CWUIC · California Wildland-Urban Interface Code

What must be included in landscape / vegetation plans?

If your project is in a fire hazard area and the code official requires a landscape or vegetation plan, the plan must map the **30‑foot** and **100‑foot** fuel‑management zones, identify which plants stay or are planted (with botanical and common names), show irrigated areas and the groundcover inside the 30‑foot zone, and include a timetable and maintenance plan for clearing and thinning fuels — per **§ 603.3.1** and **§ B101.2** .

Last reviewed: July 6, 2026

What the code requires — 2–4 sentences

Landscape (vegetation) plans submitted where required must show the fuel-management zones around structures, identify existing and proposed plants and irrigation, provide a plant legend with botanical and common names, and identify groundcover in the highest-risk area adjacent to structures — § 603.3.1 . Vegetation management plans for permits must also describe the actions, schedules and maintenance measures that will prevent fire spread to or from the building, including removal of slash, snags, ladder fuels and thinning of trees — § B101.2 .

The single most important requirement: the plan must clearly show the 30‑foot and 100‑foot fuel-management zones and document what vegetation will remain, what will be planted, and how it will be maintained for ongoing fuel reduction — § 603.3.1 .

Requirements in detail

Minimum contents required by § 603.3.1 (Landscape plans)

Landscape plans shall contain at least all of the following elements. Items are quoted here as requirements paraphrased from the code; for the original text see § 603.3.1 .

  • Bold, visible delineation of the 30‑foot (9144 mm) and 100‑foot (30 480 mm) fuel-management zones from all structures — § 603.3.1 .
  • Identification of existing vegetation to remain and proposed new vegetation (i.e., which plants are removed vs. retained/installed) — § 603.3.1 .
  • Identification of irrigated areas (where irrigation will be provided) — § 603.3.1 .
  • A plant legend that lists both botanical (scientific) and common names and identifies symbols used on the plan for each plant material — § 603.3.1 .
  • Identification of ground coverings (mulch, gravel, hardscape, lawn, etc.) within the 30‑foot (9144 mm) zone — § 603.3.1 .

Minimum contents required by § B101.2 (Vegetation management plans — Appendix B)

When Appendix B is adopted or required by the authority having jurisdiction, vegetation management plans must include the following points as a minimum — § B101.2 :

  • A copy of the site plan (location and context of work) — § B101.2 .
  • Methods and timetables for controlling, changing or modifying vegetation on the property. The plan elements must explicitly address:
    • Removal of slash and snags.
    • Removal or control of vegetation that may grow into overhead electrical lines.
    • Removal/control of other ground fuels, ladder fuels, and dead trees.
    • Thinning of live trees where appropriate — § B101.2 .
  • A maintenance plan describing how the proposed fuel‑reduction measures will be kept in place over time (timing, responsible party, frequency) — § B101.2 .

Decision table — what to show and why

Item to include on the plan Decision‑relevant dimension / value Code Reference
Fuel‑management zones 30‑foot (9144 mm) and 100‑foot (30 480 mm) measured from structures § 603.3.1
Existing vs. proposed vegetation Show retained plants vs. removals and new plant locations § 603.3.1
Irrigation locations Mark irrigated zones (affects plant selection and fire‑smart classification) § 603.3.1
Plant legend Botanical & common names; symbol for each species; expected mature size often required elsewhere in the code § 603.3.1
Groundcover in 30‑ft zone Identify mulch, rock, lawn, pavement within 30‑ft zone § 603.3.1
Removal and control actions Specific methods (e.g., remove slash/snags, thin trees, eliminate ladder fuels) and timetables § B101.2
Maintenance plan Who, how often, and what actions will be taken to maintain fuel reduction § B101.2

Exceptions & special cases

  • Appendix B is informational unless an adopting ordinance makes it mandatory. Plans must follow § B101.2 only if Appendix B has been adopted into the local code or is explicitly required by the code official — § B101.2 .
  • The landscape requirements of § 603.3.1 apply where the code official requires a landscape plan; the code official can determine when a plan is required and may require additional documentation as needed — § 603.3.1 .
  • Where other sections or local ordinances require additional details (for example, final fire protection plans that include plant life‑form and mature sizes), include those details as well — see related provisions (e.g., fire protection plan content requirements) referenced elsewhere in the code.

Common mistakes

  • Omitting the exact fuel‑management zone lines on the drawing (not showing the 30‑ft and 100‑ft boundaries) — this is the most common rejection reason under § 603.3.1 .
  • Using only common names in the plant legend (inspectors need botanical names too) — § 603.3.1 requires both names .
  • Failing to show which areas are irrigated versus non‑irrigated; irrigation status affects allowable plant choices and maintenance expectations — required by § 603.3.1 .
  • Submitting a vegetation plan without a clear maintenance timetable or without identifying who is responsible for ongoing clearance — Appendix B requires a plan for maintaining measures § B101.2 .

