Section 435 — SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A
435.3 Add the following section:
San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco
Esta sección aún no está traducida y se muestra en inglés.
435.3 Add the following section:
435.3.5 For detached one- and two-family dwellings, and townhouses not more than three stories above grade plane in height with a separate means of egress, buildings housing protective social-care homes or in occupancies housing inmates who are not restrained need not be of one-hour fire-resistive
construction when not more than two stories in height. In no case shall individual floor areas exceed 3,000 square feet (279 m [2] ). The fire-resistive
protection of the exterior walls shall not be less than one hour where such walls are located within 5 feet (1524 mm) of the property line. Openings
w it hin such walls are not permitted. Openings within non-rated walls need not be protected. [California Residential Code Section R335.9]