Los Angeles Municipal Code § 18.7 Concrete
Los Angeles Municipal Code · 2026-09 edition · updated 2026-10-04 · Los Angeles
Cite as: Los Angeles Municipal Code § 18.7 · Text as of 2026-10-04
18.7.5.8 - Where the calculated point of contraflexure is not within the middle half of…¶
over the full height of the member.
91.1905.1.10. ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.9 to read as follows: (Amended by Ord. No. 188,739, Eff. 9/23/25
18.7.5.9 - At any section where the design strength, φP n , of the column is less than…¶
into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components may be assumed to be of opposite sign. For determination of the design strength, φP n , of the column, these moments may be assumed to result from the deformation of the frame in any one principal axis.
91.1905.1.11. ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding Section 18.10.4.6 to read as follows:
Get a plain-English answer with a citation back to this text.
Ask AI about this code