Worked example — single‑family house on a sloped lot

Scenario: New house with attached garage located in a Fire Hazard Severity Zone. The code official requires a landscape and a vegetation management plan.

What to include (numbers shown):

  • Draw and label two concentric buffers around the structure: the inner 30‑foot (9144 mm) zone and the outer 100‑foot (30 480 mm) zone — § 603.3.1 .
  • On the plan, mark existing oak tree at 40 ft from the house (retain), and an existing dense shrub patch at 20 ft (remove or replace). Indicate the shrub patch as “Remove: dense coyote brush” and show replacement with a fire‑smart irrigated native groundcover (name botanical + common) — § 603.3.1 .
  • Show irrigation lines/zones: drip irrigation to replacement groundcover and no irrigation to retained native oak (if applicable) — § 603.3.1 .
  • Provide plant legend listing: Quercus agrifolia — Coast live oak — symbol “T1”; Salvia spathacea — Hummingbird sage — symbol “S1” (botanical + common names required) — § 603.3.1 .
  • Vegetation management plan actions and timetable (per § B101.2): remove shrub patch and slash within 30 days; thin understory ladder fuels extending beneath tree crowns within 60 days; annual maintenance to inspect and remove dead wood in spring thereafter. State responsible party: homeowner association/owner and frequency (annual). Include these steps and dates on the submitted plan — § B101.2 .

Related provisions (see these sections for additional detail)

  • § 603.3.1 — Landscape plan contents (primary) .
  • § B101.2 — Vegetation management plan content — Appendix B (site plan, methods, timetables, maintenance) .
  • § 602.3.2 — Final fire protection plan content (when a fire protection plan is required it may call for plant lists with life‑form and mature sizes) .
  • § [A] 106.3 — Site plan requirements referencing landscape and vegetation details (plans must be clear and to scale) .
  • § 603.4 — Fire‑smart vegetation criteria and limits for shrubs/trees that affect what you show on the plan .

Code references

Grounded in the retrieved California Wildland-Urban Interface Code — click a citation to read the verbatim passage:

  • CWUIC § 6-3 High relevance — show source text

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FIRE PROTECTION REQUIREMENTS

    602.3.2 Final fire protection plan. Final fire protection plan shall include items listed in Section 602.3.1 and the following: 1. A map identifying all proposed plants in the fuel modification zones with a legend that includes a symbol for each proposed plant species. The plan shall include specific information on each species proposed, including but not limited to: 1.1. The plant life-form;

    1.2. The scientific and common name; and

    1.3. The expected height and width for mature growth. 2. Identification of irrigated and nonirrigated zones. 3. Requirements for vegetation reduction around emergency access and evacuation routes. 4. Identification of points of access for equipment and personnel to maintain vegetation in common areas. 5. Legally binding statements regarding community responsibility for maintenance of fuel modification zones. 6. Legally binding statements to be included in covenants, conditions and restrictions regarding property owner responsibili- ties for vegetation maintenance.

    SECTION 603— VEGETATION PLAN

    603.1 General. Planting of vegetation for new landscaping shall be selected to reduce vegetation in proximity to a structure and to maintain vegetation as it matures.

    603.2 Application. All new plantings of vegetation in State Responsibility Area (SRA) and Local Responsibility Areas (LRA) designated as a Fire Hazard Severity Zone shall comply with Sections 603.3 through 603.4.2.1.

    603.3 Landscape plans. Landscape plans shall be provided when required by the code official. The landscape plan shall include devel- opment and maintenance requirements for the vegetation management zone adjacent to structures and roadways, and provide significant fire hazard reduction benefits for public and firefighting safety.

    603.3.1 Contents. Landscape plans shall contain the following: 1. Delineation of the 30-foot (9144 mm) and 100-foot (30 480 mm) fuel management zones from all structures. 2. Identification of existing vegetation to remain and proposed new vegetation. 3. Identification of irrigated areas. 4. A plant legend with both botanical and common names, and identification of all plant material symbols. 5. Identification of ground coverings within the 30-foot (9144 mm) zone.

    603.4 Vegetation. All new vegetation shall be fire-smart vegetation in accordance with this section.

    Exception: Trees classified as nonfire-smart vegetation complying with Section 603.4.2.1.

    To be considered fire-smart vegetation, vegetation must meet at least one of the following: 1. Be identified as fire-smart vegetation in an approved book, journal or listing from an approved organization. 2. Be identified as fire-smart vegetation by a licensed landscape architect with supporting justification. 3. Plants considered fire-smart vegetation and approved by the local enforcing agency.

