Section 511C — SPECIAL PROCEDURE
511C.7 Out-of-Plane Forces – Unreinforced Masonry Walls.
San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco
Esta sección aún no está traducida y se muestra en inglés.
511C.7 Out-of-Plane Forces – Unreinforced Masonry Walls.
511C.7.1 Allowable unreinforced masonry wall height-to-thickness ratios. The provisions of Section 510C.2 are applicable except the allowable height-to-thickness ratios given in Table 5C-B shall be determined from Figure 5C-1 as follows:
In Region 1, height-to-thickness ratios for buildings with crosswalls may be used if qualifying crosswalls are present in all stories.
In Region 2, height-to-thickness ratios for buildings with crosswalls may be used whether or not qualifying crosswalls are present.
In Region 3, height-to-thickness ratios for “all other buildings” shall be used whether or not qualifying crosswalls are present.
511C.7.2 Walls with diaphragms in different regions. When diaphragms above and below the wall under consideration have demand-capacity ratios in different regions of Figure 5C-1, the lesser height-to-thickness ratio shall be used.