12.05.01 - Intent.¶
This chapter establishes standard placards to be used to indicate the condition of a structure for continued occupancy. The chapter further authorizes the Chief Building Official and his or her authorized representative to post the appropriate placard at each entry point to a building or structure upon completion of a safety assessment. This can be due to a large scale natural event, a single accident, or dilapidated property maintenance, which may cause harm or jeopardize the safety of the occupant.
(Ord. 1601 N.C.(2d) § 4.01, 2007.)
12.05.02 - Application of provisions.¶
The provisions of this chapter are applicable to all buildings and structures of all occupancies regulated by the city of Vallejo. The city council may extend the provisions as necessary.
(Ord. 1601 N.C.(2d) § 4.02, 2007.)
12.05.03 - Definitions.¶
"Safety assessment" means a visual, nondestructive examination of a building or structure for the purpose of determining the condition for continued occupancy.
(Ord. 1601 N.C.(2d) § 4.03, 2007.)
12.05.04 - Placards.¶
A.
The following is verbal description of the official jurisdiction placards to be used to designate the condition for the continued occupancy of buildings or structures.
1.
INSPECTED — Lawful Occupancy Permitted is to be posted on any building or structure wherein no apparent structural hazard has been found. The placard is not intended to mean that there is no damage to the building or structure.
2.
RESTRICTED USE is to be posted on each building or structure that has been damaged wherein the damage has resulted in some form of restrictions to the continued occupancy. The individual who posts this placard will note in general terms the type of damage encountered and will clearly note the restrictions on continued occupancy.
3.
UNSAFE — Do Not Enter or Occupy is to be posted on each building or structure that has been damaged such that continued occupancy poses a threat to life safety. Buildings or structures posted with this placard shall not be entered under any circumstance except as authorized in writing by the chief building official, or his or her authorized representative. Safety assessment teams shall be authorized to enter these buildings at any time. This placard is not to be used or considered as a demolition order. The individual who posts this placard will note in general terms the type of damage encountered.
B.
This ordinance number, the name of the jurisdiction, its address, and phone number shall be permanently affixed to each placard.
C.
Once it has been attached to a building or structure, a placard is not to be removed, altered or covered until done so by an authorized representative of the chief building official. It shall be unlawful for any person, firm or corporation to alter, cover or deface a placard pursuant to this section.
(Ord. 1601 N.C.(2d) § 4.04, 2007.)
Chapter 12.06 - ABATEMENT OF DANGEROUS BUILDINGS CODE
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Vallejo Building Code
▸Title 12 — BUILDINGS AND CONSTRUCTION
Overview▸Chapter 12.04 — BUILDING CODE ADOPTED
Overview- Chapter 12.05 — PLACARDS USED TO DENOTE CONDITIONS RELATED TO …
- Chapter 12.06 — ABATEMENT OF DANGEROUS BUILDINGS CODE
- Section 203.2 Penalties.
- Chapter 12.07 — SEISMIC HAZARD IDENTIFICATION AND MITIGATION P…
- Chapter 12.08 — PROPERTY MAINTENANCE CODE ADOPTED
- Chapter 12.12 — ELECTRICAL CODE ADOPTED
- Chapter 12.16 — PLUMBING CODE ADOPTED
- Chapter 12.20 — MECHANICAL CODE ADOPTED
- Chapter 12.24 — UNDERGROUND UTILITY INSTALLATIONS
- Chapter 12.28 — FIRE CODE ADOPTED
- Chapter 12.30 — RESIDENTIAL BUILDING CODE ADOPTED
- Chapter 12.32 — ENERGY CODE ADOPTED
- Chapter 12.36 — SIGNS
- Chapter 12.48 — EXISTING BUILDING CODE ADOPTED
- Title 12 — FOOTNOTES