§ 53.56 DEFINITIONS.
Eureka Zoning Code · 2026-06 edition · updated 2026-07-25 · Eureka
For the purpose of this subchapter, the following definitions shall apply unless the context clearly indicates or requires a different meaning.
AIR GAP SEPARATION. The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the receptacle, and must be at least double the diameter of the supply pipe measured vertically above the flood level rim of the vessel. In no case may the gap be less than one inch.
AUXILIARY SUPPLY. Any water source or system other than the public potable water system, that may be available in the building or on the premises.
BACKFLOW. The reversal of flow, other than in the intended direction, into the distribution of the public water system from a user connection.
BACK PRESSURE. The backflow caused by a pump, elevated tank, boiler, or other means that could create pressure within the system greater than the city water supply.
BACK SIPHONAGE. A form of backflow due to a negative or subatmospheric pressure within the water system. BACKFLOW PREVENTION DEVICE. A state device to counteract back pressure or prevent back siphonage.
CROSS-CONNECTION. Any physical arrangement whereby a public water system is connected, directly or indirectly, with any other nonpotable water system, sewer, drain, conduit, pool, storage, reservoir, plumbing fixture, or other device which contains, or may contain, contaminated water, sewage, or other waste or liquid contamination into the public water system as a result of backflow. Bypass arrangements, jumper connections, movable sections, swivel or changeover devices, or other temporary or permanent devices through which, or because of which, backflow could occur, are considered to be cross-connections.
DOUBLE CHECK VALVE ASSEMBLY (DCVA). An approved assembly composed of two single, independently acting check valves, including tightly closing shutoff valves located at each end of the assembly and suitable connections for testing the watertightness of each check valve.
REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION DEVICE (RPBD). An approved device incorporating two or more check valves and an automatically operating differential relief valve located between the two checks, two shutoff valves, and equipped with the necessary appurtenances for testing. The device must operate to maintain the pressure in the zone between the two check valves, less than the pressure on the public water system side of the device. At cessation of normal flow, the pressure between the check valves must be less than the supply pressure. In the case of leakage of either check valve the differential relief valve must operate to maintain the reduced pressure by discharging to the atmosphere. When the inlet pressure drops below two pounds per square inch, the relief valve must open to the atmosphere thereby providing an atmospheric zone between the two check valves.
ure between the check valves must be less than the supply pressure. In the case of leakage of either check valve the differential relief valve must operate to maintain the reduced pressure by discharging to the atmosphere. When the inlet pressure drops below two pounds per square inch, the relief valve must open to the atmosphere thereby providing an atmospheric zone between the two check valves.
USER CONNECTION. The point of connection of a user's piping to the public potable water supply of the city. WATER USER. Any person obtaining water from the public water supply of the city. ('63 Code, § 5-10.102) (Ord. 469-C.S., passed 5-5-88)
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Eureka Zoning Code
- Article I — NAME AND SEAL; FORM OF GOVERNMENT; BOUNDARIES; MUN…
- Article II — ELECTIONS
- Article III — CITY COUNCIL
- Article IV — MAYOR
- Article V — ORDINANCES
- Article VI — ADMINISTRATION
- Article VII — FISCAL ADMINISTRATION
- Article VIII — OFFICERS AND EMPLOYEES
- Article IX — FRANCHISES
- Article X — INITIATIVE, REFERENDUM AND RECALL
- Article XI — MISCELLANEOUS PROVISIONS
- Chapter 10 — GENERAL PROVISIONS
- Chapter 30 — CITY COUNCIL
- Chapter 31 — CITY OFFICIALS
- Chapter 32 — CITY DEPARTMENTS
- Chapter 33 — BOARDS, COMMISSIONS, AND COMMITTEES
- Chapter 34 — PERSONNEL POLICIES
- Chapter 35 — FINANCE, REVENUE AND TAXATION
- Chapter 36 — HEALTH FACILITY REVENUE BONDS
- Chapter 37 — ELECTIONS
- Chapter 38 — CIVIL EMERGENCIES
- Chapter 39 — CITY POLICY
- Chapter 40 — TRANSFERS OF CITY-OWNED REAL PROPERTY
- Chapter 50 — SEWERS
- Chapter 51 — SOLID WASTE
- Chapter 52 — UNDERGROUND UTILITY DISTRICTS
-
▸ Chapter 53 — WATER
Overview- § 53.01 MANAGEMENT.
- § 53.02 ADMINISTRATION OF FUNDS.
- § 53.03 WATER SERVICE CONNECTIONS.
- § 53.04 MAIN EXTENSIONS.
- § 53.05 WATER CHARGES AND FEES.
- § 53.06 INDEPENDENT FIRE SPRINKLER SYSTEMS RATE.
- § 53.07 TEMPORARY SERVICE.
- § 53.08 TURN-ON CHARGE.
- § 53.09 SPECIAL SITUATIONS.
- § 53.10 DEPOSITS FOR WATER SERVICE.
