CWUIC · California Wildland-Urban Interface Code

Vegetation Management & Defensible Space (vegetation plans, maintenance, fire‑smart characteristics)

This hub explains how the CWUIC requires vegetation and fire‑protection plans, defines defensible‑space distances and maintenance duties, and points to the fire‑smart plant criteria.

Last reviewed: July 6, 2026

Overview

This part of the California Wildland‑Urban Interface Code (CWUIC) covers required wildfire‑risk mitigation for landscaping and fuels around buildings: when fire protection and vegetation‑management plans are required, what those plans must show, how defensible space is organized, and the maintenance obligations that keep fuel modifications effective over time. Chapter 6 frames the requirements for development and long‑term vegetation management in WUI areas, including the vegetation plan provisions in SECTION 603 and the maintenance/defensible‑space rules in SECTION 604 .

Key program elements include the plan and submittal requirements for fire protection and landscape/vegetation plans (§602 and §603), the mandatory defensible‑space and maintenance references to Public Resources Code §4291 (§604.3), and the code’s guidance on what counts as “fire‑smart” plantings (Appendix F, F101.1). The code expects landscape plans to delineate the 30‑ and 100‑foot fuel management zones and to identify existing and proposed plants, irrigated areas, and groundcover within the 30‑ft zone (§603.3.1) .

Practically, the CWUIC ties three things together: (1) design/submittal (fire protection and vegetation management plans that document fuel‑reduction measures and maintenance schedules), (2) siting and planting rules (landscape plan contents, shrub/tree spacing and non‑fire‑smart tree exceptions such as §603.4.2.1), and (3) ongoing obligations to maintain defensible space and fuel modifications so they remain effective (see §604 and the PRC §4291 references) .

In this section

Code references

Grounded in the retrieved California Wildland-Urban Interface Code — click a citation to read the verbatim passage:

  • CWUIC § 603.2 High relevance — show source text

    603.2 Application. All new plantings of vegetation in State Responsibility Area (SRA) and Local Responsibility Areas (LRA) designated as a Fire Hazard Severity Zone shall comply with Sections 603.3 through 603.4.2.1.

    603.3 Landscape plans. Landscape plans shall be provided when required by the code official. The landscape plan shall include devel- opment and maintenance requirements for the vegetation management zone adjacent to structures and roadways, and provide significant fire hazard reduction benefits for public and firefighting safety.

    603.3.1 Contents. Landscape plans shall contain the following: 1. Delineation of the 30-foot (9144 mm) and 100-foot (30 480 mm) fuel management zones from all structures. 2. Identification of existing vegetation to remain and proposed new vegetation. 3. Identification of irrigated areas. 4. A plant legend with both botanical and common names, and identification of all plant material symbols. 5. Identification of ground coverings within the 30-foot (9144 mm) zone.

    603.4 Vegetation. All new vegetation shall be fire-smart vegetation in accordance with this section.

    Exception: Trees classified as nonfire-smart vegetation complying with Section 603.4.2.1.

    To be considered fire-smart vegetation, vegetation must meet at least one of the following: 1. Be identified as fire-smart vegetation in an approved book, journal or listing from an approved organization. 2. Be identified as fire-smart vegetation by a licensed landscape architect with supporting justification. 3. Plants considered fire-smart vegetation and approved by the local enforcing agency.

    603.4.1 Shrubs. All new plantings of shrubs shall comply with the following: 1. Shrubs shall not exceed 6 feet (1829 mm) in height. 2. Groupings of shrubs are limited to a maximum aggregate diameter of 10 feet (3048 mm). 3. Shrub groupings shall be separated from other groupings a minimum of 15 feet (4572 mm). 4. Shrub groupings shall be separated from structures a minimum of 30 feet (9144 mm). 5. Where shrubs are located below or within a tree’s drip line, the lowest tree branch shall be a minimum of three times the height of the understory shrubs or 10 feet (3048 mm), whichever is greater.

    603.4.2 Trees. Trees shall be managed as follows within the 30-foot zone (9144 mm) of a structure: 1. New trees shall be planted and maintained so that the tree’s drip line at maturity is a minimum of 10 feet (3048 mm) from any combustible structure. 2. The horizontal distance between crowns of new trees and crowns of adjacent trees shall not be less than 10 feet (3048 mm). 3. Existing trees shall be trimmed to provide a minimum separation of 10 feet (3048 mm) away from chimney and stovepipe outlets per California Code of Regulations, Title 14, Section 1299.03.

