Part II — Codes Adopted and Amended

Placer County Planning Code · 2026-07 edition · updated 2026-07-25 · Placer County

§ 15.04.210. Adoption of the California Building Standards Code.

The following parts of the 2025 Triennial Edition of Title 24, California Code of Regulations (CCR), are hereby adopted by reference and incorporated in this code, except as expressly amended or superseded by the provisions of this code:

Part 2 - California Building Code, Part 2.5 - California Residential Code, Part 3 - California Electrical Code, Part 4 - California Mechanical Code, Part 5 - California Plumbing Code, Part 6 - California Energy Code, Part 7 - California Wildland-Urban Interface Code, Part 8 - California Historical Building Code, Part 9 - California Fire Code, Part 10 - California Existing Building Code, Part 11 - California Green Building Standards Code (CALGreen Code), Part 12 - California Referenced Standards Code. (Ord. 6345-B, 11/18/2025)

§ 15.04.220. Building Code adopted.

The California Building Code, 2025 Edition (California Code of Regulations Title 24, Part 2), based on the 2021 International Building Code, is hereby adopted, as are Appendix C (Group U - Agricultural Buildings) and Appendix J (Grading) thereto. (Ord. 6345-B, 11/18/2025)

§ 15.04.230. Building Code amended.

The California Building Code adopted in Section 15.04.220 is modified, amended and/or supplemented as set out in Sections 15.04.240 through 15.04.320. (Ord. 6345-B, 11/18/2025)

§ 15.04.240. Definitions.

Section 202 - Definitions. Add the following to Section 202 of the CBC:

Bedroom: A room that meets the minimum dimension, area, and height requirements for a habitable room as specified in California Building Code Section 1208 and that has an adjoining area or space that may be utilized as a closet intended for clothes storage. (Ord. 6345-B, 11/18/2025)

§ 15.04.250. Outdoor lights - Serene Lakes.

Section 312 - Utility and Miscellaneous Group U. Add the following subsection to Section 312 of the CBC:

Section 312.2 - Outdoor lights in Serene Lakes. Any garage constructed after March 1, 1985, in the Serene Lakes subdivision will be required to provide an exterior light installed on the street side of the garage. This light shall be controlled by a photocell and shall be in operation between the months of November through March.

§ 15.04.260. Building addresses.

Section 502.1 - Address identification. Replace Section 502.1 of the CBC with the following

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.260

§ 15.04.290

section:

Section 502.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Whenever the address on the building is not clearly visible from the public street or access road fronting the property, the address shall also be placed at the public street or access road in a manner which is clearly visible from both directions of travel on the frontage road or street. When necessary to facilitate emergency response, the address shall be posted in additional locations, such as a fork in a driveway serving more than one residence. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Numbers and letters shall be a minimum four-inch letter height, onehalf inch stroke width, reflectorized, and contrast with their background; or a minimum fiveinch letter height, one-half inch stroke width, and contrast with their background. Address identification shall be maintained.

(Ord. 6345-B, 11/18/2025)

§ 15.04.270. Efficiency dwelling units.

Section 1208.4 - Efficiency dwelling units. Replace item 1 of Section 1208.4 of the CBC as follows:

  • A. The unit shall have a living space with a minimum floor area of not less than 150 square feet. An additional 100 square feet (9.3 m2) of floor area shall be provided for each occupant of such unit in excess of two.

  • (Ord. 6345-B, 11/18/2025)

§ 15.04.280. Weather protection.

Section 1503.6 - Building Exit Protection. Add Section 1503.6 to the CBC:

Where Pg is 90 pounds per square foot or greater, all required building exits, the exit discharge, and decks shall be designed and protected or located where not subject to sliding or impact snow and ice nor shall the building shed snow or permit the sliding of snow onto an adjoining structure. "All building exits" shall mean all required exits in single family dwellings and appurtenant structures, and all building exits in all other occupancies.

Section 1507.1.2 - Ice Barriers. Replace Section 1507.1.2 of the CBC with the following:

Section 1507.1.2 - Ice Barriers. Where Pg is 150 pounds per square foot or greater, an ice barrier is required for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, and wood shakes. The ice barrier shall consist of not less than two layers of underlayment cemented together, or a self-adhering polymer modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edges of all roof surfaces to a point not less than 24 inches inside the exterior wall line of the building.

Exception: Detached accessory structures that do not contain conditioned floor area. (Ord. 6345-B, 11/18/2025)

§ 15.04.290. Snow and wind design.

Section 1608 - Snow loads.

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA § 15.04.290

PLACER COUNTY CODE

§ 15.04.290

Section 1608.1 - General. Add the following to Section 1608.1 of the CBC:

Buildings or structures will not be permitted in high or moderate hazardous areas, such as sites prone to avalanche, flood, and mudslide, or other designated hazardous areas, as identified by Placer County Code, Chapter 15 or Chapter 12, Article 12.40, unless an architect, civil or structural engineer licensed in California has certified that the structure will be safe under the anticipated hazards, and the structure complies with anticipated loads and conditions. See Placer County Code, Chapter 12, Article 12.40 for exemptions from the avalanche standards.

Section 1609 - Wind loads.

Section 1609.3 - Basic design wind speed. Replace figures 1609.3(1), 1609.3(2), and 1609.3(3) of the CBC with the following tables:

==> picture [424 x 111] intentionally omitted <==

----- Start of picture text -----
Table 1609.3(1)
ELEVATION ABOVE MEAN SEA LEVEL BASIC WIND SPEED (V)
Up to 5,000 feet See note
5,001 to 7,000 feet 118 mph
7,001 to 8,000 feet 127 mph
8,001 and Up 136 mph
----- End of picture text -----

The basic design wind speed for Risk Category I Buildings and Other Structures shall be per Table 1609.3(1). Risk Category I and II Buildings and Other Structures below 5,000 foot elevation shall use ASCE 7 Hazard tool.