  • CWUIC § 603.2 High relevance — show source text

    603.2 Application. All new plantings of vegetation in State Responsibility Area (SRA) and Local Responsibility Areas (LRA) designated as a Fire Hazard Severity Zone shall comply with Sections 603.3 through 603.4.2.1.

    603.3 Landscape plans. Landscape plans shall be provided when required by the code official. The landscape plan shall include devel- opment and maintenance requirements for the vegetation management zone adjacent to structures and roadways, and provide significant fire hazard reduction benefits for public and firefighting safety.

    603.3.1 Contents. Landscape plans shall contain the following: 1. Delineation of the 30-foot (9144 mm) and 100-foot (30 480 mm) fuel management zones from all structures. 2. Identification of existing vegetation to remain and proposed new vegetation. 3. Identification of irrigated areas. 4. A plant legend with both botanical and common names, and identification of all plant material symbols. 5. Identification of ground coverings within the 30-foot (9144 mm) zone.

    603.4 Vegetation. All new vegetation shall be fire-smart vegetation in accordance with this section.

    Exception: Trees classified as nonfire-smart vegetation complying with Section 603.4.2.1.

    To be considered fire-smart vegetation, vegetation must meet at least one of the following: 1. Be identified as fire-smart vegetation in an approved book, journal or listing from an approved organization. 2. Be identified as fire-smart vegetation by a licensed landscape architect with supporting justification. 3. Plants considered fire-smart vegetation and approved by the local enforcing agency.

    603.4.1 Shrubs. All new plantings of shrubs shall comply with the following: 1. Shrubs shall not exceed 6 feet (1829 mm) in height. 2. Groupings of shrubs are limited to a maximum aggregate diameter of 10 feet (3048 mm). 3. Shrub groupings shall be separated from other groupings a minimum of 15 feet (4572 mm). 4. Shrub groupings shall be separated from structures a minimum of 30 feet (9144 mm). 5. Where shrubs are located below or within a tree’s drip line, the lowest tree branch shall be a minimum of three times the height of the understory shrubs or 10 feet (3048 mm), whichever is greater.

    603.4.2 Trees. Trees shall be managed as follows within the 30-foot zone (9144 mm) of a structure: 1. New trees shall be planted and maintained so that the tree’s drip line at maturity is a minimum of 10 feet (3048 mm) from any combustible structure. 2. The horizontal distance between crowns of new trees and crowns of adjacent trees shall not be less than 10 feet (3048 mm). 3. Existing trees shall be trimmed to provide a minimum separation of 10 feet (3048 mm) away from chimney and stovepipe outlets per California Code of Regulations, Title 14, Section 1299.03.

  • CWUIC § 1.11. High relevance — show source text
    • The California Code of Regulations (CCR), Title 19, Division 1 provisions that are found in the California Wildland-Urban Interface Code are a reprint from the current CCR, Title 19, Division 1 text for the code user’s convenience only. The scope, applicability and appeals procedures of CCR, Title 19, Division I remain the same. The state agency does not adopt sections identified by the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.

    The California Code of Regulations (CCR), Title 14, Division 1.5 provisions that are found in the California Wildland-Urban Interface Code are not listed in the Matrix Adoption Tables as they are not within the State Fire Marshal’s authority to adopt. These provisions are a reprint from the current CCR, Title 14, Division 1.5 text for the code user’s convenience only and are identified in the body of the code by square brackets containing references to applicable Title 14 sections.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-2 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    B VEGETATION MANAGEMENT PLAN

    The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.

    User notes:

    About this appendix: Appendix B, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide criteria for submitting vegetation management plans, specifying their content and establishing a criterion for considering vegetation management as being a fuel modification.

    SECTION B101—GENERAL

    B101.1 Scope. Vegetation management plans shall be submitted to the code official for review and approval as part of the plans required for a permit.

    B101.2 Plan content. Vegetation management plans shall describe all actions that will be taken to prevent a fire from being carried toward or away from the building. A vegetation management plan shall include the following information:

    1. A copy of the site plan.
    2. Methods and timetables for controlling, changing or modifying areas on the property. Elements of the plan shall include removal of slash, snags, vegetation that may grow into overhead electrical lines, other ground fuels, ladder fuels and dead trees, and the thinning of live trees.
    3. A plan for maintaining the proposed fuel-reduction measures.

    B101.3 Fuel modification. To be considered a fuel modification for purposes of this code, continuous maintenance of the clearance is required.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA WILDLAND-URBAN INTERFACE CODE – MATRIX ADOPTION TABLE APPENDIX C – COMMUNITY WILDLAND-URBAN INTERFACE (WUI) FIRE HAZARD EVALUATION FRAMEWORK

  • CWUIC § B101 High relevance — show source text

    SECTION B101—GENERAL

    B101.1 Scope. Vegetation management plans shall be submitted to the code official for review and approval as part of the plans required for a permit.

