughout the code. Understanding definitions within the context of their application enables greater collaboration, efficiency, standardization, and interpretation in applying and enforcing terms used throughout the code. Codes are technical documents, and every term can impact the meaning of the code text. Terms not defined have a normally accepted meaning.
Chapter 3 General Regulations.
Chapter 3 regulates the general requirements, not specific to other chapters, for installing plumbing systems. Many regulations are not specific plumbing requirements but relate to the overall plumbing system. This chapter contains safety requirements for installing plumbing and also contains nonplumbing requirements for identifying pipes, pipe fittings, traps, fixtures, materials, and devices used in plumbing systems. Listing method of approval, based on applicable nationally recognized standards, for the safe and proper installation of plumbing systems, is essential to ensure the protection of public health, safety, and welfare. The safety requirements provide protection for piping, material, and structures, with provisions for installation practices, removing stress and strain of the pipe, sleeving, and hanger support. The building’s structural stability is protected by the regulations for cutting and notching of structural members.
Chapter 4 Plumbing Fixtures and Fixture Fittings.
This chapter regulates the minimum number of plumbing fixtures of a specific type and quality for each building. The fixtures must be properly installed to be usable by the individuals occupying the building. The quality and design of every fixture must conform to the applicable referenced standard. Compliance with this chapter will result in a building or structure having acceptable plumbing fixtures for the sanitary, hygienic, cleaning, washing, and food preparation needs of the occupants. In addition to ensuring resilient fixtures, the chapter also takes into consideration gender-neutral facilities and contains provisions for privacy compartments.
Chapter 5 Water Heaters.
Chapter 5 regulates the design, approval, installation, and safety devices of fuel burning and other types of water heaters with the combustion air requirements for ventilation and dilution of flue gases for appliances installed in buildings. This chapter does not apply to direct-vent appliances. In addition, this chapter regulates the design, construction, installation, and maintenance of chimneys, vents, and their connections to fuel-burning appliances. Methods to supply combustion air may be supplied from an indoor air supply, outdoor air supply, a combination of indoor and outdoor air supply, mechanical air supply, or an engineered system. Combustion air provisions are based on the number of openings and the total opening size required based on the total energy input rating of the appliance. An acceptable air supply for combustion and ventilation is necessary for the proper operation of fuel-burning appliances. A shortage of combustion air can result in incomplete combustion and the production of poisonous gases, such as carbon monoxide or appliance overheating. Ventilation air provides cooling for the appliance casing and internal controls. Inadequate ventilation of the space in which an appliance is installed can result in increased surrounding temperatures that stress the appliance itself or other appliances in the vicinity.
xiv 2025 CALIFORNIA PLUMBING CODE
FORMAT OF THE UNIFORM PLUMBING CODE
Chapter 6 Water Supply and Distribution.
Chapter 6 regulates the design, material, and installation of water supply and distribution systems, including residential fire sprinklers. The water supply and distribution system is designed to achieve the correct water pressure and flow rates and avoid cross-connections. For fixtures to perform properly, an acceptable supply of potable water is essential to their operation and use. Cross-connections and backflow are ranked as the highest priority because of the long history of recognized health risks posed by cross-connections, outbreaks, or cases of waterborne disease. Piping materials and components are evaluated for their possible effect on the potable water with which they are in contact. The intent is to control the potential adverse health effects produced by indirect additives, products, and materials that come in contact with potable water. When selecting materials for water supply and distribution systems, consider water pressure, water temperature, compatibility with the water supply, durability, support, and sustainability.
In addition, this chapter regulates the design, location, materials, and installation of multipurpose and stand-alone sprinkler systems that do not include the use of antifreeze. Where systems are installed as a portion of the water distribution system under the requirements of this chapter and are not provided with a fire department connection, backflow protection for the water supply system is not required.
Chapter 7 Sanitary Drainage.
This chapter regulates the design and installation of sanitary drainage systems to ensure they will work as intended. Drainage piping should not be oversized nor undersized, and constructed of approved materials to guard against fouling, deposit of solids, clogging, and with cleanouts so arranged that the pipes may be readily cleaned. The purpose of the sanitary drainage system is to remove effluent discharged from plumbing fixtures and other equipment to an approved point of disposal, such as a public sanitary system or private sewage disposal system.
The basics of a sanitary drainage system include public and private sewage disposal; selection of materials; installation of the building drain and sewer; joining methods for pipe and fittings; drainage fixture units for sizing the drainage system; sumps and ejectors; vent sizing and length of vents; and testing.
Chapter 8 Indirect Wastes.
Chapter 8 regulates indirect waste connections that are required for plumbing fixtures and plumbing appliances dealing with food preparation, dishwashing, potable liquids, and similar equipment. An indirect connection prevents sewage from backing up into a fixture or appliance, thus providing protection against potential health hazards. The waste pipe discharges through an air gap or air break into a waste receptor or standpipe. The protection in the form of an air gap is necessary when the contamination is a potential health hazard or cross connection with the potable water system. Where there is no possibility of contaminating the potable water (nonpotable discharge), the indirect waste pipe may connect in the form of an air break. This method is often preferred to prevent splashing. In addition, health care facilities and special wastes must be protected from contamination that may result from the connection to the drainage system. The waste must be treated to prevent any damage to the piping or sewage treatment process. Waste receptors are sized and designed to prevent splashing and allow for peak discharge conditions.
Chapter 9 Vents.
Chapter 9 regulates the material, design, and installation of vents. A vent system is a pipe or pipes installed in a drainage system that provide a flow of air to and from the system to ventilate it, provide a circulation of air to eliminate trap siphonage, and reduce back-pressure and vacuum surge. In addition, vents provide the rapid and silent flow of waste without exposing occupants of the building to any sewer gases. Proper installation of vents is crucial, as a telltale sign that there is a problem in the drain and vent system is related to the elevation of the horizontal portion of the venting. Venting is not limited to sanitary drainage systems. Venting methods are applicable to other drainage systems such as those for chemical waste, graywater waste, and clear water waste. Sizing the venting system is directly tied to the design of the drainage system. For example, the velocities in the drainage system and its peak flow rates affect the diameters in the venting system. Where the vertical distance between a fixture outlet and trap is excessive, velocities in the entire drainage system will be greater than those in the vent sizing table. All venting methods in this chapter are categorized as either dry vents or wet vents. Vent stacks, stack vents, branch vents, island vents, relief vents, and individual vents are dry vents. Wet vents (horizontal or vertical), circuit vents, combination drain and vents are versions of “wet venting” in which the vent is wetted by drainage flow.
FORMAT OF THE UNIFORM PLUMBING CODE
Chapter 10 Traps and Interceptors.
