Chapter 16 — REFERENCED STANDARDS
Section A206 — ANALYSIS AND DESIGN
2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · ingested 2026-07-07 · California
Full text via GoCodebook AI
We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.
[BS] A206.1 Reinforced concrete and reinforced masonry wall anchorage. Concrete and masonry walls shall be anchored to all floors and roofs that provide lateral support for the wall in accordance with Section 12.11.2 of ASCE 7. The anchorage shall provide a direct connection capable of resisting 75 percent of the forces specified in Section 12.11.2.1 of ASCE 7. Exceptions: 1. Existing walls need not be evaluated or retrofitted for bending between anchors. 2. Work required by this chapter need not consider shrinkage, thermal changes or differential settlement. A206.1.1 Seismicity parameters,…