ROOF DECK ATTACHMENT FOR WOOD ROOFS

[BS] C202.1 Roof decking attachment for one- and two- family dwellings. For one- and two-family dwellings, fastening shall be in accordance with Section C202.1.1 or C202.1.2 as appropriate for the existing construction. The diameter of 8d nails shall be not less than 0.131 inch (3 mm) and the length shall be not less than 2 1 /4 inches (57 mm) to qualify for the provisions of this section for existing nails regardless of head shape or head diameter.

[BS] C202.1.1 Sawn lumber or wood plank roofs. Roof decking consisting of sawn lumber or wood planks up to 12 inches (30 cm) wide and secured with not fewer than two nails (minimum size 8d) to each roof framing member it crosses shall be deemed to be sufficiently connected. Sawn lumber or wood plank decking secured with smaller fasteners than 8d nails or with fewer than two nails (minimum size 8d) to each framing member it crosses shall be deemed sufficiently connected if fasteners are added such that two clipped head, round head or ring shank nails (minimum size 8d) are in place on each framing member the nail crosses.

[BS] C202.1.2 Wood structural panel roofs For roof decking consisting of wood structural panels, fasteners and spacings required in Table C202.1.2 shall be deemed to comply with the requirements of Section 706.3.

Supplemental fasteners as required by Table C202.1.2 shall be 8d ring shank nails with round heads and the following minimum dimensions:

  1. 0.113-inch-nominal (3 mm) shank diameter.
  2. Ring diameter not less than 0.012 inch (0.3 mm) greater than shank diameter.
  3. 16 to 20 rings per inch.
  4. A minimum 0.280-inch (7 mm) full round head diameter.
  5. Ring shank to extend not less than 1 1 /2 inches (38 mm) from the tip of the nail.
  6. Minimum 2 1 /4-inch (57 mm) nail length.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

APPENDIX C—GUIDELINES FOR THE WIND RETROFIT OF EXISTING BUILDINGS

[BS] TABLE C202.1.2 SUPPLEMENT FASTENERS AT PANEL EDGES AND INTERMEDIATE FRAMING

EXISTING FASTENERS EXISTING FASTENER
SPACING (EDGE OR
INTERMEDIATE
SUPPORTS)
MAXIMUM SUPPLEMENTAL
FASTENER SPACING FOR
130 MPH < V ≤ 140 MPH
ult
MAXIMUM SUPPLEMENTAL
FASTENER SPACING FOR
INTERIOR ZONEc LOCATIONS
FOR MPH V > 140 MPH AND
ult
EDGE ZONES NOT COVERED
BY THE COLUMN TO THE
RIGHT
EDGE ZONEd FOR V > 160
ult
MPH AND EXPOSURE C, OR
V > 180 MPH AND
ult
EXPOSURE B
Staples or 6d Any 6″ o.c.b 6″ o.c.b 4″ o.c.b at panel edges and
4″ o.c.b at intermediate sup-
ports
8d clipped head or round head
smooth shank
6″ o.c. or less None necessary None necessary along
edges of panels but 6″ o.c.b
at intermediate supports of
panel
4″ o.c.a at panel edges and
4″ o.c.a at intermediate sup-
ports
8d clipped head or round head
ring shank
6″ o.c. or less None necessary None necessary 4″ o.c.a at panel edges and
4″ o.c.a at intermediate sup-
ports
8d clipped head or round head
smooth shank
Greater than 6″ o.c. 6″ o.c.a 6″ o.c.a along panel edges
and 6″ o.c.b at intermediate
supports of panel
4″ o.c.a at panel edges and
4″ o.c.a at intermediate sup-
ports
8d clipped head or round head
ring shank
Greater than 6″ o.c. 6″ o.c.a 6″ o.c.a 4″ o.c.a at panel edges and
4″ o.c.a at intermediate sup-
ports

For SI: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. a. Maximum spacing determined based on existing fasteners and supplemental fasteners. b. Maximum spacing determined based on supplemental fasteners only. c. Interior zone = sheathing that is not located within 4 feet of the perimeter edge of the roof or within 4 feet of each side of a ridge. d. Edge zone = sheathing that is located within 4 feet of the perimeter edge of the roof and within 4 feet of each side of a ridge.

APPENDIX C-26 2022 CALIFORNIA EXISTING BUILDING CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.