Chapter 10 regulates the material, design, and installation of traps, interceptors, and separators. Traps are required on drainage type plumbing fixtures and must be self-scouring without interior partitions. Interceptors, on the other hand, are designed to control what goes down a drain. Interceptors are used to keep harmful substances from entering the sanitary drainage system, such as grease, sand, oil and other materials. The retained materials need periodic removal to maintain efficiency and function of the separating device. The capacity of an interceptor is based on retention and flow rate. There are many types of interceptors that are used at beauty salons, hospitals, meat, fish or foul packaging, refineries, repair garages, gas stations, car washing facilities, various plants, factories, and processing sites. The designer of the building is responsible for locating interceptors with the expectation for the frequency of maintenance, ease of cleaning and floor space for equipment.
Chapter 11 Storm Drainage.
Chapter 11 regulates the removal of stormwater from roofs, yards, paved areas, and similar areas. The objective of storm drainage systems is to provide a conduit or channel through which runoff will be carried from a point of collection to a point of disposal; this protects the property and the public from the uncontrolled flow of runoff and ensures that drains and inlets are adequately sized to receive the volume of runoff that flows to the drains. For the purpose of system design, it’s necessary to specify the duration of a selected storm. All methods used to determine volumes and peak flow use historical data. Drain location must be coordinated with the architectural design of the building. When selecting the type of roof drain to use, the roof construction and its thickness, along with the intended use of the roof, are required. Where the roof perimeter extends above the roof in such a manner that water is entrapped and causes ponding, or if any portion of the roof is designed so water can pond, secondary drainage is required. Where secondary drainage is required, scuppers, or a secondary system of roof drains and pipes, are installed to prevent the accumulation of excessive rainwater.
Chapter 12 Fuel Gas Piping.
Chapter 12 regulates the installation of gas piping in a building, structure or within the property lines of buildings up to 5 psi. Gas piping systems must supply the minimum volume of gas required by each gas appliance to perform their proper operation under working conditions without exceeding the maximum pressure specified by each manufacturer. Because of the hazards associated with fuel gas, it is important to ensure the gas system has been inspected and tested, and that it is safe to turn on the gas supply to the building.
Chapter 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems.
Chapter 13 regulates the installation, inspection, testing, maintenance, performance, and safe practices for medical gas and vacuum systems located in health care facilities. This chapter addresses the installation and maintenance of health care fixtures, devices, and equipment. The purpose of medical gas and medical vacuum systems is to provide safe and sufficient flows at required pressures to the medical gas outlet or vacuum inlet terminals. System design and layout should allow convenient access by the medical staff to outlet and inlet terminals, valves, and equipment during patient care or emergencies, as safety is of primary concern.
Chapter 14 Firestop Protection.
Chapter 14 regulates piping penetrations of fire-resistance-rated walls, partitions, floors, floor and ceiling assemblies, roof and ceiling assemblies, or shaft enclosures through firestopping. To firestop is to create a physical barrier that impedes the spread of smoke, gases, and flames from one compartment in the building design to the next. The firestop is seen as a part that is essential to protecting the lives of people who live or work in the structure, increasing the chances of not succumbing to smoke or gases before they are able to evacuate the building. Fireproofing of this type helps to restore the fire-resistant properties of the building materials before the openings were created as part of the construction process.
Chapter 15 Alternate Water Sources for Nonpotable Applications.
Chapter 15 regulates gray water sources, reclaimed (recycled) water sources and on-site treated nonpotable water systems. Water sources include subsurface irrigation, subsoil irrigation, and mulch basin systems. Subsoil water irrigation provides a means to disperse shallow drip irrigation lines and mulch basins that collect and spread water in various applications. The
xvi 2025 CALIFORNIA PLUMBING CODE
FORMAT OF THE UNIFORM PLUMBING CODE
reclaimed water provisions to on-site nonpotable water systems include gray water and other nonpotable water sources that are used for on-site applications. Water reuse is integral to sustainable water management because it allows water to remain in the environment and be preserved for future use while meeting the water requirements of the present. Water reuse reduces energy use by removing added potable water treatment, offsetting water demands, and providing water for energy production.
Chapter 16 Nonpotable Rainwater Catchment Systems.
Chapter 16 regulates nonpotable rainwater catchment systems that include irrigation; toilet and urinal flushing with proper treatment; provisions where permits are required; maintenance of alternate water sources; and minimum water quality. This chapter provides guidance on how to optimize rainwater use while ensuring there is a decrease of risk to consumers from poor design, installation, and maintenance. Rainwater harvesting is the process of capturing, channeling, and storing water runoff for later use. Most systems are constructed of three principal components: the catchment area, the collection device, and the conveyance system.
Chapter 17 Referenced Standards.
Chapter 17 provides two comprehensive tables with referenced standards. The standards listed in Table 1701.1 are applied as indicated in the applicable reference section(s). A list of additional approved standards, publications, practices, and guides that are not referenced in specific sections appear in Table 1701.2.
Referenced standards set forth specific details of accepted practices, materials specifications, or test methods in many specialized applications. Standards provide an efficient method of conveying complex information and specifications on the performance requirements for materials, products, systems, application, and installation. The manner and purpose for a standard’s use and, in turn, code compliance, must be definitive in all references to the standard. If the standard is intended to be a requirement for judging code compliance, the code must state its intent for use. The standard should adequately address a defined need and at the same time specify the minimum performance requirements, technical characteristics and methods of testing, and required test results.
The referenced standards tables are organized in a manner that makes it easy to find specific standards in alphabetical order, and by acronym of the publishing agency of the standard. The tables list the title of the standard, the edition, and any addenda. Contact information for each publishing agency is provided at the end of the chapter.
Appendix A Recommended Rules for Sizing the Water Supply System.
Appendix A provides a method of sizing the water supply and distribution system that provides precise calculations to establish the proper pressures and flow to the system’s fixtures. The goal of sizing the system is to deliver an acceptable volume of water to the most hydraulically remote fixture during minimum pressure and maximum flow conditions; provide satisfactory water pressure to the most hydraulically remote fixture during minimum pressure and maximum flow conditions; and to prevent excessive water velocity during maximum flow conditions.
Appendix B Explanatory Notes on Combination Waste and Vent Systems.
Appendix B contains general guidelines for the design and installation of combination waste and vent systems. These systems are designed for waste piping and are purposely oversized to serve as both a waste and vent pipe to avoid excessive pneumatic effects at fixture drains.
Appendix C Alternate Plumbing Systems.
The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate materials, and equipment that are not specifically covered in other parts of the code. Alternative methods are allowed to be used where approved by the authority having jurisdiction. Approval of alternatives is based on a demonstration showing that the method or material used is at least equivalent in strength, deflection, and capacity to that provided by the prescriptive methods and materials.
Appendix D Sizing Storm Water Drainage Systems.
Appendix D provides general guidelines for the sizing of stormwater drainage systems. There are two pieces of information that must always be a given. They are the roof size and the rate of rainfall for the area.