  • CWUIC § B101 High relevance — show source text

    SECTION B101—GENERAL

    B101.1 Scope. Vegetation management plans shall be submitted to the code official for review and approval as part of the plans required for a permit.

    B101.2 Plan content. Vegetation management plans shall describe all actions that will be taken to prevent a fire from being carried toward or away from the building. A vegetation management plan shall include the following information:

    1. A copy of the site plan.
    2. Methods and timetables for controlling, changing or modifying areas on the property. Elements of the plan shall include removal of slash, snags, vegetation that may grow into overhead electrical lines, other ground fuels, ladder fuels and dead trees, and the thinning of live trees.
    3. A plan for maintaining the proposed fuel-reduction measures.

    B101.3 Fuel modification. To be considered a fuel modification for purposes of this code, continuous maintenance of the clearance is required.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA WILDLAND-URBAN INTERFACE CODE – MATRIX ADOPTION TABLE APPENDIX C – COMMUNITY WILDLAND-URBAN INTERFACE (WUI) FIRE HAZARD EVALUATION FRAMEWORK

    (Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)

    (Not adopted by the State Fire Marshal)

    Adopting Agency BSC BSC-
    CG
    SFM Col5 HCD Col7 Col8 DSA Col10 OSHPD Col12 Col13 Col14 Col15 Col16 BSCC DPH AGR DWR CEC CA SL SLC
    Adopting Agency BSC BSC-
    CG
    T-24 T-19* 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5
    Adopt Entire Chapter
    Adopt Entire Chapter as
    amended (amended sections
    listed below)
    Adopt only those sections that
    are listed below
    [California Code of Regulations,
    Title 19, Division 1]
    Chapter / Section
  • CWUIC § 1.11. High relevance — show source text
    • The California Code of Regulations (CCR), Title 19, Division 1 provisions that are found in the California Wildland-Urban Interface Code are a reprint from the current CCR, Title 19, Division 1 text for the code user’s convenience only. The scope, applicability and appeals procedures of CCR, Title 19, Division I remain the same. The state agency does not adopt sections identified by the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.

    The California Code of Regulations (CCR), Title 14, Division 1.5 provisions that are found in the California Wildland-Urban Interface Code are not listed in the Matrix Adoption Tables as they are not within the State Fire Marshal’s authority to adopt. These provisions are a reprint from the current CCR, Title 14, Division 1.5 text for the code user’s convenience only and are identified in the body of the code by square brackets containing references to applicable Title 14 sections.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-2 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    B VEGETATION MANAGEMENT PLAN

    The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.

    User notes:

    About this appendix: Appendix B, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide criteria for submitting vegetation management plans, specifying their content and establishing a criterion for considering vegetation management as being a fuel modification.

    SECTION B101—GENERAL

    B101.1 Scope. Vegetation management plans shall be submitted to the code official for review and approval as part of the plans required for a permit.

    B101.2 Plan content. Vegetation management plans shall describe all actions that will be taken to prevent a fire from being carried toward or away from the building. A vegetation management plan shall include the following information:

    1. A copy of the site plan.
    2. Methods and timetables for controlling, changing or modifying areas on the property. Elements of the plan shall include removal of slash, snags, vegetation that may grow into overhead electrical lines, other ground fuels, ladder fuels and dead trees, and the thinning of live trees.
    3. A plan for maintaining the proposed fuel-reduction measures.

    B101.3 Fuel modification. To be considered a fuel modification for purposes of this code, continuous maintenance of the clearance is required.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX B-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX B-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CALIFORNIA WILDLAND-URBAN INTERFACE CODE – MATRIX ADOPTION TABLE APPENDIX C – COMMUNITY WILDLAND-URBAN INTERFACE (WUI) FIRE HAZARD EVALUATION FRAMEWORK

  • CWUIC § 6-3 High relevance — show source text

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FIRE PROTECTION REQUIREMENTS

    602.3.2 Final fire protection plan. Final fire protection plan shall include items listed in Section 602.3.1 and the following: 1. A map identifying all proposed plants in the fuel modification zones with a legend that includes a symbol for each proposed plant species. The plan shall include specific information on each species proposed, including but not limited to: 1.1. The plant life-form;

    1.2. The scientific and common name; and

    1.3. The expected height and width for mature growth. 2. Identification of irrigated and nonirrigated zones. 3. Requirements for vegetation reduction around emergency access and evacuation routes. 4. Identification of points of access for equipment and personnel to maintain vegetation in common areas. 5. Legally binding statements regarding community responsibility for maintenance of fuel modification zones. 6. Legally binding statements to be included in covenants, conditions and restrictions regarding property owner responsibili- ties for vegetation maintenance.

