Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued
2025 California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-07-25 · California
| FEATURE OR MEASURE | LEVELS APPLICANT TO SELECT ELECTIVE MEASURES |
VERIFICATIONS ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD |
||||
|---|---|---|---|---|---|---|
| FEATURE OR MEASURE | Mandatory | Prerequisites and electives1 | Prerequisites and electives1 | Enforcing Agency All |
Installer or Designer All |
Third party All |
| FEATURE OR MEASURE | Mandatory | Tier 1 | Tier 2 | Tier 2 | Tier 2 | Tier 2 |
| Construction Waste Reduction, Disposal and Recycling | ||||||
| 4.408.1Recycle and/or salvage for reuse a minimum of 65 percent of the nonhazardous construction and demolition waste in accordance with one of the following: 1. Comply with a more stringent local construction and demolition waste management ordinance; or 2. A construction waste management plan, per Section 4.408.2; or 3. A waste management company, per Section 4.408.3; or 4. The waste stream reduction alternative, per Section 4.408.4. |
||||||
| A4.408.1 Construction waste generated at the site is diverted to recycle or salvage in compliance with one of the following: 1.Tier 1at least a 65 percent reduction with a third-party verification. 2.Tier 2 at least a 75 percent reduction with a third-party verification. **Exception:**Equivalent waste reduction methods are developed by working with local agencies. |
2 | 2 | ||||
| Building Maintenance and Operation | ||||||
| 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. |
||||||
| 4.410.2 Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible areas that serve the entire building and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals or meet a lawfully enacted local recycling ordinance, if more restrictive. **Exception:**Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. will also be exempt from the organic waste portion of this section. |
||||||
| Innovative Concepts and Local Environmental Conditions | ||||||
| A4.411.1Items in this section are necessary to address innovative concepts or local environmental conditions. |
||||||
| Item 1 | ~~~~ |
~~~~ |
~~~~ |
~~~~ |
~~~~ |
~~~~ |
| Item 2 | ~~~~ |
~~~~ |
~~~~ |
~~~~ |
~~~~ |
~~~~ |
| Item 3 | ~~~~ | ~~~~ | ~~~~ | ~~~~ | ~~~~ | ~~~~ |
| ENVIRONMENTAL QUALITY | ||||||
| Fireplaces | ||||||
| 4.503.1Any installed gas fireplace shall be a direct-vent sealed- combustion type. Any installed woodstove or pellet stove shall comply with US EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. |
||||||
| Pollutant Control | ||||||
| 4.504.1Duct openings and other related air distribution component openings shall be covered during construction. |
||||||
| 4.504.2.1Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. |
||||||
| 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. |
||||||
| 4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for ROC and other toxic compounds. |
||||||
| 4.504.2.4Documentation shall be provided to verify that compliant VOC limit finish materials have been used. |
||||||
| 4.504.3Carpet and carpet systems shall be compliant with VOC limits. | ~~~~ | ~~~~ | ~~~~ | ~~~~ | ||
| 4.504.480 percent of floor area receiving resilient flooring shall comply with specified VOC criteria. |
||||||
| 4.504.5Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior or exterior finish systems shall comply with low formaldehyde emission standards. |
APPENDIX A4-28 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A4 — RESIDENTIAL VOLUNTARY MEASURES
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Green Building Standards Code (Title 24, Part 11)
2025 California Green Building Standards Code (Title 24, Part 11)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — GREEN BUILDING
