Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST
2025 California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-07-25 · California
| FEATURE OR MEASURE | LEVELS APPLICANT TO SELECT ELECTIVE MEASURES |
VERIFICATIONS ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD |
||||
|---|---|---|---|---|---|---|
| FEATURE OR MEASURE | Mandatory | Prerequisites and electives1 | Prerequisites and electives1 | Enforcing Agency All |
Installer or Designer All |
Third party All |
| FEATURE OR MEASURE | Mandatory | Tier 1 | Tier 2 | Tier 2 | Tier 2 | Tier 2 |
| PLANNING AND DESIGN | ||||||
| Site Selection | ||||||
| A4.103.1 A site which complies with at least one of the following characteristics is selected: 1. An infill site is selected. 2. A greyfield site is selected. 3. An EPA-recognized Brownfield site is selected. |
||||||
| A4.103.2 Facilitate community connectivity by one of the following methods: 1. Locate project within a1/4-mile true walking distance of at least 4 basic services; 2. Locate project within1/2-mile true walking distance of at least 7 basic services; 3. Other methods increasing access to additional resources. |
||||||
| Site Preservation | ||||||
| A4.104.1An individual with oversight responsibility for the project has participated in an educational program promoting environmentally friendly design or development and has provided training or instruction to appropriate entities. |
||||||
| Deconstruction and Reuse of Existing Materials | ||||||
| A4.105.2 Existing buildings are disassembled for reuse or recycling of building materials. The proposed structure utilizes at least one of the following materials which can be easily reused: 1. Light fixtures 2. Plumbing fixtures 3. Doors and trim 4. Masonry 5. Electrical devices 6. Appliances 7. Foundations or portions of foundations |
||||||
| Site Development | ||||||
| 4.106.2A plan is developed and implemented to manage storm water drainage during construction. |
||||||
| 4.106.3Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. |
||||||
| 4.106.4.1Provide capability for electric vehicle charging for one- and two-family dwellings; townhouses with attached private garages in accordance with Section 4.106.4.1. |
||||||
| 4.106.4.2 Provide capability for electric vehicle charging for multifamily dwellings and hotels/motels in accordance with Sections 4.106.4.2.2 and 4.106.4.2.6. |
||||||
| 4.106.4.3 Provide capability for electric vehicle charging for existing parking lots or new parking lots for existing residential buildings, hotels/motels in accordance with Section 4.106.4.3, as applicable. |
||||||
| 4.106.4.4Provide bicycle parking facilities as noted below or meet a local ordinance, whichever is more stringent. Number of bicycle parking spaces may be reduced, as approved by the enforcing agency, due to building site characteristics, including but not limited to, isolation from other development. 1. Provide short-term bicycle parking, per Section 4.106.4.4.1. 2. Provide long-term bicycle parking for multifamily buildings per Section 4.106.4.4.2. 3. Provide long-term bicycle parking for hotel and motel buildings, per Section 4.106.4.4.3. |
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A4 — RESIDENTIAL VOLUNTARY MEASURES
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Green Building Standards Code (Title 24, Part 11)
2025 California Green Building Standards Code (Title 24, Part 11)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — GREEN BUILDING
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 6 — REFERENCED ORGANIZATIONS AND STANDARDS
