Skip to content

Chapter 9A — FLOODPLAIN MANAGEMENT

Needles Municipal Code Art. 9A V Provisions For Flood Hazard Reduction

Needles Municipal Code · 2026-09 edition · updated 2026-10-04 · Needles

Cite as: Needles Municipal Code Article 9A · Text as of 2026-10-04

9A-17 Standards Of Construction 9A-18 Standards For Utilities 9A-19 Standards For Subdivisions 9A-20 Standards For Manufactured Homes 9A-21 Standards For Recreational Vehicles

9A-22 Floodways

9A-17 Standards Of Construction

In all areas of special flood hazards the following standards are required:

  1. Anchoring. 1. All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 2. All manufactured homes shall meet the anchoring standards of section 9A-20.

    1. Construction Materials and Methods. All new construction and substantial improvement shall be constructed: 1. With flood resistant materials as specified in FEMA Technical Bulletin TB 2-93, and utility equipment resistant to flood damage; 2. Using methods and practices that minimize flood damage; 3. With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and 4. If within Zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide floodwaters arounds and away from proposed structures.
    2. Elevation and Floodproofing. (See article II, Definitions for “basement”, “lowest floor”, “New construction,” “Substantial damage” and “Substantial improvement.”) 1. Residential construction, new or substantial improvement, shall have the lowest floor, including basement: 1. In an AO zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in fee on the FIRM, or elevated at least two feet above the highest adjacent grade if not depth number is specified. 2. In an A zone, elevated to or above the base flood elevation; said base flood elevation shall be determined by one of the methods in Section 9A-15(b) of this ordinance. (The State of California recommends the lowest floor be elevated at least two feet above the base flood elevation, as determined by the community.) 3. In all other zones, the lowest floor shall be elevated to at least one foot above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator. 2. Nonresidential construction, new or substantial improvement, shall either be elevated to conform with subsection (C)(1) of this section or together with attendant utility and sanitary facilities. 1. Be floodproofed to one foot above the elevation recommended under subsection (C)(1) of this section so that the structure is watertight with walls substantially impermeable to the passage of water; 2. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and
  2. Be certified by a registered Professional Engineer or Architect that the standards of Sections (C)(2))A)&(B) are satisfied. Such certification shall be provided to the floodplain administrator. 3. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement shall follow the guidelines in FEMA Technical Bulletins TB 1-93 and TB 7-93, and must exceed the following minimum criteria: 1. Have a minimum of two openings having a total net area of not less than on square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater; or 2. Be certified by a registered professional engineer or architect. 4. Manufactured homes shall also meet the standards in section 9A-20. (Ord. No. 431-AC, § 5.1; Ord. No. 457-AC, § 2 (part).)

9A-18 Standards For Utilities

  1. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate: 1. Infiltration of floodwaters into the systems; and
    1. Discharge from the systems into floodwaters.
  2. On-site waste disposal systems shall be located to avoid impairment to them, or contamination from them, during flooding. (Ord. No. 431-AC, § 5.2; Ord. No. 457-AC, § 2 (part).)

9A-19 Standards For Subdivisions

  1. All preliminary subdivision proposals shall identify the special flood hazard area and the elevation of the base flood.
    1. All subdivision plans will provide the elevation of proposed structure(s) and pad(s). If the site is filled above the base flood elevation, the lowest floor and pad elevations shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator.
    2. All subdivision proposals shall be consistent with the need to minimize flood damage.
    3. All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage.
    4. All subdivisions shall provide adequate drainage to reduce exposure to flood hazards. (Ord. No. 431-AC, § 5.3; Ord. No. 457-AC, § 2 (part).)

9A-20 Standards For Manufactured Homes

  1. All manufactured homes that are placed or substantially improved within Zones A, A1--30, Ah, and AE on the community’s Flood Insurance Rate Map, on sites located: 1. Outside of a manufactured home park or subdivision;
    1. In a new manufactured home park or subdivision;
    2. In an expansion to an existing manufactured home park or subdivision; or
  1. In an existing manufactured home park or subdivision on a site upon which a manufactured home has incurred “substantial damage” as the result of a flood; shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated at least two feet above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.
    1. All manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within Zones A, A1--30, AH, and AE, on the community’s Flood Insurance Rate Map that are not subject to the provisions of subsection (a) of this section will be securely fastened to an adequately anchored foundation system to resist flotation, collapse and lateral movement, and be elevated so that either the: 1. Lowest floor of the manufactured home is at least two feet above the base flood elevation; of 2. Manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six inches in height above grade. Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator.

9A-21 Standards For Recreational Vehicles

  1. All recreational vehicles placed on sites within Zones A1--30, AH, and AE on the community’s Flood Insurance Rate Map will either: 1. Be on the site for fewer than one hundred eighty consecutive days, and be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or 2. Meet the permit requirements of article IV of this chapter and the elevation and anchoring requirements for manufactured homes in section 9A-20(a). (Ord. No. 431-AC, § 5.5; Ord. No. 457-AC, § 2 (part).)

9A-22 Floodways

Located within areas of special flood hazard established in section 9A-7 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following provisions apply:

  1. Prohibit encroachments, including fill, new construction, substantial improvement, and other new development unless certification by a registered professional engineer or architect is provided demonstrating that encroachments shall not result in any increase in (the base) flood elevation during the occurrence of the base flood discharge.
  2. If subsection (a) of this section is satisfied, all new construction, substantial improvement, and other proposed new development shall comply with all other applicable flood hazard reduction provisions of article V. (Ord. No. 431-AC, § 5.6; Ord. No. 457-AC, § 2 (part).)

Get a plain-English answer with a citation back to this text.