94.412.1.¶
Application. Urinals shall comply with ASME A112.19.2/CSA B45.1, ASME A112.19.19, or CSA B45/IAPMO Z124. Wall-mounted urinals shall have an average water consumption not to exceed 0.125
gallons (0.47 L) per flush. Other urinals shall have an average water consumption not to exceed 0.125 gallons (0.47 L) per flush.
94.412.1.2.¶
Floor-Mounted Urinals. [BSC-CG, DSA-SS, DSA-SS/CC]. The effective flush volume of floor-mounted or other urinals shall not exceed 0.125 gallons (0.47 L) per flush in compliance with Chapter 5,
Division 5.3, of the California Green Buildings Standards Code (CAL Green).