Section 504C — SYMBOLS AND NOTATIONS

504C.1 For the purpose of this chapter, the applicable symbols and notations in this code shall apply.

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

504C.1 For the purpose of this chapter, the applicable symbols and notations in this code shall apply.

A = cross sectional area of unreinforced masonry pier or wall, square inches.

Ab = total area of the bed joints above and below the test specimen for each in-place shear test.

Cp = numerical coefficient as specified in Table 5C-C for Special Procedure diaphragm shear transfer.

D = in-plane width dimension of pier, inches, or depth of diaphragm, feet.

DCR = demand-capacity ratio specified in Section 511C.4.2.

Fwx = force applied to a wall at level x, pounds.

H = least clear height of opening on either side of a pier, inches.

h/t = height-to-thickness ratio of an unreinforced masonry wall. Height, h, is measured between wall anchorage levels and/or slab-on-grade.

L = span of diaphragm between shear walls, or span between shear wall and open front, feet.

Lo = length of crosswall, feet.

Li = effective span for an open front building specified in Section 511C.8, feet.

PD = superimposed dead load at the location under consideration, pounds. For determination of the rocking shear capacity, dead load at the top of the pier under consideration shall be used.

PD+L = stress resulting from the dead plus actual live load in place at the time of testing, pounds per square inch (psi).

Pw = weight of wall, pounds.

Va = vaA, the allowable shear in any unreinforced masonry pier, pounds.

Vca = total shear capacity of crosswalls in the direction of analysis immediately above the diaphragm level being investigated, åvcLo, pounds.

Vcb = total shear capacity of crosswalls in the direction of analysis immediately below the diaphragm level being investigated, åvcLo, pounds.

Vp = shear force assigned to a pier on the basis of its relative shear rigidity, pounds.

Vr = pier rocking shear capacity of any unreinforced masonry wall or wall pier, pounds.

Vtest = load at incipient cracking for each in-place shear test per Section 514C, pounds.

Vwx = total shear force resisted by a shear wall at the level under consideration, pounds.

va = allowable shear stress for unreinforced masonry, pounds per square inch (psi).

vc = allowable shear value for a crosswall sheathed with any of the materials given in Table 5C-D or 5C-E, pounds per foot.

vt = mortar shear strength as specified in Section 506C.3.3.4, pounds per square inch (psi).

vto = mortar shear test values as specified in Section 506C.3.3.4, pounds per square inch (psi).

vu = allowable shear value for a diaphragm sheathed with any of the materials given in Table 5C-D or 5C-E, pounds per foot.

ΣvuD = sum of diaphragm shear capacities of both ends of the diaphragm, pounds.

ΣΣvuD = for diaphragms coupled with crosswalls, ΣΣvuD includes the sum of shear capacities of both ends of diaphragms coupled at and above the

level under consideration.

W = total seismic dead load as defined in San Francisco Building Code Chapter 16, pounds.

Wd = total dead load tributary to a diaphragm, pounds.

Σwd = total dead load to all the diaphragms at and above the level under consideration, pounds.

Ww = total dead load to an unreinforced masonry wall above the level under consideration or above an open front building, pounds.

W w x = dead load of an unreinforced masonry wall assigned to Level x halfway above and below the level under consideration, pounds.