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 6 — REFERENCED ORGANIZATIONS AND STANDARDS
- Chapter 7 — INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
-
▸ Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Overview- Section A4.101 — GENERAL
- Section A4.102 — DEFINITIONS
- Section A4.103 — SITE SELECTION
- Section A4.104 — SITE PRESERVATION
- Section A4.105 — DECONSTRUCTION AND REUSE OF EXISTING MATERIALS
- Section A4.106 — SITE DEVELOPMENT
- Section A4.107
- Section A4.108 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.201 — GENERAL
- Section A4.202 — DEFINITIONS
- Section A4.203 — PERFORMANCE APPROACH FOR NEWLY CONSTRUCTED BU…
- Section A4.204 — REQUIREMENTS FOR ALTERATIONS TO EXISTING BUIL…
- Section A4.301 — GENERAL
- Section A4.302 — DEFINITIONS
- Section A4.303 — INDOOR WATER USE
- Section A4.304 — OUTDOOR WATER USE
- Section A4.305 — WATER REUSE SYSTEMS
- Section A4.306 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.401 — GENERAL
- Section A4.402 — DEFINITIONS
- Section A4.403 — FOUNDATION SYSTEMS
- Section A4.404 — EFFICIENT FRAMING TECHNIQUES
- Section A4.405 — MATERIAL SOURCES
- Section A4.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A4.407 — WATER RESISTANCE AND MOISTURE MANAGEMENT
- Section A4.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A4.409 — LIFE CYCLE ASSESSMENT
- Section A4.410 — BUILDING MAINTENANCE AND OPERATION
- Section A4.411 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.501 — GENERAL
- Section A4.502 — DEFINITIONS
- Section A4.503 — FIREPLACES
- Section A4.504 — POLLUTANT CONTROL
- Section A4.505 — INTERIOR MOISTURE CONTROL
- Section A4.506 — INDOOR AIR QUALITY AND EXHAUST
- Section A4.507 — ENVIRONMENTAL COMFORT
- Section A4.508 — OUTDOOR AIR QUALITY
- Section A4.509 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.601 — GENERAL
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A5.101 — GENERAL
- Section A5.102 — DEFINITIONS
- Section A5.103 — SITE SELECTION
- Section A5.104 — SITE PRESERVATION
- Section A5.105 — DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES
- Section A5.106 — SITE DEVELOPMENT
- Section A5.107 — BIRD-FRIENDLY BUILDING DESIGN
- Section A5.201 — GENERAL
- Section A5.202 — DEFINITIONS
- Section A5.203 — PERFORMANCE APPROACH
- Section A5.204 — MANDATORY REQUIREMENTS FOR ALTERATIONS TO EXI…
- Section A5.211 — RESERVED
- Section A5.212 — ELEVATORS, ESCALATORS AND OTHER EQUIPMENT
- Section A5.213 — ENERGY EFFICIENT FRAMING
- Section A5.301 — GENERAL
- Section A5.302 — DEFINITIONS
- Section A5.303 — INDOOR WATER USE
- Section A5.304 — OUTDOOR WATER USE
- Section A5.305 — WATER REUSE
- Section A5.401 — GENERAL
- Section A5.402 — DEFINITIONS
- Section A5.403 — FOUNDATION SYSTEMS
- Section A5.404 — EFFICIENT FRAMING TECHNIQUES
- Section A5.405 — MATERIAL SOURCES
- Section A5.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A5.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A5.409 — LIFE CYCLE ASSESSMENT
- Section A5.501 — GENERAL
- Section A5.502 — DEFINITIONS
- Section A5.504 — POLLUTANT CONTROL
- Section A5.507 — ENVIRONMENTAL COMFORT
- Section A5.508 — OUTDOOR AIR QUALITY
- Section A6.106 — SITE DEVELOPMENT
- Section A6.202 — DEFINITIONS
- Section A6.203 — PERFORMANCE APPROACH
- Section A6.204 — PRESCRIPTIVE APPROACH
- Section A6.205 — [OSHPD 1 & 4]—BUILDING ENVELOPE
- Section A6.207 — [OSHPD 1, 2 & 4]—HVAC DESIGN, EQUIPMENT AND I…
- Section A6.210 — [OSHPD 1, 2 & 4]—APPLIANCES
- Section A6.401 — GENERAL
- Section A6.407 — [OSHPD 1, 2 & 4]—WATER RESISTANCE AND MOISTUR…
- Section A6.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A6.410 — BUILDING MAINTENANCE AND OPERATION
- Section A6.504 — POLLUTANT CONTROL
- Section A6.505 — [OSHPD 1, 2 & 4]—INDOOR MOISTURE CONTROL