UPC Section 203 is amended by changing subsection (a), and adding subsection (f), to read:

"(a) Copper tube for underground drainage and vent piping shall have a weight of not less than that of copper, water tube Type M."

"(f) Drop-eared fittings will be installed on all fixture and hose bib outlets, and securely fastened to adequate backing with screws. No galvanized or ferrous pipe and/or nipples shall be installed in a copper water system."