Section 506E — ENGINEERING CRITERIA FOR EVALUATION AND RETROFIT.

506E.3 Alternative Retrofit Criteria.

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

506E.3 Alternative Retrofit Criteria. A proposed seismic retrofit plan which fails to meet the criteria of 506E.2(1) or 506E.2(5) shall be deemed to comply with this Chapter if with the approval of the Department, it satisfies the intent of FEMA P-807, Section 6.4.2 with a maximum acceptable Onset of Strength Loss drifts limit probability of exceedance of 70 percent.

Exception: Alternative retrofit criteria shall not apply to buildings in which the critical stories, basements or underfloor areas contain other than parking, storage, or utility uses or occupancies.

GoCodebook ofrece acceso público limitado, búsqueda, citas, explicación multilingüe e interpretación práctica de normas de construcción legalmente adoptadas. No sustituye a las publicaciones oficiales del ICC ni de los códigos de California.