Chapter 18.26 — Downtown Form-Based Code
8.2 Standards (continued)
Santa Clara Zoning Code · 2026-06 edition · updated 2026-07-25 · Santa Clara
- F. Expressing Visual Weight and Load-Bearing Structure. To ensure that new development in downtown is compatible with the historic building fabric and visual structural principles of Downtown Santa Clara, the following standards apply to the building structure, architectural elements, and materials and color:
==> picture [261 x 356] intentionally omitted <==
----- Start of picture text -----
Bay
----- End of picture text -----
Vertical structural elements frame the bay; visual weight within the bay is transferred clearly to the ground.
1. Building Structure. To express the load-bearing structural characteristics of traditional downtown buildings, the following standards shall apply:
a. Vertical Structure. The vertical structural elements of a building—comprising piers, columns, or portions of solid wall which flank each bay of the facade (see §8 2 A 2)—shall be configured so as to visually carry the apparent weight of upper floors down to the ground in a coherent manner (see precedents below) If any vertical structural element is expressed but does not extend to the ground, it shall be supported by structure beneath it, with a visual system of weight transference from the supported element to the ground
b. Horizontal Structure. Horizontal structural elements—such as beams and lintels—shall be sized to appropriately support the visual weight of the building mass and elements above them with respect to the distance they span
c. Structural Honesty. The visual system of bays and structure that is expressed on the facade shall be organized and configured to express or reinforce the actual building structure
==> picture [170 x 108] intentionally omitted <==
==> picture [246 x 232] intentionally omitted <==
Bays of windows framed by masonry building structure
==> picture [170 x 99] intentionally omitted <==
Storefront windows framed by structural elements
AVOID: Heavy upper floor building masses are not coherently supported. Vertical structure elements which frame upper floor bays randomly misalign with those in the building's base.
18 Attachment 1:131
Publication, Apr 2026
SANTA CLARA CODE
41 | Chapter 8: Facade Design
2. Architectural Elements. To ensure that architectural elements appear to be properly supported, the following standards shall apply:
a. Projections. Architectural Elements projecting from the building’s facade—i e balconies, bay windows, and deep roof eaves—shall be visually supported with brackets, corbels, cantilevered beams, or structure that transfers their weight to the structural vertical and horizontal elements of the facade as defined in 1a / 1b
3. Materials and Color. To ensure that materials and color reinforce the visual structural logic of a facade, the following standards shall apply:
- a. As stated in §8 2 E 4, materials heavier in apparent weight (i e brick) shall be used below materials that are lighter in apparent weight (i e wood siding)
b. Colors also suggest visual weight Colors should complement, and in no way undermine, the visual structural logic of a facade
b. Heavy Elements. Heavy elements—i e those made of masonry, projecting bays or rooms, etc —shall appear to be supported rather than floating or affixed onto a weaker-appearing material
c. Non-Supportive Elements. Elements which are intended to be accents to the facade—i e such as spandrel panels between windows—shall not project from the facade Rather, they shall be inset as architectural relief, with the facade material holding it in place visible around it There shall be no floating elements or details which appear artificially pasted on
==> picture [170 x 238] intentionally omitted <==
Traditional bay windows had wooden and masonry structural elements, creating a coherently-supported assembly
==> picture [170 x 239] intentionally omitted <==
This modern bay window has a metal structural frame supported by concrete cantilevers.
==> picture [170 x 105] intentionally omitted <==
Balcony supported by metal tension rods.
==> picture [171 x 133] intentionally omitted <==
Spandrel panels are recessed into the wall between vertical structural elements.
==> picture [170 x 259] intentionally omitted <==
Color reinforces the role of the panels as decorative rather than strong and loadbearing.
