Chapter 16 — REFERENCED STANDARDS
Section A404 — PRESCRIPTIVE MEASURES FOR WEAK STORY
2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
[BS] A404.1 Limitation. These prescriptive measures shall apply only to two-story buildings and only where deemed appropriate by the code official. These prescriptive measures rely on rotation of the second floor diaphragm to distribute the seismic load between the side and rear walls around a ground floor open area. In the absence of an existing floor diaphragm of wood structural panel or diagonal sheathing at the top of the first story, a new wood structural panel diaphragm of minimum thickness of [3] / 4 inch (19.1 mm) and with 10d common nails at 6 inches (152 mm) on center shall be…