FORMAT OF THE UNIFORM PLUMBING CODE
Appendix E Manufactured/Mobile Home Parks and Recreational Vehicle Parks.
The provisions of this appendix apply to the plumbing and drainage systems of mobile home and recreational vehicle parks. These provisions also apply to the use, maintenance, and installation for supplying fuel gas, water, electricity, and disposal of sewage from accessory buildings or structures, and building components.
Appendix F Firefighter Breathing Air Replenishment Systems.
Appendix F provides guidance on installing firefighter breathing air replenishment systems. System components include outside fire department connection panel, interior air fill panel or station, interconnected piping distribution system and pressure monitoring switch. Fire departments access the system through an outside connection panel and are able to pump air into the system. The firefighters inside the structure access the system at fill stations that are found throughout the building. The piping distribution system is made from stainless tubing or other approved materials. It delivers compressed air to the building’s interior air-fill stations and interior air-fill panels. The tubing also acts as a conduit in the interior of the building between the outside connection panel and the air storage system. If the system becomes over-pressurized, the air monitoring system also acts as a pressure relief. A system isolation valve is placed alongside each interior air fill station and interior air fill panel to isolate the system.
Appendix G Sizing of Venting Systems.
Appendix G provides added information on the sizing of gas vents. This appendix is useful to the end user for the proper sizing of venting systems. A series of examples are given that show how to use the tables and other requirements of Chapter 5.
Appendix H Private Sewage Disposal Systems.
Appendix H provides general guidelines for the materials, design, and installation of new or existing private sewage disposal systems. Where a building cannot be served by a public sewer system, the building site must be provided with a system for treating the wastewater generated from the use of plumbing fixtures in the building. The appendix addresses site evaluations, materials, soil absorption systems, holding tanks, cesspools, and on-site wastewater treatment systems. Private sewage disposal systems must be designed based on the soil conditions, constructed using approved materials, and installed according to prescribed dimensions.
Appendix I Installation Standards.
Installation standards are industry standards that specify procedures for the installation of plumbing and mechanical products, and the inspection methods and procedures employed for the examination of such systems. These comprehensive standards add detailed information and guidance that a manufacturer or product installation instructions may not fully address. These standards give the user confidence with options from industry experts for installing plumbing products and assemblies in a safe and professional manner.
Appendix J Combination of Indoor and Outdoor Combustion and Ventilation Opening Design.
Appendix J provides an example of how to determine the required combination of indoor and outdoor combustion air opening sizes for appliances. The combustion air example also provides a table that contains the required volume of a space per the appliance Btu/h input that is based on the standard method.
Appendix K Potable Rainwater Catchment Systems.
Potable rainwater catchment system is defined as a system that uses the principal of collecting and using rain from a rooftop or other man-made, aboveground collection surface. This appendix applies to new rainwater catchment installations, as well as changes, additions, maintenance, and repairs to existing installations. Rainwater harvesting is the practice of collecting the water produced during rainfall events before it has a chance to run off into a river or stream or soak into the ground and become groundwater.
Appendix L Sustainable Practices.
This appendix provides a comprehensive set of technically sound provisions that encourage sustainable practices and works toward improving the design and construction of plumbing systems that result in a positive long-term environmental impact. Environmental sustainability is important because it involves natural resources that human beings need for economic or manufactured capital. Their sustainability is defined by their reliance on infinitely available resources that are naturally occurring, constant, and free to access.
xviii 2025 CALIFORNIA PLUMBING CODE
FORMAT OF THE UNIFORM PLUMBING CODE
Appendix M Peak Water Demand Calculator.
This appendix provides a method for estimating the demand load for the building water supply and principal branches for single- and multi-family dwellings with water-conserving plumbing fixtures, fixture fittings, and appliances.
Appendix N Impact Of Water Temperature On The Potential For Scalding And Legionella Growth.
Legionnaires’ disease is a serious issue that is a threat to many citizens. It is known that the higher the temperature, the lower the risk for Legionella growth, but the higher the temperature, the higher the possibility for scalding. This appendix addresses Legionella growth potential and scald potential within specified temperature ranges. It contains definitions for terms used to describe water temperatures such as cold, tepid, warm, tempered hot, and disinfecting hot. Since plumbing systems operate within various temperature ranges, the public has a document that identifies such temperature ranges and the “potential” dangers within these temperature ranges.
Appendix O Non-Sewered Sanitation Systems.
This appendix contains provisions on non-sewered sanitation systems which are suitable for use in temporary or permanent settlements, including refugee camps, and are equally suited to both public and private use in isolated locations. Additionally, the appendix provides general safety and performance requirements for design and testing of non-sewered sanitation systems for prefabricated integrated treatment units. These systems will apply to any integrated sanitation system that is not attached to a sewer.
Appendix P Professional Qualifications.
Appendix P provides a baseline of knowledge for installers, inspectors, or employers working with and around the systems covered within the scope of this code to keep all persons safe and healthy.
Appendix Q Indoor Horticultural Facilities.
Appendix Q addresses plumbing systems for horticultural cultivation and processing of plants for human ingestion, inhalation, and topical application. The appendix provisions apply to primary and secondary horticultural facilities. Primary horticultural facilities are devoted to the growing and/or harvesting of plants. Cultivation rooms are located within these facilities, while a secondary horticultural facility is devoted to the harvesting (such as hulling or shelling), packing, and/or holding of plants.
Appendix R Tiny Houses.
Appendix R guidance for the tiny house communities including regulations for fixtures, approved materials, and provisions for protecting the potable water system. This appendix serves as a foundation to establish safe practices and requirements that will provide a safe, healthy, and reliable plumbing system for the tiny house.
Appendix S Onsite Stormwater Treatment Systems.
Appendix S provides provisions for the water quality, monitoring, design, construction, alteration, repair, and operation requirements of onsite stormwater treatment systems for nonpotable use.
SAMPLE LEGISLATION FOR ADOPTION OF THE UNIFORM PLUMBING CODE
The Uniform Codes are designed to be adopted by jurisdictions through an ordinance. Jurisdictions wishing to adopt the 2024 Uniform Plumbing Code as an enforceable regulation governing plumbing systems by reference should ensure the legal basis under which adoption and implementation are included in the ordinance.
The following sample ordinance is a guide for drafting an ordinance for adoption that addresses key components regulations and resolutions.
ORDINANCE NO.
An ordinance of the [JURISDICTION] adopting the 2024 edition of the Uniform Plumbing Code, regulating and controlling the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems in the [JURISDICTION]; providing for the issuance of permits and collection of fees therefor; repealing Ordinance No. of the [JURISDICTION] and all other ordinances and parts of the ordinances in conflict therewith.