    B101.2 Plan content. Vegetation management plans shall describe all actions that will be taken to prevent a fire from being carried toward or away from the building. A vegetation management plan shall include the following information:

    1. A copy of the site plan.
    2. Methods and timetables for controlling, changing or modifying areas on the property. Elements of the plan shall include removal of slash, snags, vegetation that may grow into overhead electrical lines, other ground fuels, ladder fuels and dead trees, and the thinning of live trees.
    3. A plan for maintaining the proposed fuel-reduction measures.

    B101.3 Fuel modification. To be considered a fuel modification for purposes of this code, continuous maintenance of the clearance is required.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA WILDLAND-URBAN INTERFACE CODE – MATRIX ADOPTION TABLE APPENDIX C – COMMUNITY WILDLAND-URBAN INTERFACE (WUI) FIRE HAZARD EVALUATION FRAMEWORK

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    (Not adopted by the State Fire Marshal)

    Adopting Agency BSC BSC-
    CG
    SFM Col5 HCD Col7 Col8 DSA Col10 OSHPD Col12 Col13 Col14 Col15 Col16 BSCC DPH AGR DWR CEC CA SL SLC
    Adopting Agency BSC BSC-
    CG
    T-24 T-19* 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5
    Adopt Entire Chapter
    Adopt Entire Chapter as
    amended (amended sections
    listed below)
    Adopt only those sections that
    are listed below
    [California Code of Regulations,
    Title 19, Division 1]
    Chapter / Section
  • CWUIC § 106.3 High relevance — show source text

    [A] 106.3 Site plan. In addition to the requirements for plans in the California Building Code, site plans shall include topography, width and percent of grade of access roads, landscape and vegetation details, locations of structures or building envelopes, existing or proposed overhead utilities, occupancy classification of buildings, types of ignition-resistant construction of buildings, structures and their appendages, roof classification of buildings and site water supply systems. The code official is authorized to waive or modify the requirement for a site plan where the application for permit is for alteration or repair or where otherwise warranted.

    [A] 106.4 Vegetation management compliance . Prior to the building permit final approval, the property shall be in compliance with the vegetation management requirements prescribed in Section 603, including California Public Resources Code 4291 or California Government Code Section 51182. Acceptable methods of compliance inspection and documentation shall be determined by the enforc- ing agency and shall be permitted to include any of the following: 1. Local, state or federal fire authority or designee authorized to enforce vegetation management requirements. 2. Enforcing agency.

    1-20 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    ADMINISTRATION

    3. Third-party inspection and certification authorized to enforce vegetation management requirements. 4. Property owner certification authorized by the enforcing agency.

    [A] 106.5 Fire protection plan. Where required by the code official pursuant to Section 602, a fire protection plan shall be prepared and shall be submitted to the code official for review and approved as a part of the plans required for a permit.

    [A] 106.6 Other data and substantiation. Where required by the code official, the plans and specifications shall include classification of fuel loading, fuel model light, medium or heavy, and substantiating data to verify classification of fire-smart vegetation.

    [A] 106.7 Vicinity plan. In addition to the requirements for site plans, plans shall include details regarding the vicinity within 300 feet (91 440 mm) of lot lines, including other structures, slope, vegetation, fuel breaks, water supply systems and access roads.

    [A] 106.8 Retention of plans. One set of approved plans, specifications and computations shall be retained by the code official for a period of not less than 180 days from date of completion of the permitted work or as required by state or local laws; and one set of approved plans and specifications shall be returned to the applicant, and said set shall be kept on the site of the building, use or work at all times during which the work authorized thereby is in progress. Refer to Building Standards Law, Health and Safety Code Sections 19850 and 19851 for permanent retention of plans.

    [A] 106.9 Examination of documents. The code official shall examine or cause to be examined the accompanying construction documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code and other pertinent laws or ordinances.

    [A] 106.10 Amended construction documents. Work shall be installed in accordance with the approved construction documents, and changes made during construction that are not in compliance with the approved documents shall be resubmitted for approval as an amended set of construction documents.

  • CWUIC § 102.4 High relevance — show source text

    The chapter includes mitigation strategies to reduce the hazards of fire originating within a structure spreading to wildland and fire originating in wildland spreading to structures.

    Chapter 7 Referenced Standards.

    Chapter 7 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 6 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.

    Appendix A General Requirements.

    Appendix A, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide fire-protection measures supplemental to those found in Chapter 6 to reduce the threat of wildfire in a wildland-urban interface area and improve the capability for controlling such fires. This appendix includes detailed requirements for vegetation control; the code official’s authority to close wildland-interface areas in times of high fire danger; control of fires, fireworks usage and other sources of ignition; storage of hazardous materials and combustibles; bans on the dumping of waste materials and ashes and coals in wildlandurban interface areas; protection of pumps and water supplies; and limits on temporary uses within the wildland-urban interface area.

