Section 108A — INSPECTIONS

108A.4 Approval required.

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

108A.4 Approval required. No work shall be done on any part of the building or structure beyond the point indicated in each successive inspection without first obtaining the approval of the Building Official. Such approval shall be given only after an inspection shall have been made of each successive step in the construction as indicated by each of the inspections required in Section 108A.5. Any portions which do not comply with the provisions of this code and with the approved construction documents shall be corrected, and no such portion shall be covered or concealed until approved.

108A.5. Required inspections.

108A.5.1 General. The structural framework of any part of any building or structure shall not be covered or concealed without first obtaining the approval of the building official.

Protection of joints and penetrations in fire-resistive assemblies shall not be concealed from view until inspected and approved.

108A.5.2 Foundation inspection. Inspection shall be made after excavations for footings is complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place prior to inspection. All materials for the foundation shall be on the job site; however, where concrete is ready mixed in accordance with approved nationally recognized standards, the concrete need not be on the job site. Where the foundation is to be constructed of approved treated wood, additional inspections may be required by the building official.

108A.5.3 Concrete slab or under-floor inspection. Inspection shall be made after all in-slab or under-floor reinforcing steel building service equipment, conduit, piping accessories and other ancillary equipment items are installed, before any concrete is placed or floor sheathing installed, including the subfloor.

108A.5.4 Reinforcing steel. Inspection shall be made when reinforcing steel is in place in walls, floor and roof framing and other concrete members, and before any concrete is poured or placed. All reinforcing steel shall be visible for inspection.

108A.5.5 Structural steel. Inspection shall be made when structural steel framework, or any structural steel member of a building, is in place and before being covered or concealed in any manner.

108A.5.6 Frame inspection. Inspection shall be made after the roof, roof deck or sheathing, all framing, fire blocking and bracing are in place and all conduits, plumbing pipes, chimneys and vents to be concealed are complete and the rough electrical, plumbing, and heating wires, conduits, plumbing pipes and ducts are approved.

108A.5.7 Lath or gypsum board inspection. Inspection shall be made after all lathing and gypsum board, interior and exterior, are in place, but before any plastering is applied or before gypsum board joints and fasteners are taped and finished.

108A.5.8 Fire-rated suspended ceilings. Inspection shall be made after the installation of the hangers, lighting fixtures and air diffusers, the protective fixture boxes and main suspended ceiling members and before the ceiling is installed.

108A.5.9 Final inspection. A final inspection shall be made when the construction work has been completed, and the structure is ready for occupancy, but before it is occupied. There shall be a final inspection and approval on all buildings and structures when completed and ready for occupancy or use after plumbing, electrical and special inspection, and any other applicable approvals have been obtained. See Section 109A for certificate of occupancy requirements.

An exclusive electrical or plumbing final approval shall not be given or posted unless it is ascertained by the Building Official that no building permit is required.