The [GOVERNING BODY] of the [JURISDICTION] does ordain as follows:
Section 1 Codes Adopted by Reference. That certain documents, three (3) copies of which are on file in the office of the [JURISDICTION'S KEEPER OF RECORDS] and the [JURISDICTION], being marked and designated as the 2024 Uniform Plumbing Code, including Appendix Chapters [FILL IN THE APPENDIX CHAPTERS BEING ADOPTED], as published by the International Association of Plumbing and Mechanical Officials, be and is hereby adopted as the Code of the [JURISDICTION], in the State of [STATE NAME] regulating and controlling the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems as herein provided; providing for the issuance of permits and collection of fees therefor; and each and all of the regulations, provisions, penalties, conditions and terms of such 2024 Uniform Plumbing Code on file in the office of the
[JURISDICTION] are hereby referred to, adopted, and made a part hereof, as if fully set out in this ordinance.
Section 2 Modifications. The following sections are hereby revised: Section 101.1. Insert: [NAME OF JURISDICTION] Section 104.5. Insert: [APPROPRIATE FEE SCHEDULE]
Section 3 Conflicting Ordinances Repealed. That Ordinance No. of [JURISDICTION] entitled
[TITLE OF THE ORDINANCE OR ORDINANCES IN EFFECT AT THE PRESENT TIME SO THAT THEY WILL BE REPEALED BY MENTION] and all other ordinances or parts of ordinances in conflict herewith are hereby repealed.
Section 4 Preemption. [JURISDICTION] hereby fully occupies and preempts the entire field of regulation of design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems; and provision for the issuance of permits and collection of fees therefor; within the boundaries of [JURISDICTION]. [AS APPROPRIATE] Cities, towns, and counties or other municipalities may enact only those laws and ordinances relating to this field as specifically authorized by state law and consistent with this ordinance. Local laws and ordinances that are inconsistent with, more restrictive than, or exceed the requirements of [ORDINANCE NO.] shall not be enacted and are hereby expressly preempted and repealed, regardless of the nature of the code, charter, or home rule status of such city, town, county, or municipality.
Section 5 Severability. That if any section, subsection, sentence, clause or phrase of this ordinance is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this ordinance. The [GOVERNING BODY] hereby declares that it would have passed this ordinance, and each section, subsection, clause or phrase thereof, irrespective of the fact that any one or more sections, subsections, sentences, clauses and phrases be declared unconstitutional.
, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this ordinance. The [GOVERNING BODY] hereby declares that it would have passed this ordinance, and each section, subsection, clause or phrase thereof, irrespective of the fact that any one or more sections, subsections, sentences, clauses and phrases be declared unconstitutional.
Section 6 Legal Notice. That the [JURISDICTION'S KEEPER OF RECORDS] is hereby ordered and directed to cause this ordinance to be published. (An additional provision may be required to direct the number of times the ordinance is to be published and to specify that it is to be in a newspaper in general circulation. Posting may also be required.)
Section 7 Violations and Penalties. [INCORPORATE PENALTIES FOR VIOLATIONS]
Section 8 Effective Date. That this ordinance and the rules, regulations, provisions, requirements, orders and matters established and adopted hereby shall take effect and be in full force and effect [TIME PERIOD] from and after the date of its final passage and adoption.
xx 2025 CALIFORNIA PLUMBING CODE
COMMITTEE ON UNIFORM PLUMBING CODE
These lists represent the membership at the time the Committee was balloted on the final text of this edition. Since that time, changes in the membership may have occurred.
IAPMO Standards Council Bill Erickson, Chairperson CJ Erickson Plumbing Company [I/M]
JT Baca, State of New Mexico [E] Laura Ceja, United Association [L] Rick Coffman, City of Cedar Falls, Retired [C] Marty Cooper, Vice Chairperson, City of Foster City [E]
Jim Imprescia, City of Leominster [E] Doug Marian, District Council 16 [L] Jim Stack, Stack Plumbing, Inc. [I/M] Don Summers, Plumber’s & Pipefitters Training Center [L]
Nonvoting
Gabriella M. Davis, Secretary, IAPMO Hugo Aguilar, Recording Secretary, IAPMO
IAPMO Uniform Plumbing Code Technical Committee Dan Daniels, Chairperson, Self [C]
Bob Adler, 4Leaf, Inc. [E] Sarah Aguilar, McCabe Plumbing [I/M] Rawand Aryan, City of Los Angeles Department of Building & Safety [E] Julius Ballanco, JB Engineering & Code Consulting [SE] DJ Berger, National ITC Corporation [U] Gary Bonetti, UA Local #342 JATC [L] Jeremy Brown, NSF International [R/S/T] Michael Cudahy, Plastic Pipe & Fittings Association (PPFA) [M] Pennie Feehan, Copper Development Association (CDA) [M] Brian Fenty, Self [E] Ed Gormley, Gormley Plumbing & Mechanical [I/M] Lingyan Gorsuch, Arup [SE]
Engineering & Code Consulting [SE] DJ Berger, National ITC Corporation [U] Gary Bonetti, UA Local #342 JATC [L] Jeremy Brown, NSF International [R/S/T] Michael Cudahy, Plastic Pipe & Fittings Association (PPFA) [M] Pennie Feehan, Copper Development Association (CDA) [M] Brian Fenty, Self [E] Ed Gormley, Gormley Plumbing & Mechanical [I/M] Lingyan Gorsuch, Arup [SE]
Ephraim Kreitenberg, Kreit Mechanical Associates, Inc. [SE] David Mann, CA State Pipe Trades Council [L] John Nielsen, State of Idaho – Division of Building Safety [E] Johnnie Norris, United Association [L] Phil Ribbs, PHR Consultants [SE] Arnold Rodio, Pace Setter Plumbing [I/M] Brad Senecaut, City of Hillsboro [E] Robert Sewell, Lescure Company [U] Larry Soskin, ACE Duraflo [M] Billy Smith, American Society of Plumbing Engineers (ASPE) [SE] Don Taylor, Dittmann Plumbing [U] Chuck White, Plumbing-Heating-Cooling Contractors National Association (PHCC-NA) [I/M]
Alternates
Chris Cheek, National ITC Corporation [U] Richard Church, Plastic Pipe & Fittings Association (PPFA) [M] Tim Knight, UA Local #342 JATC [L] Ramiro Mata, American Society of Plumbing Engineers (ASPE) [SE]
David Orton, NSF International [R/S/T] Dan Rademacher, United Association [L] Martin Salberg, Pace Setter Plumbing [I/M] Kevin Sullivan, UA Local #342 JATC [L]
Nonvoting
Matthew Barker, National Fire Protection Association (NFPA) [R/S/T] David Gans, Ex-Officio, IAPMO [E] Enrique Gonzalez, IAPMO Staff Liaison
Alexander Ing, National Fire Protection Association (NFPA) [R/S/T] Doug Marian, ASSE [R/S/T]
COMMITTEE MEMBERSHIP CLASSIFICATION ABBREVIATIONS
These classifications apply to Technical Committee members and represent their principal interest in the activity of a committee.
