Section 701.0 — GENERAL

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

701.2(2)(a) Revise this section as follows:

701.2(2)(a) ABS and PVC installations are limited to not more than two stories of areas of commercial or private residential accommodations.

701.2(3) Revise this section as follows:

701.2(3) No vitrified clay pipe or fittings shall be used aboveground or where pressurized by a pump or ejector or underground within the foundation line of the building. They shall be kept not less than 12 inches (305 mm) belowground.

701.2(7) Add the following section:

701.2(7) Copper tubing shall not be used for urinal drainage or applications which are detrimental to the integrity of copper tubing.