    Appendix B Vegetation Management Plan.

    Appendix B, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide criteria for submitting vegetation management plans, specifying their content and establishing a criterion for considering vegetation management as being a fuel modification.

    Appendix C Community Wildland-Urban Interface (WUI) Fire Hazard Evaluation Framework.

    Appendix C contains a preliminary Community WUI Fire Hazard Evaluation Framework as a suggested methodology to begin to support communities at risk in the identification of their unique hazards and to provide common metrics for comparisons between communities. This preliminary framework includes information on community size, population and fuels; on notification and evacuation; and on the community infrastructure and firefighting response potential. Aspects of this framework may already be included in various community- level documents, such as Community Wildfire Protection Plans or evacuation plans. Development of a standard framework will (1) consolidate relevant WUI fire hazard and planning information in one place, and (2) allow for cross-community comparisons.

    The evaluation required to implement this framework will support prefire hazard assessment and during-fire response operations. An increased understanding of fire evacuation, fire structural response and fire defensive action relationships is needed to assess the over- all community WUI fire hazard. The quantification of these relationships will enable communities to optimize the community-level response to WUI fire hazards in a more integrated approach and result in increased life safety and reduced losses.

    Appendix D Model Ordinance for Fire Hazard Severity Zone Adoption.

    Appendix D is an informational appendix that is a sample ordinance designed as guidance for a city, county, city and county, or fire district to establish and designate fire hazard severity zones within their jurisdiction.

    Appendix E Reserved.

    Appendix F Characteristics of Fire-Smart Vegetation.

    Appendix F is an informational appendix provided for the convenience of the code user. It is simply a compilation of the eight characteristics of fire-smart vegetation that can be used effectively within wildland-urban interface areas to reduce the likelihood of fire spread through vegetation.

    **App

  • CWUIC § 602.2 Medium relevance — show source text

    602.2 Contents. The fire protection plan shall be based on a project-specific wildfire hazard assessment that includes considerations of location, topography, aspect and climatic and fire history.

    The plan shall identify conformance with all applicable state wildfire protection regulations, statutes and applicable local ordi- nances, whichever are more restrictive.

    The plan shall address fire department access, egress, road and address signage and water supply in addition to fuel reduction in accordance with Public Resources Code (PRC) 4290; the defensible space requirements in accordance with PRC 4291 or Government Code 51182; and the applicable building codes and standards for wildfire safety. The plan shall identify mitigation measures to address the project’s specific wildfire risk and shall include the information required in Sections 602.3 through 602.3.2.

    602.3 Project information. The final fire protection plan shall be reviewed and approved prior to start of construction.

    602.3.1 Preliminary fire protection plan. When a preliminary fire protection plan is submitted, it shall include, at a minimum, the following: 1. Total size of the project. 2. Information on the adjoining properties on all sides, including current land uses, and if known, existing structures and densi- ties, planned construction, natural vegetation, environmental restoration plans, roads and parks. 3. A map with all project boundary lines, property lines, slope contour lines, proposed structure foundation footprints, and proposed roads and driveways. The map shall identify project fuel modification zones and method of identifying the fuel modification zone boundaries.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FIRE PROTECTION REQUIREMENTS

    602.3.2 Final fire protection plan. Final fire protection plan shall include items listed in Section 602.3.1 and the following: 1. A map identifying all proposed plants in the fuel modification zones with a legend that includes a symbol for each proposed plant species. The plan shall include specific information on each species proposed, including but not limited to: 1.1. The plant life-form;

    1.2. The scientific and common name; and

    1.3. The expected height and width for mature growth. 2. Identification of irrigated and nonirrigated zones. 3. Requirements for vegetation reduction around emergency access and evacuation routes. 4. Identification of points of access for equipment and personnel to maintain vegetation in common areas. 5. Legally binding statements regarding community responsibility for maintenance of fuel modification zones. 6. Legally binding statements to be included in covenants, conditions and restrictions regarding property owner responsibili- ties for vegetation maintenance.

    SECTION 603— VEGETATION PLAN

    603.1 General. Planting of vegetation for new landscaping shall be selected to reduce vegetation in proximity to a structure and to maintain vegetation as it matures.

    603.2 Application. All new plantings of vegetation in State Responsibility Area (SRA) and Local Responsibility Areas (LRA) designated as a Fire Hazard Severity Zone shall comply with Sections 603.3 through 603.4.2.1.

