(a)

Except for vehicular access door, all exterior swinging doors of any residential building and attached garages, including the door leading from the garage area into the dwelling unit shall be equipped as follows:

(1)

All wood doors shall be of solid core construction with a minimum thickness of one and three-fourths (1¾) inches, or with panels not less than nine-sixteenths inch thick.

(2)

A single or double door shall be equipped with a double or single cylinder deadbolt lock. The bolt shall have a minimum projection of one (1) inch and be constructed so as to repeal cutting tool attack. The deadbolt shall have an embedment of at least three-fourths inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five (5) pin tumblers, and shall be connected to the inner portion of the lock by connected screws of at least one-fourth inch in diameter. All installation shall be

done so that the performance of the locking device will meet the intended antiburglary requirements. A dual locking mechanism constructed so that both deadbolt and latch can be retracted by a single action of the inside door knob, or lever, may be substituted provided it meets all other specifications for locking devices.

(3)

The inactive leaf of double door(s) shall be equipped with metal flush bolts having a minimum embedment of five-eights inch into the head and threshold or the door frame.

(4)

Glazing in exterior doors or within forty (40) inches of any locking mechanism shall be of fully tempered glass or rated burglary-resistant glazing, except when double cylinder deadbolt locks are installed.

(5)

Except where clear vision panels are installed, all front exterior doors shall be equipped with a wide angle (180°) door viewer.

(b)

Street numbers and other identifying data shall be displayed as follows:

(1)

All residential dwellings shall display a street number in a prominent location on the street side of the residence in such a position that the number is easily visible to approaching emergency vehicles. The numerals shall be no less than four (4) inches in height and shall be of a contrasting color to the background to which they are attached.

(2)

There shall be positioned at each entrance of a multiple-family dwelling complex an illuminated diagrammatic representation of the complex which shows the location of the viewer and the unit designations within the complex. In addition, each individual unit within the complex shall display a prominent identification number, not less than four (4) inches in height, which is easily visible to approaching vehicular and/or pedestrian traffic.

(c)

Lighting in multiple-family dwellings shall be as follows:

(1)

Aisles, passageways and recesses related to and within the building complex shall be illuminated with an intensity of at least twenty-five one-hundredths (0.25) footcandles at the ground level during the hours of darkness. Lighting devices shall be protected by weather and vandalism resistant covers.

(2)

Open parking lots and carports shall be provided with a maintained minimum of one (1) footcandle of light on the parking surface during the hours of darkness. Lighting devices shall be protected by weather and vandalism resistant covers.

(Ord. No. 1538. § 1, 3-8-82)