M Manufacturer: A representative of a maker or marketer of a product, assembly or system, or portion thereof, that is affected by the standard. U User: A representative of an entity that is subject to the provisions of the standard or that voluntarily uses the standard. I/M Installer/Maintainer: A representative of an entity that is in the business of installing or maintaining a product, assembly or system affected by the standard. L Labor: A labor representative or employee concerned with safety in the workplace. R/S/T Research/Standards/Testing Laboratory: A representative of an independent research organization; an organization that develops codes, standards or other similar documents; or an independent testing laboratory. E Enforcing Authority: A representative or an agency or an organization that promulgates and/or enforces standards. C Consumer: A person who is, or represents, the ultimate purchaser of a product, system, or service affected by the standard, but who is not included in the User classification. SE Special Expert: A person not representing any of the previous classifications, but who has special expertise in the scope of the standard or portion thereof.
SECTION RELOCATION
| 2024 Location | 2021 Location |
|---|---|
| L 411.14 - L 411.14.3 | L 411.10 - L 411.10.3 |
| L 411.16 - L 411.17 | L 411.12 - L 411.13 |
| Table L 502.7.1 | Table L 502.7 |
| L 503.2.1 | L 503.2 |
| N 102.1 | N 102.1 - N 102.10 |
| 2024 Location | 2021 Location |
|---|---|
| 206.0 Diverter Valve, Gray Water |
209.0 Gray Water Diverter Valve |
| 212.0 Joint, Heat-Fusion | 210.0 Heat-Fusion Weld Joints |
| 408.3 - 408.4.2 | 408.2 - 408.3.2 |
| 408.5 - 408.11 | 408.4 - 408.10 |
| 409.6.2 | 409.6.1 |
| 422.1.2 | 422.1.1 |
| 507.21 - 507.26 | 507.22 - 507.27 |
| 509.8.1 | 509.8.2 |
| Figure 509.8.1 | Figure 509.8 |
| Table 509.8.1 | Table 509.8.2 |
| 509.8.2, 509.8.3 | 509.8.4, 509.8.5 |
| 509.10.7 - 509.10.13.1 | 509.10.6 - 509.10.12.1 |
| 603.5.20 - 603.5.22 | 603.5.19 - 603.5.21 |
| 607.3 - 607.6 | 607.2 - 607.5 |
| 1017.4 | 1017.2 |
| 1208.2 - 1208.5.1 | 1208.3 - 1208.6.1 |
| Table 1208.3.1 | Table 1208.4.1 |
| 1208.5.2 - 1208.5.8.2 | 1208.6.3 - 1208.6.9.2 |
| Table 1208.5.8.2 | Table 1208.6.9.2 |
| 1208.5.8.3 - 1208.7.3 | 1208.6.9.3 - 1208.8.3 |
| 1208.7.4 | 1208.8.4 |
| 1208.7.5 - 1208.14.1 | 1208.8.7 - 1208.15.1 |
| 1212.1.2, 1212.1.3 | 1212.1.1, 1212.1.2 |
| 1323.13.3, 1323.13.4 | 1323.13.2, 1323.13.3 |
| 1326.4 - 1326.10 | 1326.5 - 1326.11 |
| 1505.6 - 1505.14 | 1505.5 - 1505.13 |
| Figure 1505.10 | Figure 1505.9 |
| 1506.6 - 1506.13 | 1506.5 - 1506.12 |
| 1603.3 - 1603.4 | 1603.4 - 1603.5 |
| Table 1603.4 | Table 1603.5 |
| 1603.5 - 1603.19 | 1603.6 - 1603.20 |
| 1603.20 | 1503.2.4 |
| L 402.9 - L 402.11 | L 402.8 - L 402.10 |
| L 404.9 - L 404.12 | L 404.8 - L 404.11 |
| L 411.5, L 411.6 | L 411.2, L411.3 |
| L 411.7 | L 411.4 |
| L 411.9 - L 411.12 | L 411.5 - L 411.8 |
xxii 2025 CALIFORNIA PLUMBING CODE
RELATED PUBLICATIONS AND SERVICES
The Documents Listed are Not by this Reference Adopted by The State of California.
IAPMO provides a variety of other products which are useful for inspectors, building officials, architects, engineers,
manufacturers, contractors, plumbers, and apprentices.
IAPMO Headquarters Directory
4755 East Philadelphia Street, Ontario, California 91761-2816
Publication Order Desk Phone: 800-85-IAPMO
Publication Toll Free Fax: 877-85-CODES
E-mail: iapmo@iapmo.org
Website: www.iapmo.org
Free Code Question: 800-201-0335
Uniform Plumbing Code – 2024 Edition:
The Uniform Plumbing Code is the most widely adopted plumbing code in the world. The 2024 edition contains complete “turnkey” requirements for the installation and maintenance of plumbing systems, all in one easy to use book.
Uniform Plumbing Code Illustrated Training Manual:
The UPC Illustrated Training Manual is an excellent reference for anyone involved in the plumbing industry. It contains an extensive definitions section and several hundred comprehensive technical diagrams and illustrations. It serves as a textbook, and it also is useful as a valuable tool for explaining the intent and use of the Code.
Uniform Plumbing Code Study Guide:
This book is the perfect complement to the UPC Illustrated Training Manual. Alone, it constitutes a complete self-study course for learning the UPC. It has hundreds of questions, general practice exams, and plumbing math, pipe sizing exercises and fitting identification. A big help in getting you ready for a certification exam!
Guide to Important Code Questions to the Uniform Plumbing Code:
An excellent reference for learning and understanding plumbing code changes and identifies code changes between editions. It is a useful tool for preparing code change proposals.
Uniform Mechanical Code – 2024 Edition:
The Uniform Mechanical Code contains complete requirements for the installation and maintenance of heating, ventilating, cooking and refrigeration systems.
Uniform Mechanical Code Illustrated Training Manual:
Contains technical diagrams and illustrations that demonstrate the intent and use of the UMC. A great reference for everyone involved in Mechanical HVACR design and installation.
Uniform Mechanical Code Study Guide:
The Study Guide is a complete self-study course for learning the UMC. A big help in getting ready for a certification exam! This book is the perfect complement to the UMC Illustrated Training Manual.
Guide to Important Code Questions to the Uniform Mechanical Code:
An excellent reference for learning and understanding mechanical code changes and identifies code changes between editions. It is a useful tool for preparing code change proposals.
RELATED PUBLICATIONS AND SERVICES
The Documents Listed are Not by this Reference Adopted by The State of California.
Uniform Swimming Pool, Spa, and Hot Tub Code – 2024 Edition: The Uniform Swimming Pool, Spa and Hot Tub Code contains complete and current requirements for the erection, installation, alteration, repair, relocation, replacement, addition to and use or maintenance of these systems.
