Section 1004A — SPECIAL HOTEL AND MOTEL SECURITY REQUIREMENTS

1004A.1 Entry doors to guest rooms.

San Francisco Building Inspection Commission Codes · edición 2022 · actualizado 2026-07-08 · San Francisco

Esta sección aún no está traducida y se muestra en inglés.

1004A.1 Entry doors to guest rooms.

EXCEPTION: Residential care facilities licensed by the State of California under Title 22 of the California Code of Regulations shall not be required to comply with the requirements of this subsection.

Locks shall be a combination of minimum 1/2-inch (12.7 mm) throw deadlatch with a minimum 1-inch (25.4 mm) deadbolt.

All locks shall be capable of locking out all keys, except the emergency keys for guest privacy while inside the room, and so constructed that both deadlatch and deadbolt are retracted simultaneously by a single knob or lever.