    SECTION 603— VEGETATION PLAN

    603.1 General. Planting of vegetation for new landscaping shall be selected to reduce vegetation in proximity to a structure and to maintain vegetation as it matures.

    603.2 Application. All new plantings of vegetation in State Responsibility Area (SRA) and Local Responsibility Areas (LRA) designated as a Fire Hazard Severity Zone shall comply with Sections 603.3 through 603.4.2.1.

    603.3 Landscape plans. Landscape plans shall be provided when required by the code official. The landscape plan shall include devel- opment and maintenance requirements for the vegetation management zone adjacent to structures and roadways, and provide significant fire hazard reduction benefits for public and firefighting safety.

    603.3.1 Contents. Landscape plans shall contain the following: 1. Delineation of the 30-foot (9144 mm) and 100-foot (30 480 mm) fuel management zones from all structures. 2. Identification of existing vegetation to remain and proposed new vegetation. 3. Identification of irrigated areas. 4. A plant legend with both botanical and common names, and identification of all plant material symbols. 5. Identification of ground coverings within the 30-foot (9144 mm) zone.

    603.4 Vegetation. All new vegetation shall be fire-smart vegetation in accordance with this section.

    Exception: Trees classified as nonfire-smart vegetation complying with Section 603.4.2.1.

    To be considered fire-smart vegetation, vegetation must meet at least one of the following: 1. Be identified as fire-smart vegetation in an approved book, journal or listing from an approved organization. 2. Be identified as fire-smart vegetation by a licensed landscape architect with supporting justification. 3. Plants considered fire-smart vegetation and approved by the local enforcing agency.

  • CWUIC § 603.4.1 High relevance — show source text

    603.4.1 Shrubs. All new plantings of shrubs shall comply with the following: 1. Shrubs shall not exceed 6 feet (1829 mm) in height. 2. Groupings of shrubs are limited to a maximum aggregate diameter of 10 feet (3048 mm). 3. Shrub groupings shall be separated from other groupings a minimum of 15 feet (4572 mm). 4. Shrub groupings shall be separated from structures a minimum of 30 feet (9144 mm). 5. Where shrubs are located below or within a tree’s drip line, the lowest tree branch shall be a minimum of three times the height of the understory shrubs or 10 feet (3048 mm), whichever is greater.

    603.4.2 Trees. Trees shall be managed as follows within the 30-foot zone (9144 mm) of a structure: 1. New trees shall be planted and maintained so that the tree’s drip line at maturity is a minimum of 10 feet (3048 mm) from any combustible structure. 2. The horizontal distance between crowns of new trees and crowns of adjacent trees shall not be less than 10 feet (3048 mm). 3. Existing trees shall be trimmed to provide a minimum separation of 10 feet (3048 mm) away from chimney and stovepipe outlets per California Code of Regulations, Title 14, Section 1299.03.

    603.4.2.1 Nonfire-smart vegetation. New trees not classified as fire-smart vegetation, such as conifers, palms, pepper trees and eucalyptus species, shall be permitted provided the tree is planted and maintained in accordance with one of the following: 1. The tree is planted so that the tree’s drip line at maturity is a minimum of 30 feet (9144 mm) from an applicable building. 2. The tree is planted so that the tree’s drip line at maturity is a minimum of 10 feet (3048 mm) from any combustible struc- ture, and is well pruned and maintained so as not to form a means of rapidly transmitting fire from other nearby vegetation to the structure or from the structure to nearby vegetation or to interrupt the advance of embers toward a

    structure.

    6-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FIRE PROTECTION REQUIREMENTS

    SECTION 604—MAINTENANCE OF DEFENSIBLE SPACE

    604.1 General. Hazardous vegetation and fuels shall be managed to reduce the severity of potential exterior wildfire exposure to build- ings and to reduce the risk of fire spreading to buildings as required by applicable laws and regulations.

    Defensible space shall be managed around all buildings and structures in State Responsibility Areas (SRA) as required in Public Resources Code 4291.

