J104.3 Replace the exception as follows:

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

J104.3 Replace the exception as follows:

Exception: [ ] Grading conforming to all of the following requirements:

  1. No cut section is greater than 10 feet (3.048 m) in vertical height.

  2. No cut slope is steeper than 2 horizontal to 1 vertical.

  3. The tops of cut banks are separated from any structure or major improvement by a distance, measured horizontally, equal to not less than the height of the bank.

  4. Not more than 5,000 cubic yards (3825 m [3] ) shall be involved in grading.

  5. Grading performed at a site outside the limits of known slide areas.

All other grading shall require soils report and the grading plans shall include, but not limited to, the following information:

(1) The design of retaining walls or other structures used to support cuts or fills. Such retaining walls or structures, except when part of a building, may be constructed under this permit, provided the cost of same is included in the valuation shown on the application.

(2) The sequencing of cut and fill operations in a manner that assures interim stability of the site.