*Values are nominal design 3-second gust wind speeds at 33 ft. above ground for Exposure C.

==> picture [424 x 111] intentionally omitted <==

----- Start of picture text -----
Table 1609.3(2)
ELEVATION ABOVE MEAN SEA LEVEL BASIC WIND SPEED (V)
Up to 5,000 feet See note
5,001 to 7,000 feet 130 mph
7,001 to 8,000 feet 140 mph
8,001 and Up 150 mph
----- End of picture text -----

The basic design wind speed for Risk Category II Buildings and Other Structures shall be per Table 1609.3(2). Risk Category I and II Buildings and Other Structures below 5,000 foot elevation shall use ASCE 7 Hazard tool.

  • Values are nominal design 3-second gust wind speeds at 33 ft. above ground for Exposure C.

==> picture [424 x 111] intentionally omitted <==

----- Start of picture text -----
Table 1609.3(3)
ELEVATION ABOVE MEAN SEA LEVEL BASIC WIND SPEED (V)
Up to 5,000 feet 105 mph
5,001 to 7,000 feet 136 mph
7,001 to 8,000 feet 146 mph
8,001 and Up 157 mph
----- End of picture text -----

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.290

§ 15.04.310

The basic design wind speed for Risk Category III & IV Buildings and Other Structures shall be per Table 1609.3(3).

  • Values are nominal design 3-second gust wind speeds at 33 ft. above ground for Exposure C.

§ 15.04.295. Preservative-treated wood—Structural supports.

Section 2304.12.2.3 Supporting member for permanent appurtenances. Replace Section 2304.12.2.3 of the CBC with the following section:

Naturally durable or preservative-treated wood shall be utilized for those portions of wood members that form the structural supports of building, balconies, porches or similar permanent building appurtenances where such members are exposed to the weather without adequate protection from a roof, eave, overhang, or other covering to prevent moisture or water accumulation on the surface or at joints between members. Deck ledger details shall be a minimum of 2-inch by 8-inch nominal (51 mm by 203 mm), pressure-preservative-treated Southern pine, incised pressure-treated-preservative-treated hem-fir, or approved, naturally durable, No. 2 grade or better lumber. Deck ledgers shall not support concentrated loads from beams or girders. Deck ledgers shall not be supported on stone or masonry veneer.

Exception: Sawn lumber for deck framing in buildings located above 5,000 foot elevation may preclude the need to use durable materials when the project engineer provides on the plans a mitigating measure to provide equal protection of the deck framing as described above. (Ord. 6345-B, 11/18/2025)

§ 15.04.300. Soil types - Conventional construction.

Section 2308.1.1 - Portions exceeding limitations of conventional light-frame construction. Add the following to Section 2308.1.1 of the CBC:

Structures which otherwise qualify for conventional construction may utilize soil profile types C or D based on the design professionals' assessment of the site in combination with public record maps, such as maps from the California Geological Survey. This does not apply where a soils report identifies conditions sufficient to classify the site as E or F as defined in the 2025 CBC and CRC.

(Ord. 6345-B, 11/18/2025)

§ 15.04.310. Roof construction and fire-retardant requirements.

Section 1505 - Fire Classification. Add the following to Section 1505.1 of the CBC:

Class A rating shall be the minimum roofing assembly in the unincorporated portions of Placer County. This requirement includes all occupancies, including Group R, Division 3, and Group U Occupancies.

All new construction, including additions, requires a Class A roofing assembly as a minimum. All reroofing requires Class A as a minimum. Re-roofing in excess of 50% of an existing structure within any one-year period will necessitate that the entire roof be a Class A roofing assembly as a minimum.

Covered photovoltaic modules/shingles authorized by Section 1507.17 that are part of the roof assembly are required to have a minimum Class A listed roof rating and be installed per the

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA § 15.04.310

PLACER COUNTY CODE

§ 15.04.320 listing, consistent with all other types of finished roofing materials.

The local fire authority having jurisdiction may have different requirements when adopted and enforced by the fire district pursuant to Health and Safety Code Section 13869.7.

Provisions in Chapter 15 of the CBC which provide for less stringent roof ratings are not applicable.

(Ord. 6345-B, 11/18/2025)

§ 15.04.320. Residential swimming pool and spa barriers.

Section 3109.2 - California swimming pool safety act (statewide). Amend CBC Section 3109.2 as follows:

115922.

  • (a) Except as provided in Section 115925, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with:

    1. An enclosure that meets the requirements of Section 115923, including but not limited to, a perimeter property fence; and

    2. One of the following drowning prevention safety features:

      • a. Removable mesh fencing that meets the ASTM International F2286 standard in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device.

      • b. A manually operated or power-operated safety pool cover that is accompanied by a label verifying that the cover meets the specifications of the ASTM International F1346-23 standard.

      • c. Exit alarms on the private single-family home's doors and windows that provide direct access to the swimming pool or spa without any intervening enclosure. Whenever any door or window is opened or left ajar, exit alarms shall make either an audible, continuous alarm sound or a repeating verbal warning, such as a notification that "the door to the pool is open." An exit alarm may be battery operated or connected to the electrical wiring of the building.

      • d. A self-closing, self-latching device with a release mechanism placed no lower than 54 inches above the floor on the private single-family home's doors providing direct access to the swimming pool or spa.

      • e. An alarm in good repair and operable as designed that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM International F2208 standard that includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.320

§ 15.04.350

  - f. Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features set forth above and has been independently verified by an approved testing laboratory as meeting standards for those features established by ASTM International, the American Society of Mechanical Engineers, or another nationally recognized standards development organization, and the feature is accompanied by a label verifying that the protection meets those standards. 
  • (b) The requirements of subdivision (2) are not satisfied by any of the following:

    1. An exit alarm and a self-closing, self-latching device on the same door.
  1. An exit alarm and a door latch on separate doors.