    604.2 Application. Buildings and structures located in the following areas shall maintain the required hazardous vegetation and fuel management: 1. All unincorporated lands designated as a State Responsibility Area (SRA). 2. Land designated as a Very High Fire Hazard Severity Zone by a city or local agency. 3. Land designated in a city or local agency ordinance as a wildland-urban interface (WUI) area.

  • CWUIC § 102.4 High relevance — show source text

    The chapter includes mitigation strategies to reduce the hazards of fire originating within a structure spreading to wildland and fire originating in wildland spreading to structures.

    Chapter 7 Referenced Standards.

    Chapter 7 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 6 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.

    Appendix A General Requirements.

    Appendix A, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide fire-protection measures supplemental to those found in Chapter 6 to reduce the threat of wildfire in a wildland-urban interface area and improve the capability for controlling such fires. This appendix includes detailed requirements for vegetation control; the code official’s authority to close wildland-interface areas in times of high fire danger; control of fires, fireworks usage and other sources of ignition; storage of hazardous materials and combustibles; bans on the dumping of waste materials and ashes and coals in wildlandurban interface areas; protection of pumps and water supplies; and limits on temporary uses within the wildland-urban interface area.

    Appendix B Vegetation Management Plan.

    Appendix B, while not part of the code, can become part of the code when specifically included in the adopting ordinance. Its purpose is to provide criteria for submitting vegetation management plans, specifying their content and establishing a criterion for considering vegetation management as being a fuel modification.

    Appendix C Community Wildland-Urban Interface (WUI) Fire Hazard Evaluation Framework.

    Appendix C contains a preliminary Community WUI Fire Hazard Evaluation Framework as a suggested methodology to begin to support communities at risk in the identification of their unique hazards and to provide common metrics for comparisons between communities. This preliminary framework includes information on community size, population and fuels; on notification and evacuation; and on the community infrastructure and firefighting response potential. Aspects of this framework may already be included in various community- level documents, such as Community Wildfire Protection Plans or evacuation plans. Development of a standard framework will (1) consolidate relevant WUI fire hazard and planning information in one place, and (2) allow for cross-community comparisons.

    The evaluation required to implement this framework will support prefire hazard assessment and during-fire response operations. An increased understanding of fire evacuation, fire structural response and fire defensive action relationships is needed to assess the over- all community WUI fire hazard. The quantification of these relationships will enable communities to optimize the community-level response to WUI fire hazards in a more integrated approach and result in increased life safety and reduced losses.

    Appendix D Model Ordinance for Fire Hazard Severity Zone Adoption.

    Appendix D is an informational appendix that is a sample ordinance designed as guidance for a city, county, city and county, or fire district to establish and designate fire hazard severity zones within their jurisdiction.

    Appendix E Reserved.

    Appendix F Characteristics of Fire-Smart Vegetation.

    Appendix F is an informational appendix provided for the convenience of the code user. It is simply a compilation of the eight characteristics of fire-smart vegetation that can be used effectively within wildland-urban interface areas to reduce the likelihood of fire spread through vegetation.

    **App

  • CWUIC § 1299.04 High relevance — show source text

    of defensible space clearance shall be maintained in two distinct “Zones” as follows: “Zone 1” extends thirty_ feet (30 ft.) out from each “Building or Structure,” or to the property line, whichever comes first; “Zone 2” extends from thirty feet (30 ft.) to one hundred feet (100 ft.) from each “Building or Structure,” but not beyond the property line. The vegetation treatment requirements for Zone 1 are more restrictive than for Zone 2, as provided in (a) and (b) below. The Department of Forestry and Fire Protection's “Prop- erty Inspection Guide, 2000 version, April 2000,” provides additional guidance on vegetation treatment within Zone 1 and Zone 2, but is not mandatory and is not intended as a substitute for these regulations. (a) Zone 1 Requirements: (1) Remove all dead or dying grass, plants, shrubs, trees, branches, leaves, weeds, and pine needles from the Zone whether such vegetation occurs in yard areas around the “Building or Structure,” on the roof or rain gutters of the “Building or Structure,” or any other location within the Zone. (2) Remove dead tree or shrub branches that overhang roofs, below or adjacent to windows, or which are adjacent to wall surfaces, and keep all branches a minimum of ten feet (10 ft.) away from chimney and stovepipe outlets. (3) Relocate exposed firewood piles outside of Zone 1 unless they are completely covered in a fire resistant material. (4) Remove flammable vegetation and items that could catch fire which are adjacent to or under combustible decks, balco- nies and stairs.

