Chapter 16 — REFERENCED STANDARDS
Section A107 — QUALITY CONTROL
2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
[BS] A107.1 Pointing. Preparation and mortar pointing shall be performed with special inspection. Exception: At the discretion of the code official, incidental pointing may be performed without special inspection. [BS] A107.2 Masonry shear tests. In-place masonry shear tests shall comply with Section A106.2.3.1. Testing of masonry for determination of splitting tensile strength shall comply with Section A106.2.3.3. [BS] A107.3 Existing wall anchors. Existing wall anchors used as all or part of the required tension anchors shall be tested in pullout according to Section A107.5.1. Not fewer…