    1. A safety pool cover and an alarm described in paragraph (6) of subdivision (a).
  • (c) Before the issuance of a final approval for the completion of permitted construction or remodeling work, the local building code official shall inspect the drowning safety prevention features required by this section and, if no violations are found, shall give final approval.

Exception:

Where swimming pools are located 100 feet or more from the nearest property line on a minimum 3-acre parcel, a pool enclosure meeting the requirements of Section 115923 shall not be required. The swimming pool shall be provided with a minimum of (2) drowning prevention measures, as required by Section 115922.

Section 3109.2 - California Swimming Pool Safety Act (statewide). Add the following subdivisions to Section 3109.2 of the CBC:

    1. Any gates other than pedestrian access gates shall be equipped with lockable hardware or padlocks and shall remain locked at all times when not in use. A permanent sign shall be posted which reads: "This access to be kept locked at all times."
    1. Driveway gates that are part of the enclosure are to be electronically operated and automatically close within one minute of being opened.
  • (Ord. 6345-B, 11/18/2025)

§ 15.04.330. Residential Code adopted.

The California Residential Code, 2025 Edition (California Code of Regulations Title 24, Part 2.5), based on the 2024 International Residential Code, is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.340. Residential Code amended.

The California Residential Code adopted in Section 15.04.330 is modified, amended and/or supplemented as set out in Sections 15.04.350 through 15.04.380. (Ord. 6345-B, 11/18/2025)

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.350

§ 15.04.360

§ 15.04.350. Definitions.

Section R202 - Definitions. Add the following to Section R202 of the CRC:

Bedroom: A room that meets the minimum dimension, area, and height requirements for a habitable room, as specified in the California Residential Code Sections R312 and R313, that has an adjoining area or space that may be utilized as a closet intended for clothes storage. (Ord. 6345-B, 11/18/2025)

§ 15.04.360. Building planning.

Section R301 - Design criteria.

Section R301.1 - Application. Add the following to Section R301.1 of the CRC:

Buildings or structures will not be permitted in high or moderate hazardous areas, such as sites prone to avalanche, flood, and mudslide, or other designated hazardous areas, as identified by Placer County Code, Chapter 15 or Chapter 12, Article 12.40, unless an architect, civil or structural engineer licensed in California has certified that the structure will be safe under the anticipated hazards, and the structure complies with anticipated loads and conditions. See Placer County Code, Chapter 12, Article 12.40 for exemptions from the avalanche standards.

Table R301.2 Climatic and Geographic Design Criteria. Replace CRC Table R301.2 with the following Table:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.360

§ 15.04.360

==> picture [722 x 179] intentionally omitted <==

----- Start of picture text -----
Design Criteria
Table R 301.2(1)
Climatic and Geographic Design Criteria
WIND DESIGN SUBJECT TO
Speed Wind
(mph, Special borne Seismic Ice Barrier Mean Ground
exposure Topographic wind debris Design Frost Line Winter Underlayment Flood Air Freezing Annual Snow
c) effect region zone Category Weathering Depth Termite Design Temp Required Hazards Index Temp Load
PER GIS1 95 NO NO NO D** Negligible NA YES VARIES NO FEMA 1500 63.5
PER GIS2 130
YES YES NO D
Severe 24"/18"
** YES VARIES YES FEMA 1500 45.25 ****
----- End of picture text -----

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.360

§ 15.04.360

1 Roseville - Roseville/Auburn service area.

2 Truckee - Truckee/Tahoe service area.

  • 130 mph: 5,001'-7,000' Risk Category II

  • 140 mph: 7,001'-8,000' Risk Category II

150 mph: 8,001' and up Risk Category II

  • ** See notes below for site specific selection of seismic design category.

  • *** Exterior frost line depth: 24", and Interior frost line depth: 18" for areas above 5,000'.

**** See notes below for site specific selection of ground snow load.

==> picture [424 x 362] intentionally omitted <==

----- Start of picture text -----
Joint Appendix 2.2, Table 2-3 Design Day Data for California Cities Climate Zone 11 (Roseville, CA)
Latitude Mean Interior Design
Degrees Winter Summer Coincident design temperature Daily
Elevation Feet North Heating Cooling wet bulb temperature cooling Range HDD
160 38.7 24 100 70 68 75 36 0
Climate Zone 16 (Truckee, CA)
Elevation Feet Latitude Winter Summer Mean Interior Design Daily HDD
Degrees Heating Cooling Coincident design temperature Range
North wet bulb temperature cooling
5995 39.3 -10 86 57 68 75 40 8230
Notes:
1. The above climate data for Roseville and Truckee generally cover the major population centers for Placer County in
each Climate Zone. For climate data for other locations, refer to Title 24, Part 6, 2025 California Energy Code, Joint
Appendix 2.2, Table 2-3 Design Criteria. The 2025 California Energy Code Joint Appendices may be found here:
https://www.energy.ca.gov/sites/default/files/2025-07/CEC-400-2025-010-AP.pdf
2. Outdoor design conditions are based on data from the 2021 ASHRAE Handbook, Chapter 14: Climatic Design
Information.
3. Indoor design conditions for sizing space condition systems are found in the 2025 California Energy Code, Section
150.0(h)2.
4. HDD - Heating Degree Day is a unit, based on temperature difference and time, used in estimating fuel consumption
and specifying nominal annual heating load of a building. For any one day when the mean temperature is less than
65°F (18°C), there exist as many degree days as there are Fahrenheit degrees difference in temperature between
mean temperature for the day and 65° F (18°C).
----- End of picture text -----

Note: HVAC indoor design temperatures shall be 68° F for heating (minimum) and 75° F for cooling. Outdoor design temperatures for heating shall be no lower than the Heating Winter Median of Extremes values. The outdoor design temperatures for cooling shall be no greater than the 1.0 percent Cooling Dry Bulb and Mean Coincident Wet Bulb values.

