1231.1 Definitions.

1231.1 Definitions. BOARD OF STATE & COMMUNITY CORRECTIONS means the Board of State & Community Corrections, which acts by and through its executive officer, deputy directors and field representatives. LIVING AREAS means those areas of a facility utilized for the day-to-day housing and activities of incarcerated persons. These areas do not include special-use cells such as sobering, safety and holding or staging cells normally located in receiving areas. LOCAL DETENTION FACILITY is any city, county, city and county or regional jail, camp, court holding facility or other correctional facility,…

1231.2 Design criteria for required spaces.

1231.2 Design criteria for required spaces. 1231.2.1 Reception and booking. Facilities where booking and housing occur shall have the following space and equipment: 1. Weapons locker as specified in Section 1231.3.12. 2. A holding cell or room for the confinement of incarcerated persons pending their booking, complying with Section 1231.2.2. 3. A sobering cell as described in Section 1231.2.4 if intoxicated, incarcerated persons who may pose a danger to themselves or others are held. Except for temporary holding facilities, those facilities that accept male and female intoxicated persons two…

1231.3 Design criteria for furnishings and equipment.

1231.3 Design criteria for furnishings and equipment. Furnishings and equipment shall be as follows: 1231.3.1 Toilets/urinals. 1. Toilets/urinals must be provided in single-occupancy cells and double-occupancy cells. 2. In dormitories, toilets/urinals must be provided in a ratio to incarcerated people of 1:10. 3. Toilets/urinals must be accessible to the occupants of day-rooms and exercise areas. 4. In temporary holding cells and temporary staging cells toilets/urinals must be provided in a ratio to incarcerated people of 1:16. 5. In sobering cells toilets/urinals must be provided in a ratio…

1231.4 Enclosure of vertical openings.

1231.4 Enclosure of vertical openings. Elevator shafts, vent shafts and other vertical openings shall be enclosed, and the enclosure shall be as set forth in Chapter 7.

1231.5 Fire-extinguishing systems.

1231.5 Fire-extinguishing systems. Automatic fire-extinguishing systems, standpipes and basement pipe inlets shall be installed when and as required by Chapter 9.

1231.6 Existing Group I occupancies.

1231.6 Existing Group I occupancies. Existing buildings housing existing protective social-care homes or facilities established prior to the effective date of these regulations may have their use continued if they conform, or are made to conform, to the following provisions. 1231.6.1 Use of floors. The use of floor levels in buildings of Type III, IV or V nonfire-rated construction may be as follows: Nonambulatory—first floor only; Ambulatory—not higher than the third-floor level, provided walls and partitions are constructed of materials equal in fire- resistive quality to that of wood lath…