Section 1505 — FIRE CLASSIFICATION
1505.1 Add the following second exception:
San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco
Esta sección aún no está traducida y se muestra en inglés.
1505.1 Add the following second exception:
- Detached accessory structures with a roof of less than 200 square feet (18.58 m [2] ) may have roof coverings of Class A, B or C.
Table 1505.1 Revise the table as follows:
TABLE 1505.1 – MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
| IA | IB | IIA | IIB | IIIA | IIIB | IV | VA | VB |
|---|---|---|---|---|---|---|---|---|
| B | B | B | [← ] B | B | [← ] B | B | B | [← ] B |
| Col1 | Col2 | |||||||
| --- | --- | |||||||
| SECTION 1507 – REQUIREMENTS FOR ROOF COVERINGS | SECTION 1507 – REQUIREMENTS FOR ROOF COVERINGS |
1507.8.5 Add the following sentence at the end of the paragraph:
Untreated wood shingles shall not be permitted.
1507.9.6 Add the following sentence at the end of the paragraph:
U n treated wood shakes shall not be permitted.