Section R301.2(2) - Ultimate Design Wind Speeds. Add the following to Section R301.2.1 of the CRC:

The ultimate wind speed* for Placer County shall be as follows:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.360

§ 15.04.360

==> picture [424 x 105] intentionally omitted <==

----- Start of picture text -----
ULTIMATE WIND SPEED
ELEVATION ABOVE MEAN SEA LEVEL (V)
Up to 5,000 feet See note
5,001 to 7,000 feet 130 mph
7,001 to 8,000 feet 140 mph
8,001 and Up 150 mph
----- End of picture text -----

Notes:

  • Values are nominal design 3-second gust wind speeds at 33 ft. above ground for Exposure C.

Risk Category I and II Buildings and Other Structures below 5,000 foot elevation shall use ASCE 7 Hazard tool.

Section R301.2.3 - Snow loads.

Section R301.2.3 - Snow Loads. Amend Section R301.2.3 of the CRC as follows:

Ground snow loads shall be determined in accordance with Figure R301.2(3), ASCE 7 Hazard Tool, or in accordance with Section 1608 of the California Building Code. Wood-framed construction, cold-formed, steel-framed construction and masonry and concrete construction, and structural insulated panel construction in regions with allowable stress design ground snow loads, Pg(asd) 50 pounds per square foot or less, shall be in accordance with Chapters 5, 6, and 8. Buildings in regions with allowable stress design ground snow loads, Pg(asd), greater than 50 pounds per square foot shall be designed in accordance with accepted engineering practice.

Where Pg is 90 pounds per square foot or greater, all required building exits, the exit discharge, and decks shall be designed and protected or located where not subject to sliding or impact snow and ice nor shall the building shed snow or permit the sliding of snow onto an adjoining structure. "All building exits" shall mean all required exits in single family dwellings and appurtenant structures, and all building exits in all other occupancies.

Section R304 - Minimum room areas. Add the following subsection to Section R304 of the CRC:

Section R304.4 - Efficiency dwelling units. Efficiency dwelling units shall comply with the following:

  1. The unit shall have a living space with a minimum floor area of not less than one hundred fifty (150) square feet. An additional 100 square feet (9.3 m2) of floor area shall be provided for each occupant of such unit in excess of two.

  2. The unit shall be provided with a separate closet.

  3. The unit shall be provided with a kitchen sink, functioning cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided.

  4. The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower.

Section R304 - Protection of Wood and Wood-Based Products Against Decay.

Section R304.1 - Location Required. Replace Item 8, Exception with the following:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA § 15.04.360

PLACER COUNTY CODE

§ 15.04.380

Exception: Sawn lumber for deck framing in buildings located above 5,000 foot elevation may preclude the need to use durable materials when the project engineer provides on the plans a mitigating measure to provide equal protection of the deck framing as described above.

Section R308 - Address identification.

Section R308.1 - Address identification. Replace Section R308.1 of the CRC with the following section:

New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Whenever the address on the building will not be clearly visible from the public street or access road fronting the property, the address shall also be placed at the public street or access road in a manner which is clearly visible from both directions of travel on the frontage road or street. When necessary to facilitate emergency response, the address shall be posted in additional locations, such as a fork in a driveway serving more than one residence. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Numbers and letters shall be a minimum four-inch letter height, one-half inch stroke width, reflectorized, and contrast with their background; or a minimum five-inch letter height, one-half inch stroke width, and contrast with their background. Address identification shall be maintained.

Section R309 - Automatic Sprinkler Systems.

Section R309.3.2.3 - Freezing areas. Add the following to Section R309.2.3 of the CRC:

Systems utilizing glycerin shall not exceed 50% concentration; systems using propylene glycol shall not exceed a 40% concentration or as recommended by the California State Fire Marshal's Office.

Section R317 - Garages and carports.

Section R317.9 - Outdoor lights in Serene Lakes. Add the following subsection to Section R317 of the CRC:

Any garage constructed after March 1, 1985, in the Serene Lakes subdivision will be required to provide an exterior light installed on the street side of the garage. This light shall be controlled by a photocell and shall be in operation between the months of November through March. (Ord. 6345-B, 11/18/2025)

§ 15.04.370. Foundations.

Section R401.1 - Application. Add the following to Section R401.1 of the CRC:

A one-story wood or metal framed building located within any seismic design category not used for human occupancy and not over 400 square feet in floor area may be constructed with walls supported on a wood foundation plate or slab not less than three and one-half inches. Provisions to address uplift shall be included in the submittal. (Ord. 6345-B, 11/18/2025)

§ 15.04.380. Residential roof construction and fire-retardant requirements.

Section, R902 - Fire Classification. Add the following to Section, R902.1 of the CRC:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.380

§ 15.04.430

Section R902.1 - Roofing covering materials. Add the following to Section R902.1 of the CRC:

  • a. Class A rating shall be the minimum roofing assembly in the unincorporated portions of Placer County. This requirement includes Group R, Division 3, and Group U Occupancies.

  • b. All new construction, including additions, requires a Class A roof assembly as a minimum. All reroofing requires a Class A as a minimum. Re-roofing in excess of 50% of an existing structure within any one-year period will necessitate that the entire roof be provided with a Class A roof assembly.

  • c. Photovoltaic modules/shingles that are part of the roof assembly are required to have a minimum Class A listed roof rating and be installed per the listing, consistent with all other types of finished roofing materials.

The local fire authority having jurisdiction may have different requirements when adopted and enforced by the fire district pursuant to Health and Safety Code Section 13869.7.

