Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Section 301
California Existing Building Code (Title 24, Part 10) · 2019 edition · updated 2026-09-10 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
301.1 General. The repair, alteration, change of occupancy,¶
addition or relocation of all existing buildings shall comply with Section 301.2, 301.3, or 301.4. [OSHPD 1R, 2, 4 and 5] Section 301.4 not adopted by OSHPD.
Exceptions:
1. Existing state-owned structures. [BSC] The repair, alteration, change of occupancy, addition or reloca- tion of all existing buildings shall comply with the provisions of Sections 317 through 322 as the mini- mum standards for earthquake evaluation and design for retrofit of existing state-owned structures, including buildings owned by the University of Cali- fornia, the California State University, or the Judi- cial Council.
The provisions of Sections 317 through 322 may be
adopted by a local jurisdiction for earthquake eval- uation and design for retrofit of existing buildings.
2. Public school buildings [DSA-SS] The provisions of Sections 317 through 323 establish minimum standards for earthquake evaluation and design for the rehabilitation of existing buildings for use as public school buildings under the jurisdiction of the Division of the State Architect—Structural Safety (DSA-SS, refer to Section 1.9.2.1) where required by Sections 4-307 and 4-309(c) of the California Administrative Code.
The provisions of Sections 317 through 323 also establish minimum standards for earthquake evalu- ation and design for rehabilitation of existing public school buildings currently under the jurisdiction of DSA-SS.
3. Community college buildings. [DSA-SS/CC] The provisions of Sections 317 through 323 establish minimum standards for earthquake evaluation and design for the rehabilitation of existing buildings for use as community college buildings under the juris- diction of the Division of the State Architect—Struc- tural Safety/Community Colleges (DSA-SS/CC, refer to Section 1.9.2.2) where required by Sections 4-307 and 4-309(c) of the California Administrative Code.
The provisions of Sections 317 through 323 also
establish minimum standards for earthquake evalu- ation and design for rehabilitation of existing com-
munity college buildings currently under the jurisdiction of DSA-SS/CC.
4. [HCD 1] In addition to the requirements in this chapter, maintenance, alteration, repair, addition, or change of occupancy to existing buildings and accessory structures under the authority of the Department of Housing and Community Develop- ment, as provided in Section 1.8.2.1.1, shall comply with California Code of Regulations, Title 25, Divi- sion 1, Chapter 1, Subchapter 1.
Exceptions:
1. [HCD 2] For moved buildings and mainte- nance, alteration, repair, addition, or change of occupancy to existing buildings and accessory structures in mobilehome parks or special occupancy parks as pro- vided in Section 1.8.2.1.3, see California Code of Regulations, Title 25, Division 1, Chapters 2 and 2.2.
2. [HCD 1] Limited-density owner-built rural dwellings, as defined in Chapter 2 of the California Residential Code.
5. Hospital buildings removed from acute care ser- vice, skilled nursing facilities, intermediate-care facilities, correctional treatment centers and acute- psychiatric hospitals [OSHPD 1R, 2, 4, and 5]. The provisions of adopted sections in Chapters 3 through 5 shall control the alteration, repair and change of occupancy or function of existing struc- tures for applications listed in Section 1.10.1, 1.10.2, 1.10.4, and 1.10.5 regulated by the Office of Statewide Health Planning and Development (OSHPD). Functional service spaces shall comply with the requirements in the California Building Code, Sections 1224, 1225, 1226, 1227 and 1228.
301.2 Repairs. Repairs shall comply with the requirements¶
of Chapter 4.
301.3 Alteration, addition or change of occupancy. The¶
alteration, addition or change of occupancy of all existing buildings shall comply with one of the methods listed in Section 301.3.1, 301.3.2 or 301.3.3 as selected by the applicant. Sections 301.3.1 through 301.3.3 shall not be applied in combination with each other. [OSHPD 1R, 2, 4 and 5] Sections 301.3.2 and 301.3.3, not adopted by OSHPD.
Note: [HCD 1 & HCD 2] Sections 301.3.2 and 301.3.3 shall be permitted only if the performance compliance
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Existing Building Code (Title 24, Part 10)
- Chapter 2 — DEFINITIONS
- Appendix A — GUIDELINES FOR
- Appendix B — SUPPLEMENTARY
- Appendix C — GUIDELINES FOR THE
- Chapter 1 — SCOPE AND ADMINISTRATION
▸Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Overview- Section 301
- Section 302
- Section 303
- Section 304
- Section 305
- Section 306
- Section 307 — [OSHPD 1R, 2, and 5]
- Section 308 — [OSHPD 1R, 2 and 5]
- Section 309 — [OSHPD 1R]
- Section 313
- Section 314
- Section 315
- Section 316
- Section 317
- Section 318
- Section 319
- Section 320
- Section 321
- Section 322
- Section 323
- Section 302A
- Section 301A
- Section 303A
- Section 304A
- Section 305A
- Section 306A
- Section 307A
- Section 308A
- Section 309A
- Section 310A
- Chapter 4 — REPAIRS
- Chapter 5 — PRESCRIPTIVE COMPLIANCE METHOD
- Chapter 6 — CLASSIFICATION OF WORK
- Chapter 7 — ALTERATIONS - LEVEL 1
- Chapter 8 — ALTERATIONS - LEVEL 2
- Chapter 9 — ALTERATIONS - LEVEL 3
- Chapter 10 — CHANGE OF OCCUPANCY
- Chapter 11 — ADDITIONS
- Chapter 12 — HISTORIC BUILDINGS
- Chapter 13 — PERFORMANCE COMPLIANCE METHODS
- Chapter 14 — RELOCATED OR MOVED BUILDINGS
- Chapter 15 — CONSTRUCTION SAFEGUARDS
- Chapter 16 — REFERENCED STANDARDS