- Chapter 7 — INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
-
▸ Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Overview- Section A4.101 — GENERAL
- Section A4.102 — DEFINITIONS
- Section A4.103 — SITE SELECTION
- Section A4.104 — SITE PRESERVATION
- Section A4.105 — DECONSTRUCTION AND REUSE OF EXISTING MATERIALS
- Section A4.106 — SITE DEVELOPMENT
- Section A4.107
- Section A4.108 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.201 — GENERAL
- Section A4.202 — DEFINITIONS
- Section A4.203 — PERFORMANCE APPROACH FOR NEWLY CONSTRUCTED BU…
- Section A4.204 — REQUIREMENTS FOR ALTERATIONS TO EXISTING BUIL…
- Section A4.301 — GENERAL
- Section A4.302 — DEFINITIONS
- Section A4.303 — INDOOR WATER USE
- Section A4.304 — OUTDOOR WATER USE
- Section A4.305 — WATER REUSE SYSTEMS
- Section A4.306 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.401 — GENERAL
- Section A4.402 — DEFINITIONS
- Section A4.403 — FOUNDATION SYSTEMS
- Section A4.404 — EFFICIENT FRAMING TECHNIQUES
- Section A4.405 — MATERIAL SOURCES
- Section A4.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A4.407 — WATER RESISTANCE AND MOISTURE MANAGEMENT
- Section A4.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A4.409 — LIFE CYCLE ASSESSMENT
- Section A4.410 — BUILDING MAINTENANCE AND OPERATION
- Section A4.411 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.501 — GENERAL
- Section A4.502 — DEFINITIONS
- Section A4.503 — FIREPLACES
- Section A4.504 — POLLUTANT CONTROL
- Section A4.505 — INTERIOR MOISTURE CONTROL
- Section A4.506 — INDOOR AIR QUALITY AND EXHAUST
- Section A4.507 — ENVIRONMENTAL COMFORT
- Section A4.508 — OUTDOOR AIR QUALITY
- Section A4.509 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.601 — GENERAL
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A5.101 — GENERAL
- Section A5.102 — DEFINITIONS
- Section A5.103 — SITE SELECTION
- Section A5.104 — SITE PRESERVATION
- Section A5.105 — DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES
- Section A5.106 — SITE DEVELOPMENT
- Section A5.107 — BIRD-FRIENDLY BUILDING DESIGN
- Section A5.201 — GENERAL
- Section A5.202 — DEFINITIONS
- Section A5.203 — PERFORMANCE APPROACH
- Section A5.204 — MANDATORY REQUIREMENTS FOR ALTERATIONS TO EXI…
- Section A5.211 — RESERVED
- Section A5.212 — ELEVATORS, ESCALATORS AND OTHER EQUIPMENT
- Section A5.213 — ENERGY EFFICIENT FRAMING
- Section A5.301 — GENERAL
- Section A5.302 — DEFINITIONS
- Section A5.303 — INDOOR WATER USE
- Section A5.304 — OUTDOOR WATER USE
- Section A5.305 — WATER REUSE
- Section A5.401 — GENERAL
- Section A5.402 — DEFINITIONS
- Section A5.403 — FOUNDATION SYSTEMS
- Section A5.404 — EFFICIENT FRAMING TECHNIQUES
- Section A5.405 — MATERIAL SOURCES
- Section A5.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A5.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A5.409 — LIFE CYCLE ASSESSMENT
- Section A5.501 — GENERAL
- Section A5.502 — DEFINITIONS
- Section A5.504 — POLLUTANT CONTROL
- Section A5.507 — ENVIRONMENTAL COMFORT
- Section A5.508 — OUTDOOR AIR QUALITY
- Section A6.106 — SITE DEVELOPMENT
- Section A6.202 — DEFINITIONS
- Section A6.203 — PERFORMANCE APPROACH
- Section A6.204 — PRESCRIPTIVE APPROACH
- Section A6.205 — [OSHPD 1 & 4]—BUILDING ENVELOPE
- Section A6.207 — [OSHPD 1, 2 & 4]—HVAC DESIGN, EQUIPMENT AND I…
- Section A6.210 — [OSHPD 1, 2 & 4]—APPLIANCES
- Section A6.401 — GENERAL
- Section A6.407 — [OSHPD 1, 2 & 4]—WATER RESISTANCE AND MOISTUR…
- Section A6.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A6.410 — BUILDING MAINTENANCE AND OPERATION
- Section A6.504 — POLLUTANT CONTROL
- Section A6.505 — [OSHPD 1, 2 & 4]—INDOOR MOISTURE CONTROL