    (b) Zone 2 Requirements: (1) In this zone create horizontal and vertical spacing among shrubs and trees using the “Fuel Separation” method, the “Continuous Tree Canopy” method or a combination of both to achieve defensible space clearance requirements. Further guidance regarding these methods is contained in the State Board of Forestry and Fire Protection's, “General Guidelines for Creating Defensible Space, February 8, 2006,” incorporated herein by reference, and the “Property Inspec- tion Guide” referenced elsewhere in this regulation. (2) In both the Fuel Separation and Continuous Tree Canopy methods the following standards apply: (A) Dead and dying woody surface fuels and aerial fuels shall be removed. Loose surface litter, normally consisting of fallen leaves or needles, twigs, bark, cones, and small branches, shall be permitted to a maximum depth of three inches (3 in.). (B) Cut annual grasses and forbs down to a maximum height of four inches (4 in.). (C) All exposed wood piles must have a minimum of ten feet (10 ft.) of clearance, down to bare mineral soil, in all directions.

    (c) For both Zones 1 and 2: (1) “Outbuildings” and Liquid Propane Gas (LPG) storage tanks shall have the following minimum clearance: ten feet (10 ft.) of clearance to bare mineral soil and no flammable vegetation for an additional ten feet (10 ft.) around their exterior. (2) Protect water quality. Do not clear vegetation to bare mineral soil and avoid the use of heavy equipment in and around streams and seasonal drainages. Vegetation removal can cause soil erosion, especially on steep slopes. Keep soil distur- bance to a minimum on steep slopes.

    1299.04 Additional clearance.

  • CWUIC § 6-1 High relevance — show source text

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 6-1

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6-2 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    6 FIRE PROTECTION REQUIREMENTS

    User notes:

    About this chapter: In addition to the building construction requirements in the California Building Code and California Residential Code, this chapter contains requirements for development and construction in Local Responsibility Areas (LRA) designated as Very High Fire Hazard Severity Zones and areas designated by the State Fire Marshal as State Responsibility Areas (SRA). While many of these provisions are found in Title 14 and Title 19 of the California Code of Regulations, they are replicated here for the code user. The local jurisdiction has the authority to apply the same regulations to LRA when the regulations are adopted by local ordinance.

    The requirements in this chapter reference the process for adoption of Very High Fire Hazard Severity Zones in the LRA; criteria for evaluating existing subdivisions that are at significant fire risk and are without an adequate secondary egress; and criteria for fire safety provisions required in the Safety Element of a city or county General Plan.

    The chapter includes mitigation strategies to reduce the hazards of fire originating within a structure spreading to wildland and fire originating in wildland spreading to structures. These strategies are included in the following requirements:

    1. Development of fire protection plans.

    2. Development of landscape plans and long-term vegetation management.

    3. Creation and maintenance of defensible space to protect structures and subdivisions.

    SECTION 601—GENERAL

    601.1 Scope. The provisions of this chapter establish general requirements for new and existing buildings, structures and premises located within wildland-urban interface (WUI) areas .

    601.2 Objective. The objective of this chapter is to establish minimum requirements to mitigate conditions that might cause a fire originating in a structure to ignite vegetation in the wildland-urban interface (WUI) area, and conversely, a wildfire burning in vegetative fuels to transmit fire to buildings and threaten to destroy life, overwhelm fire suppression capabilities or result in large property losses.

    601.3 Chapter 6 definitions. Where used in this chapter, the term listed below shall be defined as follows:

    DEFENSIBLE SPACE. The buffer that landowners are required to create on their property between a “Building or Structure” and the plants, brush and trees or other items surrounding the “Building or Structure” that could ignite in the event of a fire. [CCR Title 14 §1299.02(a)]

    SECTION 602— FIRE PROTECTION PLANS

    602.1 General. The code official is authorized to require the owner or owner’s authorized agent to provide a fire protection plan. The fire protection plan shall be prepared to determine the acceptability of fire protection and life safety measures designed to mitigate wildfire hazards presented for the property under consideration.

    The fire protection plan shall be prepared by a registered design professional, qualified landscape architect, qualified fire safety specialist or similar specialist acceptable to the code official and shall analyze the wildfire risk of the building, project, premises or region to recommend necessary changes.

    The code official is authorized to require a preliminary fire protection plan prior to the submission of a final fire protection plan.

