701.2(2)(a) Revise this section as follows:
701.2(2)(a) [ ← ]
The arrow represents the location of language that has been deleted by San Francisco from the applicable California Code.
ABS and PVC installations are limited to not more than two stories of areas of commercial or private residential accommodations.
701.2(3) Revise this section as follows:
701.2(3) No vitrified clay pipe or fittings shall be used aboveground or where pressurized by a pump or ejector or underground within the foundation line of the building. They shall be kept not less than 12 inches (305 mm) belowground.
701.2(7) Add the following section:
701.2(7) Copper tubing shall not be used for urinal drainage or applications which are detrimental to the integrity of copper tubing.