  • CWUIC § 106.1 Medium relevance — show source text
    1. It is used by a person other than the person to whom the permit was issued.
    2. It is used for a location other than that for which the permit was issued.
    3. Any of the conditions or limitations set forth in the permit have been violated.
    4. The permittee fails, refuses or neglects to comply with any order or notice duly served on him or her under the provisions of this code within the time provided therein.
    5. There has been any false statement or misrepresentation as to material fact in the application or plans on which the permit or application was made.
    6. The permit is issued in error or in violation of any other ordinance, regulations or provisions of this code.

    The code official is allowed to, in writing, suspend or revoke a permit issued under the provisions of this code whenever the permit is issued in error or on the basis of incorrect information supplied, or in violation of any ordinance or regulation or any of the provisions of this code.

    SECTION 106—CONSTRUCTION DOCUMENTS

    [A] 106.1 General. Plans, engineering calculations, diagrams and other data shall be submitted in not fewer than two sets, or in a digital format where allowed by the code official, with each application for a permit. The construction documents shall be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. Where special conditions exist, the code official is authorized to require additional documents to be prepared by a registered design professional.

    Exception: Submission of plans, calculations, construction inspection requirements and other data, if it is found that the nature of the work applied for is such that reviewing of plans is not necessary to obtain compliance with this code.

    [A] 106.2 Information on plans and specifications. Plans and specifications shall be drawn to scale on substantial paper or cloth and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations.

    [A] 106.3 Site plan. In addition to the requirements for plans in the California Building Code, site plans shall include topography, width and percent of grade of access roads, landscape and vegetation details, locations of structures or building envelopes, existing or proposed overhead utilities, occupancy classification of buildings, types of ignition-resistant construction of buildings, structures and their appendages, roof classification of buildings and site water supply systems. The code official is authorized to waive or modify the requirement for a site plan where the application for permit is for alteration or repair or where otherwise warranted.

    [A] 106.4 Vegetation management compliance . Prior to the building permit final approval, the property shall be in compliance with the vegetation management requirements prescribed in Section 603, including California Public Resources Code 4291 or California Government Code Section 51182. Acceptable methods of compliance inspection and documentation shall be determined by the enforc- ing agency and shall be permitted to include any of the following: 1. Local, state or federal fire authority or designee authorized to enforce vegetation management requirements. 2. Enforcing agency.

    1-20 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    ADMINISTRATION

    3. Third-party inspection and certification authorized to enforce vegetation management requirements. 4. Property owner certification authorized by the enforcing agency.

  • CWUIC § 102.4 Medium relevance — show source text

    Chapter 5 Special Building Construction Regulations.

    The regulations in Chapter 5 establish minimum standards for the location, design and construction of buildings and structures based on construction within a Fire Hazard Severity Zone or a Wildland-Urban Interface (WUI) Area.

    The construction provisions of Chapter 5 are intended to supplement the requirements of the California Building Code and Califor- nia Residential Code and address mitigation of the unique hazards posed to buildings by wildfire and to reduce the hazards of building fires spreading to wildland fuels. This is accomplished by requiring ignition-resistant construction materials.

    Chapter 6 Fire Protection Requirements.

    Chapter 6 contains additional requirements for development and construction in Local Responsibility Areas (LRA) designated as Very High Fire Hazard Severity Zones and areas designated by the State Fire Marshal as State Responsibility Areas (SRA). While many of these provisions are found in Title 14 and Title 19 of the California Code of Regulations, they are replicated here for the code user. The local jurisdiction has the authority to apply the same regulations to LRA when the regulations are adopted by local ordinance.

    The requirements in this chapter reference the process for adoption of Very High Fire Hazard Severity Zones in the LRA; criteria for evaluating existing subdivisions that are at significant fire risk and are without an adequate secondary egress; and criteria for fire safety provisions required in the Safety Element of a city or county General Plan.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE xi

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    The chapter includes mitigation strategies to reduce the hazards of fire originating within a structure spreading to wildland and fire originating in wildland spreading to structures.

    Chapter 7 Referenced Standards.

    Chapter 7 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 6 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.

    Appendix A General Requirements.

    Appendix A, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide fire-protection measures supplemental to those found in Chapter 6 to reduce the threat of wildfire in a wildland-urban interface area and improve the capability for controlling such fires. This appendix includes detailed requirements for vegetation control; the code official’s authority to close wildland-interface areas in times of high fire danger; control of fires, fireworks usage and other sources of ignition; storage of hazardous materials and combustibles; bans on the dumping of waste materials and ashes and coals in wildlandurban interface areas; protection of pumps and water supplies; and limits on temporary uses within the wildland-urban interface area.

    Appendix B Vegetation Management Plan.

    Appendix B, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide criteria for submitting vegetation management plans, specifying their content and establishing a criterion for considering vegetation management as being a fuel modification.

