Chapter 18.26 — Downtown Form-Based Code
13.2. Specific to Waste and Utility Placement
Santa Clara Zoning Code · 2026-06 edition · updated 2026-07-25 · Santa Clara
A. Utility Access and Equipment
1. Utility access and equipment such as back-flow preventers, transformer boxes, telecommunications pedestals, gas and electric meters, and other utilities shall be placed either: within or adjacent to alleys and be accessed from the alley; in underground vaults; or in utility rooms/closets within buildings—subject to the requirements and approval of the associated utility company If such locations are infeasible, these services shall be in inconspicuous locations along the sides or rears of project sites and shall be thoroughly screened from public view Such utility equipment shall not be located above grade in the street, sidewalk, sidewalk planters/planting strip, or within the front building setback area
B. Mechanical Access & Equipment
1. All mechanical and electrical equipment – including, but not limited to, airconditioning units, antennas, garage door motors – whether roof-mounted, ground-mounted or otherwise, shall be screened from public view or located so as not to be visible from streets or open spaces Such equipment and related screening should be designed with materials and colors that conform to and are an integral part of the design of the building
- b. Noise and odor-generating equipment and containers should be located in areas that will not create a nuisance to adjacent properties Such bins should be covered when possible Openings to a trash enclosure should be shielded from public rights of way
C. Telecommunication Devices
1. Telecommunication devices (such as satellite dishes or other equipment) should be screened from public view or located so as not to be visible from streets Applicants are encouraged to work with satellite providers to locate satellite dishes out of view on building roofs and/or on rear yard or side yard facing facades, especially along alleys, if adequate signal strength and quality can be achieved In multi-family and multi-tenant buildings, conduits should be provided from such a location to each unit or designed into the building structure
D. Wet Utilities
1. Wet utilities should typically be located in the street, but may be located in the alley to address topographical, efficiency or other engineering reasons If “wet” and “dry” utilities are co-located in the alley, proper trench separation and utility access must be ensured On lots with no alley, all “wet” utilities should be located in the street or public right-of-way Utility meters and entrances should also be provided below-grade in the street or sidewalk and should be flush with the surrounding grade
E. Service Entrances & Waste/Recycling Disposal Areas
1. Service entrances, waste/recycling disposal areas, and other similar service areas should be located adjacent to the alley and take their access from it On lots with no alley, these areas should be located as far away as possible from— and screened from views from—the public right of way
2. Waste/recycling disposal shall not be staged on the street Waste and recycling shall be retrieved via push/pull or interior to the building
- a. Mechanical equipment that generates noise, smoke or odors, shall not be located on or within 10 feet of a public right of way or any on-site common open spaces
18 Attachment 1:167
Publication, Apr 2026
SANTA CLARA CODE
77 | Chapter 13: Site Standards & Guidelines
FIGURE 13-1 | APPROPRIATE PLACEMENT
Example of an appropriately placed double standpipe connection in the base of a building at the sidewalk.
==> picture [190 x 121] intentionally omitted <==
Example of mechanical equipment wellscreened by an architectural element incorporated into the building's composition.
==> picture [190 x 121] intentionally omitted <==
Wherever possible, mechanical/utilities equipment should be placed in alleys. In this example, they are further shielded by architectural elements and a hedge.
==> picture [190 x 120] intentionally omitted <==
FIGURE 13-2 | INAPPROPRIATE PLACEMENT
Example of inappropriately placed ground-level utilities in a parkway. Example of inappropriately placed utility boxes in a parkway. Example of inappropriately placed check valves and other utility devices in the front yard of a commercial building.