  • CWUIC § 6-4 High relevance — show source text

    structure.

    6-4 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    FIRE PROTECTION REQUIREMENTS

    SECTION 604—MAINTENANCE OF DEFENSIBLE SPACE

    604.1 General. Hazardous vegetation and fuels shall be managed to reduce the severity of potential exterior wildfire exposure to build- ings and to reduce the risk of fire spreading to buildings as required by applicable laws and regulations.

    Defensible space shall be managed around all buildings and structures in State Responsibility Areas (SRA) as required in Public Resources Code 4291.

    604.2 Application. Buildings and structures located in the following areas shall maintain the required hazardous vegetation and fuel management: 1. All unincorporated lands designated as a State Responsibility Area (SRA). 2. Land designated as a Very High Fire Hazard Severity Zone by a city or local agency. 3. Land designated in a city or local agency ordinance as a wildland-urban interface (WUI) area.

    604.3 Requirements. Hazardous vegetation and fuels around all buildings and structures shall be maintained in accordance with the following laws and regulations: 1. Public Resources Code, Section 4291.

    2. California Code of Regulations, Title 14, Division 1.5, Chapter 7, Subchapter 3, Article 3, Section 1299.03. 3. California Government Code, Section 51182.

    4. California Code of Regulations, Title 19, Division 1, Chapter 7, Subchapter 1, Section 3.07.

    604.4 Outbuildings. Outbuildings shall have a minimum clearance of 10 feet (3048 mm) down to bare mineral soil in all directions. Vege- tation more than 10 feet (3048 mm) but less than 20 feet (6096 mm) from outbuildings shall be fire-smart vegetation.

    604.5 Disposal of flammable vegetation and fuels. The disposal, including burning or removal to a site approved by the local jurisdic- tion in consultation with the fire authority, of flammable vegetation and fuels caused by site, road and driveway construction shall be in accordance with all applicable laws and regulations. [CCR T14 §1276.05]

    SECTION 605—SPARK ARRESTORS

    605.1 General. Chimneys serving fireplaces, barbecues, incinerators or decorative heating appliances in which solid or liquid fuel is used shall be provided with a spark arrestor. Spark arrestors shall be constructed of woven or welded wire screening of 12 USA standard gage wire (0.1046 inch) (2.66 mm) having openings not exceeding [1] / 2 inch (12.7 mm).

    605.2 Net free area. The net free area of the spark arrestor shall be not less than four times the net free area of the outlet of the chimney.

    SECTION 606—LIQUEFIED PETROLEUM GAS INSTALLATIONS

    606.1 General. The storage of liquefied petroleum gas (LP-gas) and the installation and maintenance of pertinent equipment shall be in accordance with the California Fire Code .

    606.2 Location of containers or tanks. LP-gas containers or tanks shall be located within the defensible space in accordance with the California Fire Code .

  • CWUIC § 4291 High relevance — show source text

    4291.

    (a) A person who owns, leases, controls, operates, or maintains a building or structure in, upon, or adjoining a mountainous area, forest-covered lands, shrub-covered lands, grass-covered lands, or land that is covered with flammable material, shall at all times do all of the following: (1) (A) Maintain defensible space of 100 feet from each side and from the front and rear of the structure, but not beyond the property line, except as provided in subparagraph (B). The amount of fuel modification necessary shall consider the flammability of the structure as affected by building material, building standards, location, and type of vegetation. Fuels shall be maintained and spaced in a condition so that a wildfire burning under average weather conditions would be unlikely to ignite the structure. This subparagraph does not apply to single specimens of trees or other vege- tation that are well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fire from other nearby vegetation to a structure or from a structure to other nearby vegetation or to interrupt the advance of embers toward a structure. The intensity of fuels management may vary within the 100-foot perimeter of the structure, with more intense fuel reductions being utilized between 5 and 30 feet around the struc- ture, and an ember-resistant zone being required within 5 feet of the structure, based on regulations promulgated by the board, in consultation with the department, to consider the elimination of materials in the ember-resistant zone that would likely be ignited by embers. Consistent with fuels management objectives, steps should be taken to mini- mize erosion, soil disturbance, and the spread of flammable nonnative grasses and weeds. For purposes of this subparagraph, “fuel” means any combustible material, including petroleum-based products, cultivated landscape plants, grasses, and weeds, and wildland vegetation. (B) A greater distance than that required under subparagraph (A) may be required by state law, local ordinance, rule, or regulation. Fuel modification beyond the property line may only be required by state law, local ordinance, rule, or regulation in order to maintain 100 feet of defensible space from a structure. Fuel modification on adjacent property shall only be conducted following written consent by the adjacent landowner. Any local ordinance related to fuel modification shall be in compliance with all applicable state laws, regulations, and policies. Any local ordinance may include provisions to allocate costs for any fuel modification beyond the property line.