Uniform Solar, Hydronics and Geothermal Code – 2024 Edition: The Uniform Solar, Hydronics and Geothermal Code contains complete requirements for the erection, installation, alteration, addition, repair, relocation, replacement, addition to, use or maintenance of these systems.
Drain Waste and Vent Calculator:
A slide-rule style calculator provides quick and simple access to the fixture unit and sizing tables of Chapter 7 of the UPC.
Water Sizing Calculator: Sizing water systems becomes a much simpler task with the use of this handy slide-rule style calculator.
Natural Gas Pipe Sizing Calculator: This Natural Gas Pipe Sizing Calculator is presented in an easy to use and read slide-rule format. Designed for systems with a supply pressure of six to eight inches of water column, all pipe capacities are given in cubic feet per hour.
Trailer Standards:
IAPMO has developed a number of standards for specialty products used in manufactured homes and recreational vehicles. These standards are available individually, or they may be purchased as a set.
Education and Training Seminars: IAPMO specializes in conducting training and education, including fulfilling continuing education requirements, on the UPC and UMC as well as all of the most commonly utilized codes in the Construction Trades. Special seminars on industry or code subjects are expeditiously created and delivered upon request. Please call to obtain the seminar schedule or to arrange for a custom special seminar.
Backflow Prevention Institute – IAPMO:
The IAPMO Backflow Prevention Institute provides professional education and training for the control of hazards to our water supply and is dedicated to water-system safety worldwide. The Institute provides training in backflow prevention and cross-connection control. This program includes backflow preventers, testers, repairers, cross-connection control surveyors, program administrators and fire-sprinkler backflow preventer testers. Each of these courses provides compliance certification to American Society of Sanitary Engineering (ASSE) Series 5000 Professional Qualification Standards.
Backflow Prevention Reference Manual:
This unique 300-page manual contains full-color illustrations and sections relating to real-world installations, backflow prevention, testing cross-connection control, repair and inspections. The manual is an excellent textbook and a reference the inspectors in every jurisdiction should have access too. It is also an important resource for system designers, urban planners and utility companies – professionals on both sides of the water meter.
ANSI Z 124 Standards:
These standards are written to specifically address a variety of plastic plumbing fixtures and components. They are available individually, or may be grouped for quantity discounts.
IAPMO Installation Standards:
IAPMO standards committees have formulated installation standards for a wide variety of commonly used plumbing materials and systems. The IAPMO installation standards are included after the text of the Uniform Plumbing Code, or can be purchased separately.
xxiv 2025 CALIFORNIA PLUMBING CODE
RELATED PUBLICATIONS AND SERVICES
The Documents Listed are Not by this Reference Adopted by The State of California.
Material and Property Standards: IAPMO does not generally develop material and property standards, but when a need exists the Association will take a leadership role by filling the void. They are available, are subject to amendments and are withdrawn when recognized consensus standards are formulated.
OFFICIAL Magazine: IAPMO’s quarterly publication features informative articles related to Plumbing and Mechanical HVACR installations, award winning general interest features, technical columns and industry updates. Subscriptions are available and all IAPMO members receive a free copy of every issue!
Membership in IAPMO: IAPMO membership is open to all interested persons. Membership categories include Student, Individual, Senior, Organizational and Governmental. Member benefits include discounted prices on IAPMO publications, a subscription to Official magazine, and numerous educational and training opportunities.
HOW TO CONTACT IAPMO
Mailing Address: 4755 East Philadelphia Street, Ontario, California 91761-2816
Main Number: 909-472-4100 • Publication Orders: 800-85-IAPMO • Publication Fax: 877-85-CODES
Website: www.iapmo.org • Office Hours: Monday – Friday, 8am – 5pm Pacific Time
xxvi 2025 CALIFORNIA PLUMBING CODE
TABLE OF CONTENTS
CHAPTER 1 DIVISION I
CALIFORNIA ADMINISTRATION . . . .1
1.1.0 General . . . . . . . . . . . . . . . . . . . . . . .3
1.1.1 Title . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.1.2 Purpose . . . . . . . . . . . . . . . . . . . . . .3
1.1.3 Scope . . . . . . . . . . . . . . . . . . . . . . . .3
1.1.4 Appendices . . . . . . . . . . . . . . . . . . .4
1.1.5 Referenced Codes . . . . . . . . . . . . . .4
1.1.6 Non-Building Standards, Orders, and Regulations . . . . . . . . . . . . . . . .4
1.1.7 Order of Precedence and Use . . . .4
1.1.8 City, County, or City and County Amendments, Additions or Deletions . . . . . . . . . . .4
1.1.9 Effective Date of this Code . . . . . . .5
1.1.10 Availability of Codes . . . . . . . . . . . . .5
1.1.11 Format . . . . . . . . . . . . . . . . . . . . . . .5
1.1.12 Validity . . . . . . . . . . . . . . . . . . . . . . .5
1.2.0 Building Standards Commission . . .5
1.2.1 BSC . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2.2 BSC-CG . . . . . . . . . . . . . . . . . . . . . .6
1.2.3 Alternate Materials, Design, and Methods of Construction
and Equipment . . . . . . . . . . . . . . . . .6
1.3.0 Board of State and Community Corrections . . . . . . . . . . . . . . . . . . . .6
1.3.2 Adopting Agency Identification . . . .7
1.4.0 Department of Consumer Affairs . . .7
1.4.2 Adopting Agency Identification . . . .7
1.5.0 Reserved for California
Energy Commission . . . . . . . . . . . . .7
1.6.0 Department of Food and Agriculture . . . . . . . . . . . . . . . . .7
1.6.2 Adopting Agency Identification . . . .7
1.7.0 Department of Public Health . . . . . .7
1.7.2 Adopting Agency Identification . . . .7
1.8.0 Department of Housing and Community Development . . . . . . . . .7
1.8.1 Purpose . . . . . . . . . . . . . . . . . . . . . .7
1.8.2 Authority and Abbreviations . . . . . . .7
1.8.3 Local Enforcing Agency . . . . . . . . . .8