18 Attachment 1:168
Publication, Apr 2026
ZONING
78 | City of Santa Clara Downtown Form-Base Code
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Santa Clara Zoning Code
- Article 1 — Enactment and Applicability
- Chapter 18.02 — Purpose and Applicability of Zoning Code
- Chapter 18.04 — Interpretation of the Zoning Code Provisions
- Chapter 18.06 — Zoning Map and Zones
- Chapter 18.10 — Residential Zones (R1, R2, R3, R4, R5, R6, UC,…
- Chapter 18.12 — Commercial Zones (C-C, C-N, C-R)
- Chapter 18.14 — Mixed Use Zones (MU-NC, MU-CC, MU-RC, MU-MD, M…
- Chapter 18.16 — Office and Industrial Zones (LO-RD, HO-RD, LI,…
- Chapter 18.18 — Special Purpose Zones (OS, PQP)
- Chapter 18.20 — Planned Development Zone (PD)
- Chapter 18.22 — Lawrence Station Area Plan Zoning District (LS…
- Chapter 18.24 — Two-Unit Dwelling Residential Development and …
-
▸ Chapter 18.26 — Downtown Form-Based Code
Overview- 1.1. Introduction
- 1.2. Applicability
- 1.3. Rules of Construction
- 1.4. Architectural Review
- 1.5. Public Notice
- 1.6. Director Interpretations
- 1.7. Deviation from Standards
- 2.1. A New Code for Downtown Santa Clara
- 3.1. Summary of Regulating Topics
- 4.1. The Downtown Zone
- 4.2. Character Overlays
- 5.2. Applicability
- 5.1. Intent
- 5.3. Standards
- 6.1. Intent
- 6.2. Applicability
- 6.3. Standards
- 6.3 Standards (continued)
- 6.3 Standards (continued)
- 7.1. Intent
- 7.2. Applicability
- 7.3. Standards
- 7.3 Standards (continued)
- 7.3 Standards (continued)
- 8.1. Intent and Applicability
- 8.2. Standards
- 8.2 Standards (continued)
- 8.2 Standards (continued)
- 9.1. Intent
- 9.3. General Standards
- 9.2. Applicability
- 9.4. Standards by Frontage Type
- 10.1. Intent
- 10.2. Applicability
- 10.3. General Standards
- 10.4. Standards & Guidelines by Type
- 11.1. Intent and Applicability
- 11.2. General Standards
- 11.3. Standards & Guidelines by Type
- 12.1. Building Use
- 12.2. Specified Use Definitions
- 12.3. CUP Conditions of Approval
- 12.4. Parking Requirements
- 12.5. Parking Design Standards
- 13.1. Introduction
- 13.2. Specific to Waste and Utility Placement
- 13.3. Specific to Site Walls
- 13.4. Specific to Lighting
- 13.5. On-Site Open Space
- 13.6. Elevating a Place with Art
- Article 3 — Site Planning and General Development Standards
- Chapter 18.30 — Site Planning and General Development Standards
- Chapter 18.32 — Residential Accessory Structures
- Chapter 18.34 — Fences, Walls, Hedges, and Screens
- Chapter 18.36 — Landscaping Standards
- Chapter 18.38 — Off-Street Parking Regulations and Design Stan…
- Chapter 18.40 — Performance Standards
- Chapter 18.42 — Sign Standards
- Chapter 18.60 — Standards for Specific Land Uses
- Chapter 18.62 — Adult Business Uses
- Chapter 18.64 — Density Bonus and Affordable Housing
- Chapter 18.66 — Wireless Telecommunications Facilities
- Chapter 18.90 — General Nonconforming Provisions
- Chapter 18.92 — Nonconforming Structures
- Chapter 18.94 — Nonconforming Uses
- Chapter 18.96 — Nonconforming Parcels
- Chapter 18.98 — Other Specific Nonconforming Provisions
- Chapter 18.110 — General Provisions
- Chapter 18.112 — Application Processing Procedures
- Chapter 18.114 — Conditional and Minor Use Permits
- Chapter 18.116 — Off-Site Parking Permits
- Chapter 18.118 — Reasonable Accommodation
- Chapter 18.120 — Architectural Review
- Chapter 18.122 — Temporary Use Permits
- Chapter 18.124 — Variances and Minor Modifications
- Chapter 18.126 — Zoning Clearances
- Chapter 18.128 — Permit Implementation, Time Limits, and Exten…
- Chapter 18.130 — Historic Preservation
- Title 18 — Zoning Code