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX H-7

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    APPENDIX H—REFERENCED CALIFORNIA DOCUMENTS

    (C) An insurance company that insures an occupied dwelling or occupied structure may require a greater distance than that required under subparagraph (A) if a fire expert, designated by the director, provides findings that the fuel modi- fication is necessary to significantly reduce the risk of transmission of flame or heat sufficient to ignite the structure, and there is no other feasible mitigation measure possible to reduce the risk of ignition or spread of wildfire to the structure. The greater distance may not be beyond the property line unless allowed by state law, local ordinance, rule, or regulation. (2) Remove that portion of a tree that extends within 10 feet of the outlet of a chimney or stovepipe. (3) _Maintain a tree, shrub,

  • CWUIC § 2025 High relevance — show source text

    A104 Ignition Source Control . . . . . . . . . . . . . . APPENDIX A-5

    A105 Control of Storage . . . . . . . . . . . . . . . . . . . APPENDIX A-5

    A106 Dumping . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A-6

    A107 Protection of Pumps and Water Storage Facilities. . . . . . . . . . . . . . . . . APPENDIX A-6

    A108 Land Use Limitations . . . . . . . . . . . . . . . . APPENDIX A-6

    A109 Referenced Standards . . . . . . . . . . . . . . . APPENDIX A-7

    APPENDIX B VEGETATION MANAGEMENT

    PLAN . . . . . . . . . . . . . . . . . . . . . . APPENDIX B-3

    B101 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX B-3

    APPENDIX C COMMUNITY WILDLAND-URBAN

    INTERFACE (WUI) FIRE HAZARD

    EVALUATION FRAMEWORK . . . . APPENDIX C-3

    C101 Community WUI Hazard Evaluation Framework . . . . . . . . . . . . . . . . . . . . . . APPENDIX C-3

    APPENDIX D MODEL ORDINANCE FOR FIRE HAZARD

    SEVERITY ZONE ADOPTION . . . . APPENDIX D-3

    D101 Model Ordinance for Designation of Fire Hazard Severity Zones in Local Responsibility Areas (LRA) . . . . . . . . . . . . . . . . . . . . . . . APPENDIX D-3

    APPENDIX E RESERVED . . . . . . . . . . . . . . . . . . APPENDIX E-1

    APPENDIX F CHARACTERISTICS OF FIRE-SMART

    VEGETATION . . . . . . . . . . . . . . . . APPENDIX F-3

    F101 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX F-3

    2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE xiii

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CONTENTS

    APPENDIX G VOLUNTARY HOME-HARDENING

    RECOMMENDATIONS . . . . . . . . . . APPENDIX G-3

    G101 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX G-3

    APPENDIX H REFERENCED CALIFORNIA

    DOCUMENTS . . . . . . . . . . . . . . . .APPENDIX H-3

Frequently asked questions

What distance must I maintain for defensible space around a structure?

The baseline is 100 feet from the structure (or to the property line) as described in Public Resources Code §4291; within that perimeter, more intense reductions are expected between 5 and 30 feet and an ember‑resistant zone is required within 5 feet when regulations are in effect §4291 and CWUIC §604.3 provide the implementing references .

When does the code require a vegetation or landscape plan and what must it show?

The code official may require landscape and vegetation management plans; when required the landscape plan must delineate the 30‑ and 100‑foot fuel management zones, identify existing and proposed plants, irrigated areas, a plant legend (botanical and common names), and groundcover within the 30‑ft zone (§603.3.1). Appendix B describes vegetation management plan content and maintenance requirements for fuel modifications (B101.1–B101.3) .

What is “fire‑smart” vegetation and where is it described?

Appendix F lists eight characteristics of fire‑smart vegetation (F101.1) — for example, low accumulation of dead material, high live‑fuel moisture, lack of ladder fuels, and low overall fuel volume — and §603.4 explains how plants are approved as fire‑smart (listed by an approved source, identified by a licensed landscape architect, or approved by the local enforcing agency) .