Provisions in CBC Chapter 15 and CRC Chapter 9 which provide for less stringent roof ratings are not applicable.

Section R905.1.2 - Ice Barriers. Replace Section R905.1.2 with the following:

R905.1.2 Ice Barriers. Where Pg is 150 pounds per square foot or greater, an ice barrier is required for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, and wood shakes. The ice barrier shall consist of not less than two layers of underlayment cemented together, or a self-adhering polymer modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edges of all roof surfaces to a point not less than 24 inches inside the exterior wall line of the building.

Exception: Detached accessory structures that do not contain conditioned floor area. (Ord. 6345-B, 11/18/2025)

§ 15.04.400. Electrical Code adopted.

The California Electrical Code (CEC), 2025 Edition (California Code of Regulations Title 24, Part 3), based on the 2023 National Electrical Code, is hereby adopted, including reference Annex C.

(Ord. 6345-B, 11/18/2025)

§ 15.04.410. Electrical Code amended.

The California Electrical Code (CEC) adopted in Section 15.04.400 is modified, amended and/ or supplemented as set out in Sections 15.04.420 through 15.04.440. (Ord. 6345-B, 11/18/2025)

§ 15.04.420. Requirements for electrical installations.

Section 110.1 - Scope. Add the following to Section 110.1 of the CEC:

The chief building official may withhold or disconnect power from any dangerous building, as defined in the Placer County Code, or due to other hazardous condition(s). (Ord. 6345-B, 11/18/2025)

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.430

§ 15.04.480

§ 15.04.430. Working space and access.

Section 110.26 - Spaces about electrical equipment; Section 110.32 - Work space about equipment; and Section 240.24(A) - Accessibility. Add the following to Sections 110.26, 110.32, and 240.24(A) of the CEC:

In locations above 3,500 foot elevation, covered protection shall be provided for the main service panel to maintain a readily accessible path to the service panel.

Exception: Where all of the over-current protection devices, except the main disconnect at the service panel, are located inside, in a readily accessible location, in a sub panel installed in accordance with this code.

(Ord. 6345-B, 11/18/2025)

§ 15.04.440. Temporary power.

Section 590.1 - Scope. Add the following to Section 590.1 of the CEC:

Temporary electrical service may be authorized only during periods of construction or repair of a structure for which a valid permit has been issued, or where the conditions of approval only authorize temporary service.

(Ord. 6345-B, 11/18/2025)

§ 15.04.450. Mechanical Code adopted.

The California Mechanical Code and appendices, 2025 Edition (California Code of Regulations Title 24, Part 4), based on the 2024 Uniform Mechanical Code, is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.460. Plumbing Code adopted.

The California Plumbing Code (CPC) and appendices, 2025 Edition (California Code of Regulations Title 24, Part 5), based on the 2024 Uniform Plumbing Code, is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.470. Plumbing Code amended.

The California Plumbing Code adopted in Section 15.04.460 is modified, amended and/or supplemented as set out in Section 15.04.480. (Ord. 6345-B, 11/18/2025)

§ 15.04.480. Plumbing requirements in snow areas.

Section 301.2 - Minimum standards. Add the following to Section 301.2 of the CPC:

All new gas installations shall have equipment listed and approved for the conditions of anticipated use. Where exposed to snow and ice, the equipment shall be listed for those conditions. Placer County Building Services Division does not regulate the installation of liquefied petroleum gas (LPG) tanks; however, location of LPG tanks shall be in accordance with the California Mechanical Code, the California Fire Code, and all requirements of the local fire department and/or the State Fire Marshal. Until fire districts adopt approved standards, the requirements in Placer County Code, Chapter 15, Articles 15.12 and 15.16 or NFPA Pamphlet

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.480

§ 15.04.500

58, at the discretion of the fire chief, are enforceable by the fire chiefs in areas above 5,000 foot elevation.

All gas meters, valves, and equipment shall be protected from sliding, drifting, and impact snow and ice. There shall be a gas shut off valve at each structure supplied with gas that is on the outside of the building and is readily accessible at all times. At locations above 3,500 foot elevation, there shall be a sign directly above the shut off valve which is readily visible and located above the maximum anticipated snow depth.

At or above 5,000 foot elevation, water supply piping shall be protected from freezing by a minimum of 36 inches of earth covering or equivalent insulation. Piping which is subject to freezing shall not be installed in unheated areas or outside walls. Exception: In walls or floors adjacent to heated areas when the structural design necessitates, piping may be installed within the assembly on the heated side of at least R-19 insulation.

The water supply system, including hot and cold, shall be designed and installed for winterization and freeze protection, such as allowing for routine drainage of the system to prevent freezing. The water supply shall be equipped with a readily accessible shut-off valve. Valve(s) and/or drain port(s) when used shall be readily accessible, insulated for protection from freezing, and shall be protected from the potential for back flow.

Section 906 - Vent termination. Add the following subsection to Section 906 of the CPC:

Section 906.8 - Vent protection. At elevations above 4,000 feet, all plumbing vents, B-vents, chimneys, and miscellaneous obstructions projecting through the roof shall be protected from damage by sliding snow or ice. These conditions apply whenever the roof slope is three units vertical to 12 units horizontal (25% slope) or greater, except for those projections within 36 inches of the ridge. This shall be accomplished by using guys, formed metal guards ("Crickets"), saddles, or other methods approved by the chief building official. (Ord. 6345-B, 11/18/2025)

§ 15.04.490. Energy Code adopted.

The California Energy Code, 2025 Edition (California Code of Regulations Title 24, Part 6), as published by the International Code Council (ICC), is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.495. Wildland-Urban Interface Code adopted.

The California Wildland-Urban Interface Code, 2025 Edition (California Code of Regulations, Title 24, Part 7), as published by the International Code Council (ICC), is hereby adopted.