    Appendix C Community Wildland-Urban Interface (WUI) Fire Hazard Evaluation Framework.

  • CWUIC § 6-1 Medium relevance — show source text

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6-2 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6 FIRE PROTECTION REQUIREMENTS

    User notes:

    About this chapter: In addition to the building construction requirements in the California Building Code and California Residential Code, this chapter contains requirements for development and construction in Local Responsibility Areas (LRA) designated as Very High Fire Hazard Severity Zones and areas designated by the State Fire Marshal as State Responsibility Areas (SRA). While many of these provisions are found in Title 14 and Title 19 of the California Code of Regulations, they are replicated here for the code user. The local jurisdiction has the authority to apply the same regulations to LRA when the regulations are adopted by local ordinance.

    The requirements in this chapter reference the process for adoption of Very High Fire Hazard Severity Zones in the LRA; criteria for evaluating existing subdivisions that are at significant fire risk and are without an adequate secondary egress; and criteria for fire safety provisions required in the Safety Element of a city or county General Plan.

    The chapter includes mitigation strategies to reduce the hazards of fire originating within a structure spreading to wildland and fire originating in wildland spreading to structures. These strategies are included in the following requirements:

    1. Development of fire protection plans.

    2. Development of landscape plans and long-term vegetation management.

    3. Creation and maintenance of defensible space to protect structures and subdivisions.

    SECTION 601—GENERAL

    601.1 Scope. The provisions of this chapter establish general requirements for new and existing buildings, structures and premises located within wildland-urban interface (WUI) areas .

    601.2 Objective. The objective of this chapter is to establish minimum requirements to mitigate conditions that might cause a fire originating in a structure to ignite vegetation in the wildland-urban interface (WUI) area, and conversely, a wildfire burning in vegetative fuels to transmit fire to buildings and threaten to destroy life, overwhelm fire suppression capabilities or result in large property losses.

    601.3 Chapter 6 definitions. Where used in this chapter, the term listed below shall be defined as follows:

    DEFENSIBLE SPACE. The buffer that landowners are required to create on their property between a “Building or Structure” and the plants, brush and trees or other items surrounding the “Building or Structure” that could ignite in the event of a fire. [CCR Title 14 §1299.02(a)]

    SECTION 602— FIRE PROTECTION PLANS

    602.1 General. The code official is authorized to require the owner or owner’s authorized agent to provide a fire protection plan. The fire protection plan shall be prepared to determine the acceptability of fire protection and life safety measures designed to mitigate wildfire hazards presented for the property under consideration.

    The fire protection plan shall be prepared by a registered design professional, qualified landscape architect, qualified fire safety specialist or similar specialist acceptable to the code official and shall analyze the wildfire risk of the building, project, premises or region to recommend necessary changes.

    The code official is authorized to require a preliminary fire protection plan prior to the submission of a final fire protection plan.

  • CWUIC § 403.2 Medium relevance — show source text

    APPENDIX I-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    Access Applicability 402 Driveways 403.2 Fire apparatus access roads 403.3 Grade 403.7

    Individual structures 402.2 Marking of roads 402.3, 403.4 Restricted 403.1

    Subdivisions 402.1 Accessory Buildings and Miscellaneous Structures

    Defined 202

    Detached 504.11 Exempt from permit 105.3 Additions or Alterations 101.5

    Address Markers 402.3 Agriculture 202 Alternative Materials or Methods 104.2.2

    Appeals 112 Appendices 101.2.1 Applicable Building 202 Applicability 102 Approved 202 Approved Agency 104.2.2.6.1, 202 Authority of Code Official 104

    Building 202 Building Official 202

    Certificate of Completion 111 Certificate of occupancy 111.2 Revocation 111.4

    Temporary occupancy 111.3

    Code Official 202 Code Official, Authority 104 Community Wildland-Urban Interface (WUI) Fire Hazard Evaluation Framework Appendix C Compliance Alternatives 105 Construction Documents 106

    Amended 106.10

    Examination of 106.9 Information on plans and specifications 106.2 Phased 106.12

    Previous approval 106.11 Retention of 106.8 Site plan 106.3 Vegetation management plans 106.4 Control of Storage Appendix A, A105 Critical Fire Weather 202

    Dead-end Road 202 Defensible Space 403, 601.3 Vegetation Plan 603 Definitions 202 Designation of Wildland-Urban Interface Area 302.1

    Director 202 Driveway 202 Dumping Appendix A, A106 Dwelling 202

    Exterior Covering 202

    INDEX

    Fees 109 Findings of Fact Appendix E Fire Chief 202 Fire Danger Rating System Appendix D Fire Flow Calculation Area Application 404.5 Defined 202 Fire Hazard Severity Zones 1.1.2, 202, 302.1, 302.2, Appendix D, Appendix H Fire Protection Plans 602