1.8.4 Permits, Fees, Applications, and Inspections . . . . . . . . . . . . . . . .9
1.8.5 Right of Entry for Enforcement . . . .10
1.8.6 Local Modification by Ordinance or Regulation . . . . . . . .10
1.8.7 Alternate Materials, Designs, Tests, and Methods of Construction . . . . .10
1.8.8 Appeals Board . . . . . . . . . . . . . . . .11
1.8.9 Unsafe Buildings or Structures . . .12
1.8.10 Other Building Regulations . . . . . .12
1.9.0 Division of the State Architect . . . .13
1.9.1 Division of the State Architect – Access Compliance . . . . . . . . . . . .13
1.9.2 Division of the State Architect – Structural Safety . . . . . . . . . . . . . . .13
1.10.0 Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development . . . . . . . . . . . . . .13
1.10.1 OSHPD 1 and OSHPD 1R . . . . . . .13
1.10.2 OSHPD 2 . . . . . . . . . . . . . . . . . . . .13
1.10.3 OSHPD 3 . . . . . . . . . . . . . . . . . . . .14
1.10.4 OSHPD 4 . . . . . . . . . . . . . . . . . . . .14
1.10.5 OSHPD 5 . . . . . . . . . . . . . . . . . . . .14
1.10.6 OSHPD 6 . . . . . . . . . . . . . . . . . . . .15
1.11.0 Office of the State Fire Marshal . . .15
1.11.1 SFM-Office of the
State Fire Marshal . . . . . . . . . . . . .15
1.11.2 Duties and Powers of
the Enforcing Agency . . . . . . . . . . .16
1.11.3 Construction Documents . . . . . . . .18
1.11.4 Fees . . . . . . . . . . . . . . . . . . . . . . . .18
1.11.5 Inspections . . . . . . . . . . . . . . . . . . .19
1.11.6 Certificate of Occupancy . . . . . . . .19
1.11.7 Temporary Structures and Uses . .19
1.11.8 Service Utilities . . . . . . . . . . . . . . . .19
1.11.9 Stop Work Order . . . . . . . . . . . . . .19
1.11.10 Unsafe Buildings, Structures, and Equipment . . . . . . . . . . . . . . . .19
1.11.11 Adopting Agency Identification . . .19
1.12.0 Reserved for the State Librarian . .19
1.13.0 Department of Water Resources (DWR) . . . . . . . . . . . . .19
1.13.1 Application . . . . . . . . . . . . . . . . . . .19
1.13.2 Adopting Agency Identification . . .19
1.14.0 Reserved for the State
Lands Commission . . . . . . . . . . . . .19
CHAPTER 1 DIVISION II
SCOPE AND ADMINISTRATION . .21
101.0 General . . . . . . . . . . . . . . . . . . . . . .21
101.1 Title . . . . . . . . . . . . . . . . . . . . . . . . .21
TABLE OF CONTENTS
101.2 Scope . . . . . . . . . . . . . . . . . . . . . . .21
101.3 Purpose . . . . . . . . . . . . . . . . . . . . .21
101.4 Unconstitutional . . . . . . . . . . . . . . .21
101.5 Validity . . . . . . . . . . . . . . . . . . . . . .21
102.0 Applicability . . . . . . . . . . . . . . . . . . .21
102.1 Conflicts Between Codes . . . . . . . .21
102.2 Existing Installations . . . . . . . . . . . .21
102.3 Maintenance . . . . . . . . . . . . . . . . . .21
102.4 Additions, Alterations, Renovations, or Repairs . . . . . . . . .21
102.5 Health and Safety . . . . . . . . . . . . . .21
102.6 Changes in Building Occupancy . . .21
102.7 Moved Structures . . . . . . . . . . . . . .21
102.8 Appendices . . . . . . . . . . . . . . . . . . .21
103.0 Duties and Powers of the
Authority Having Jurisdiction . . . . .22
103.1 General . . . . . . . . . . . . . . . . . . . . . .22
103.2 Liability . . . . . . . . . . . . . . . . . . . . . .22
103.3 Applications and Permits . . . . . . . .22
103.4 Right of Entry . . . . . . . . . . . . . . . . .22
104.0 Permits . . . . . . . . . . . . . . . . . . . . . .22
104.1 Permits Required . . . . . . . . . . . . . .22
104.2 Exempt Work . . . . . . . . . . . . . . . . .22
104.3 Application for Permit . . . . . . . . . . .22
104.4 Permit Issuance . . . . . . . . . . . . . . .23
104.5 Fees . . . . . . . . . . . . . . . . . . . . . . . .24
105.0 Inspections and Testing . . . . . . . . .24
105.1 General . . . . . . . . . . . . . . . . . . . . . .24
105.2 Required Inspections . . . . . . . . . . .24
105.3 Testing of Systems . . . . . . . . . . . . .25
105.4 Connection to Service Utilities . . . .25
106.0 Violations and Penalties . . . . . . . . .25
106.1 General . . . . . . . . . . . . . . . . . . . . . .25
106.2 Notices of Correction or Violation . . .25
106.3 Penalties . . . . . . . . . . . . . . . . . . . . .26
106.4 Stop Orders . . . . . . . . . . . . . . . . . .26
106.5 Authority to Disconnect Utilities in Emergencies . . . . . . . . .26
106.6 Authority to Condemn . . . . . . . . . . .26
107.0 Board of Appeals . . . . . . . . . . . . . .26
107.1 General . . . . . . . . . . . . . . . . . . . . . .26
107.2 Limitations of Authority . . . . . . . . . .26
Table 104.5 Plumbing Permit Fees . . . . . . . . . .27
CHAPTER 2 DEFINITIONS . . . . . . . . . . . . . . . . .29
201.0 General . . . . . . . . . . . . . . . . . . . . . .31
201.1 Applicability . . . . . . . . . . . . . . . . . . .31
202.0 Definition of Terms . . . . . . . . . . . . .31
202.1 General . . . . . . . . . . . . . . . . . . . . . .31
CHAPTER 3 GENERAL REGULATIONS . . . . . .47
301.0 General . . . . . . . . . . . . . . . . . . . . . .49
301.1 Applicability . . . . . . . . . . . . . . . . . . .49
301.2 Minimum Standards . . . . . . . . . . . .49
301.3 Alternate Materials and Methods
of Construction Equivalency . . . . . .49
301.4 Flood Hazard Areas . . . . . . . . . . . .49
301.5 Alternative Engineered Design . . . .50
301.6 Tall Wood (Mass Timber) Buildings . . . . . . . . . . . . . . . . . . . . .50
321.0 Essential Plumbing Provisions . . . .54¶
322.0 Psychiatric Services . . . . . . . . . . . .54¶
323.0 Plumbing Equipment Schedules . . .55¶
Table 313.3 Hangers and Supports . . . . . . . . . .55
CHAPTER 4 PLUMBING FIXTURES
AND FIXTURE FITTINGS . . . . . . .57
401.0 General . . . . . . . . . . . . . . . . . . . . . .59
401.1 Applicability . . . . . . . . . . . . . . . . . . .59
401.2 Quality of Fixtures . . . . . . . . . . . . .59
613.0 Domestic Hot-Water Distribution¶
Systems for Health Facilities and Clinics . . . . . . . . . . . . . . . . . .161
Table 613.1 Hot Water Use . . . . . . . . . . . . . . . . .161
614.0 Dialysis Water-Distribution¶
Systems . . . . . . . . . . . . . . . . . . . . . .162
615.0 Identification of Potable and¶
Nonpotable Water Lines . . . . . . . . .162
724.0 Meat and Poultry Processing¶
Plant Drainage . . . . . . . . . . . . . . .178
725.0 Collection Center and¶
Facilities Drainage . . . . . . . . . . . .178
726.0 Drainage and Plumbing,¶
General . . . . . . . . . . . . . . . . . . . . .178
101.0 General.¶
102.0 Applicability.¶
103.0 Duties and Powers of the Authority Having¶
Jurisdiction.