- § 53.11 BILLING.
- § 53.12 METER TESTS.
- § 53.13 PROPERTY OWNERS RESPONSIBLE.
- § 53.14 SEPARATE SERVICE FOR DWELLINGS; CUSTOMER CONTROL VALVES.
- § 53.15 VACANCIES.
- § 53.16 ACCESS BY CITY REPRESENTATIVES.
- § 53.17 INTERFERENCE WITH WATER SYSTEM.
- § 53.18 OPENING FIRE HYDRANTS.
- § 53.19 INTERRUPTIONS IN SERVICE.
- § 53.20 INTERPRETATION.
- § 53.21 SUMMER IRRIGATION CHARGES.
- § 53.22 DISCONTINUANCE OF SERVICE FOR VIOLATION.
- § 53.35 PURPOSE.
- § 53.36 DEFINITIONS.
- § 53.37 APPLICATION.
- § 53.38 LARGE WATER USERS.
- § 53.39 SITE DESIGN REVIEW.
- § 53.40 WATER WASTE PROHIBITED.
- § 53.41 NONESSENTIAL USES; LIMITATIONS.
- § 53.42 ENFORCEMENT.
- § 53.43 OPERATIVE DATES.
- § 53.44 DISCONNECTION FOR VIOLATION.
- § 53.55 PURPOSE.
- § 53.56 DEFINITIONS.
- § 53.57 POLICY.
- § 53.58 INSPECTION AND DISCONTINUANCE OF SERVICE.
- § 53.59 WHERE PROTECTION IS REQUIRED.
- § 53.60 TYPE OF PROTECTIVE DEVICE REQUIRED.
- § 53.61 APPROVED BACKFLOW PREVENTION ASSEMBLY.
- § 53.62 INSPECTION AND TESTINGS.
- § 53.63 SPECIAL CONDITIONS.
- § 53.99 PENALTY.
- Chapter 54 — STORM WATER QUALITY MANAGEMENT AND DISCHARGE CONT…
- Chapter 55 — ENERGY
- Chapter 56 — STREETS
- Chapter 70 — GENERAL PROVISIONS
- Chapter 71 — TRAFFIC RULES
- Chapter 72 — STOPPING, STANDING AND PARKING
- Chapter 73 — BICYCLES
- Chapter 75 — MOBILE VENDORS OPERATING UPON A STREET
- Chapter 90 — ABANDONED VEHICLES
- Chapter 91 — ANIMALS
- Chapter 92 — FIRE PREVENTION
- Chapter 93 — PARKS AND RECREATION
- Chapter 94 — HEALTH AND SANITATION
- Chapter 95 — MUNICIPAL AIRPORT
- Chapter 96 — PARADES AND ASSEMBLIES
- Chapter 97 — SMOKING
- Chapter 98 — STREETS AND SIDEWALKS
- Chapter 99 — TRAINS AND RAILROADS
- Chapter 100 — HARBOR REGULATIONS
- Chapter 101 — FILMING
- Chapter 102 — BEEKEEPING
- Chapter 103 — PRIVATE SECURITY AND FIRE ALARM SYSTEMS
- Chapter 104 — MILITARY EQUIPMENT USE
- Chapter 110 — BUSINESS LICENSES
- Chapter 112 — AMBULANCES
- Chapter 113 — AMUSEMENTS
- Chapter 114 — CABLE TELEVISION SYSTEMS
- Chapter 115 — FOOD ESTABLISHMENTS AND OUTDOOR DINING AREAS
- Chapter 117 — MASSAGE PARLORS
- Chapter 118 — SOLICITORS, CANVASSERS, AND SIDEWALK VENDORS
- Chapter 119 — SECOND-HAND DEALERS
- Chapter 120 — TAXICABS AND LIMOUSINES
- Chapter 121 — OTHER VEHICLES FOR HIRE
- Chapter 122 — FOREIGN-TRADE ZONE
- Chapter 130 — OFFENSES AGAINST PUBLIC PEACE AND SAFETY
- Chapter 131 — PROPERTY OFFENSES
- Chapter 132 — DRUG OFFENSES
- Chapter 133 — WEAPONS OFFENSES
- Chapter 134 — ABATEMENT OF CHRONIC NUISANCE PROPERTIES
- Chapter 150 — BUILDING REGULATIONS
- Chapter 151 — AIRPORT ZONING
- Chapter 152 — PLANNING AND ZONING ADMINISTRATION
- Chapter 153 — FLOOD HAZARD AREA REGULATIONS
- Chapter 154 — SUBDIVISION REGULATIONS
- Chapter 155 — ZONING REGULATIONS
- Chapter 155 — ZONING REGULATIONS (old)
- Chapter 156 — COASTAL ZONING REGULATIONS
- Chapter 157 — HISTORIC PRESERVATION
- Chapter 158 — CANNABIS
- Chapter 159 — WIRELESS TELECOMMUNICATIONS FACILITIES