Division 11 — APPENDIX A4 RESIDENTIAL VOLUNTARY MEASURES
Los Angeles Municipal Code § 99.11 Appendix A4 Residential Voluntary Measures
Los Angeles Municipal Code · 2026-09 edition · updated 2026-10-04 · Los Angeles
Cite as: Los Angeles Municipal Code § 99.11 · Text as of 2026-10-04
99.11.101 Scope.¶
99.11.102 General. 99.11.602
SEC. 99.11.101. SCOPE.¶
(Amended by Ord. No. 187,719, Eff. 1/23/23.)
Appendix A4 of the California Green Building Standards Code (CALGreen) is adopted by reference with the following exceptions: CALGreen Section A4.105.2, A4.106.7, Table A4.106.8.3.1, Table A4.106.8.3.2, A4.305.2, A4.403.1, A4.404.1, A4.405.2, A4.405.4, A4.407.1, A4.407.3, A4.407.4, A4.407.5, A4.407.7, A4.602, and Table A4.106.5.1(1) are not adopted; and in lieu, LAMC Sections 99.11.102 and 99.11.602, and Subsections A4.105.2, A4.106.7, A4.405.2, A4.405.4, A4.407.1, A4.407.7, A4.602, and Tables A4.106.5.1(1), A4.106.5.1(2), A4.106.5.1(3), and A4.106.5.1(4) are added or amended as provided in this article.
SEC. 99.11.102. GENERAL.¶
(Amended by Ord. No. 187,719, Eff. 1/23/23.)
This section shall set forth the Residential Voluntary Measures.
A4.105.2. Reuse of Materials. Use salvaged, refurbished or reused materials for a minimum of 2.5% of the total value, based on estimated cost of materials on the project. Materials which can be easily reused include but are not limited to the following:
Light fixtures;
Plumbing fixtures;
Doors and trim;
Masonry (reused masonry may only be used for flatwork);
Electrical devices;
Appliances;
Foundations or portions of foundations.
Note: Reused material must be in compliance with the appropriate California Code of Regulations Title 24 requirements. (Amended by Ord. No. 185,587, Eff. 7/16/18.)
TABLE A4.106.5.1(1)
TIER 1 – LOW RISE RESIDENTIAL
MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED
ROOF SLOPE REFLECTANCE EMITTANCE SRI ≤ 2 : 12 0.68 0.85 82 > 2 : 12 0.28 0.85 27
TABLE A4.106.5.1(2)
TIER 2 – LOW-RISE RESIDENTIAL
MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED
ROOF SLOPE REFLECTANCE EMITTANCE SRI ≤ 2 : 12 0.70 0.85 85 > 2 : 12 0.34 0.85 35
TABLE A4.106.5.1(3)
TIER 1 – HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS
MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED
ROOF SLOPE REFLECTANCE EMITTANCE SRI ≤ 2 : 12 0.68 0.85 82 > 2 : 12 0.28 0.85 27
TABLE A4.106.5.1(4)
TIER 2 – HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS
MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED ROOF SLOPE REFLECTANCE EMITTANCE SRI ≤ 2 : 12 0.70 0.85 85 > 2 : 12 0.34 0.85 35
A4.106.7. Reduction of Heat Island Effect for Nonroof Areas [N]. (Added by Ord. No. 187,208, Eff. 11/5/21.) Reduce nonroof heat islands for 75% of pathways, patios, driveways, or other paved areas by using one or more of the methods listed.
- Use trees or other plantings to provide shade and that mature within 15 years of planting. Trees shall be suitable in mature size and environmental requirements for the site. Tree selection and placement shall consider location and size of areas to be shaded, location of utilities, views from the structure, distance to sidewalks and foundations, overhangs onto adjacent properties and streets, and other infrastructure adjacent to landscaping. In addition, shading shall not cast a shadow, as specified, on any neighboring solar collectors pursuant to Public Resources Code Section 25981, et seq. (Solar Shade Control Act); 2. Use high albedo materials with an initial solar reflectance value of at least .30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E1918 or C1549; 3. Use open grid pavement system or pervious or permeable pavement system; 4. Use solar panel arrays to create a canopy shade system; or 5. Other methods of reducing heat island effects acceptable to the Department.
A4.405.2. Concrete Floors. 75% of all slab-on-grade and structural concrete slab floors that do not require additional coverings are used including but not limited to stained, natural or stamped concrete floors.
Note: Uncovered floors must still remain durable and maintain any acoustical insulation required elsewhere by the Los Angeles Municipal Code.
A4.405.4. Use of Building Materials from Rapidly Renewable Sources. One or more of the following materials manufactured from rapidly renewable sources or agricultural by-products is used for a minimum of 2.5% of the total value, based on estimated cost of materials on the project:
1. Insulation;
2. Bamboo or cork;
3. Engineered products;
4. Agricultural based products;
5. Other products acceptable to the enforcing Department.
Note: The intent of this section is to utilize building materials and products which are typically harvested within a 10-year or shorter cycle.
A4.407.1. Drainage Around Foundations. Where not required by code or ordinance, install foundation and landscape drains which discharge to a dry well, sump, bioswale or other approved on-site location.
A4.407.7. Roof Overhangs. When permitted by the Los Angeles Municipal Code, a permanent overhang or non-retractable awning at least 2 feet in depth is provided at all exterior walls.
SEC. 99.11.602. (Amended by Ord. No. 187,719, Eff. 1/23/23.)¶
Section A4.602 of the CALGreen Code is adopted with amendments to read as follows:
TABLE A4.602
RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST {'{'}Click here for a printable PDF version of this table{'}'}
LEVELS VERIFICATIONS
APPLICANT TO SELECT ELECTIVE ENFORCING AGENCY TO SPECIFY
MEASURES VERIFICATION METHOD
FEATURE OR MEASURE Prerequisites and Enforcing Installer or Third
electives 1 Agency Designer Party
Mandatory ____ ____ ____
Tier 1 Tier 2 All All All
LEVELS VERIFICATIONS
APPLICANT TO SELECT ELECTIVE ENFORCING AGENCY TO SPECIFY
MEASURES VERIFICATION METHOD
Prerequisites and Enforcing Installer or Third FEATURE OR MEASURE
electives 1 Agency Designer Party
Mandatory ____ ____ ____
Tier 1 Tier 2 All All All
PLANNING AND DESIGN
Site Selection A4.103.1 A site which complies with at least one of the following characteristics is selected: 1. An infill site is selected.
A greyfield site is selected.
An EPA-recognized Brownfield site is selected.
A4.103.2 Facilitate community connectivity by one of the following methods: 1. Locate project within a 1/4-mile true walking distance of at least 4 basic services; 2. Locate project within 1/2-mile true walking distance of at least 7 basic services; 3. Other methods increasing access to additional resources. Site Preservation
A4.104.1 An individual with oversight responsibility for the project has participated in an educational program promoting environmentally friendly design or development and has provided training or instruction to appropriate entities.
Deconstruction and Reuse of Existing Materials
A4.105.2 Existing buildings are disassembled for reuse or recycling of building materials. The proposed structure utilizes at least one of the following materials which can be easily reused: 1. Light fixtures
Plumbing fixtures
Doors and trim
Masonry (reused for flatwork)
Electrical devices
Appliances
Foundations or portions of foundations
Site Development