18 Attachment 1:132
Publication, Apr 2026
ZONING
42 | City of Santa Clara Downtown Form-Base Code
9 Private Frontages
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Santa Clara Zoning Code
- Article 1 — Enactment and Applicability
- Chapter 18.02 — Purpose and Applicability of Zoning Code
- Chapter 18.04 — Interpretation of the Zoning Code Provisions
- Chapter 18.06 — Zoning Map and Zones
- Chapter 18.10 — Residential Zones (R1, R2, R3, R4, R5, R6, UC,…
- Chapter 18.12 — Commercial Zones (C-C, C-N, C-R)
- Chapter 18.14 — Mixed Use Zones (MU-NC, MU-CC, MU-RC, MU-MD, M…
- Chapter 18.16 — Office and Industrial Zones (LO-RD, HO-RD, LI,…
- Chapter 18.18 — Special Purpose Zones (OS, PQP)
- Chapter 18.20 — Planned Development Zone (PD)
- Chapter 18.22 — Lawrence Station Area Plan Zoning District (LS…
- Chapter 18.24 — Two-Unit Dwelling Residential Development and …
-
▸ Chapter 18.26 — Downtown Form-Based Code
Overview- 1.1. Introduction
- 1.2. Applicability
- 1.3. Rules of Construction
- 1.4. Architectural Review
- 1.5. Public Notice
- 1.6. Director Interpretations
- 1.7. Deviation from Standards
- 2.1. A New Code for Downtown Santa Clara
- 3.1. Summary of Regulating Topics
- 4.1. The Downtown Zone
- 4.2. Character Overlays
- 5.2. Applicability
- 5.1. Intent
- 5.3. Standards
- 6.1. Intent
- 6.2. Applicability
- 6.3. Standards
- 6.3 Standards (continued)
- 6.3 Standards (continued)
- 7.1. Intent
- 7.2. Applicability
- 7.3. Standards
- 7.3 Standards (continued)
- 7.3 Standards (continued)
- 8.1. Intent and Applicability
- 8.2. Standards
- 8.2 Standards (continued)
- 8.2 Standards (continued)
- 9.1. Intent
- 9.3. General Standards
- 9.2. Applicability
- 9.4. Standards by Frontage Type
- 10.1. Intent
- 10.2. Applicability
- 10.3. General Standards
- 10.4. Standards & Guidelines by Type
- 11.1. Intent and Applicability
- 11.2. General Standards
- 11.3. Standards & Guidelines by Type
- 12.1. Building Use
- 12.2. Specified Use Definitions
- 12.3. CUP Conditions of Approval
- 12.4. Parking Requirements
- 12.5. Parking Design Standards
- 13.1. Introduction
- 13.2. Specific to Waste and Utility Placement
- 13.3. Specific to Site Walls
- 13.4. Specific to Lighting
- 13.5. On-Site Open Space
- 13.6. Elevating a Place with Art
- Article 3 — Site Planning and General Development Standards
- Chapter 18.30 — Site Planning and General Development Standards
- Chapter 18.32 — Residential Accessory Structures
- Chapter 18.34 — Fences, Walls, Hedges, and Screens
- Chapter 18.36 — Landscaping Standards
- Chapter 18.38 — Off-Street Parking Regulations and Design Stan…
- Chapter 18.40 — Performance Standards
- Chapter 18.42 — Sign Standards
- Chapter 18.60 — Standards for Specific Land Uses
- Chapter 18.62 — Adult Business Uses
- Chapter 18.64 — Density Bonus and Affordable Housing
- Chapter 18.66 — Wireless Telecommunications Facilities
- Chapter 18.90 — General Nonconforming Provisions
- Chapter 18.92 — Nonconforming Structures
- Chapter 18.94 — Nonconforming Uses
- Chapter 18.96 — Nonconforming Parcels
- Chapter 18.98 — Other Specific Nonconforming Provisions
- Chapter 18.110 — General Provisions
- Chapter 18.112 — Application Processing Procedures
- Chapter 18.114 — Conditional and Minor Use Permits
- Chapter 18.116 — Off-Site Parking Permits
- Chapter 18.118 — Reasonable Accommodation
- Chapter 18.120 — Architectural Review
- Chapter 18.122 — Temporary Use Permits
- Chapter 18.124 — Variances and Minor Modifications
- Chapter 18.126 — Zoning Clearances
- Chapter 18.128 — Permit Implementation, Time Limits, and Exten…
- Chapter 18.130 — Historic Preservation
- Title 18 — Zoning Code