    Fire Weather 202

    Fire-Resistance-Rated Construction 501.3 Fire-Resistive Vegetation Appendix F Fire-Retardant-Treated Lumber or

    Wood 503.2, 504.5, 504.7, 504.11 Flame Spread Index 202 Flashing 504.2.1, 504.5.1 Fuel Break 202, 609 Fuel Models Appendix D Fuel Modification 202

    Fuel Modification Distance 603.2

    Fuel Mosaic 202 Fuel-Loading 202

    General Requirements Appendix A Green Belt 202

    Greenways 202

  • CWUIC § 601.1 Medium relevance — show source text

    SECTION 601—GENERAL

    601.1 Scope. The provisions of this chapter establish general requirements for new and existing buildings, structures and premises located within wildland-urban interface (WUI) areas .

    601.2 Objective. The objective of this chapter is to establish minimum requirements to mitigate conditions that might cause a fire originating in a structure to ignite vegetation in the wildland-urban interface (WUI) area, and conversely, a wildfire burning in vegetative fuels to transmit fire to buildings and threaten to destroy life, overwhelm fire suppression capabilities or result in large property losses.

    601.3 Chapter 6 definitions. Where used in this chapter, the term listed below shall be defined as follows:

    DEFENSIBLE SPACE. The buffer that landowners are required to create on their property between a “Building or Structure” and the plants, brush and trees or other items surrounding the “Building or Structure” that could ignite in the event of a fire. [CCR Title 14 §1299.02(a)]

    SECTION 602— FIRE PROTECTION PLANS

    602.1 General. The code official is authorized to require the owner or owner’s authorized agent to provide a fire protection plan. The fire protection plan shall be prepared to determine the acceptability of fire protection and life safety measures designed to mitigate wildfire hazards presented for the property under consideration.

    The fire protection plan shall be prepared by a registered design professional, qualified landscape architect, qualified fire safety specialist or similar specialist acceptable to the code official and shall analyze the wildfire risk of the building, project, premises or region to recommend necessary changes.

    The code official is authorized to require a preliminary fire protection plan prior to the submission of a final fire protection plan.

    602.2 Contents. The fire protection plan shall be based on a project-specific wildfire hazard assessment that includes considerations of location, topography, aspect and climatic and fire history.

    The plan shall identify conformance with all applicable state wildfire protection regulations, statutes and applicable local ordi- nances, whichever are more restrictive.

    The plan shall address fire department access, egress, road and address signage and water supply in addition to fuel reduction in accordance with Public Resources Code (PRC) 4290; the defensible space requirements in accordance with PRC 4291 or Government Code 51182; and the applicable building codes and standards for wildfire safety. The plan shall identify mitigation measures to address the project’s specific wildfire risk and shall include the information required in Sections 602.3 through 602.3.2.

    602.3 Project information. The final fire protection plan shall be reviewed and approved prior to start of construction.

    602.3.1 Preliminary fire protection plan. When a preliminary fire protection plan is submitted, it shall include, at a minimum, the following: 1. Total size of the project. 2. Information on the adjoining properties on all sides, including current land uses, and if known, existing structures and densi- ties, planned construction, natural vegetation, environmental restoration plans, roads and parks. 3. A map with all project boundary lines, property lines, slope contour lines, proposed structure foundation footprints, and proposed roads and driveways. The map shall identify project fuel modification zones and method of identifying the fuel modification zone boundaries.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-3

Frequently asked questions

What if my jurisdiction has not adopted Appendix B?

If Appendix B has not been adopted by the local jurisdiction, § B101.2 is informational only and not mandatory. However, many jurisdictions still expect the equivalent information; coordinate with the code official to confirm submission expectations .

Do I have to include botanical names for every plant?

Yes — § 603.3.1 requires a plant legend with both botanical and common names for each plant material shown on the landscape plan .

How should I show irrigation on the plan?

Mark irrigated vs. non‑irrigated zones clearly (label drip, spray, etc.) and show which planting areas each irrigation zone serves. Identification of irrigated areas is specifically required by § 603.3.1 .

Does the plan need a maintenance schedule?

Yes — Appendix B requires a plan for maintaining the proposed fuel‑reduction measures (who, how, how often) — § B101.2 .

Is showing mature plant size required?

While § 603.3.1 requires identification of plants, final fire protection plan requirements elsewhere call for plant life‑form and expected mature height/width; include mature size when submitting a fire protection plan or if requested by the code official (see related fire protection plan sections) .

More in California Wildland-Urban Interface Code

Ask about the CWUIC

Get cited, plain-English answers on the California Wildland-Urban Interface Code for your project — any code section, any scenario.

Start Free Trial

Related in the CWUIC