Chapters 1, 2, and 5 of the California Wildland-Urban Interface Code to be enforced by the Placer County Building Services Division.

Chapters 3, 4, 6, 7, and Appendices of the California Wildland-Urban Interface Code to be enforced by Placer County Fire or the Fire District having jurisdiction. (Ord. 6345-B, 11/18/2025)

§ 15.04.500. Wildland-Urban Interface Code amended.

The California Wildland-Urban Interface Code adopted in Section 15.04.495 is modified,

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA § 15.04.500

PLACER COUNTY CODE

§ 15.04.505. Historical Building Code adopted.

The California Historical Building Code, 2025 Edition (California Code of Regulations Title 24, Part 8), as published by the International Code Council (ICC), is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.510. Fire Code adopted.

The California Fire Code (CFC) and all appendices except Appendix D, 2025 Edition (California Code of Regulations Title 24, Part 9), based on the 2021cer International Fire Code, is hereby adopted.

(Ord. 6345-B, 11/18/2025)

§ 15.04.520. Fire Code amended.

The California Fire Code (CFC) adopted in Section 15.04.510 is modified, amended and/or supplemented as set out in Sections 15.04.540 through 15.04.630. (Ord. 6345-B, 11/18/2025)

§ 15.04.540. Fire board of appeals.

Section 109 - Board of appeals. Replace the phrase "board of appeals" with "fire board of appeals."

Section 111 - Means of Appeals. Replace Section 111 of the CFC with the following section:

Section 111 - Means of appeals. In order to hear and determine appeals from code interpretations of the fire code official or designee, there is hereby appointed a fire board of appeals consisting of the board of directors of each fire protection district for matters within their jurisdiction and the Placer County building board of appeals in the remaining areas of the county. The chief shall be a non-voting ex-officio member of the board and shall act as secretary to the board. The board shall adopt reasonable rules and regulations for conducting its investigations and shall render all decisions and findings in writing to the chief with a duplicate copy to the appellant and may recommend to the board of supervisors such new legislation as is consistent therewith. Determination of appeal by fire board of appeals is final. (Ord. 6345-B, 11/18/2025)

§ 15.04.550. Violations.

Section 112.3 - Notice of violation. Add the following to Section 112.3 of the CFC:

The chief of any fire department/district within the county or his/her authorized representatives shall have authority to enforce the CFC, as amended herein, and issue citations for violations in their respective jurisdictions.

(Ord. 6345-B, 11/18/2025)

§ 15.04.560. Definitions.

Section 202 - General definitions. Add the following definitions to Section 202 of the CFC:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.560

§ 15.04.580

Access restrictions: Access is for emergency firefighting equipment only.

Approved gates: Any gate approved for emergency access and residential egress/evacuation, shall be manually opening with no lock or latch requiring special knowledge; or any gate approved by authority having jurisdiction.

Area, Building: The area included within surrounding exterior walls, or exterior walls and fire walls, exclusive of vent shafts and courts. Areas of the building not provided with surrounding walls shall be included in the building area if such areas are included within the horizontal projection of the roof or floor above.

Fire hydrant: A hydrant supplied by a 6-inch or larger branch line, one or more pumper connections (4 1/2 inch) and two or more 2 1/2 inch outlets, capable of supplying required fire flow for at least 2 hours.

Emergency vehicle access and occupant emergency egress/evacuation roads: Use - Access for emergency vehicles during an emergency.

Emergency egress/evacuation for residents during an emergency, Size: Roadways shall meet the requirements of the local authority having jurisdiction but shall not be less than the current requirements set forth in the CFC, as amended, and in the regulations adopted pursuant to Public Resources Code Section 4290.

Fire department access gates: Use - Fire Department access to open lands and vegetated areas for the purpose of extinguishing a vegetation fire. Size - Minimum twelve foot (12') wide opening with fifteen foot (15') vertical clearance. (Ord. 6345-B, 11/18/2025)

§ 15.04.570. Fire Code general requirements.

Section 301.1 - Scope. Add the following to Section 301.1 of the CFC:

The CFC as adopted above with approved amendments and appendices, and all state fire marshal codes delegated to local agencies, are to be enforced by the chief of the Placer County Fire Department or the chief of each fire district. In the absence of the above, the Placer County fire warden shall act as the county fire marshal. Where provisions in the CFC conflict with other statutes/regulations or county ordinances, the most restrictive shall govern.

Pursuant to Health and Safety Code Section 13869.7, all fire district amendments to the CFC will be valid after such amendments are first approved by the fire district board and then ratified by the board of supervisors. (Ord. 6345-B, 11/18/2025)

§ 15.04.580. Fire apparatus access roads.

Section 503.2.1 - Dimensions. Add the following to Section 503.2.1:

Driveways for single lot residential access may be twelve feet (12') in width as approved by the authority having jurisdiction.

Section 503.6 Security gates. Add the following to Section 503.6 of the CFC:

Private road gated entrances shall comply with the following requirements:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.580

§ 15.04.590

  1. Gate openings to be two feet (2') wider than the roadway served.

  2. Emergency vehicle access shall be provided by both a "Knox" over-ride switch and an approved emergency radio frequency gate opening device (Click2Enter type) or other device approved by the authority having jurisdiction.

  3. An approved hammerhead, turn-around bulb or other means of turn-around shall be provided on the entry side of the gate.

  4. Gates shall automatically open from the interior without use of a special code or device. (Magnetic strip or pressure pad assemblies are acceptable).

  5. All electric gates shall fail in the open position, e.g., loss of power, battery failure. All gates shall be equipped, at a minimum, with 12-hour battery backup.

