Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued
2025 California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-07-25 · California
| FEATURE OR MEASURE | LEVELS APPLICANT TO SELECT ELECTIVE MEASURES |
VERIFICATIONS ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD |
||||
|---|---|---|---|---|---|---|
| FEATURE OR MEASURE | Mandatory | Prerequisites and electives1 | Prerequisites and electives1 | Enforcing Agency All |
Installer or Designer All |
Third party All |
| FEATURE OR MEASURE | Mandatory | Tier 1 |
Tier 2 |
Tier 2 |
Tier 2 |
Tier 2 |
| A4.106.1 Reserved | ~~~~ | ~~~~ | ~~~~ | ~~~~ | ~~~~ | |
| A4.106.2.1Soil analysis is performed by a licensed design professional and the findings utilized in the structural design of the building. |
||||||
| A4.106.2.2Soil disturbance and erosion are minimized by at least one of the following: 1. Natural drainage patterns are evaluated and erosion controls are implemented to minimize erosion during construction and after occupancy. 2. Site access is accomplished by minimizing the amount of cut and fill needed to install access roads and driveways. 3. Underground construction activities are coordinated to utilize the same trench, minimize the amount of time the disturbed soil is exposed and the soil is replaced using accepted compaction methods. |
||||||
| A4.106.2.3 Topsoil shall be protected or saved for reuse as specified in this section. **Tier 1.**Displaced topsoil shall be stockpiled for reuse in a designated area and covered or protected from erosion. **Tier 2.**The construction area shall be identified and delineated by fencing or flagging to limit construction activity to the construction area. |
2 | 2 2 |
||||
| A4.106.3Postconstruction landscape designs accomplish one or more of the following: 1. Areas disrupted during construction are restored to be consistent with native vegetation species and patterns. 2. Utilize at least 75 percent native California or drought tolerant plant and tree species appropriate for the climate zone region. |
||||||
| A4.106.4Permeable paving is utilized for the parking, walking or patio surfaces in compliance with the following: Tier 1. Not less than 20 percent of the total parking, walking or patio surfaces shall be permeable. Tier 2. Not less than 30 percent of the total parking, walking or patio surfaces shall be permeable. |
2 | 2 | ||||
| A4.106.5Roofing materials shall have a minimum 3-year aged solar reflectance and thermal emittance or a minimum Solar Reflectance Index (SRI) equal to or greater than the values specified in the applicable tables. Low-rise Residential Tier 1 roof covering shall meet or exceed the values contained in Table A4.106.5.1(1). Tier 2 roof covering shall meet or exceed the values contained in Table A4.106.5.1(2). High-rise Residential, Hotels and Motels Tier 1 roof covering shall meet or exceed the values contained in Table A4.106.5.1(3). Tier 2 roof covering shall meet or exceed the values contained in Table A4.106.5.1(4). |
2 2 |
2 2 |
||||
| A4.106.6 Install a vegetated roof for at least 50 percent of the roof area. Vegetated roofs shall comply with requirements for roof gardens and landscaped roofs in the_California Building Code_, Chapters 15 and 16. |
||||||
| A4.106.7 Reduce nonroof heat islands for 50 percent of sidewalks, patios, driveways or other paved areas by using one or more of the methods listed. |
||||||
| A4.106.8.1 Tier 1 and Tier 2 for one- and two-family dwellings and townhouses with attached private garages. Install a dedicated 208/240-volt branch circuit, including an overcurrent protective device rated at 40 amperes minimum per dwelling unit. |
2 | 2 |
APPENDIX A4-24 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
APPENDIX A4 — RESIDENTIAL VOLUNTARY MEASURES
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Green Building Standards Code (Title 24, Part 11)
2025 California Green Building Standards Code (Title 24, Part 11)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — GREEN BUILDING
