Chapter 12 — INTERIOR ENVIRONMENT
Section 1237 — [DPH]—WILD ANIMAL QUARANTINE FACILITIES
2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
1237.1 Scope. ¶
The provisions of this section are intended to provide standards for the quarantine of wild animals.
1237.2 Definitions. ¶
For the purpose of this chapter, the following terms shall have the meaning indicated:
ESCAPEPROOF is a condition that will prohibit unintended release of wild animals from their quarantine enclosure.
HOUSING FACILITY is a room, building or area used to contain a primary enclosure or enclosures for animal quarantine.
PRIMARY ENCLOSURE is a structure used to immediately restrict an animal or animals to a limited amount of space, such as a room, pen, run, cage or compartment within the quarantine facility.
QUARANTINE FACILITY is a facility for the quarantine confinement of imported wild animals.
SPACE CONDITIONING is the regulation of ambient temperature.
1237.3 Construction. ¶
1237.3.1 General. Housing facilities used for quarantine shall be constructed in accordance with these provisions and Group B occu- pancy requirements.
1237.3.2 Entry. Quarantine housing facilities shall restrict the entry of other animals and unauthorized persons by locking or bolting devices or other equipment methods.
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
INTERIOR ENVIRONMENT
Rooms containing primary enclosures shall be entered through double doors that maintain a minimum distance of 4 feet (1219 mm) between doors permitting closure of one door before the second is opened.
All animals must be visible through a viewpoint from the entry area.
Windows to the outside shall be escapeproof.
One handwashing sink shall be provided in each room in which animals are quarantined.
1237.3.3 Special provision. The interior building surfaces of housing facilities shall be smooth and impervious to moisture.
1237.4 Light and ventilation. ¶
All portions of the wild animal quarantine facility shall be space conditioned to maintain the health of the wild animals. Ventilation shall be provided in housing facilities so as not to create a health hazard by one or more of the following methods. 1. Openable windows
2. Doors
3. Vents
4. Air conditioning
5. Fans
Uniformly distributed illumination of not less than 50 footcandles (538 lux) at least the level of the cage racks shall be provided.
1237.5 Primary enclosure. ¶
Primary enclosures shall be capable of containing quarantined animals and excluding access by other animals. Enclosures shall provide space to allow each animal to make normal postural adjustments with freedom of movement and maintain social activity. Primates shall be provided with a minimum floor space equal to an area of at least three times the area occu- pied by such primates when standing on four feet.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Building Code (Title 24, Part 2)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11 — RESERVED
- Chapter 11A — HOUSING ACCESSIBILITY
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
-
▸ Chapter 12 — INTERIOR ENVIRONMENT
Overview- Section 1201 — GENERAL
- Section 1202 — VENTILATION
- Section 1203 — TEMPERATURE CONTROL
- Section 1204 — LIGHTING
- Section 1205 — YARDS OR COURTS
- Section 1206 — SOUND TRANSMISSION
- Section 1207 — ENHANCED CLASSROOM ACOUSTICS
- Section 1208 — INTERIOR SPACE DIMENSIONS
- Section 1209 — ACCESS TO UNOCCUPIED SPACES
- Section 1210 — TOILET AND BATHROOM REQUIREMENTS
- Section 1211 — UV GERMICIDAL IRRADIATION SYSTEMS
- Section 1212 — [HCD 1 & HCD 2]—GARAGE DOOR SPRINGS
- Section 1213 — [HCD 1]—POLLUTANT CONTROL
- Section 1214 — RESERVED
- Section 1215 — RESERVED
- Section 1216 — RESERVED
- Section 1217 — RESERVED
- Section 1218 — RESERVED
- Section 1219 — RESERVED
- Section 1220 — RESERVED
- Section 1221 — RESERVED
- Section 1222 — RESERVED
- Section 1223 — RESERVED
- Section 1224 — [OSHPD 1]—HOSPITALS
- Section 1225 — [OSHPD 2]-SKILLED NURSING AND INTERMEDIATE-CARE…
- Section 1226 — [OSHPD 3]-CLINICS
- Section 1227 — [OSHPD 4]-CORRECTIONAL TREATMENT CENTERS
- Section 1228 — [OSHPD 5]—ACUTE PSYCHIATRIC HOSPITALS
- Section 1229 — [OSHPD 6] — CHEMICAL DEPENDENCY RECOVERY HOSPIT…
- Section 1230 — [BSCC] — MINIMUM STANDARDS FOR JUVENILE FACILIT…
- Section 1231 — [BSCC] — LOCAL DETENTION
- Section 1232 — RESERVED
- Section 1233 — RESERVED
- Section 1234 — RESERVED
- Section 1235 — [DPH]—SANITARY CONTROL OF SHELLFISH (PLANTS AND…
- Section 1236 — [DPH]—LABORATORY ANIMAL QUARTERS
- Section 1237 — [DPH]—WILD ANIMAL QUARANTINE FACILITIES
- Section 1238 — RESERVED
- Section 1239 — RESERVED
- Section 1240 — [AGR]—MEAT AND POULTRY PROCESSING PLANTS
- Section 1241 — [AGR]—COLLECTION CENTERS AND FACILITIES
- Section 1242 — [AGR]—RENDERERS
- Section 1243 — [AGR]—HORSEMEAT AND PET FOOD ESTABLISHMENTS
- Section 1244 — RESERVED
- Section 1245 — RESERVED
- Section 1246 — RESERVED
- Section 1247 — RESERVED
- Section 1248 — RESERVED
- Section 1249 — RESERVED
- Section 1250 — [CA]—PHARMACIES
- Section 1251 — [CA]—VETERINARY PREMISES
- Section 1252 — [CA]—BARBER COLLEGES AND SHOPS
- Section 1253 — [CA]—SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL EST…
- Section 1254 — [CA]—ACUPUNCTURE OFFICES
- Chapter 13 — ENERGY EFFICIENCY
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 17A — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 18A — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 19A — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 21A — MASONRY
- Chapter 22 — STEEL
- Chapter 22A — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 29 — PLUMBING SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 34 — RESERVED
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U—AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix E — RESERVED
- Appendix F — RODENTPROOFING
- Appendix G — FLOOD-RESISTANT CONSTRUCTION
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
- Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
- Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — PERFORMANCE-BASED APPLICATION
- Appendix P — SLEEPING LOFTS
- Appendix Q — EMERGENCY HOUSING