  6. Vertical clearances shall be no less than fifteen feet (15').

  7. Gates shall be located no closer than thirty feet (30') from the intersecting roadway ultimate edge of pavement.

  8. Provide a separate accessible-compliant personnel gate or opening sized and surfaced to allow for pedestrian access.

  9. Gate components shall be maintained in an operative condition at all times and replaced or repaired when defective.

Gated residential driveways shall be provided with fire department access locks or switches as approved by the authority having jurisdiction. (Ord. 6345-B, 11/18/2025)

§ 15.04.590. Automatic sprinkler systems.

Section 903.2 - Amend Section 903.2 of the CFC as follows:

Approved automatic sprinkler systems in new buildings and structures, or changes in occupancy to existing buildings, shall be provided in the locations described in Sections 903.2.1 through 903.2.12.

Section 903.2 - Where required. Add the following to Section 903.2 of the CFC:

In all occupancies, except Group R, Division 3, and Group U, an approved automatic sprinkler system shall be installed where the occupancy/building has 3,600 or more square feet of total building area, except where other sections of the CFC or the California State Fire Marshal's regulations, and/or local fire district ordinances applicable to a project are more restrictive; then, the more restrictive shall apply. Where additions increase the total size of the building to 3,600 square feet or more, the addition and the existing occupancy/building shall be provided with an approved automatic sprinkler system. Fire separation areas shall not be used to reduce this requirement.

Section 903.3.1.3 - NFPA 13D sprinkler systems. Add the following to Section 903.3.1.3 of the CFC:

Automatic sprinkler systems installed in one- and two-family dwellings, Group R-3 and R-4 congregate living facilities and townhouses, shall be permitted to be installed throughout in

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.590

§ 15.04.620

accordance with the latest edition of NFPA Standard 13D and shall be equipped with a residential fire sprinkler water flow switch and interconnection to the residential smoke detector alarm system as defined in the building services division policy manual.

Section 903.4 - Sprinkler system supervision and alarms. Revise exception 1 in Section 903.4 of the CFC as follows:

  1. Automatic sprinkler systems protecting one- and two-family dwellings, unless required by the local fire district or authority having jurisdiction. (Ord. 6345-B, 11/18/2025)

§ 15.04.600. Fire alarm and detection systems.

Section 907.2 - Where required — new buildings and structures, or changes in occupancy to existing buildings. Replace Section 907.2 of the CFC with the following section:

Section 907.2 - Where required — new buildings and structures, or changes in occupancy to existing buildings. All occupancies except Group R, Division 3, and Group U occupancies shall have an approved automatic fire alarm system installed when the occupancy/building has 1,500 square feet or more of total building area, unless other sections of the CFC or California state fire marshal's regulations are more restrictive, in which case the more restrictive shall apply. Fire alarm systems shall be in accordance with Section 907 of the CFC or the current edition of NFPA 72 if the specific occupancy is not covered in the CFC. Where additions increase the total size of a building to 1,500 square feet or more, the addition and the existing occupancy/building shall be provided with an approved automatic fire alarm system.

Additionally, all A, E, H, I and M occupancies shall have an automatic smoke/heat detection system installed in addition to any other system(s) required by this code. Where additions increase the total size of the building to 1,500 square feet or more, the addition and the existing occupancy/building shall be provided with an approved automatic smoke/heat detection system.

Fire alarm control panels in new buildings shall be sized to allow for the maximum number of anticipated devices at build-out.

All automatic smoke and heat detection systems installed in addition to any other system(s) required by this code shall be automatically transmitted to an approved central station. (Ord. 6345-B, 11/18/2025)

§ 15.04.610. Tire storage.

Sections 3201.1 - Scope, 3405.1 - Individual piles, and 3409.1 - Pile dimensions. Add the following to Sections 3201.1, 3405.1, and 3409.1 of the CFC:

Tires: No person shall pile, cause to be piled, or maintain any pile of tires (of any manufactured material) at a height greater than 10 feet, except in approved horizontal storage racks, measured in all cases from the ground level. Tires shall be neatly piled and in no case shall any one pile occupy more than 200 square feet of floor or lot area. An aisle of at least 10 feet shall be maintained at all times between the piles in such a manner as to allow free access. (Ord. 6345-B, 11/18/2025)

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.620

§ 15.04.630

§ 15.04.620. Flammable and combustible liquids.

Section 5701.1 - Scope and Application. Replace Section 5701.1 of the CFC with the following section:

Section 5701.1 - Scope and Application. It shall be unlawful to store flammable liquids as defined in Chapter 57 of the CFC, including gasoline and other motor fuels, in aboveground storage containers, either portable or installed, in an RS, RM, RA, RF, F or AE zoned area on a parcel of less than 10 acres. In areas where above ground storage is permitted, minimum distances from property lines and structures for a tank of any type shall be not less than 50 feet. The limitations/prohibitions of this section shall also apply to areas in Olympic Valley designated as Low Density Residential (LDR), High Density Residential (HDR), ForestRecreation or Conservation Preserve. In addition, the limitations/prohibitions of this section shall apply to areas in the Lake Tahoe Basin which are designated as Tourist/Residential, Tourist, Residential, Recreation and Conservation.

Any above-ground storage must be approved, in writing, by an official of the appropriate fire protection department/district. This section shall not be applicable to portable containers suitable for such storage of 5 gallons or less.

Section 5704.2.9.6.1 - Locations where above-ground tanks are prohibited. Replace Section 5704.2.9.6.1 of the CFC with the following section:

Section 5704.2.9.6.1 - Locations where above-ground tanks are prohibited. Storage of Class I and/or Class II flammable liquids in above-ground tanks outside of buildings is prohibited unless approved by the fire chief having jurisdiction, using standards not less than as prescribed in the CFC or recognized equivalent.

