502C.6 Buildings of Mixed Construction.
San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco
Esta sección aún no está traducida y se muestra en inglés.
502C.6 Buildings of Mixed Construction. When buildings having at least one bearing wall of unreinforced masonry also utilize other structural systems, the following requirements shall apply:
502C.6.1 Masonry-wood or steel mix. When the lower stories of the building are of unreinforced masonry bearing wall construction and the upper stories are of wood frame or steel stud construction, the unreinforced masonry stories shall be strengthened to meet the requirements of the general procedure of this chapter and the other stories need not be strengthened.
502C.6.2 Masonry-concrete mix. When a building is of mixed unreinforced masonry bearing wall construction and reinforced concrete or masonry
construction, the entire building shall be strengthened in accordance with a program developed by the owner’s architect or engineer and approved by
t he Building Official.