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 4 — RESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 5 — NONRESIDENTIAL MANDATORY MEASURES
- Chapter 6 — REFERENCED ORGANIZATIONS AND STANDARDS
- Chapter 7 — INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
-
▸ Chapter 8 — COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL
Overview- Section A4.101 — GENERAL
- Section A4.102 — DEFINITIONS
- Section A4.103 — SITE SELECTION
- Section A4.104 — SITE PRESERVATION
- Section A4.105 — DECONSTRUCTION AND REUSE OF EXISTING MATERIALS
- Section A4.106 — SITE DEVELOPMENT
- Section A4.107
- Section A4.108 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.201 — GENERAL
- Section A4.202 — DEFINITIONS
- Section A4.203 — PERFORMANCE APPROACH FOR NEWLY CONSTRUCTED BU…
- Section A4.204 — REQUIREMENTS FOR ALTERATIONS TO EXISTING BUIL…
- Section A4.301 — GENERAL
- Section A4.302 — DEFINITIONS
- Section A4.303 — INDOOR WATER USE
- Section A4.304 — OUTDOOR WATER USE
- Section A4.305 — WATER REUSE SYSTEMS
- Section A4.306 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.401 — GENERAL
- Section A4.402 — DEFINITIONS
- Section A4.403 — FOUNDATION SYSTEMS
- Section A4.404 — EFFICIENT FRAMING TECHNIQUES
- Section A4.405 — MATERIAL SOURCES
- Section A4.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A4.407 — WATER RESISTANCE AND MOISTURE MANAGEMENT
- Section A4.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A4.409 — LIFE CYCLE ASSESSMENT
- Section A4.410 — BUILDING MAINTENANCE AND OPERATION
- Section A4.411 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.501 — GENERAL
- Section A4.502 — DEFINITIONS
- Section A4.503 — FIREPLACES
- Section A4.504 — POLLUTANT CONTROL
- Section A4.505 — INTERIOR MOISTURE CONTROL
- Section A4.506 — INDOOR AIR QUALITY AND EXHAUST
- Section A4.507 — ENVIRONMENTAL COMFORT
- Section A4.508 — OUTDOOR AIR QUALITY
- Section A4.509 — INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL C…
- Section A4.601 — GENERAL
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A4.602 — RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST…
- Section A5.101 — GENERAL
- Section A5.102 — DEFINITIONS
- Section A5.103 — SITE SELECTION
- Section A5.104 — SITE PRESERVATION
- Section A5.105 — DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES
- Section A5.106 — SITE DEVELOPMENT
- Section A5.107 — BIRD-FRIENDLY BUILDING DESIGN
- Section A5.201 — GENERAL
- Section A5.202 — DEFINITIONS
- Section A5.203 — PERFORMANCE APPROACH
- Section A5.204 — MANDATORY REQUIREMENTS FOR ALTERATIONS TO EXI…
- Section A5.211 — RESERVED
- Section A5.212 — ELEVATORS, ESCALATORS AND OTHER EQUIPMENT
- Section A5.213 — ENERGY EFFICIENT FRAMING
- Section A5.301 — GENERAL
- Section A5.302 — DEFINITIONS
- Section A5.303 — INDOOR WATER USE
- Section A5.304 — OUTDOOR WATER USE
- Section A5.305 — WATER REUSE
- Section A5.401 — GENERAL
- Section A5.402 — DEFINITIONS
- Section A5.403 — FOUNDATION SYSTEMS
- Section A5.404 — EFFICIENT FRAMING TECHNIQUES
- Section A5.405 — MATERIAL SOURCES
- Section A5.406 — ENHANCED DURABILITY AND REDUCED MAINTENANCE
- Section A5.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A5.409 — LIFE CYCLE ASSESSMENT
- Section A5.501 — GENERAL
- Section A5.502 — DEFINITIONS
- Section A5.504 — POLLUTANT CONTROL
- Section A5.507 — ENVIRONMENTAL COMFORT
- Section A5.508 — OUTDOOR AIR QUALITY
- Section A6.106 — SITE DEVELOPMENT
- Section A6.202 — DEFINITIONS
- Section A6.203 — PERFORMANCE APPROACH
- Section A6.204 — PRESCRIPTIVE APPROACH
- Section A6.205 — [OSHPD 1 & 4]—BUILDING ENVELOPE
- Section A6.207 — [OSHPD 1, 2 & 4]—HVAC DESIGN, EQUIPMENT AND I…
- Section A6.210 — [OSHPD 1, 2 & 4]—APPLIANCES
- Section A6.401 — GENERAL
- Section A6.407 — [OSHPD 1, 2 & 4]—WATER RESISTANCE AND MOISTUR…
- Section A6.408 — CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RE…
- Section A6.410 — BUILDING MAINTENANCE AND OPERATION
- Section A6.504 — POLLUTANT CONTROL
- Section A6.505 — [OSHPD 1, 2 & 4]—INDOOR MOISTURE CONTROL