104.0 Permits.¶
105.0 Inspections and Testing.¶
106.0 Violations and Penalties.¶
107.0 Board of Appeals.¶
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Plumbing Code (Title 24, Part 5)
▸Chapter 1 — GENERAL CODE PROVISIONS
Overview- 301.7 One- and Two-Family Dwellings . .50
- 301.8 OSHPD 1R . . . . . . . . . . . . . . . . . . .50
- 310.14 Services/Systems and Utilities . . . .52
- 310.15 Telephone and Data
- 401.3 Water-Conserving Fixtures
- 422.8 Cosmetology . . . . . . . . . . . . . . . . .69
- 422.9 Cosmetology Establishments . . . . .69
- 422.10 Commissaries Serving Mobile
- 422.11 Employee Lavatories in
- 501.2 California Energy Code
- 601.4 Schools of Cosmetology and
- 601.5 Meat and Poultry Processing
- 601.6 Collection Centers and
- 601.7 Renderers . . . . . . . . . . . . . . . . . . .139
- 601.8 Horse Meat and Pet Food
- 615.1 Uses Not Permitted . . . . . . . . . . . . .162
- 616.0 Emergency Water Supply . . . . . . . .162
- 717.2 Meat and Poultry Processing
- 727.0 Emergency Sanitary Drainage . . .178
- 1010.2 Meat and Poultry Processing
- 1010.3 Collection Centers and
- 1010.4 Horse Meat and Pet Food
- 1010.5 Draining and Plumbing . . . . . . . .197
- 1211.8 Earthquake-Actuated Gas
- 1501.9 Signage . . . . . . . . . . . . . . . . . . . .310
- 1504.5 Irrigation, Disposal Field and
- 1504.6 Reserved . . . . . . . . . . . . . . . . . . .318
- 1504.7 Reserved . . . . . . . . . . . . . . . . . . .318
- 1505.15 Minimum Water Quality
- 1505.16 Maintenance and Inspection . . . .322
- 101.1 Title. This document shall be known as the “Uniform
- 101.2 Scope. The provisions of this code shall apply to the
- 101.3 Purpose. This code is an ordinance providing minimum req…
- 101.4 Unconstitutional. Where a section, subsection, sentence,…
- 101.5 Validity. Where a provision of this code, or the applica…
- 102.1 Conflicts Between Codes. Where the requirements
- 102.2 Existing Installations. Plumbing systems lawfully
- 102.3 Maintenance. The plumbing and drainage system,
- 102.4 Additions, Alterations, Renovations, or Repairs.
- 102.5 Health and Safety. Where compliance with the provisions …
- 102.6 Changes in Building Occupancy. Plumbing systems that are…
- 102.7 Moved Structures. Parts of the plumbing system of
- 102.8 Appendices. The provisions in the appendices are
- 103.1 General. The Authority Having Jurisdiction shall be
- 103.2 Liability. The Authority Having Jurisdiction charged
- 103.3 Applications and Permits. The Authority Having
- 103.4 Right of Entry. Where it is necessary to make an
- 104.1 Permits Required. It shall be unlawful for a person,
- 104.2 Exempt Work. A permit shall not be required for the
- 104.3 Application for Permit. To obtain a permit, the
- 104.4 Permit Issuance. The application, construction documents…
- 104.5 Fees. Fees shall be assessed in accordance with the
- 105.1 General. Plumbing systems for which a permit is
- 105.2 Required Inspections. New plumbing work and
- 105.3 Testing of Systems. Plumbing systems shall be
- 105.4 Connection to Service Utilities. No person shall
- 106.1 General. It shall be unlawful for a person, firm, or
- 106.2 Notices of Correction or Violation. Notices of
- 106.3 Penalties. A person, firm, or corporation violating a
- 106.4 Stop Orders. Where work is being done contrary to
- 106.5 Authority to Disconnect Utilities in Emergen-
- 106.6 Authority to Condemn. Where the Authority Having Jurisdi…
- 107.1 General. In order to hear and decide appeals of orders,
- 107.2 Limitations of Authority. The Board of Appeals
- Chapter 2 — DEFINITIONS
- Chapter 3 — GENERAL REGULATIONS
- Chapter 4 — PLUMBING FIXTURES AND FIXTURE FITTINGS
- Chapter 5 — WATER HEATERS
- Chapter 6 — WATER SUPPLY AND DISTRIBUTION
- Chapter 7 — SANITARY DRAINAGE
- Chapter 8 — INDIRECT WASTES
- Chapter 9 — VENTS
- Chapter 10 — TRAPS AND INTERCEPTORS
- Chapter 11 — STORM DRAINAGE
- Chapter 12 — FUEL GAS PIPING
- Chapter 13 — HEALTH CARE FACILITIES AND MEDICAL GAS AND MEDICA…
- Chapter 14 — FIRESTOP PROTECTION
- Chapter 15 — ALTERNATE WATER SOURCES FOR NONPOTABLE APPLICATIONS
- Chapter 16 — NONPOTABLE RAINWATER CATCHMENT SYSTEMS
- Chapter 17 — REFERENCED STANDARDS
- Appendix A — RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYS…
- Appendix B — EXPLANATORY NOTES ON COMBINATION WASTE AND VENT S…
- Appendix C — ALTERNATE PLUMBING SYSTEMS
- Appendix D — SIZING STORM WATER DRAINAGE SYSTEMS
- Appendix E — MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL V…
- Appendix F — FIREFIGHTER BREATHING AIR REPLENISHMENT SYSTEMS
- Appendix G — SIZING OF VENTING SYSTEMS
- Appendix H — PRIVATE SEWAGE DISPOSAL SYSTEMS
- Appendix I — INSTALLATION STANDARDS
- Appendix J — COMBINATION OF INDOOR AND OUTDOOR COMBUSTION AND …
- Appendix K — POTABLE RAINWATER CATCHMENT SYSTEMS
- Appendix L — SUSTAINABLE PRACTICES
- Appendix M — PEAK WATER DEMAND CALCULATOR
- Appendix N — IMPACT OF WATER TEMPERATURE ON THE POTENTIAL FOR …
- Appendix O — NON-SEWERED SANITATION SYSTEMS
- Appendix P — PROFESSIONAL QUALIFICATIONS
- Appendix Q — INDOOR HORTICULTURAL FACILITIES
- Appendix R — TINY HOUSES
- Appendix S — ONSITE STORMWATER TREATMENT SYSTEMS