Chapter 16 — REFERENCED STANDARDS

Section A112 — ANALYSIS AND DESIGN

2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

[BS] A112.1 General. The following requirements are applicable to both the general procedure and the special procedure for analyzing vertical elements of the lateral force-resisting system. [BS] A112.2 In-plane shear of unreinforced masonry walls. [BS] A112.2.1 Flexural rigidity. Flexural components of deflection need not be considered in determining the rigidity of an unreinforced masonry wall. [BS] A112.2.2 Shear walls with openings. Wall piers shall be analyzed according to the following procedure, which is diagrammed in Figure A112.2.2. 1. For any pier: 1.1. The pier shear capacity shall…