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — West Covina Building Code
West Covina Building Code
  1. ▸Chapter 7 — BUILDINGS AND BUILDING REGULATIONS
    Overview
    1. Sec. 7-1. - Definition of terms.
    2. Sec. 7-2. - Fees.
    3. Sec. 7-16. - Adoption of Title 26 (Building Code) of Los Angel…
    4. Sec. 7-17. - Board of appeals.
    5. Sec. 7-18. - Expiration and extension of applications.
    6. Sec. 7-19. - Fees and refunds.
    7. Sec. 7-20. - Use and occupancy.
    8. Sec. 7-21. - Roof coverings.
    9. Sec. 7-22. - Fire protection and life safety systems.
    10. Sec. 7-23. - Swimming pool safety.
    11. Sec. 7-24. - Violations and penalties.
    12. Sec. 7-38. - Adoption of Title 30 (Residential Code) of Los An…
    13. Sec. 7-39. - Roof coverings.
    14. Sec. 7-40. - Automatic fire sprinkler systems.
    15. Sec. 7-41. - Violations and penalties.
    16. Sec. 7-50. - Adoption of Title 27 (Electrical Code) of Los Ang…
    17. Sec. 7-51. - Fees, refunds, and expiration.
    18. Sec. 7-52. - Violations and penalties.
    19. Sec. 7-61. - Adoption of Title 33 (Existing Building Code) of …
    20. Sec. 7-62. - Violations and penalties.
    21. Sec. 7-74. - Adoption of Title 29 (Mechanical Code) of Los Ang…
    22. Sec. 7-75. - Fees, refunds, and expiration.
    23. Sec. 7-76. - Violations and penalties.
    24. Sec. 7-85. - Adoption of Title 28 (Plumbing Code) of Los Angel…
    25. Sec. 7-86. - Fees, refunds, and expiration.
    26. Sec. 7-87. - Violations and penalties.
    27. Sec. 7-98. - Moving a building on the same lot.
    28. Sec. 7-99. - Abrogation of other requirements.
    29. Sec. 7-111. - Required.
    30. Sec. 7-112. - Relocation permit fees.
    31. Sec. 7-113. - Approval of application.
    32. Sec. 7-114. - Review of application to relocate buildings into…
    33. Sec. 7-168. - Water system required.
    34. Sec. 7-169. - Reimbursement agreement.
    35. Sec. 7-170. - Existing facilities.
    36. Sec. 7-171. - Same—Preparation of map.
    37. Sec. 7-183. - Definitions.
    38. Sec. 7-184. - Streets and highways; dedication required.
    39. Sec. 7-185. - Construction of street improvements—Required; ex…
    40. Sec. 7-186. - Same—Prerequisite to approval of the building of…
    41. Sec. 7-187. - Same—Construction agreement.
    42. Sec. 7-188. - Adequate street lighting—Owner's responsibility.
    43. Sec. 7-189. - Same—Reimbursement agreement.
    44. Sec. 7-190. - Sidewalks—General requirements.
    45. Sec. 7-191. - Same—Location.
    46. Sec. 7-192. - Sidewalk widths.
    47. Sec. 7-200. - Application of article.
    48. Sec. 7-201. - Reimbursement agreement.
    49. Sec. 7-202. - Collection of reimbursement.
    50. Sec. 7-220. - Adopted.
    51. Sec. 7-221. - Reserved.
    52. Sec. 7-223. - Guidelines for solar photovoltaic installation.
    53. Sec. 7-230. - Purpose.
    54. Sec. 7-231. - Scope.
    55. Sec. 7-232. - Definitions.
    56. Sec. 7-233. - Enforcement provisions.
    57. Sec. 7-234. - Right of entry.
    58. Sec. 7-235. - Violations and penalties.
    59. Sec. 7-236. - Appeals.
    60. Sec. 7-237. - Alternate materials and methods of construction.
    61. Sec. 7-238. - Key requirements.
    62. Sec. 7-239. - Frames/jambs/strikes/hinges.
    63. Sec. 7-240. - Windows/sliding glass doors.
    64. Sec. 7-241. - Garage type doors: Rolling overhead, solid overh…
    65. Sec. 7-242. - Special residential building provisions.
    66. Sec. 7-243. - Special commercial building provisions.
    67. Sec. 7-244. - Tests.
    68. Sec. 7-250. - Guidelines adopted.
    69. Sec. 7-251. - Reserved.
    70. Sec. 7-260. - Title.
    71. Sec. 7-261. - Covered projects.
    72. Sec. 7-262. - Waste diversion plan (WDP).
    73. Sec. 7-263. - The administrative cost-recovery fee.
    74. Sec. 7-264. - Performance security deposit and refund.
    75. Sec. 7-265. - Diversion requirements exemption.
    76. Sec. 7-266. - Authority and enforcement.
    77. Sec. 7-267. - Hazardous or toxic C&D debris.
    78. Sec. 7-268. - Applicability of other laws.
    79. Sec. 7-269. - Reserved.
    80. Sec. 7-270. - Title.
    81. § 7-280
    82. Sec. 7-330. - Purpose.
    83. Sec. 7-331. - Definitions.
    84. Sec. 7-332. - Model water efficient landscaping ordinance requ…

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.