Section 5706.4 - Bulk plants or terminals. Replace Section 5706.4 of the CFC with the following section:

Section 5706.4 - Bulk plants or terminals. No new bulk plant shall be constructed in districts in which such plants are prohibited by the Placer County zoning ordinance. Where allowed, portions of properties where flammable and combustible liquids are received by tank vessels, pipelines, tank cars, or tank vehicles and are stored or blended in bulk for the purpose of distributing such liquids by tank vessels, pipelines, tank cars, tank vehicles, or containers shall be in accordance with Sections 5706.4.1 through 5706.4.10.4. (Ord. 6345-B, 11/18/2025)

§ 15.04.630. Fire hydrants.

Appendix C - Fire Hydrant Locations and Distribution. Replace Table C102.1 of the CFC with the following table:

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

PLACER COUNTY CODE

§ 15.04.630

§ 15.04.650

==> picture [424 x 353] intentionally omitted <==

----- Start of picture text -----
TABLE C 102.1
NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
MAXIMUM
DISTANCE FROM
AVERAGE SPACING ANY POINT ON
FIRE-FLOW BETWEEN STREET OR ROAD
REQUIREMENT HYDRANTS1,2,3 FRONTAGE TO A
(gpm) (feet)6 HYDRANT4
MINIMUM NO. OF
X 3.785 for L/min. HYDRANTS X 304.8 for mm
0 - 1,000 1 300 250
1,000 - 1,750 2 300 250
2,000 - 2,250 2 300 225
2,500 3 300 225
3,000 3 300 225
3,500 - 4,000 4 300 210
4,500 - 5,000 5 300 180
5,500 6 300 180
6,000 6 250 150
6,500 - 7,000 7 250 150
7,500 or more 8 or more5 200 120
----- End of picture text -----

  1. Reduce by 100 feet for dead-end streets or roads.

  2. Where streets are provided with median dividers that cannot be crossed by fire fighters pulling hose lines, or arterial streets are provided with four or more traffic lanes and have a traffic count of more than 30,000 vehicles per day, hydrant spacing shall average 500 feet (152.4 m) on each side of the street and be arranged on an alternating basis up to a fire-flow requirement of 7,000 gallons per minute (26,495 L/min.) and 400 feet (122 m) for higher fire-flow requirements.

  3. Where new water mains are extended along streets where hydrants are not needed for protection of structures or similar fire problems, fire hydrants shall be provided at not less than 1,000-foot (305 m) spacing to provide for transportation hazards.

  4. Reduce by 50 feet (15,240 mm) for dead-end streets or roads.

  5. One hydrant for each 1,000 gallons per minute (3785 L/min.) or fraction thereof.

  6. Spacing may be increased to 500 feet for single-family dwelling residential subdivisions.

  • (Ord. 6345-B, 11/18/2025)

§ 15.04.650. Existing Building Code adopted.

The California Existing Building Code, 2025 Edition (California Code of Regulations Title 24, Part 10), based on the 2024 International Existing Building Code, is hereby adopted.

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

BUILDING AND DEVELOPMENT

§ 15.04.650

§ 15.04.680

  • (Ord. 6345-B, 11/18/2025)

§ 15.04.660. CALGreen Code adopted.

The California Green Building Standards Code, 2025 Edition (California Code of Regulations Title 24, Part 11), is hereby adopted.

(Ord. 6345-B, 11/18/2025)

§ 15.04.670. California Referenced Standards Code adopted.

The California Referenced Standards Code, 2025 Edition (California Code of Regulations Title 24, Part 12), as published by the International Code Council (ICC), is hereby adopted. (Ord. 6345-B, 11/18/2025)

§ 15.04.680. Codes and standards adopted as reference.

The following codes and standards are hereby adopted as reference documents and may be used by the chief building official in accordance with California Building Code Sections 104.10 and 104.11 in a case-by-case review process:

  • A. International Building Code, 2024 Edition, published by ICC; International Residential Code, 2024 Edition, published by ICC; International Property Maintenance Code, 2024 Edition, published by ICC, as modified by the California Health and Safety Code, Title 25 of the California Code of Regulations, and as further modified in Placer County Code, Chapter 15, Article 15.56.

  • B. The latest edition of the following: Uniform Swimming Pool, Spa and Hot Tub Code; the International Pool and Spa Code; published supplements to the International Codes; the International Residential Code; the International Fuel Gas Code; the Urban-Wildland Interface Code; the Uniform Sign Code; IBC Appendix Chapters; National Fire Protection Association Standards; the Uniform Solar Energy Code; American National Standards, published by American National Standards Institute, Inc.; Masonry Fireplaces, Masonry Institute; and other nationally recognized standards.

  • (Ord. 6345-B, 11/18/2025)

Downloaded from https://ecode360.com/PL4987 on 2026-07-06

Placer County, CA

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Placer County Planning Code
Placer County Planning Code
  1. Chapter 15
  2. Part 10
  3. Part I — Administration
  4. Part II — Codes Adopted and Amended
  5. Part 1 — Purpose and Definitions
  6. Part 2 — General Requirements
  7. Part 3 — Procedures
  8. Part 4 — Plans and Specifications
  9. Part 5 — Geotechnical Investigations and Inspections
  10. Part 6 — Design Standards
  11. Part 7 — Improvement Security
  12. Part 8 — Enforcement
  13. Part 1
  14. Part 2 — Definitions
  15. Part 3 — General Provisions
  16. Part 4 — Administration
  17. Part 5 — Provision for Flood Hazard Reduction
  18. Part 6 — Variance Procedure
  19. Part 1 — General Provisions
  20. Part 2 — Definitions
  21. Part 3 — Violations and Penalties
  22. Part 4 — Administration and Enforcement
  23. Part 5 — Enforcement Proceedings
  24. Part 7 — Enforcement of the Notice and Order or Final Order
  25. Part 8 — Abatement of Nuisances
  26. Part 9 — Housing and Dangerous Building Code Enforcement Fund
  27. Part 10 — Rental Housing and Dangerous Building Enforcement Fees